| 1 | L1₹17.2 LAccepted-AOC | ₹17.2 L Quoted ₹17.7 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹21.2 L+₹3.5 L (20.0%)Rejected-Finance | ₹21.2 L+₹3.5 L (20.0%) | L2 | Rejected-Finance BEING NOT L1 |
| 3 | L3₹21.4 L+₹3.7 L (21.2%)Rejected-Finance | ₹21.4 L+₹3.7 L (21.2%) | L3 | Rejected-Finance BEING NOT L1 |
| 4 | L4₹21.4 L+₹3.8 L (21.3%)Rejected-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | ₹21.4 L+₹3.8 L (21.3%) | L4 | Rejected-Finance BEING NOT L1 |
| 5 | L5₹21.6 L+₹3.9 L (21.9%)Rejected-Finance | ₹21.6 L+₹3.9 L (21.9%) | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Jul 2024, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR/ REPLACEMENT TO UNSERVICEABLE PIPE LINE/ PUMP SET/ BOREWELL IN EXTERNAL WATER SUPPLY MAINS AT 11 BRD AF STATION OJHAR
2024_MES_661893_1
8185/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹40,000
Yes
1 Oct 2024
25 Jun 2024
17 Jul 2024
26 Jun 2024
15 Jul 2024
9 Jul 2024
Amount
Excavation in trenches n. exc 1.5 Mtr width and n.exc 1.5 mtr deep for foundation, laying GI pipes in soft/loose soil and getting out,complete all as specified and as directed by Engineer-In-Charge.
All as per item no-1 above but in hard dense soil,
Returning filling in incl spreading leveling watering and well ramming in layers not exceeding 25 cm levers of soil, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point, complete all as specified and as directed by Engineer-In-Charge.
Taking up or down old rusted water tubing and connections fixed to wall floor, celing for bore of 15 mm dia , complete all as specified and as directed by Engineer-In-Charge.
All as per item no-5 but bore 20 mm dia
All as per item no-5 but bore 25 mm dia
All as per item no-5 but bore 40 mm dia
All as per item no-5 but bore 50 mm dia
All as per item no-5 but bore 80 mm dia
Supply & Fix GI water tubing medium grade with all fitttings and fixed to wall, floor, ceiling for bore of 15 mm diameter, complete all as specified and as directed by Engineer-In-Charge.
All as per item no 11 above but of bore 20 mm dia
All as per item no 11 above but of bore 25 mm dia
All as per item no 11 above but of bore 40 mm dia
All as per item no 11 above but of bore 50 mm dia
Supply, laying, jointing and testing GI water tubing medium grade with all fitttings in trenches for bore of 15 mm diameter, complete all as specified and as directed by Engineer-In-Charge.
All as per item no 16 above but of bore 20 mm dia
All as per item no 16 above but of bore 25 mm dia
All as per item no 16 above but of bore 40 mm dia
All as per item no 16 above but of bore 50 mm dia
All as per item no 16 above but of bore 80 mm dia
Fixing only old serviceable water tubing medium grade received from item No 5 here in before and connected with new fittings of medium grade as required including cleaning, cutting, threading and fixed to wall, floor, ceiling for bore of 15 mm diameter , complete all as specified and as directed by Engineer-In-Charge.
All as per item no 22 above but of bore 20 mm dia
All as per item no 22 above but of bore 25 mm dia
All as per item no 22 above but of bore 40 mm dia
All as per item no 22 above but of bore 50 mm dia
Supply & Fix in replacement of Bronze gate valve (Hex type) ISI marked screwed both ends of 50 mm diameter Art No 1006 of Make: Zoloto or Equivalent in Leader/L&T complete all as specified and as directed by Engineer-In-Charge.
All as per item no 27 above but of bore 40 mm dia
All as per item no 27 above but of bore 25 mm dia
All as per item no 27 above but of bore 20 mm dia
All as per item no 27 above but of bore 15 mm dia
Material & Labour for carring out repairs to Existing Star delta starter in open execution ,identifying the fault in wiring,rectifying the wiring fault using suitble flexible copper cable Replacement of time delay(timer), single phasing preventer & suitable relay with new one(as required as per its specification or as specified by Engineer -In Charge) ,rewiring of complete starter using suitable size flexible copper cable, suitable upto 60 HP electric motors and testing of electrical circuit/Pumpset to the complete satisfaction of Eng-In-Charge,complete all as specified and as directed by Engineer-In-Charge.(Note :Spares required other than mentioned above in the process of maintenance will be measured and paid separately under relevant item mentioned here after
Supply & fix in repair Contactor ML-02 Aux coil voltage 230 V , Make L&T or Equivalent in Siemens/Standard complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. item no 33 above but Contactor ML-03,Aux coil voltage 230 V
All as per Sl.item no 33 above but Contactor ML-04, Aux coil voltage 230 V
Material & Labour for repair &overhauling of non clogging pumpset Make :Grundfos :Model No SE1.75.100.150.2.52S.C.N.51D Resulting head of the pump: 20.3 m, flow 48.2 LPSType of impeller: S-TUBE , Primary shaft seal: SIC-SIC, Secondary shaft seal: SIC-CARBON, Pump housing: Cast iron EN-GJL250,Impeller: Cast iron EN-GJL250, Motor: Cast iron EN-GJL250, Material: Whole pump in cast iron, Maximum,current consumption: 29 A,insulation class H, Power input - P1: 17 kW, Rated power - P2: 15 kW, Mains frequency: 50 Hz, installed at STP dry installation ,taking down the pump set carefully with the help of crane from existing position with connected electric motor transporting the pumpset to authorised dealers workshop with following replacement/repairs of pump set (a) opening it through its casing For Dismantling pump and motor and carrying out repairs/overhauling including cleaning of casing and impeller, clogged, discharge line and oil chamber (b) Taking out the electric motor overhauling ,warnishing of the same (c) Repairing of Sleeve of the bearing & Repair of any major or minor defects (c) Refixing and recommissioning of pump with motor in proper alignments and recommissioning and test run from authorised rep of company ,testing the pump set to the complete satisfaction (2 yrs performance warranty shall be submitted for pumps) Complete all as specified & as directed by Engineer in charge .(Replacement of following spare part mentioned hereafter in the process of maintenace will be measured & paid separately) Note:- Item mentioned under Sl no- 36 to 42 are to be executed from authorized dealer appointed by OEM exclusively. Item no 37 to 42 are the spare required in the process of maintenance which shall be measured and paid separately
Supply & fix shaft seal cartridge
Supply & fix Bearing Set
Rewinding of motor with suitable gauge copper windinding of Insulation class (IEC 85): H
Supply & fix O-Ring set for dry motor NBR
Supply & fix S moisture switch kit
Supply & fix Leakage switch
M& L for Pumping out continously raw sewage water & cleaning of underground collection pit of size 5.2 mtr x 5.2 mtr and 4.8 mtr deep by removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side walls of sewage well with the help of wire brush. Stacking out complete sludge and silt at distance not exceeding 50 mtr from the pump house. Applying two coats of lime wash on side walls of sewage walls on interior & weather proof apex over primer on exterior surfaces of sewage wall and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome,pumpset & associated pipeline with synthetic enamel paint as directed by Engineer-In-Charge
Material & Labour for structral steel work with MS channel ,angles,tees,beam,plate,pipe for fabricationof ladder ,manhole ,valve chamber,railing including fabrication work i.e welding,cutting drilling,jointing work and painting two coats of synthetic enamel paint over one coat of red oxide and fixing same at desire location, complete all as specified & as directed by Engineer-in Charge
Material & labour for fitting for spigot socketed CI pipes Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc,) Tee pieces single branch. "Y" juction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 300 mm bore including welding the same at desired location & taking out unserviceable fitting from existing position ,complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix flexible pipe both end screwed brass nuts of size 15mm dia having length of 300mm suitable for hot water connection,complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix in replacement of Bib tap with Forged brass ball Bib cock(Chrome Plated) of size 15 mm bore Art no 1022A of Make: Zoloto or Leader/L&T ,complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix in replacement of Bronze ball valve with integral strainer both end screwed of size 15 mm bore Art no 1008 of Make: Zoloto or Equivalent in Leader/L&T ,complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends all as specified and as directed of size 15 mm bore Make: Zoloto or Equivalent in Leader/L&T,complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix PVC BIB COCK STANDARD of size 15 mm (white) , Make - PRAYAG/Jaguar or Equivalent complete all as specified and as directed by Engineer-In-Charge.
Supply & Lay CPVC pipes SDR 11 & Plain CPVC SDR 11 fitting in 40 mm dia trenches/surface for hot water complete all as specified & directed by Engineer-In-Charge.
Material and labour for prepration of new steel surfaces of any description and applying two coats of synthetic enamel paint over one coat of red oxide ,complete all as specified & as directed by Engineer-In-Charge
Supply and fix in repair cast iron foot valve 100 mm dia with flange end with replacement of existing foot valve.of make: Zoloto/Kirloskar/Leader ,complete all as specified & as directed by Engineer-In-Charge
Supply & Fix in repair Non return valve (NRV) of 100 mm dia bore size both end flanged confirming to PN -1.0 rating ,Make : make: Zoloto/kirloskar/Leader ,complete all as specified & as directed by Engineer-In-Charge
S/F fitting for spigot socketed MS pipes Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc,) Tee pieces single branch. "Y" juction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 300 mm bore including welding the same at desired location all as specified and directed by Engineer-in -Charge
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20 mm,complete all as specified & as directed by Engineer-In-Charge.
Supply & Fix in repair Butterfly valve wafer type made up of SG iron,without Lugs,Lever operated,SG iron Disc,Nitrile /Rubber linning/Neoprene lining,Test pressure PN-10/PN-16 150 mm Art No 1078 of Make: Zoloto /Leader /Kirloskar, complete all as specified and directede by Engineer-In-Charge.(Rates quoted are deemed to be included with cutting existing 150 mm MS/HDPE pipe to accomodate butterfly valve,inserting suitable flanges,rubber gaskets,nuts bolts,making necessary welding work & testing the pipeline for trouble free operation)
Material & labour to collect waste(sewage) water sample from domestic area 11 BRD in container,sending it to govt approved NABL accreditted lab , to carry out chemical analysis as well as & phisical parameter & bacteriological parameter test from approved lab & rate quoted are deemed to be quoted with this item.) (Note : - Report from approved NABL lab shall be submitted (Testing of sample before treatment & after treatment will be treated as one job ) for following parameter (i) BOD (ii) COD (iii)SS (iv) Ph:7-8 (v) Outlet coliform (vi)Residual chlorine) , complete all as specified and as directed by Engneer-in-Charge.
Material & labour to collect water sample from Rakshanagar/ Technical area 11 BRD in container,sending it to govt acreditted NABL lab , to carry out chemical analysis as well as organoleptic & physical & General Parameters & bacteriological parameter Including Residual free Chlorine test from approved lab Every month & rate quoted are deemed to be quoted with this item.) (Note 3: - Report from approved NABL lab shall be submitted by 15th of the Month.)
M&L for removal green vegetation, cutting of tree with girth not more then 10 cm from water supply installation as STP-1, STP-2, Tech area pump house, Raksh nagar Pump house, MAP Sub stn incl disposal of cut material not more than 50 mtr distance and levelling surface the ground complete all as specified and as directed by engr- in- charge.( Approx artea - 300 SQM)
S& F Fan motor suitable as per sample for swimming pool
S& F 'O Tolidine re-agent suitable as per sample for swimming pool
S& F Glufosinate ammonium 13.5% W/W SL enclosed in plastic container of 1 Ltr suitable as per sample
S& F relay suitable for existing 1 to 3 HP motor suitable as per sample for swimming pool
S& F Tyre coupling with fittings suitable as per sample for swimming pool complete all as specified and as directed by Engr- In- Charge
Excavation in trench and taking out the leakage pipe line of size 300/150/80 mm and repair the same by replacement of water mains/pipe with joint any type of suitable size compleet all as specified and as directed by engr in charge . (Note Pipe line will be measusered and paid separately.)
M&L for preparation of old painted surface of GI/CI pipe 150mm line and painting with two coats of waether proof apex paint in colour as directed by engr in charge.
M&L for taking down existing MS C class pipe / GI/ CI pipe 40 mm to 100 mm from (all along the stone wall) existing position, replacement / repairing its MS support/ supporting structure with suitable new MS angle supports, clamps, nut bolt and washers etc and preparation of old painted surface of GI/CI pipe 100/80 mm0mm line and painting with two coats of waether proof apex paint in colour as directed by engr in charge.
M&L for re-winding of 1 HP motor
M&L for re-winding of 2 HP motor
M&L for re-winding of 3 HP motor
Material & labour to collect waste water and sludge sample from ETP technical area 11 BRD in container,sending it to govt acreeditted NABL lab/MPCB lab , to carry out chemical analysis as well as phisical parameter test from approved lab for following parameter (i) BOD (ii) COD (iii)total suspended solid (iv) Ph:7-8 (v) Cynide (vi)Nickel vi) Chromium Viii) Acidity ix) Alkalinity and collecting electroplating waste sludge (150 Kg approx) cake from ETP plant for disposal and depositing the sludge cake to Maharashtra Enviro power Ltd- Pune for its further disposal & depositing its receipt to Engineer-In-Charge, complete all as specified and as directed by Engneer-in-Charge.
Supply & Fix in repair Butterfly valve wafer type made up of SG iron,without Lugs,Lever operated,SG iron Disc,Nitrile /Rubber linning/Neoprene lining,Test pressure PN-10/PN-16 150 mm Art No 1078 of Make: Zoloto /Leader or Equivalent in kirloskar, complete all as specified and directede by Engineer-In-Charge.(Rates quoted are deemed to be included with cutting existing 150 mm MS/HDPE pipe to accomodate butterfly valve,inserting suitable flanges,rubber gaskets,nuts bolts,making necessary welding work & testing the pipeline for trouble free operation)
Supply and fix in repair Rotational moulded polyethylene water storage tanks of capacity 5000 Litrs (Cylindrical vertical with closed top) hoisted, complete all as specified & as directed by Engineer-in Charge Make : Sintax/ Himalaya/ Polycon
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20 mm,complete all as specified & as directed by Engineer-In-Charge.
S&F Straight plain brass ferrules (or connecting screw) screwed both ends and fixed 20 mm dia,complete all as specified & as directed by Engineer-In-Charge.
Supply,install in repair Digital water,meter type A,of size 50 mm dia with strainer duly fixed on 50 mm GI pipe of Make Kranti / Capstan with necessary fittings , including taking down old unserviceable meter from existing position, Complete all as specified & as directed by Engineer -in-Charge.
S/F fitting for spigot socketed MS pipes Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc,) Tee pieces single branch. "Y" juction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150 mm bore including welding the same at desired location all as specified and directed by Engineer-in -Charge
Supply & fix in repair for MS tubing 40 mm bore (internal) heavy grade class 'C' complete with class 'C' fittings such as bends,Elbow,Tees etc. duly welded to each other for carrying compressed air supply at pressure 7 Kg per sq cm including leak testing of the same & laying in trenches ,fixing on wall / floor/ceiling with necessary clips, clamps and saddles etc. including painting to pipe line with two coats of synthetic enamel paint over one coat of Red Oxide primer including the colour code as specified in relevent IS, complete all as specified and as directed by Engineer-In-Charge.
Supply only pig lead wool ,complete all as specified and as directed by Engineer-In-Charge.
Repairs to submersible pump of 50 LPM capacity Make KSB coupled with electric motor 3 PH 440V , 50Hz, 3.0 hp capacity 1400 RPM after disconnecting the electric connections,taking pumpset out of borewell dismantling pump and motor and carrying out repairs/overhauling which shall include cleaning of casing and impeller, clogged, discharge line and oil chamber and replacement of suitable size oil seal and reassebling the pump set installing connection up and testing all as specified and directed by Engineer-in-Charge. (a) Replacement of bearings (Make SKF) of suitable size.(b) Replacement of main spindle shaft of suitable size(c) Replacement of bush cast alloy of suitable size.(d) Replacement of oil seal set complete.(e) Replacement of main spindle shaft sleeve of suitable size.(f) Replacement of key and impeller of suitable size.(g) Replacement of MS coupling with tyre coupling including drilling required size of hole on either side. '(h) Replacement of terminal plate for electric motor.'(j) Replacement of oil seal for pump of suitable size.'(k) Refixing and recommissioning of pump with motor in proper alignments,painting two coats of synthetic enamel paint over one coat of red oxide and testing the pump set to the complete satisfaction of Engineer-in-Charge.
Material & Labour for structural steel work with MS channel ,angles,tees,beam,plate,pipe for fabricationof ladder ,manhole ,valve chamber,railing including fabrication work i.e welding,cutting drilling,jointing work and painting two coats of synthetic enamel paint over one coat of red oxide and fixing same at desire location, complete all as specified & as directed by Engineer-in Charge
Material and labour for Rectification of leakage of GI pipes of 15 mm upto 25 mm dia laid in trenches/ on floor/ fixing to wall etc. of any size including excavation, earthwork, dewatering and removal of mud or pumping out water etc. by replacing of unserviceable GI fittings like elbow, union, sockets, tees, nipple etc. of appropriate sizes and GI pipes of the existing sizes upto 01 Metre length (ISI MARKED) complete all as specified and as directed Notes:- (a) New GI Pipe more than 01 metre length if required will be measured and paid separately.
Material and labour for Rectification of leakage of GI pipes of 25 mm upto 80 mm dia laid in trenches/ on floor/ fixing to wall etc. of any size including excavation, earthwork, dewatering and removal of mud or pumping out water etc. by replacing of unserviceable GI fittings like elbow, union, sockets, tees, nipple etc. of appropriate sizes and GI pipes of the existing sizes upto 01 Metre length (ISI MARKED) complete all as specified and as directed Notes:- (a) New GI Pipe more than 01 metre length if required will be measured and paid separately.
Material and labour for Rectification of leakage of CI/DI pipes of 80 mm to 150 mm dia laid in trenches/ on floor etc. including excavation and eartwork, dewatering and removal of mud or pumping out water etc. by replacing of unserviceable CI fittings and CI pipes of the existing size up to 01 metre length or cocking of lead wool in joints or replacing of rubber gaskets etc. (ISI MARKED) complete all as specified and as directed Notes:- (a) CI Fittings, CI Pipes more than 01 metre length and lead joints incorporating with the job will be measured and paid separately.
Material and labour for Rectification of leakage of CI/DI pipes of 150 mm to 300 mm dia laid in trenches/ on floor etc. including excavation and eartwork, dewatering and removal of mud or pumping out water etc. by replacing of unserviceable CI fittings and CI pipes of the existing size up to 01 metre length or cocking of lead wool in joints or replacing of rubber gaskets etc. (ISI MARKED) complete all as specified and as directed Notes:- (a) CI Fittings, CI Pipes more than 01 metre length and lead joints incorporating with the job will be measured and paid separately.
Supply and laying DI pipe 150 mm bore dia centrifugally cast class 'K-7' laid in trenches/ wall / overhead tank of any length of following sizes complete all as specified and directed (DI fittings and jointing materials shall be measured and paid separately)
Supply and laying DI pipe 100 mm bore dia centrifugally cast class 'K-7' laid in trenches/ wall / overhead tank of any length of following sizes complete all as specified and directed (DI fittings and jointing materials shall be measured and paid separately)
M&L for rubber gasket joint suitable of DI pipe and fittings with size of nuts, washer & bolts etc complete all as specified and directed for the sizes:- 150mm bore dia
All as per item above but 100mm bore dia
M&L for upto 150mm bore cast iron (CI)/ Ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed. Make :- Kesoram, Kejriwal.
M&L for rewinding of Booster Pump set motor of capacity 2 HP to 3 HP with suitable gauge of super enamelled copper winding wire after cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge
Supply & Fix in repair Vacuum pump of 50 LPM capacity Make :Kirloskar Model No DV40 coupled set GP with electric motor 3 PH 440V , 50Hz, 5.0 Hp capacity 1450 RPM,Suction delivery size 40 mm ×40 mm size & able to develope vacuum of 0 to 600 mm of Hg at air flow rate of 8-73 cu.m /hr ,including mounting it over new MS base plate/Chasis,Fixing it in PCC Type C2 1:3:6, making necessary inlet/outlet connections with existing pumpset using requisite size GI pipe gate valves & fitting,making necessary electrical connection using requisite size XLPE cable & DOL starter,providing necessary and commissioning of pump with motor in proper alignments,painting two coats of synthetic enamel paint over one coat of red oxide and testing the pump set to the complete satisfaction of Engineer-in-Charge.
M&L for rewinding of Booster Pump set motor of capacity 4 HP to 5 HP with suitable gauge of super enamelled copper winding wire after cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge
Dismantling & taking out defective parts of booster pump set of capacity 0.5 HP to 1.5 HP and refixed after repairs / making complete serviceable by repairing / replacement of defective parts including tranportation to local work shop etc complete all as specified and directed by Engineer-in-charge. Note : - Parts replaced if any shall be paid under relevent items of the schedule
M&L for rewinding of Booster Pump set of capacity 0.5 Hp to 1.5 HPwith same gauge of super enamelled copper winding wire after cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge
S&F in replacement old Running Capacitor 10.0 MFD
S&F in replacement old Running Capacitor 25.0 MFD
S&F in replacement old Running Capacitor 36.0 MFD
S&F in replacement old Running Capacitor 50.0 MFD
M&L for replacement of pressure booster pump 1 HP capacity single phase, 50 Hz mounted on roof for boosting water supply to high pressure and connected with existing water supply pipe line including necessary electrical wire and plug top , NRV socket alll as specified and directed by Engr -in-Charge.
Material & Labour for taking down pumpset upto 25 HP from its existing position by dissconnecting its inlet and outlet replacing its old base over new MS base plate/Chasis,Fixing it in PCC Type C2 1:3:6, making necessary inlet/outlet connections with existing pumpset
M& L for Cleaning of Suction room of painting bay at Tech area complete incl suction fume filter , sprinkling system and nozzle including suction duct from from painting bay to Suction room incl all connected parts complete for smooth function of the system. Note -(1) All necessary T&P such as air compressor, blower, pressure pump , ladder etc as required at site are included in quoted rates . (2). The rates for dismantling and refixing of connected machineries during cleaning are included in quoted rates.
S& Fixing DOL starter suitable upto 2 HP water pump as per existing make and model complete all as specified and as directed by Engineer-In-Charge.
S & F in replacement of electronic digital water level indicator wireless communication between tank and pump house 180-260 V, 50 Hz with seven segment red LED display visible board (2.25 inch) high frequency non conducting processor based rust free with three wire system, range of 1 KM from the OHT to pump house, processor based senser at OHT, sensing probe in the tank including three core data shield cable of suitable size upto transmitter, water level indicator electrically operated with indications of level of water in RCC over head tank comprising of one number for each RCC over head tank (capacity up to 1.5 lakh gallons) of staging height up to 25 m and Electronic water level indicator installed at pump house building for smooth functioning complete all as specified and directed.
M&L for Repair to PU/PP/PVC foot valve of dia 150 mm at swimming pool by taking it out from existing position(Sump),transporting it to workshop ,reparing the PVC mesh and ball complete ,rivetting and reinforcing stainless steel support to the foot valve to avoid its buckling/bending,making it serviceable , complete all as specified and as directed by Engineer-In-Charge.
Material & labour for taking down existing butterfly valve from existing position ,checking its collar and flanges/bends,identifying the leakages,replacing damage piece of pipe,bend/flage/collar of NB 150 mm with new one,supply and fixing suitable size HDPE pipe tail piece & stub bend flange to mount over existing NB 150 mm size HDPE pipe, making and fusion joint using suitable type of heater so as to ensure leak proof operation ,incorporating suitable MS clampto ensure leak proof fuctioning incorporating SS 316 nut bolts & washer for fixing valve and testing for leak proof fuctioning , complete all as specified and directede by Engineer-In-Charge
Supply and fix in repair reciprocating chlorine chemical dosing pump 0-100 psi, out put 2US GPD-40 US GPD, RPM-44, Single phase 230 Volt, 50 Hz with all acessories including suspension tank 100 Ltrs, FRP coated single phase electric motor, agitator with shaft & impeller complete all as directed. Make: Declibec
Material & Labour for taking down pumpset from site Model No NSRP50TBGVIL of Make ANTICO ,transporting it to workshop ,complete servicing replacement of its casing ,replacement of shaft & impeller bringing it back to site,installilng and testing complete for leakage free operation and satisfactory working of the plant, complete all as specified and as directed by Engineer-In-Charge
M/S ANAND G NUNSE
BHAVIN INFRA
Shree Sai Samarth Enterprises
OM SAI ASSOCIATES
M/s Lakhanpal construction company
M/S MK Nair
Apachi Systems
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .