Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.7 CrAccepted-AOC FLAT NO 2450 KRISHNA COLONY JIND 126102 | JIND | HARYANA | 126102 | ₹4.7 Cr | L-1 | Accepted-AOC AOC |
| 2 | L-2₹4.8 Cr+₹2.6 L (0.55%)Rejected-Finance VPO BERLA TEHSIL AND DISTT CHARKHI DADRI HARYANA | CHARKI DADRI | HARYANA | 127022 | ₹4.8 Cr+₹2.6 L (0.55%) | L-2 | Rejected-Finance You are L-2 |
| 3 | L-3₹4.9 Cr+₹12.0 L (2.52%)Rejected-Finance 52 SHANTI NAGAR MODEL TOWN PANIPAT OPPOSITE AMAR STEEL SHUTTERING WORKS 132103 | PANIPAT | PANIPAT | HARYANA | 132103 | ₹4.9 Cr+₹12.0 L (2.52%) | L-3 | Rejected-Finance You are L-3 |
| 4 | L-4₹4.9 Cr+₹14.3 L (3.02%)Rejected-Finance RGTPP KHEDAR HISAR HARYANA | HISAR | HARYANA | 125001 | ₹4.9 Cr+₹14.3 L (3.02%) | L-4 | Rejected-Finance You are L-4 |
| 5 | L-5₹5.3 Cr+₹55.0 L (11.6%)Rejected-Finance 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹5.3 Cr+₹55.0 L (11.6%) | L-5 | Rejected-Finance You are L-5 |
Tender Value
₹4.9 Cr
EMD Value
₹9.8 L
Closing Date
1 Mar 2025, 5:00 pmClosed
KARAN BEHAL
Panipat PHED No. 1
SUTANA - ROUGH COST ESTIMATE FRAMED BY EXECUTIVE ENGINEER, PUBLIC HEALTH ENGINEERING DIVISION NO. 1 PANIPAT FOR RENOVATION AND UP-GRADATION OF WATER SUPPLY SCHEME, LAYING OF DI LINE IN PARALLEL OF OLD PVC/ AC LINE, RAW WATER PUMPING STATION
2025_HRY_429327_1
2025FBDE4CF1 1038 4869 8B86 C0A55EBD2FED573PUH
Open Tender
Civil Works
Works
150 days
SUTANA
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹9.8 L
Yes
14 May 2025
18 Feb 2025
1 Mar 2025
18 Feb 2025
1 Mar 2025
18 Feb 2025
Amount
Supply, erection, testing of reputed make LED light 100 watts with fitting, wiring and accessories complete in respects.
Supplying, erection, testing and commissioning or Horizontal motor pumping set of Raw water having head 12.00 m as requirements of discharge 1000 LPM and power capacity 5.00 BHP as ISI Marked
Design construction, testing and commissioning of 1.50 MLD capacity Water Treatment Plant including inlet channel, Alum dozing Flash mixing, Clarifloculator, filter box, over head Reservoir for back wash, waste water tank including all civil work, Pumping machineries and electric cabling. Control panels entire piping network of suitable size, laying the DI pipe from raw water pump to inlet box of WTP, WTP to CWT. and Suction Well for CW including DI specials, suitable size Sluice valves, Hodies, manhole covers, air scour equipment, chemical house include chlorination equipment and arrangement of flow measurement and sand bed complete in all respects as per NIT (BASED ON SCADA SYSTEM- 1.50 MLD)..
Supply, erection testing and commissioning of raw water horizontal split casing Pump Set with 3800 LPM 20.00 Mtr. Head and 30.00 BHP induction Motor with base plate and coupling complete in all respect.
Operation and maintenance for complete scope of work mentioned in DNIT. 1. Operation and maintenance for 12 months during defect liability period after trial run of 3 months.
Operation and maintenance during 1st year defect liability period after trial run of 3 months.
Operation and maintenance during 2nd year defect liability period after trial run of 3 months.
Operation and maintenance during 3rd year defect liability period after trial run of 3 months.
Operation and maintenance during 4th year defect liability period after trial run of 3 months.
Operation and maintenance during 5th year defect liability period after trial run of 3 months.
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 1 no. 30.00 BHP Raw water induction Motor ) a) Main switch 200 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 200/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 200 Amp. = 1 No. each
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 1 no. 5.00 BHP Raw water induction Motor ) a) Main switch 63 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 200/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 200 Amp. = 1 No. each for 2 pump sets.
Bidder Name
Amount
Jai Shree Balaji Constn Co. (GSTN-06AKLPK7500N1ZV) BID ID -1221543
OM PARKASH CONT (GSTN-NA) BID ID -1221561
NAFE SINGH CONTRACTOR (GSTN-NA) BID ID -1221378
M/S AAR PEE CONSTRUCTION COMPANY JIND (GSTN-06ACEFA1525A1Z8) BID ID -1221489
JASVEER SINGH CONTRACTOR (GSTN-NA) BID ID -1221497
OM PARKASH CONT (BID ID -1221561)
JASVEER SINGH CONTRACTOR (BID ID -1221497)
NAFE SINGH CONTRACTOR (BID ID -1221378)
Jai Shree Balaji Constn Co. (BID ID -1221543)
NAFE SINGH CONTRACTOR (BID ID -1221378)
OM PARKASH CONT (BID ID -1221561)
M/S AAR PEE CONSTRUCTION COMPANY JIND (BID ID -1221489)
JASVEER SINGH CONTRACTOR (BID ID -1221497)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .