Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.7 LAccepted-AOC ARA P O GANESHPUR DIST LATEHAR PIN 829202 | LATEHAR | JHARKHAND | 829202 | L-1 | Accepted-AOC As per recommendation of TC and approval of competent authority | |
| 2 | L-2₹1.7 L+₹29,319 (20.6%)Rejected-Finance RAHAM TANDWA DISTT CHATRA PIN 825321 | CHATRA | JHARKHAND | 825321 | L-2 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 3 | L-3₹2.6 L+₹1.1 L (80.5%)Rejected-Finance | L-3 | Rejected-Finance As per recommendation of TC and approval of competent authority |
Tender Value
₹1.7 L
EMD Value
₹2,100
Closing Date
6 Nov 2023, 5:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area, Bachra 829201.
Extension of power by errection of 16 meter tubular pole for fitting of 200 watt light and to feed power to high mast tower light towards entry point of mines near Chamatu view point with wiring of view point shelter under Magadh OCP, M-S Area
2023_CCL_292075_1
GM(MS)/SO(EnM)/e-NIT/23-24/115
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Office of the Project Officer M-S Area, Bachra
Please Refer NIT
4 documents required · 4 mandatory
₹2,100
8 Feb 2024
27 Oct 2023
7 Nov 2023
27 Oct 2023
6 Nov 2023
27 Oct 2023
27 Oct 2023 - 3 Nov 2023
Amount
Erection of metallic pole of length above 10mtr and upto 12 mtr in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Erection of angle Iron/channel iron cross arm on 4 wood/RCC/PCC/steel tubular or Rail pole for 2 wire system.
Supplying and erection of 100 mm x 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required.
Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required.Group B
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" curve, miniature circuit breaker single pole and 12 neutral for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and providing 13 masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for vloop earthing as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
16 supply of Led tube light 18 watt
Supply of LED Bulb 9 watt
Supply of wall mounted fan 450 mm
Total impact of GST for the purpose of CTC
M/S HEMANT KUMAR YADAV
M/S RABINDRA KUMAR
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_302538.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .