Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹3.7 L+₹13,505 (3.75%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹4.0 L+₹42,855 (11.9%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | IMPLA GENERAL SUPPLIERS L2 | M/S SHUJAT ELECTRICALS MECHINICALS AND SUPPLIERS L1 | GEC ELECTRICALS L3 |
|---|---|---|---|---|---|---|
| 1.00Work items identified; | ||||||
| 1.01 | Supply,Installation ,testing and commisioning of 9mtr (410 SP-33) long Steel Tubular Poles complete with base plate(350x350x5mm), top cap, Earthing Channel(75x40x6) including digging of pit positioning etc, complete in all respect as per Standards. | 11 | Nos. | 15,500 ₹1,70,500 Lowest | 18,000 ₹1,98,000 | 17,000 ₹1,87,000 |
| 2.01 | Supply,Installation ,testing and commisioning of 8 mtr (410 SP-15) long Steel Tubular Poles complete with base plate (350x350x5mm), top cap, Earthing Channel(75x40x6) positioning etc, complete in all respect as pe Standards. | 1 | Nos. | 11,000 ₹11,000 Lowest | 11,000 ₹11,000 Lowest | 14,000 ₹14,000 |
| 3.01 | Supply,laying, stringing, tensioning, binding of 50 Sqmm ACSR Conductor complete in all respects as per standards. | 1.3 | Km. | 50,000 ₹65,000 | 20,000 ₹26,000 Lowest | 50,000 ₹65,000 |
| 4.01 | Supply, laying, stringing, tensioning, binding of 30 Sqmm ACSR Conductor complete in all respects as per standards. | 0.08 | Km. | 30,000 ₹2,400 | 20,000 ₹1,600 Lowest | 30,000 ₹2,400 |
| 5.01 | Supply Carraige upto site, fixing of
GI V cross-arm with top Bracket including clamp duly fabricated as per site requirement including clamps(50x8 mm), GI Nuts & Bolts,washers etc complete in all respects as per standards. | 607 | Kg | 125 ₹75,875 | 110 ₹66,770 Lowest | 135 ₹81,945 |
| 6.01 | Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV porecelain composite Pin Insulators 12 kv, 5KN, Lighting impulse 75 Kv positive and 80 Kv negative, Creepage distance 320mm complete in all respects as per standards. | 51 | No. | 180 ₹9,180 | 150 ₹7,650 Lowest | 150 ₹7,650 Lowest |
| 7.01 | Supply,Carraige upto site,Installation,testing and Commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm as per standards. | 2 | No. | 200 ₹400 | 50 ₹100 Lowest | 100 ₹200 |
| 8.01 | Supply, Carraige upto site, installation, testing and Commissioning of 11 kV G.O AB Switch 3-phase, 3 pole 200-Amp, vertical Type with fittings complete in all respects as per standards. | 2 | No. | 8,500 ₹17,000 Lowest | 8,900 ₹17,800 | 11,000 ₹22,000 |
| 9.01 | Supply,Carraige upto site and installation of Galvanised nuts and Bolts. | 6 | Kg. | 100 ₹600 Lowest | 130 ₹780 | 110 ₹660 |
Tender Value
₹4.6 L
EMD Value
₹9,200
Closing Date
20 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, ED Budgam, KPDCL
ED Budgam, KPDCL
improvement and shifting of HT network under CDF under the jurisdiction of ED Budgam.
2026_PDD_302697_1
EDB/121 of 2025-26
Open Tender
Electrical and Maintenance Works
Turn-key
30 days
ED Budgam, KPDCL
AS PER SBD
7 documents required · 7 mandatory
₹200
Executive Engineer, ED Budgam, KPDCL
₹9,200
24 Feb 2026
9 Feb 2026
21 Feb 2026
9 Feb 2026
20 Feb 2026
10 Feb 2026
9 Feb 2026 - 10 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Work items identified; | |||||
| 1.01 | Supply,Installation ,testing and commisioning of 9mtr (410 SP-33) long Steel Tubular Poles complete with base plate(350x350x5mm), top cap, Earthing Channel(75x40x6) including digging of pit positioning etc, complete in all respect as per Standards. | 11 | Nos. | -1 | - |
| 2.01 | Supply,Installation ,testing and commisioning of 8 mtr (410 SP-15) long Steel Tubular Poles complete with base plate (350x350x5mm), top cap, Earthing Channel(75x40x6) positioning etc, complete in all respect as pe Standards. | 1 | Nos. | -1 | - |
| 3.01 | Supply,laying, stringing, tensioning, binding of 50 Sqmm ACSR Conductor complete in all respects as per standards. | - | Km. | -1 | - |
| 4.01 | Supply, laying, stringing, tensioning, binding of 30 Sqmm ACSR Conductor complete in all respects as per standards. | 0.08 | Km. | -1 | - |
| 5.01 | Supply Carraige upto site, fixing of
GI V cross-arm with top Bracket including clamp duly fabricated as per site requirement including clamps(50x8 mm), GI Nuts & Bolts,washers etc complete in all respects as per standards. | 607 | Kg | -1 | - |
| 6.01 | Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV porecelain composite Pin Insulators 12 kv, 5KN, Lighting impulse 75 Kv positive and 80 Kv negative, Creepage distance 320mm complete in all respects as per standards. | 51 | No. | -1 | - |
| 7.01 | Supply,Carraige upto site,Installation,testing and Commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm as per standards. | 2 | No. | -1 | - |
| 8.01 | Supply, Carraige upto site, installation, testing and Commissioning of 11 kV G.O AB Switch 3-phase, 3 pole 200-Amp, vertical Type with fittings complete in all respects as per standards. | 2 | No. | -1 | - |
| 9.01 | Supply,Carraige upto site and installation of Galvanised nuts and Bolts. | 6 | Kg. | -1 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.62 MB
Tendernotice_2.pdf
PDF • 1.60 MB
BOQ_982457.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .