Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹47.6 L+₹2.8 L (6.15%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹59.4 L+₹14.6 L (32.5%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹68.4 L+₹23.6 L (52.7%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹53 L
EMD Value
₹1.0 L
Closing Date
27 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
PROVISION OF 600 KVA POWER SUPPLY AND EXTERNAL SERVICES FOR CERTAIN CENTRE UNDER GE (SOUTH) BANGALORE
2020_MES_352412_1
85997 /E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Bangalore
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE South Bangalore
₹1.0 L
Yes
HQ CWE ARMY BANGALORE
14 Aug 2020
26 Jun 2020
29 Jul 2020
26 Jun 2020
27 Jul 2020
12 Jul 2020
26 Jun 2020 - 4 Jul 2020
4 Jul 2020
60 days
Amount
Excavation in trenches not exe. 1.5 M deep and not exec 1.5 M wide and getting out in hard / dense soil complete all as directed.
Returning, filling in including spreading, levelling, watering, ramming, consolidating etc. of each layer N exc 250 mm thick complete all as directed.
Removing excavated meterial to a distance N exceeding 50 M and depositing where directed at a level N exceeding 1.5 M above the starting point complete all as directed.
Reinforced precast concrete cable cover, class HV, type-I, flat, size 300 x 180 x 40 mm complete all as directed.
River sand including cleaning, spreading, levelling, punning for laying as in cussioning of cables complete all as directed. Note:- For purpose of payment punned thickness only will be measured.
PCC (1:3:6) type C1 by using 20 mm graded stone aggregate as in mass concrete for sub base of poles / panels, repair to road surface etc. complete all as directed.
Supply, Laying, connecting, testing and commissioning XLPE insulated, earthed, screened, PVC bedded, galvanised steel strip or wire armoured electrical power cable (heavy duty) with stranded aluminium conductor 11000 Volts grade of size 3 core 400 Sqmm, ISI marked, conforming to IS 7098 Part-II complete all as directed. Note:- (a) Excavation, earthwork and cable protection measured separately. (b) High voltage test shall be conducted at site with suitable voltage after laying of HT cables in presence of Engineer-in-Charge, JE & reading shall be recorded jointly and test report to be submitted in triplicate. The cost of the same deemed to be included in the unit rate.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as directed.
Supply only Chain link MS galvanisd fencing, 4 mm dia and 50 x 50 mm size complete all as directed.
Excavating in post holes (or similar holes) each N exc 0.5 Cum, in hard / dence soil getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 Cm, complete all as diretced.
PCC 1:3:6 Type C2 by using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as directed.
Mild steel frame work conforming to Fe-410-0 or Fe 310-0 such as doors or gates of angle iron or other section including braces rails etc. complete drilled for fixing of steel sheeting or other covering doors etc. prepared for hanging or sliding with including either hooks and hinges or steel hanging door devices complete all as specified and as directed including painting with two coat of synthetic enameled paint over a coat of red oxide primer complete all as directed.
Two coats of synthetic enamel paint over a coat of red oxide primer including preperation of surface complete all as directed.
Surface excavation in hard / dence soil N. exc 300 mm deep (averaging 150 mm) and getting out complete all as directed.
Removing excavated material in soil N exc. 50 M and depositing where directed at a level N exc. 1.5 M above the starting point complete all as diercted.
Sand filling under floors or in foundations including watering and consolidation complete all as directed.
Hardcore of gauge N exc. 63 mm, deposited, spread and levelled in layers n exc. 150 mm thick, watered and rammed to a true surface complete all as directed.
Boring holes under road pavement hard standing by trenchless technology using ultra sound technology with necessary machine suitable for passing / laying two runs (in parallel) of 3 core, 400 Sqmm cable complete all as specified and as directed Note:- Quoted rates deems to be inclusive of transportation charges of drilling machine, connected accessories, Statutory charges for road cutting (getting necessary road cutting permission form BBMP / BESCOM / Traffic police authorities)
HDPE pipe of 160 mm outer dia, PN6 for cable protection complete all as directed
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 400 Sq mm complete all as directed.
Cable jointing kit for 11 KV grade for indoor termination (earthed system), heat shrinkable type complete with all necessary jointing material and accessories suitable for 3 core XLPE armoured aluminimum conductor cable of size 400 sqmm complete all as directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connecting with steel GI strip 32 x 6 mm as earthing lead by means of bolt nut check nuts and washers including PCC pit with 1:2:4 type B-1 using 20 mm graded stone aggregate and frame cover of angle iron 25 x 25 x 6 mm, MS sheet 3 mm thick and handle of 6 mm dia MS bar made to shape, GI medium grade 40 mm bore pipe for watering common salt chorcoal funnel wiremesh earth work in any type of soil returning filling in and removal of soil to a distance n.exc 50 mtr including earth test point and making connections testing on completion all as per electric plate No 3 of SSR Part-I, complete all as directed.
GI strip 32 x 6 mm for earth lead connection fixed on wall / pole with suitable clamps, screws etc., complete all as directed.
Supply, fixing, commissioning and testing 11 KV, Air Insulated HT Metering cubicle of different CT ratio, both side cable entry type without load break switch (LBS), DLMS features with resin cast 11 KV CT ratio / 1A, 2.5 VA, class 0.2, STC 20 KA / 1sec, ILV : 12/28/75 KVP and PT or ration 11 KV / Root 3 and 110 / Root 3 Burden 25 VA complete with transperent cover TTB, 30 x 8 mm copper busbars and two Nos of meters for 3 phase 4 wire metering, panel fabricated out of 3 mm MS sheet duly epoxy powder coated including PCC foundation for mounting the metering cubicle all as per latest BESCOM specifications including GSM Modem Model No. ARG 45 of AMI Tech (India) Pvt. Ltd. / BESCOM Approved and as directed. Make of CT/ PT : Schnieder / ABB / Siemens / BESCOM Approved Make of Meter : C&S / Secure / L&T / BESCOM Approved
Supplying, fixing, commissioning and testing of 11 KV, 350 MVA, 630 Amp, 5 way out door type RMU (Ring Main Unit) of 2 OD + 3 VL Right side extensible (compatible to BESCOM configuration including DAS) consisting of 2 Nos load break switch of 630 Amps and 03 Nos of 630 Amps, VCB and metering panel with protection and metering CTs, complete with PCC foundation for mounting including lettering the breaker with enamel paint and writing single line daigram for each panel as per followings specifications complete all as directed.
(i) Type - Out door type RMU (ii) Operating Voltage - 11 KV (iii) Rated Frequency - 50 HZ (iv) Rated start time current - 20 KA (v) Operation - Motorized (vi) VCB - 630 Amp (Fixed type) (vii) Load break system - 630 A (Fixed type) (viii) Protection - Self powered O/C and E/F Relay protection with suitable protector CTs for distribution transformer. (ix) Bus Bar - 630 Amps (x) Class of protection - (a) IP 67 for SF6 Gas Tank (SS) (b) IP 2X for front cover (c) IP 54 for outdoor enclosure Make:- Schneider / ABB / Siemens / BESCOM Approved
GI tube "light grade" 80 mm dia for cable protection in trenches / walls, ceiling, floors etc. complete all as directed.
Cable route indicator made out of round CI disc embosed HT cable, of size 160 mm dia, 6 mm thick duly revited with angle of size 50 x 50 x 4 mm and 600 mm long incuding PCC 1:2:4 type B2 using 20 mm graded stone aggreate, 150 x 150 x 150 mm for grouting the same all as directed.
Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters figures and convensional skull and bone in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 250 x 200 mm size complete all as directed.
LITE SYSTEMS INDUS
Shiva Shakthi Electrical Enterprises
K KUMAR RAJA PROJECTS P LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .