Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC PLOT NO 4 SUDARSHAN ROW RESIDENCY GAWADE MALA PIPELINE ROAD SAVEDI AHMEDNAGAR 414003 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414003 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹51.8 L+₹2.8 L (5.76%)Rejected-AOC | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN CAT c(i) | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN CAT c(i) | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN CAT c(i) |
Tender Value
₹49 L
EMD Value
₹96,000
Closing Date
28 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF LOHEGAON
GE AF LOHEGAON LOHEGAON PUNE-411032
REPAIRS, MAINTENANCE OF PERIMETER LIGHTS, SECURITY LIGHT,HIGH MAST LIGHT IN TECH AREA, OMQ AND NP AREA,WSA, REPAIIR TO COOLING APPLIANCES AT 7TETRA, AFLU AND P ANDS, ALLIED UNITS AT SOUTH SIDE OF 2WING AT AFS PUNE UNDER GE AF LOHEGAON
2023_MES_602407_1
8722
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
TECH AREA, OMQ NP AREA, WSA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹96,000
Yes
19 Sept 2024
10 Jun 2023
29 Jun 2023
10 Jun 2023
28 Jun 2023
23 Jun 2023
Amount
Labour & Tools incl ladders to attanding general street light complaints for repair/maint of street light/fllood light fitting any type and capacity after taking out from poles upto 11 mtrs height any place within the stn checking throughly function of drivers and connected item , removing carbon on joints, repairing of cable joints/loose connection , making soldering etc incl replaceent of of small parts ike wire upto 1.5 mtr long, nut bolts, screws, insuation tape etc fixing on pole after carry out necessary repairs and testing for smooth functioning complete Note :- (a) repairs may be carryed out as an when required basis on site i.e number of times and shall be measured and paid as per site requirement as per satisfaction of Engr-in - Charge and spare parts like electronic drivers, ballast, lamp , ignator etc shall be measured and paid separately in respective items. (a) Contractor shall be provide ladder for repairing of street light and hanger light fittings. (b) Contactor shall be provide 1 electrician and 2 helper daily for Attending /repairing street light/ Hanger light fittings. (c) Non attending complaints after 8 hrs @ Rs-500.00/day shall be recovered from the contractor. (d) Rate is included for repairing hanger lights and street lights up to 11 Mtr heights.
Taking down LED Solar street light all in one , Cleaning/Washing dust from Solar panel, repairing to cable connection /loose connection, checking to battery & topup to distil water including testing completed all as per specified & directed by Engineer-in-Charge.
M&L for servicing of High mast light driving mechanism by checking all electrical and mechanical component, chain, pulely, rope, motor etc and greasing oiling of chain, motor, pulley etc and servicing of motor, control panel, auxiliary contacts, replacement of u/s items i.e toggle switch, indicator light, control wiring complete all as specified and directed. Note: 1.Cost of material and labour of oiling and greasing, suitable auxillary contacts along with checking of all electrical components must be included in the quoted rate. 2. Cost of spare parts reqd for replacement will be measured and paid separately.
Taking down old unserviceable driver from LED light fitting and S&F LED outdoor driver with all electrical connection as per existing make on site and testing for smooth function complete all asdirected. Make: Cropmton / Bajaj/ Havells
(a) for LED light fitting bollard 9 W
(b) for LED light fitting 15-35 Watt
(c) for LED light fitting 60-72 Watts
(d) for LED light fitting 80 -120 Watts
(e) for LED light fitting 300 Watts
Taking down old unserviceable old light fitting and S&F post top LED light fitting made in die cast aluminium with glare free indirect lighting uniform distribution and IP65 protection 20 Watt with fixing arrengement like. suitable size GI pipe, flanged stand fixed in PCC with nut bolt fastner etc. as directed by Engr-in-charge. Make: Havells/Bajaj/crompton
Taking down old unserviceable existing street light fitting and S&F (in Replacement) energy saving and environmental frindly long life LED light fitting, 35 W 230 V outdoor type with high pressure die cast aluminum housing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics IP 65/IP66 road way luminaries with LEDs as light source and lens embedded PC cover/toughened glass and impact resistance of IK07 and electronic driver fixed on pole with and including suitable dia size bracket as per manufacturer recommendation, bracket 1.5 m long complete with MS flat iron clamps (clamp shall be 40x50 mm MS flat), nuts and bolts and washers painting the clamps with coat of aluminum paint over a coat of red oxide primer including connection complete all as specified. Make: Havells/Bajaj/crompton
All as above item Ser No 6 but 60 W complete all as specified and directed.
All as above item Ser No 6 but 70 W complete all as specified and directed.
Taking down old unserviceable existing flood lights fitting and S&F (in Replacement) energy saving and environmental frindly long life exclusive innovative flood light luminaries 70 W 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant with LEDs as light source and lens embedded PC cover/toughened glass and impact resistance of IK07 and electronic driver fixed on high mast pole or any other place as required on site incl making all necessary arrangement for fixing complete with MS flat iron clamps (clamp shall be 40x50 mm MS flat), nuts and bolts and washers complete all as specified Make-Havells/Crompton/Bajaj
All as above item Ser No 9 but 120 W complete all as specified and directed.
All as above item Ser No 9 but 170/180 W complete all as specified and directed.
All as above item Ser No 9 but 200/210 W complete all as specified and directed.
All as above item Ser No 9 but 300 W complete all as specified and directed.
Taking down old , rusted, unsv Junction box of any size, type and supply & fix new junction box of size not less than 400 mm x 300 mm x 190 mm , made out of fibre material, shockproof and rustprooof, cable entry from bottom, 100% wheather proof, restricted to unauthorised tapping with class FV-0 as per IS : 11731 Part-II or V-0 as per UL-94 and fixing to pole etc using suitable clamps nuts, bolts etc for accommodating and including the following :- (a) Aluminium Bus bar of capacity 100A, -01 Set (b) MCB SP 10 A - 01 Nos
S&F in replacement; 15 mm dia rigid non metallic PVC conduit heavy duty 2mm wall thickness exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock, nuts, saddles, pipe hooks etc complete. Make: Atlas/Finolex/Supreme/ Kalinga/ AKG.
S&F in repair of multi core flexible copper conductor PVC insulated and sheathed cable, 1100 Volts, 1.5 sqmm, 3 core between cable loops box to street light fitting, cable should be tied with the pole using cable ties complete all as specified and directed.
M & L for scrapping of old alum paint of steel tubuar pole 9/11 mtr by mean of emery paper for preparation of smooth surfaces and painting with two coats of alum paint on pole , brackets old junction boxes channels etc incl alternate 30 cm wide white and blue strip painting up to 1.5 mtr height fron ground level incl fixing of red bright laminated reverse lights reflection strip 100 mm wide 3 round complete all as specified and directed by Engr-in-charge.
Trimming for branches of trees, bushes, hurbs under over head line including removal of trees branches etc to a distance not exceeding 50 mtr from over head ine complete all as specified and directed.
Material and labour for rewinding of Highmast motor of 5HP capacity using same size and gauge of copper wire and same number of turns complete with insulation and varnishing and all as directed and specified by Engr-in-Charge
Material and labour for gear oil suitable for gear box of highmast complete all as directed and specified by Engr-in-Charge
Material and labour for repairs to gear box including replacement of worn out driving/ driven gears, bearings, gear keys, gasket oil seals suitable for Highmast consisting of 3 HP motor and refixing it at the same location and all as specified and directed by Engr-in-Charge
Material and labour for repairs to gear box including replacement of worn out driving/ driven gears, bearings, gear keys, gasket oil seals suitable for Highmast consisting of 5 HP motor and refixing it at the same location and all as specified and directed by Engr-in-Charge
S&F in replacement of old unserviceable power contactor 25 Amps, AC3, 3 pole operating voltage 415 V AC Capacity complete all as specified and directed by Engr-in-Charge. Make : Havells/.Bajaj/HPL
S&F in replacement of old unserviceable over load relay of capacity 25 amps complete all as specified and directed by Engr-in-Charge. Make : Havells/Bajaj/Crompton or any other equivalent make of same specification.
S&F in replacement of old unserviceable push button in highmast panel and complete all as specified and directed by Engr-in-Charge
Provn of service for cable fault location for LT UG cable XLPE insulated 1100 volts of any size with fault detector machine complete allas specified and directed
Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable, 1100 volts heavy duty armoured sheathed including excavation in any strata, taking out cable, and making good disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below all as specified and directed. [Make : MS Seal / Raychem / Denson]
(a) 10 sqmm 2 core
(b) 25-50 sqmm 4 core
Taking out of old u/s pole and Supplying and erecting (in true vertical position) steel tubular swaged poles complete with cast iron base plate finial taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat of red oxide primer and two coats of aluminium paint to exposed surfaces and with black bituminous paint for embedded portion of pole all as specified and directed at site.
Taking down old unserviceable rusted street light bracket along with the unserviceable fitting attacheds to the bracket and deposit it to the MES store. Supply and fix of steel tubular pole cap using suitable nut bolts and washer suitable for 6/7/9/11 meter pole complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation etc
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation or as per site requirement etc all as directed by Engr -in-Charge.
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate, including demolition of existing etc
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /culverts or enclosed in GI pipe/ fix complete all as specified , for following size:-
(a) 25 Sqm 4 core
(b) 16 Sqm 4 core
(c) 16 Sqm 2 core
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insuating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin core mltistranded cable flat or circulas 6 sq mm incl taking out old unserviceable wire complete all as specified and direcred by engr -in-charge
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insuating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin core mltistranded cable flat or circulas 10 sq mm incl taking out old unserviceable wire complete all as specified and direcred by engr -in-charge
Supply , laying , jointing of aluminium service wire pvc insulated 10 sqmm 2 core laid in trenches, ducts fix on walls/poles with proper size saddles and clamp and complete all as specified and directed by Engr-in-charge
Taking out the old one and Supply, Install, Test and Commissioning of Feeder pillar box out door type fabricated out of 3 mm thick CRCA sheet double door, of size 500x500x300 mm with neutral link/busbar complete with powder coating with seven tank process mounted on M.S angle Iron frame, duly grouted with PCC reqd. with all electrical connection complete all as directed including following:- (a) S&F MCCB TP 100 Amps 35 KA Ics=100% of Icu , Fixed thermal and fixed magnetic setting -1 Nos ( Haveles Cat part No: IHLFT0100#) (b) S&F Street light Astro mini digital timer, single phase, Base DIN -1 Nos (L&T Cat part No: T2DDT7) (c) S&F contactor 3P, 70 Amps, AC3 Make: L&T, ML-4 -1 Nos Note : THe contractor shall submit layout diagram for approval from GE
S&F in repair of street light timer, astro mini type for lighting control based on sunrise/ sunset timing by lattitude/ longitude settings time switch 110-240 V AC 1 phase , base /DIN as specified and directed. Make: L&T / Havells/ hager
S&F in replacement of old unserviceable power contactor ML-4, 70 Amps, AC3, 3 pole operating voltage 415 V AC Capacity. Make :- L&T Cat Part No. SS 90910/ Siemens / GI.
S&F in replacement of old unserviceable power contactor ML-3, 40 Amps, AC3, 3 Pole, operating voltage 415 V AC Capacity. Make :- L&T Cat Part No. SS 90721 / Siemens / GI.
Taking down of old u/s and S&F MCCB, 3 Pole, 100 Amps, 415 V AC, 25 kA breaking capacity, Ics=50% Icu with spread terminals with all electrical connection complete all as specified and directed.
Taking out the old one and S&F 40 mm light grade GI pipe Bracket for street light (not less than 1.5 mtr long) and two Nos of mild steel clamp & made out of 32 x 3 mm flat iron complete with bolts and nuts and suitable size washers all as specified & directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc.
Soft/loose soil
Hard/dense soil
Soft/disintegrated rock
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. [Note : Measuremenet will be done after punning]
M&L for brick protection covers laid over cables of sub class'B' bricks old size all as specified and directed.
S & F in replacement old unserviceable Round PVC Globe Garden Light with LED Lamp 03 Watts, Lamp Holder Fixing acessories, connecting wires, the fitting shall be suitable for 50/40 mm dia GI pipe all as specified and directed by Engr-in-Charge
M&L for Servicing, cleaning of complete unit (indoor and out door) of air cooled split type AC of any capacity by using blower, cleaning of condenser coil with water, checking all the parts, electrical connection , cleaning the air filters, combing of fins by using fins comb including replacing defective filters, burnt wiring, tightening of electric wiring connections, etc, as directed by Engr-in-charge.
M&L for replacement of existing old U/S insulation of refrigerant pipes of spit air conditioner up to 3 TR cap all as specified and directed.
M&L for replacement of micro processor printed circuit board complete suitable for split type AC's as per exiting make & model up to 3 TR Cap complete all as specified and directed by Engr-in-charge.
M&L for replacement of PCB of indoor/outdoor unit of Inverter type AC as per existing make & model complete all as specified and directed by Engr in Charge
M&L taking out defective micro processor printed circuit board of split type AC of existing Make/Model up to 3 TR Capacity for repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed by Engr-in-charge.
M&L taking out defective micro processor printed circuit board of split of invertor type AC of existing Make/Model up to 3 TR Capacity for repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable starting capacitor suitable of window type/split type AC's up to 3 TR Capacity as per existing cap all as directed.
M&L for replacement of unserviceable running capacitor 30/36/40/45/55+4/55+6 mfd suitable for split/window type AC's 1 to 3 TR cap of existing make & model all as directed.
M&L for replacement of capacitor 4/6 mfd suitable for fan motor of (split/window /water cooler/Desert cooler fan motor)
M&L for replacement of unserviceable swinging motor of indoor unit of split type AC up to 3TR capacity suitable for existing make/model complete all as specified and directed by Engr in charge
M& L for replacement of condenser fan/blower motor with bush and washers as per existing make and model for split type/invertor type AC up to 3 TR Capacity complete all as specified and directed.
M&L for replacement of existing unsv compressor unit with new Compressor unit as per existing make & model including taking out the old u/s burnt out Compressor of split type/Invertor type Air Conditioner, unsv replacement of bushes, sleeves, washers nut and bolt, relay terminal cover, clips reqd for fixing of new compressor, cutting, brazing of copper piping, charging of suitable refrigerant gas as required Qty to obtained desired cooling, carry out leak test etc., all as required at site complete for following capacity:- Make: Emerson/Carrier/ Tecumsha/ LG/Voltas
Capacity 1.5 TR
Capacity 2.0 TR
Capacity 3.0 TR
M&L for replacement of unserviceable fan blade of condenser unit of split type AC up to 3 TR as per existing make and model complete all as directed by Engr-in-charge.
M&L for leak detection by nitrogen pressure test in refrigerant system of AC, cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas as required quantity to achieve desire cooling complete all as specified an directed-
Split type AC 1.5 TR capacity
Split type AC 2.0 TR Capacity
Split type AC 3.0 TR capacity
M&L for replacement of unsv contactor kit of split type AC as per existing make & model up to 3 TR complete all as specified and directed.
ML for replacement of unsv copper tubing 5/8" dia
M&L for replacement of unsv copper tubing 3/8" dia
ML for replacement of unsv copper tubing 1/2" dia
M&L for replacement of unsv copper tubing 1/4" dia
M&L for replacement of unsv power cable cord PVC flexible copper wire 2.5 sqmm 3 core
Labour only for rectification of water leakage problem by cleaning indoor unit & drain pipe of split type AC up to 3 Ton cap complete all as specified and directed
M&L for replacement of unsv valve of split type AC up to 3 TR cap
M& L for replacement of unserviceable hermetically sealed/rotary compressor with new Compressor suitable for window type AC of following capacity, including replacement of unserviceable bushes, sleeves, washers nut and bolt ,foundation legs including relay terminal cover and clips and including cutting, brazing, leak detection, charging of suitable refrigerant gas as required to obtained desired cooling, carry out leak test etc., all as required at site complete commissioning, testing for the following capacity Make-Emerson/Carrier/ Tecumsha/ LG/Voltas
Compressor suitable for 1.5 TR Capacity
Compressor suitable for 2.0 TR capacity
M&L for replacement of unserviceable electric blower motor suitable for 1/1.5 /2TR capacity window type AC double speed, single phase 230 volt 50 Hz, all as directed Make - Gulmarg/AUE or as per existing make/ type.
M&L for replacement of unserviceable thermostat switch suitable for water coolers, Window type AC's /split AC's, refrigerators and Deep freezers any capacity, make & model all as directed.
M&L for replacement of starting relay suitable for water coolers, Window type AC's /split AC's, refrigerators and Deep freezers any capacity, make & model all as directed
M&L for replacement of existing unsv fan motor of desert coolers up to 6000CFM as per existing model & speed including taking out the old /unserviceable motor all as specified & directed.
M&L for replacement unservicable water pump of desert cooler with submersible type water pump 0.6 KW, 1.25 m head pump complete all as specified and directed.
M&L for replacement of Khas pad (set of three) with best quality new pad, for desert coolers of 4000/5000 cfm capacity.
M&L for replacement of fan speed control switch of Desert cooler up to 6000 CFM PVC body unit as per existing make & model complete all as specified
M&L for replacement of Lover control knob switch of Desert cooler up to 6000 CFM PVC body unit as per existing make & model complete all as specified
M&L for replacement of unsv fan blade of desert cooler up to 6000CFM as per existing type make & model complete all as specified and directed.
M&L for replacement of honeycomb pads of desert cooler up to 6000CFM as per existing size complete all as reqd at site
M&L for replacement of desert cooler body 66x660x900 mm with front grill and three side lover fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size 660x660x200 mm deep fabricated out of 20 gauge milled steel plan black sheet including taking out and reinstallation complete with standard fitting such as pvc pipe for water electric motor and fan motor clamp for motor, switch fan speed regulator including fixing and conncting existing cooler fan electric pump with core pvc insulated & pvc sheathed cable (min 3 mtr in length External surface shall be spray painted with approved paint over a coat of red oxide primer and internall surface of body cooler pump and motor shall be paint with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed by Engr -in Charge.
M&L in replacement of 01 Nos front grill and 3 side lovvers suitable for desert cooler duly spray painted with approved paint over a coat of red oxide primer and internal surfac of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer as required on site co
M&L for servicing of water cooler of installed capacity 40/40 to 150/150 Ltrs, cleaning the tank, condenser coil, oiling the fan motor, checking all parts, repair to electrical burnt/loose connection, replacement of rubber gasket, washer minor u/s parts etc. all as specified and directed.
Supply and fix hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for water coolers of following capacities including provn of bushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity:- Emerson/Carrier/ Tecumsha/ LG/Voltas
Cooling capacity 40 Ltrs/Hr
Cooling capacity 60 Ltrs/Hr
Cooling capacity 150 Ltrs/Hr
M&L for replacment of freezer of refrigerator as per existing make model including cutting, brazing complete all as specified & directed by Engr in Charge of cap 192 to 385 Ltr
M&L for leak detection in refrigerant system of Refrigerator (165 to 300 Ltrs cap) including cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas as required quantity complete all as specified and directed-
Taking out existing split type air conditioners of any type and capacity removing from the site and keeping it in a safe custody for re-use or deposit in store all as specified and directed.
Fixing only split type air conditioners of any type and capacity including core cutting for passing copper tubing , drain pipe & cable through stone masonry wall with connected accessories such as bracket, copper tubing, cable from indoor to out door unit and rain water pipe etc as per site requirement all as specified and directed.
M&L for replacement of old unsv outdoor unit of split type with AC 3 star rating, 1.5 TR Cap having copper tubing, high EER rating compressor (for gas R-407/410/32), blower motor etc. complete including, making elect, refrigerant piping connection, brazing, leak testing and charging suitable refrigerant gas to achieve desired cooling effect and testing complete all as specified and directed Make- Blue Star/Voltas/Hitchin/Daiken
M&L for replacement of Unsv indoor unit of split type AC 1.5 TR complete having 3 star rating suitable for (R-407/410/32) gas Make- Voltas/Blue Star/Hitachi/Daiken
M&L for replacement of unsv MCB SP C series 20 A to 32 A m breaking cap 6kA Make - L&T/Legrand/Hager/Siemens
M&L for replacement of Metal plug 20A, 2Pin+SC Make L&T/Legrand/Hager/Siemens
M&L for replacement of Metal socket 20A, 2 pin+SC Make L&T/Legrand/Hager/Siemens
M&L for replacement of Unsv sheet metal enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole C series MCB 20 Amps, 240 volts all as specified and directed. Make: L&T/Legrand/Hager/Havel's
M/L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & capping all as directed and specified . ( Note :Two runs of 4.0 Sqmm copper cable, one run of earth wire of 4.0 Sqmm copper cable shall be measured & paid as one length).
M&L for servicing, rewinding of stabilizer 4 KVA with copper winding as per existing gauge & turns including replacement of defective items compete all as specified and directed
M&L for replacement of unsv stabilizer 5 KVA with copper winding incding taking out unsv stablizer complete all as specified and directed
M&L for replacement of unsv condenser cooling coils of Split type AC up to 3 TR cap with new copper coil including taking out unsv condenser coil complete all as reqd at site and specified by Engr in Charge
M&L for replacement of unsv drain flexible PVC pipe of split type AC complete all as specified and directed by Engr in Charge
M&L for replacment of unsv rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) two layer ISI marked hoisted and fixed in position all as specified in SSR Pt-I of capacity 1000 Ltrs complete all as specified & directed
M&L for replacment of condensor coil blower motor of water cooler 40 to 150 Ltr /refrgerator 190 to 385 Ltr capacity as per existing type & model complete all as specified & directed by Engr in Charge
M & L Attending emergent complaints i.e Air conditioners any type, water cooler any type, Refrigerator any type including carrying out minor repairs including replacing necessary capacitors, thermostat,relays, PCB etc as required to make the system in order/ functional complete all as specified and directed. Note :- Rate of spare parts shall be measured and paid separately under relevant items. Minor parts deemed to include in cost of item.
M & L Horizontal direction drilling (HDD) including pilot drilling, preraming,reaming suitable for 100mm dia HDPE pipe using trencheless technology & including HDPE pipe of 100mm dia of pressure not less than 10kg/Sqcm PE-63 grade, pulling of HDPE pipe under the runway/taxi link at a level not less than 2.5mtr below top surface of existing runway/taxilink at tech area, including necessary passing GI wire for pulling cable and directed.
K K ENGINEERING SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .