| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | ₹1.2 Cr | 1 | Accepted-AOC Being lowest tender |
| 2 | 2₹1.4 Cr+₹18.5 L (15.7%)Rejected-Finance | ₹1.4 Cr+₹18.5 L (15.7%) | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹1.7 Cr+₹55.4 L (47.2%)Rejected-Finance | ₹1.7 Cr+₹55.4 L (47.2%) | 3 | Rejected-Finance Not being lowest |
| 4 | 4₹1.7 Cr+₹56.4 L (48.1%)Rejected-Finance | ₹1.7 Cr+₹56.4 L (48.1%) | 4 | Rejected-Finance Not being lowest |
| 5 | Rejected-Technical 205 2ND FLOOR VARDHMAN CHAMBER LL 0 VIKASPURI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | - | - | Rejected-Technical Not fulfills with criteria |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
18 Nov 2020, 6:00 pmClosed
CHIEF ENGINEER DELHI ZONE
HQ CE DELHI ZONE DELHI CANTT-10
ADDN/ALTN TO LIFTS AT ARMY HOSPITAL R AND R DELHI CANTT-10
2020_MES_362591_1
CEDZ-12 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
MES contractor enlisted in MES under class B cat c ii having deposited Standing Security of Rs 4.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹1,000
GE E/M RR HOSPITAL DELHI CANTT
₹2.6 L
Yes
6 Jan 2021
21 Jul 2020
20 Nov 2020
21 Jul 2020
18 Nov 2020
2 Nov 2020
Amount
(a) LED Light Ultra slim decorative aluminium casted, recess mounted square fixture in white with opal diffuser and separate electronic driver, suitable for low depth ceiling -12W BLAZE SQUARE with complete accessories including necessary wiring - 04 Nos
(b) Single phase centrifugal type cross flow blower 270 cu meter/hour-02 Nos.
(c) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per IS (minimum efficiency class equivalent to IE 2) and operating gearless box with independent main sheave rim.
(d) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(e) Micro processor based VVVF type main controller with closed loop system.
(f) Type of signal system FIGS fixtures with dot matrix display (Touch Panel) and car position indicator in car all fixture in SS face plate (both insided/out-side). All buttons should be with brail marking and luminous.
(g) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking, connect to complete cell and provn of through & other accessories.
(h) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside car to alert the persons trapped inside that they are being recued.
(j) Provision of governor and governor rope of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. Grooved Belt and alongwith belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator nearest landing.
(k) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(l) Door sensor not less than 74 beam, 2D infra red full length
(m) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(n) Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown
(o) Do's & Don’ts chart on stainless steel to be installed inside the car cabin.
(p) A three Pin plug socket with switch for hand lamp shall be fitted on top of the lift car for use by person working there on.
(a) LED Light Ultra slim decorative aluminium casted, recess mounted square fixture in white with opal diffuser and separate electronic driver, suitable for low depth ceiling -12W BLAZE SQUARE with complete accessories including necessary wiring - 04 Nos
(b) Single phase centrifugal type cross flow blower 270 cu meter/hour-02 Nos.
(c) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per IS (minimum efficiency class equivalent to IE 2) and operating gearless box with independent main sheave rim.
(d) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(e) Micro processor based VVVF type main controller with closed loop system.
(f) Type of signal system FIGS fixtures with dot matrix display (Touch Panel) and car position indicator in car all fixture in SS face plate (both insided/out-side). All buttons should be with brail marking and luminous.
(g) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking, connect to complete cell and provn of through & other accessories.
(h) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside car to alert the persons trapped inside that they are being recued.
(j) Provision of governor and governor rope of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. Grooved Belt and alongwith belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator nearest landing.
(k) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(l) Door sensor not less than 74 beam, 2D infra red full length
(m) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(n) Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown
(o) Do's & Don’ts chart on stainless steel to be installed inside the car cabin.
(p) A three Pin plug socket with switch for hand lamp shall be fitted on top of the lift car for use by person working there on.
(a) LED Light Ultra slim decorative aluminium casted, recess mounted square fixture in white with opal diffuser and separate electronic driver, suitable for low depth ceiling -12W BLAZE SQUARE with complete accessories including necessary wiring - 04 Nos
(b) Single phase centrifugal type cross flow blower 270 cu meter/hour-02 Nos.
(c) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per IS (minimum efficiency class equivalent to IE 2) and operating gearless box with independent main sheave rim.
(d) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(e) Micro processor based VVVF type main controller with closed loop system.
(f) Type of signal system FIGS fixtures with dot matrix display (Touch Panel) and car position indicator in car all fixture in SS face plate (both insided/out-side). All buttons should be with brail marking and luminous.
(g) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking, connect to complete cell and provn of through & other accessories.
(h) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside car to alert the persons trapped inside that they are being recued.
(j) Provision of governor and governor rope of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. Grooved Belt and alongwith belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator nearest landing.
(k) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(l) Door sensor not less than 74 beam, 2D infra red full length
(m) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(n) Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown
(o) Do's & Don’ts chart on stainless steel to be installed inside the car cabin.
(p) A three Pin plug socket with switch for hand lamp shall be fitted on top of the lift car for use by person working there on.
Description of Work / Item(s)
Amount
Demolition of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specifed and directed.
M&L screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.
M&L Machine cut kota stone flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment ot match the shade of the slab including rubbing and polishing complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from frame) area exc 1.50 sqm but n.exc 4.00 sqm each complete all as specified and directed.
S&F MS Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc., to be prepared for hanging or sliding with and including either hooks and hings or steel hanging door fittings (exclusive of steel sheeting or other coveirng, running rails and guides) and hanging, also fastening and fixing complete all as specifed and directed..
Preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat red oxide paint complete all as specifed and directed..
S&F factory made 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specifed and directed.
S&F 100 mm size MS butt hinges medium weight cold rolled complete all as specifed and directed.
S&F 150mm long, aluminium, anodised, barrel tower bolts of extruded section complete all as specifed and directed.
S&F 150mm aluminium handles, cast type, anodised complete all as specified and directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium complete all as specified and directed
M&L for 0.9 mm thick, Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specifed and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads exc 1.5 sqm complete all as specifed and directed.
S&F in repairs 3mm thick sheet glass, ordinary quality and glazing with oil putty in Square n exc 0.5 sqm in each pane complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick/concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specifed and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulusion distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for cleaning of lift pit with wire brush/washing complete all as specifed and directed..
M&L for fixing of 10mm dia grouting nipple upto 75mm depth by drilling with 12mm bore hole & fixing in cement mortar at 600mm c/c.complete all as specifed and directed..
M&L injecting grouting @ 10Kg/Sqm average grout prepared by mixing grout agent/powder with bonding agent by use of Grouting pump @ 10 to 12 Kg/Sqcm pressure complete all as specifed and directed..
Removal of nipple and making fair & fine by using two coats of epoxy adhesive and sealant @ 4Kg/Sqm complete all as specifed and directed..
Description of Work / Item(s)
Amount
Taking down unservicable low tention cable 16 to 35 sqmm from wall/floor complete all as specifed and directed.
Taking down unservicable MCCB 63 Amps to 125 Amps complete with disconnection of all electric connection complete all as specifed and directed.
Supply and laying and testing and commissioning XLPE insulated cable, screened, PVC bedded galvanized steel strip armoured cable heavy duty 1100 volt grade with stranded aluminium conductor laying on wall or in trenches of size 25 Sqmm 4 core complete all as specifed and directed.
Supply and fix TPN 4 Pole MCCB 100 Amp capacity, 50 HZ, 415 volts in replacement with ruptring capacity 25 KA complete all as specifed and directed.
Supply and fixing sheet metal enclosure DB TPN, 4 way, double door in replacement as incomer, IP-43 dust and vermin proof, vertical type suitable for MCCB as incomer duly fixed on wall on angle iron frame in and including following items complete all as specifed and directed.. :- (i) MCCB 100 Amps, TPN, 25KA, 50Hz, 415 volts with Thermal magnetic release-01 Nos (ii) RCCB/ELCB, 40 Amps, 300mA, 4 pole-02 Nos (iii) MCB, 25 Amps, 10 Ka, SPN-02 Nos (iv) Phase sequence corrcetor-01 Nos
Excavation in trenches in soft/loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out complete all as specifed and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specifed and directed.
Removal of excavated material not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as directed.
M&L Sand cushioning for UG cable protection/ducts, consolidated sand compacted with clean dry sand complete all as specifed and directed.
Supplying & layng sub class 'B' bricks common burnt laid in trenches for cable protection complete all as specifed and directed.
S&F of GI pipe of 40mm nominal dia light grade in replacement fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specifed and directed..
M&L for earthing complete in replacement with galvanized steel plate electrode 60cmx60cmx6mm thick burried directly in ground, earth pit not less than 2.25 mtr deep and top edge of plate not less than 1.25 mtr below ground level and connected to GI earth lead wire 4mm dia fixed by means of nuts bolts etc, connected to earth test point surrounded by packed alternative layers of charcoal and common salt 15cm thick all around top and bottom complete all as shown in plate No. 3 to the earthing test point all as specified and indicated including provn of PCC chamber 1:3:6 using 20mm graded stone aggregate, 50mm thick cover with RCC 1:2:4 type B-1 using 8mm dia TMT bars @ 100mm C/C both ways as in reinforcement, necessary excavation earthwork, returning filling and testing on completion etc all as specified and directed.
Taking down old unservicable point wiring from existing conduit/batten type (light, fan, socket or power point) complete such as switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface of wall/floor/ceiling etc as original i.e brick work, plastering, white washing complete all as specifed and directed.
M&L for point wiring complete with 1.5 Sqmm (nominal area) single core PVC insulated, FRLS, cable 1100 volt grade with multi stranded copper conductor drawn through and including non-metalic rigid New PVC conduit medium grade ISI marked and all conduit accessories in wall on surface in celing/fixed to roof/truss/columns etc and including provision of 1.5 Sqmm PVC insulated copper cable FRLS as earth continuty, fabricaed modular metal flush box concealed in wall with sutiable modular inner and outer plate for housing switches, sockets outlet and fan regulators etc.complete all as specifed and directed.
All as per Item Sl. No. 14.00 above but point wiring for one socket outlet point 5 amps on the same board complete all as specifed and directed.
All as per Item Sl. No. 14.00 above but point wiring for one socket outlet point 5 amps on the independent boardcomplete all as specifed and directed.
All as per Item Sl. No. 14.00 above but point wiring with 2.5 Sqmm FRLS copper cable for socket outlet point 15 Amps on the independent board complete all as specifed and directed.
Taking down carefully any type of submain wiring including make the good surface with matching the existing surface complete all as specifed and directed.
M&L for sub main wiring with 2 run of 6.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit medium grade 25mm dia minimum wall thickness 1.6mm with 6.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed stranded DB to sub main DB complete all as directed. Note:- The two run of 6 sqmm wire, one run of 6 sqmm wire and 1 mtrs length PVC conduit measured as one unit.
S&F in replacement of Modular switch 6 Amps, 1 Way, 1 module size complete all as specifed and directed.
S&F in replacement of Modular socket 6 Amps, 2/3 pin, shuttered type, 2 module size complete all as specifed and directed.
S&F in replacement of Modular switch 16 Amps, 1 Way, 1 module size complete all as specifed and directed.
S&F in replacement of Modular socket 6/16 Amps, 6 pin, shuttered type, 2 module size complete all as specifed and directed.
S&F in replacement of ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps with and making good surface as original by plastering and whitewash/colour/distemper etc complete all as specifed and directed.
S&F in replacement of MCB C Curve type, 10Ka, 10 to 32 Amp, single pole with over load and short circuit protection complete all as specifed and directed.
All as per Item Sl. No. 25.00 above but of 32 Amp capacity and SPN type.
S&F in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB's and isolators etc and making all necessary connections complete all as specifed and directed.
Taking down carefully any type of exhaust fan including make the good surface width matching the existing surface complete all as specifed and directed. Note:- Old exhausast fans shall be deposit in AGE E/M store yard.
S&F of Exhaust fan 300 mm sweep metal body heavy duty with louvers and making all electric connections complete all as specifed and directed.
S&F in replacement of Indoor decorative wall mounting LED 20 W extruded aluminium batten with opal diffuser including LEDs complete and making all electric connections complete all as specifed and directed.
M/S N.K BUILDERS
V S BUILDER
Choice india
M/S N.K BUILDERS
V S BUILDER
Omega Elevators
Choice india
V S BUILDER
Omega Elevators
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .