Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹11,500
Closing Date
30 Sept 2023, 11:00 amClosed
Superintending Engineer
S.E EUDC Office sec-18 Noida
Electrical Work Replacement of damaged Pole, Damage wire etc.
2023_PVVNL_839441_1
E-Tender No. 51/2023-24, EUDC-II, Noida.
Open Tender
Electrical Works
Item Rate
90 days
S.E EUDC Office sec-18 Noida
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E., EUDC-II Noida
₹11,500
4 Oct 2023
18 Sept 2023
30 Sept 2023
18 Sept 2023
30 Sept 2023
18 Sept 2023
Amount
fo|qr forj.k [k.M & prqFkZ] nknjh ds vUrxZr iz.kkyh lqn`<hdj.k tSls ttZj rkj] th0vkbZ0 ok;j o iksy cnyuk] xkfMZax bR;kfn lEcfU/kr dk;ZA (DETAIL OF WORK MENTIONED IN TENDER FORM)
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 3 to 8
11mtr ST Pole
ACSR Dog Conductor
PCC Pole 8.5 Mtr. Long
11 KV Disc Insulator with fitting
11 KV Pin Insulator with pin
11 KV XLPE Cable 3X185 Sqmm
SUPPLY OF FOLLOWING MATERIAL BY THE CONTRACTOR FROM THE PVVNL APPROVED VENDORS AS PER GTP APPROVED.
33KV Bus Isolator 800 Amp. for 33/11KV Substation Chithera, Dadri.
33KV Line Isolator 800 Amp. for at 33/11KV Substation NTPC Road, Dadri.
Cross Arm 100x50x6 mm G.I channel for 11KV line.
G.I.T- Channel 100x50x6x2240 mm long (9.56kg/mt) with 2 Nos. G.I.Clamp of 65x8mm
Heat Shrinkable outdoor type end termination cable jointing kit suitable for 11KV XLPE 3x185 Sq.mm. cable (Make - Raychem/3M/Denson)
Stay set complete (G.I.Stay rod 16x1800mm, Stay wire 5Kg, Guy insulator, G.I.Stay clamp, bolt, nut & wasther with concrete grouting) for 11KV line as per specification
Supply and Errection of the Following material for completing the work as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) ST Pole 11 MtR Long and 8.5MTR. PCC POLE
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) ST Pole 11 MtR Long and 8.5MTR. PCC POLE
FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT.
FIXING OF DISC INSULATOR WITH FITTING, COMPLETE WORK IN ALL RESPECT.
Laying, spreading, lifting and final sagging of 3 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel as per site requirement. (135Mtr. 33/11KV S/S NTPC Road, 12978 Mtr. 11KV Indus Feeder, 3120Mtr. 11 KV Mihir Bhoj Feeder and 5300Mtr. at 11KV Feeder of Dhoom Manikpur S/s)
Isolator Structure Erection of Isolator structure (Line and Bus) 05 Nos. size of plinth (0.9x0.30x1.0) m as per drawing No. RES-39 Excavation of earth for making 05 Nos. pits of size (0.9x0.30x1.0)m.
Fabrication of Isolator structure (Bus & Line) by using 4.0 m long 04 Nos. of G.I. channel of size (125x65x6)mm with bracing by G.I. Angle (40x40x5)mm/ (50x50x6)mm size and providing 02 Nos. top channel of G.I. Angle (75x75x6)mm and 2.6m long on both side of Isolator. The work also includes cutting, drilling, welding and proper alignment of the same for completion of work.
C.C. work in ratio of 1:4:8 (cement, fine sand and brick ballast) of size (0.90x0.30x0.15)m for 5 Nos. pits for making bed. Work includes proper ramming etc.
C.C. work of ratio 1:3:6 (cement, coarse sand and 25 mm stone grit) for pre-fabricated structure of Line and Bus isolator size of plinth (0.90x0.3x1.5)m for 5 Nos.
12mm thick plaster with cement mortar ratio 1:4 (cement & fine sand) of plinth of 0.4m upper side.
Laying and commissiong of overhead 11KV 3x185sqmm XLPE Cable at 11KV Indus Feeder and 11KV Feeder of Dhoom manikpur S/s.
Preparation of 11 KV Power Cable ends: Making of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
Fixing of 11 KV Top Channel as per site requirement.
Fixing of 11KV Cross Arm as per site requirement.
Fixing of 11KV Toff Channel as per site requirement.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps.
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Fixing of T/F base Angle as per site requirement.
FIXING OF PVC CABLE 1X400SQMM at different sites of T/F AS PER SITE REQUIREMENT.
FIXING OF PVC CABLE 1X240SQMM at different sites of T/F AS PER SITE REQUIREMENT.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps.
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Providing and Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Providing and Fixing of Best Quality MS Holding Clamp as per site requirement.
Providing and Fixing of Best Quality MS Nut Bolts and washers as per site requirement.
Providing and Fixing of Best Quality Stone Pad with grouting as per site requirement.
Providing and Fixing of Best Quality F Brackets as per site requirement.
Dismentaling of old & Damaged 02 Nos. 33KV Bus Isoloator at 33/11KV Substation Chithera and safe carriage of its from Site to any Store/Workshop of PVVNL including loading and unloading both ends.
Dismentaling of old & Damaged 03 Nos. 33KV Line Isoloator at 33/11KV SubstationNTPC Road and safe carriage of its from Site to any Store/Workshop of PVVNL including loading and unloading both ends.
Replacement of Tilt Pole of 11KV Indus Feeder.
Replacement of Damaged D/p of 11KV Indus Feeder and safe carriage of its from Site to any Store/Workshop of PVVNL including loading and unloading both ends.
Dismentaling of old and damaged ACSR Weasel Conductor of 11 KV Indus Feeder and safe carriage of its from Site to any Store/Workshop of PVVNL including loading and unloading both ends.
Dismentaling of old and damaged ACSR Rabbit Conductor of 11 KV Indus Feeder and safe carriage of its from Site to any Store/Workshop of PVVNL including loading and unloading both ends.
Trimming of Tree Branches lying of HT/LT line of 11KV Indus Feeder
Dismentaling of old and damaged PCC Poles of 11 KV Indus Feeder and safe carriage of its from Site to any Store/Workshop of PVVNL including loading and unloading both ends.
Dismentaling of old and damaged ACSR Conductor and safe carriage of its from Site to any Store/Workshop of PVVNL including loading and unloading both ends.
Dismentaling of old and damaged AB Cable and safe carriage of its from Site to any Store/Workshop of PVVNL including loading and unloading both ends.
Kunal Electricals
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .