| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹38.6 L+₹5.7 L (17.5%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹46.9 L+₹14.1 L (43.0%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹53.7 L+₹20.9 L (63.7%)Rejected-Finance 365 B 10 HENRY COMPLEX MATHIYAS NAGAR KP ROAD NAGERCOIL KANNIYAKUMARI DISTRICT 629001 | KANNIYAKUMARI | TAMIL NADU | 629001 | L4 | Rejected-Finance Not being lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in required category |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
24 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR / REPLACEMENT OF LT DISTRIBUTION SYSTEM AT OTM ACCN AREA UNDER GE MINNIEBAY, PORT BLAIR
2021_MES_466032_2
8967/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹60,000
Yes
2 Nov 2021
1 Sept 2021
2 Oct 2021
1 Sept 2021
24 Sept 2021
11 Sept 2021
1 Sept 2021 - 10 Sept 2021
60 days
Amount
M&L for preparation of internal and external surface of LT Feeder Pillar Box / Panel Boards of various size, complete removal of existing treatment by scraping or by chemicals and applying one coat of synthetic enamel paint with help of spray gun complete all as specified and as directed
M& L for repair of LT Feeder Pillar Box / Panel Boards made out of 2.00 mm thick mild steel sheet fixed to existing frame and painted with two coats of synthetic enamel paint with help of spray gun over a coat of red oxide primer, fixing to existing frame complete all as specified and directed.
S&F stainless steel tower bolts, 300mm long bright bolt including connected accessories fixed on doors for locking arrangement of LT Feeder Pillar boxes complete all as specified and as directed
M&L for repairs of door hinges of LT feeder pillar / Panel box of any type with welding complete all as specified and as directed
Demolition of PCC as situated in any position complete all as specified and as directed
M&L for cement concrete 1:2:4, type B1 using 20mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed
M&L for cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in couping / collar of poles including necessary form works complete all as specified and as directed
Taking down MCCB of any size complete all as specified and as directed
S&F of MCCB 630 Amps, Triple pole, 415 volt, breaking capacity 36 KA conforming to IS 13647 - II complete all as specified and as directed by Note : MCCB should be ICU = 100 % ICS 3, MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F of MCCB 400 Amps, TPN/4 pole, 415 volt, breaking capacity 36 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F MCCB 400 Amps,Triple pole, 415 volt, breaking capacity 36 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3, MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F of MCCB 250Amps,TPN/ 4 pole, 415 volt, breaking capacity 25 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3, MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F of MCCB 250Amps,TP/ 3 pole, 415 volt, breaking capacity 25 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3, MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F of MCCB 200Amps,TPN/ 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3, MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F of MCCB 160 Amps, TPN/ 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F of MCCB 100 Amps, TPN/ 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3, MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F of MCCB 63 Amps, TPN/ 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3, MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F of MCCB 25 Amps, TPN/ 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3, MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
Taking down Change Over Switch of any size complete all as specified and as directed
S & F of on load change over switch 4 pole 400 Amps in sheet metal enclosure complete all as specified and as directed
Taking down / up old aluminium cable Lugs of any size complete all as specified and as directed
S&F of aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed for the following sizes of cables :-
Taking down of old copper cable lugs of any size complete all as specified and as directed.
S&F of copper cable lugs for fixing of armoured cables in panels complete all as specified and as directed for the following sizes of cables complete all as specified and as directed:-
Taking down old un serviceable cable gland of any size complete all as specified and as directed
S&F of cable gland for following size of LT UG cables in panels complete all as specified and as directed
Taking down old rusted panel board complete all as specified and as directed
Supply, installation, testing and commissioning indoor type LT panel board double door of suitable size for 3 phase 415 Volts of suitable size bus bar of rating 1800 Amps made out of 2.00 mm thick CRCA sheet with powder coated along with iron frame of size 50x50x6mm cubical type CPRI approved of factory made including stand and PCC foundation as per site requirement complete all as specified and as directed and to include the following:- INCOMING (a) ACB 4 Pole EDO with LSIG and Reverse Power Protection, with display mechanically and electrical inter locked of both the ACB, shunt trip and UVR protection of 1250 Amp 50 KA - 02 Nos. (b) Digital Ammeter with CT's (1250/5 Amps) - 02 Nos. (c) Digital Volt meter 0-500 Volt - 01 No (d) R-Y-B indicating lamp - 03 Nos. OUTGOING (a) MCCB 4 pole 400 Amp 36 KA - 01 No. (b) MCCB 4 Pole Arrangement - 02 Nos. (c) Digital Ammeter with CT's (400/5 Amps) - 02 Nos. (d) R-Y-B LED Indicator - 06 Nos (e) MCCB 4 pole 630 Amps 50 KA - 01 No. (f) Digital ammeter with CT's (630/5 Amps)
Supply, installation, testing and commissioning LT panel board double door of suitable size for 3 phase 415 Volts of suitable size bus bar of rating 800 Amps out door made out of 3.15mm thick CRCA sheet for out side of the panel board and 2.0mm thick CRCA sheet for inside with powder coated along with iron frame of size 50x50x6mm cubical type CPRI approved of factory made including 300 mm panel stand made out of angle iron size 50 X50X 6mm of complete including PCC foundation as per site requirement complete all as specified and as directed and to include the following- INCOMING (a) MCCB 4 pole 200 Amp 25 KA - 01 No (b) Digital Ammeter with CT's (0-400) - 01 No (c) Digital Volt meter 0-500 Volt - 01 No (d) LED indicating lamp (R-Y-B) - 03 Nos OUTGOING (a) MCCB 4 pole 160 Amp 16 KA - 01 No. (b) MCCB 4 Pole 100 Amp 16 KA - 01 No. (c) MCCB 4 Pole 63 Amp 16 KA - 01 No. (d) Digital Ammeter with CT's (0-400) - 01 No
S&F in repairs digital Ammeter 0 - 650 Amps rating including necessary fabrication required and painting the affected area to match with existing pattern complete all as specified and as directed
S&F in repairs digital Voltmeter 0-750 Volts rating including necessary fabrication required and painting the affected area to match with existing pattern complete all as specified and as directed
Taking down unserviceable old UG cable and DWC HDPE pipes of any size and any type complete all as specified and directed. Note : The serviceable cable, DWC pipe, lugs, glands, coupler of bends shall be reused after proper cleaning
Supply and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, PVC insulated, PVC sheathed, galvanized steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified a for the following size :- Note : The rates shall be inclusive of cable lugs, cable glands and joint kit (if required).
4 Core 6 Sqmm
2 Core 10 Sqmm
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 Core 120 Sqmm
3.5 Core 400 Sqmm
1.0 Core 400 Sqmm
Relaying of serviceable cable obtained from taking down, laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 10 Sqmm to 35 Sqmm complete all as specified and as directed
All as per item No. 35.00 above but of size 50 Sqmm to 95 Sqmm complete all as specified and as directed
All as per item No. 35.00 above but of size 120 Sqmm to 240 Sqmm complete all as specified and as directed
All as per item No. 36.00 above but of size 300 Sqmm to 400 Sqmm complete all as specified and as directed
Supply & Laying in replacement DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed
Supply & Laying in replacement DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed
Supply & Laying in replacement DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 77 mm and inner dia 63 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed
Supply & Laying in replacement DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 180 mm and inner dia 152 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed
Relaying of DWC (Double Wall corrugated) HDPE pipe of outer dia of 40 mm and inner dia 32 mm polyethylene including coupler & Bend including taking down complete all as specified and as directed
Relaying of DWC (Double Wall corrugated) HDPE pipe of outer dia of 63 mm and inner dia 50 mm polyethylene including coupler & Bend including taking up/down complete all as specified and as directed
Relaying of DWC (Double Wall corrugated) HDPE pipe of outer dia of 77 mm and inner dia 63 mm polyethylene including coupler & Bend including taking up/down complete all as specified and as directed
Relaying of DWC (Double Wall corrugated) HDPE pipe of outer dia of 180 mm and inner dia 152 mm polyethylene including coupler & Bend including taking down complete all as specified and as directed
Taking down of old GI Pipe of any dia complete all as specified and as directed
S&F of 40mm GI pipe of light grade with fitting and fixture for fixing on wall and road crossing etc. complete all as specified and as directed
S&F of 50mm GI pipe of light grade with fitting and fixture for fixing on wall and road crossing etc. complete all as specified and as directed
S&F of 63mm GI pipe of light grade with fitting and fixture for fixing on wall and road crossing etc. complete all as specified and as directed
S&F of 80mm GI pipe of light grade with fitting and fixture for fixing on wall and road crossing etc. complete all as specified and as directed
Excavation in trenches any type of soil (soft/loose /hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed
Returning filling in using excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 cm all as specified and as directed
Removing surplus excavated soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed
M&L for road cutting of depth 150mm, removing of material , returning filling and PCC 1:2:4 for laying of LT UG cable all as specified and as directed
M&L for fault finding of LT UG Cable including excavation , returning refilling after rectification of fault with fixing of Straight through joint kit, extra UG Cable and DWC (Double Wall corrugated) HDPE pipe complete all as specified and as directed by Engineer-in -charge. Note:- LT UG Cable, Straight through joint kit and DWC (Double Wall corrugated) HDPE pipe shall be measured and paid separately under relevant item of this Schedule
Taking down of old u/s cable Joint Kit complete all as specified and as directed
S & F of cable jointing kit for 1100 Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 50 Sqmm 3.5 core complete all as specified and as directed
S & F of cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm 3.5 core as in repairs complete all as specified and as directed
S & F of cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 150 to 240 Sqmm 3.5 core as in repairs complete all as specified and as directed
S & F of cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size300 to 400 Sqmm 3.5 Core as in repairs complete all as specified and as directed.
M&L for re-routing the serviceable power cable on wall /cable duct of size 16 to 50 Sqmm with shaddling with aluminium pati of required size of screw inside cable duct complete all as specified and as directed
M&L for re-routing the serviceable power cable on wall /cable duct of size 70 to 185 Sqmm with shaddling with aluminium pati of required size of screw inside cable duct complete all as specified and as directed
Taking Down of old u/s Junction box of any type and any size complete all as specified and as directed
S&F for IP 66/ 67 thermoplastic polycarbonate cable junction box of size 155X210X92 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of two nos of GI clamp of size 25X3 mm and one no of MCB SP 6 Amp complete all as specified and as directed
Taking Down of old u/s earthing complete all as specified and as directed
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanized steel plate electrode required, as specified and as directed.
S&F in repairs PCC cable route indicator of size 600X150X 300MM including writing of " MES LT / HT Cable" in white ink over red colored with danger notice fixing above UG Cable 200mm below ground level including PCC and earth work complete all as specified and as directed
M&L for replacement of earth pit indicator for existing earthing pit made out of 16 mm dia and 60 cm long MS Square Bar embedded in PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 30X30X 3 mm thick fixed on side of earth pit cover complete painting and writing over the plate ie. Type , Result, Date of measurement and pit number with black back ground with white paint and complete all as specified
M&L in repair PCC earthing pit of outer size 450X450 X300mm and inner size 430x430x100mm and RCC pit cover of size 450x450x100mm including necessary earth work complete all as specified and as directed
M&L for Painting to Steel tubular / RCC poles 9 m long with one coat of Synthetic enamel paint black/yellow combination Zebra marking up to 1 m from ground level / coping and remaining Job portion painting with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc.complete all as specified and as directed
Dismantling carefully and taking down existing street light fitting of any type from the street light poles of any height along with GI bracket ,clamps, bolts,& nuts etc complete all as specified and as directed
Dismantling the existing old rusted /unserviceable Steel / RCC poles of any type including all fitting fixture complete all as specified and as directed
M&L for GI swaged poles complete with GI base plate finial taper plug, bolts, nuts and screws, with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9M including necessary Earth work,PCC foundation copping etc and refixing of all existing fitting fixture exist in old electric pole complete all as specified and as directed
Supply and laying in replacement 2.5 Sqmm (nominal area) PVC unsheathed multi standard copper conductor PVC insulated 1100 volt FRLSH grade three core cable drawn through PVC pipe of 20mm medium grade along with GI clamp of GI strip size 25x4mm which one side fixing on pole and another side fixing on pipe with GI nuts & bolts for connecting the street light fittings complete all as specified and as directed
S&F in replacement GI bracket for street lights made out of light grade GI pipe 40mm dia, 1.5 mtr long bend to shape as directed, fixed on poles with two Nos GI clamp of size 40 x 6mm flat iron suitable for steel tubular pole including suitable GI nuts and bolts washers complete all as specified
S&F of energy efficient street light luminaire LED type 90watts, IP66 ,230volts, 50 Hz , in Deep drawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts, and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed
S&F of energy efficient street light luminaire LED type 40 watts, IP66 ,230volts, 50 Hz , in Deep drawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts,and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed
Taking out old unserviceable Service wire and supply and fixing Service wire Al Conductor Weather Proof 6 Sqmm 2 core complete all as specified and as directed
Taking out old unserviceable Service wire and Supply and Fixing Service wire Al Conductor Weather Proof 10 Sqmm 2core complete all as specified and as directed
Supply only rubber insulation tape 25 cm width 2.5 Mtr long fixing of connection make water proof outside the electrical equipments and also fixing the underground cable where crack arises outside complete all as specified and as directed
Taking down of light fitting of any size /any type complete all as specified and as directed
S&F of LED Bollard light 10W pressure die cast powder coated with PC diffuser efficient high out put with IP 65 protection including necessary fittings /conections complete all as specified and as directed
Demolition of brick work built in cement mortar complete all as specified and as directed
M&L for brick work with sub ash bricks, straight on plan exc 6m mean radius built in CM 1:6. cement mortar complete all as specified and as directed
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surface and even smooth (without using extra cement) complete all as specified and as directed
Supply and laying broken stone or Boulders filling of Gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 150mm thick, watered and rammed to a true Surface, complete all as specified and as directed
Dismantling old U/S fencing wire mesh, any type complete all as specified and as directed
S&F of chain link fencing 50X50mm mesh or Cages with 3.15mm dia Mild Steel Galvanized Wire with PVC coated , lapped, Straining and Binding with including Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provision of binding wire complete all as directed
Dismantling / Taking down of Cross arms of steel channels or angle section complete all as specified
M&L for cross arms, bracing, supports, clamps and back plate fabricated from structural MS section for gate including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of complete all as specified and as directed
Dismantling / Taking down of old rusted danger notice board complete all as specified and as directed
M & L for PVC Danger notice plate of size 25x20x1.6mm for LT / HT made out of vitreous enameled white, with letters, figures (English, Hindhi,Tamil) and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts complete all as specified and as directed
Material and labour for earthing with GI earth plate electrode 600x600x6.00 mm buried directly in ground vertically to the depth of non less than 2.25 mtr below ground level connected to GI strip 25x3 mm for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete all as specified and as directed NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed in Station. (ii) If the desired earth resistance is not achieve during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible.
Taking down of unserviceable GI earthing strip of any size complete all as specified and as directed
S&F of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, GI strip using porcelain clit / post insulators, complete all as specified and as directed
S&F of GI earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6mm thick, Galvanized using porcelain clit/post insulators, complete all as specified and as directed
Supply and fixing in repair for Alluminium earth continuity conductor or main earthing lead fixed to wall above 11 mtr or rooftop of 3 rd floor or recess or any other indicated situation for loop earthing etc. as required for 25 mm x 3mm thick, alluminium using porcelain clit/post insulators, complete all as specified and as directed
Taking down and refixing after repairs for Alluminium earth continuity conductor or main earthing lead fixed to wall above 11 mtr or roof top of 3 rd floor or recess or any other indicated situation for loop earthing etc. as required for 25 mm x 3mm thick, alluminium using porcelain clit/post insulators, complete all as specified and as directed
Welding of two MS/GI Sheet / Pipes on site including grinding the welded portion and made smooth surface complete all as specified and as directed
SHUSHANT ASSOCIATES
SRI HARSHITA ELECTRICALS
M/s Power Engineering Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .