| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹40.4 L+₹5.2 L (14.8%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹40.9 L+₹5.7 L (16.1%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹41.3 L+₹6.2 L (17.5%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹42.4 L+₹7.2 L (20.4%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND EAST BANGALORE
GE I RD East Bangalore 93
PROVISION OF CERTAIN EM MINOR WORKS IN ADE AND GTRE UNDER GE I RD EAST BANGALORE
2021_MES_495422_1
8198
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I R AND EAST BANGALORE
D b (i)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND EAST BANGALORE
₹80,000
Yes
17 Mar 2022
17 Dec 2021
10 Jan 2022
17 Dec 2021
7 Jan 2022
1 Jan 2022
18 Dec 2021 - 27 Dec 2021
60 days
Amount
Taking down carefully aluminium point wiring (light,fan,socket or power) complete with fittings such as switches, sockets, ceiling rose and making good the disturbed surfaces of wall/ceiling etc complete all as specified and as directed
M&L Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including rigid Steel concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I, ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
One light/fan point controlled by one switch
One 5 Amp socket on same board
One 5 Amps Socket point on independent board for wall mounting times
All as per ser item No 02 above but using 4 sqmm PVC insulated unsheathed, multistranded copper conductor cable with 4 sqmm continuous earth conductor for one 3 pin 15 amps socket outlet on an independent board complete all as specified and as directed
Supply and fixing of switch modular 1 way 6 amps, 1 module with frame and cover 230 volts complete all as specified and as directed
Supply and fix socket , 6A 2/3 pn Combined 2 module complete all as specified and as directed
Supply & fix ceiling rose surface backlite three terminal complete all as directed
Supply and fixing of switch modular 1 way 16 amps, 1 module with frame and cover 230 volts complete all as specified
Supply and fixing of socket modular 6 Amps 2/3 pin combined 2 module with frame and cover 230 volts grade complete all as specified
Supply and fix modular fan step regulator ,120W-2 module complete all as specified and as directed
M & L for taking down existing ceiling fan any sweep from the ceiling and kept in safe custody and making good the disturbed surfaces of ceiling etc complete all as specified and as directed ( NOTE : Removing old celing fan and deposit to EM stores)
M&L for refixing celing fan any sweep on ceiling after reparing/servicing and replacement of bush,braring, rubberbush,nuts,boilts and washere, and small spares including synthetic enamel paint painting as required and making celing fan serviceable including three core flecible wire from ceiling rose to fan all as specified and as directed Note : celing fan dismantled against item No 13
Supply and fix LED luminaires square type 2x2 35/36W with Environmental friendly new generation aestheticall designed ,ultra modern recess mounting iuminaire with high brightness SMD LEDs as light sourse sutible for armstong/gypsum or similar ceiling mounting system including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed by Engr-in-charge.
Supply & fixing only LED batten with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & intregrated electronic driver 1 x 20 watts fixing on wall/ celing complete all as specified as directed.
M&L for submain wiring with 2 runs of 4.0 sqmm single core PVC insulated stranded copper conductor cable drawn through suitable rigid non metallic PVC conduit with one run of 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections all as directed. (AC POINT) Note : 2 runs of 4 sqmm PVC insulated unsheathed copper conductor and 1 run of 4.0 sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run
Supply and fixing Distribution board Power line Vertical TPN MCCB DBs with IP 54 Protection metal door 415 volts, 8 way with double door fixed on flush to the wall including making the hole in th wall and fixing the DB including cement work and plastering complete including comprising the following all as specified and as directed (a) MCCB with thermal magnetic release 415 volts 3 pole 100 Amps capacity and breaking capacity 25 KA - 01 No Make of MCCB :INDOASIAN /ABB/L&T/Legrand (b) MCBs 10 KA breaking capacity SP 230 volts 6 to 32 Amps - 32 Nos Make of MCBs :INDOASIAN /ABB/L&T/Legrand . .
S&F SPN MCBs distribution board of sheet metal enclosure factory made double door powder coated single pole and neutral with 200 amps rated bus bar 4 way 240 Volts complete all as specified and as directed
S& F MCB SPN 32 Amps 10 KA capacity 240 Volts complete all as specified and as directed Make :- Indo Asian C&S /CG/Legrand
S& F MCB single pole 6 to 32 Amps 10 KA capacity 240 Volts complete all as specified and as directed Make :- Indo Asian C&S /CG/Legrand
Earthing complete with 600x600x6.00MM thick GI earth plate electrode buried directly in ground not less than 2.25 mtr below GL with the top edge of the plate at a depth not less than 1.5 mtr from GL, connected to GI earth lead of 4.0 mm dia by means of nuts, bolts, washers, checknuts etc, made out of galvanised iron or steel, earth wire protected by galvanised iron pipe, connected to main switch board complete including necessary earth work,excavation,PCC chamber, watering pipe, funnel, wire mesh, RCC chamber cover etc all as specified and directed in EP No:3 of SSR Part-I
M & L for chemical earthing complete with copper earth plate electrode 90cm x 60cm x 5mm thick buried directly in ground (earth pit not less than 3 mtr deep below ground level) with top edge of the plate not less than 2.10 mtr below normal ground level, connected to and including copper earth strip of 32x6 mm by means of rivetting and brazing and protected by GI pipe light grade of suitable size up to the test point i.e. up to 7.5 mtr, including providing alternate layers up to full volume of pit by charcoal dust and common salt, magnesium sulphate & vegetable soil all around the plate 15 cm depth and width minimum including PCC pit chamber, watering pipe of 50mm dia medium grade GI pipe up to the top of the plate having funnel complete and RCC cover, connecting to the test point and testing on ground complete and including excavation and earth work in any type of strata and cleaning of site all as specified in MES SSR Part-I and directed by Engineer-in-Charge.
M & L for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 3 mtr deep below ground level) with top edge of the plate not less than 2.10 mtr below normal ground level, connected to and including copper earth strip of 20 x3 mm by means of rivetting and brazing and protected by GI pipe light grade of suitable size up to the test point i.e. up to 7.5 mtr, including providing alternate layers up to full volume of pit by charcoal dust and common salt, magnesium sulphate & vegetable soil all around the plate 15 cm depth and width minimum including PCC pit chamber, watering pipe of 50mm dia medium grade GI pipe up to the top of the plate having funnel complete and RCC cover, connecting to the test point and testing on ground complete and including excavation and earth work in any type of strata and cleaning of site all as specified in MES SSR Part-I and directed by Engineer-in-Charge.
Supply and fixing copper earthing strip of size 20 x 3.15 mm for connection from earth test point to equipment with help of complete brazing etc complete all as specified and as directed
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louver complete all as specified and as directed
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, heavy duty and frame and louver complete all as specified and as directed
M & L for making hole for fixing of exhaust fan of size 300/4500 mm in the existing stone masonary wall complete with plastering and removing the pcc obtain from the making of hole all as specified and directed including matching with surrounding as per existing complete all as specified and as directed
Supply and fix Extra Efficient (120 Lm/W) next Gen Highbay with Elliptical design, modular lens Optics for optimized Lighting distribution to improve 20% operational efficiency, with EMC/ EMI Complient Potted Driver & easy maintenance, Flicker free Illumination for Industrial Space all as specified and directed.
M&L for submain wiring with 2 runs of 2.5sqmm single core PVC insulated stranded copper conductor cable drawn through suitable rigid non metallic PVC conduit with one run of1.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections all as directed. Note : 2 runs of 2.5 sqmm PVC insulated unsheathed copper conductor and 1 run of 2.5sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run (FOR HIGHBAY LIGHT /AIR CIRCULATOR /BUILDING SECURTIY LIGHT)
S&F SPN MCBs distribution board of sheet metal enclosure factory made double door powder coated single pole and neutral with 200 amps rated bus bar 4 way 240 Volts
S& F MCB SPN 32 Amps 10 KA capacity 240 Volts complete all as specified and as directed
S& F MCB single pole 6 to 32 Amps 10 KA capacity 240 Volts complete all as specified and as directed
S & F wall mounted fan 400mm sweep elegently desined fan base /120 ribs guard full card contral for speed and ocillation ON/OFF and aero dynamically designed and balanced blades and power in put 50 watts 230 volts supply 1350 RPM necessary connection with 3 core flexible wire from wall mounted fan to ceiling rose complete all as specified and as directed. Bajaj Model No 250552 Esteem
Supply and fixing copper earthing strip of size 20 x 3.15 mm for connection from earth test point to equipment with help of complete brazing etc complete all as specified and as directed
Supply and fix Exhaust fan 225mm sweep, metal body, air delivery 500 cmm complete all as specified and directed by Engr-in-charge.
Supply and fix industrial Exhaust fan 450mm sweep , metal body,air delivery 1900 cmm complete all as specified and directed by Engr-in-charge.
Supply and fixing new MCCB in existing panel of capacity triple pole 63 Amps, 415 Volts, 16 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing new MCCB in existing panel of capacity Four pole 63 Amps, 415 Volts, 16 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing new MCCB in existing panel of capacity triple pole 100 Amps, 415 Volts, 16 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing new MCCB in existing panel of capacity Four pole 100 Amps, 415 Volts, 16 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing new MCCB in existing panel of capacity triple pole 200 Amps, 415 Volts, 36 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing new MCCB in existing panel of capacity Four pole 200 Amps, 415 Volts, 36 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing new MCCB in existing panel of capacity triple pole 250 Amps, 415 Volts, 36 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing new MCCB in existing panel of capacity Four pole 250 Amps, 415 Volts, 36 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing new MCCB in existing panel of capacity triple pole 400 Amps, 415 Volts, 50 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing new MCCB in existing panel of capacity Four pole 400 Amps, 415 Volts, 50 KA complete all as specifiedand and directed. Make L&T/Standard/Legrand
Supply and fixing of socket modular 6 Amps 2/3 pin combined 2 module with frame and cover 230 volts grade complete all as specified
Supply and fixing LED light fitting 2 X 20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable sizecomplete all as specified
Supply, installation, testing and commissioning factory made Indoor cubical type LT Pannel board dust and vermin proof, free standing, floor mounting type mounted on and including 1:3:6 PCC foundation as required at site and of fabricated by 3.0 mm thick MS sheet 50x50 X 5 mm angle iron of required type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with 2 cots of synthatic anamel paint complete and having separate doors/compartments inside for accomaditing all incomming/out going feeders wtih suitable size of glands/lugs, including removing old panel to credit & fixing new panel in same position with existing cable all as specified and directed by Engr - in - charge. Panel should be CPRI approved (a) Moulded Case Circuite Breaker 4 pole 25 KA breaking capacity 125Amp (Incomimg) - 01 Nos (b) Moulded Case Circuite Breaker 3 pole 16KA breaking capacity 63 Amp (Out Going)-04 Nos (c )FASD starter 20 HP-03 nos (f) Three phase volt meter 1 No (g) Three phase Ameter 1 No (h) LED Indicater lamp Red, Yellow,Blue- 01 set (j) Complete internal wiring with suitable cpper conductor wires-1 Lot (k) Provision of etra space for One more outgoing feeders Suitable for 63 Amps MCCB
ESSAR DIESEL SERVICE
SAI CONSTRUCTIONS
GURU ENTERPRISES
MAJ CONSTRUCTIONS
Vishwas Enterprises
Siddivinayaka Constructions
RASHMI BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .