| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.2 CrAccepted-AOC POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹4.2 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹4.3 CrRejected-Finance | ₹4.3 Cr | 2 | Rejected-Finance other than lowest |
| 3 | 3₹4.6 CrRejected-Finance C O AMBU HOTEL NEAR GOVT POLYTECHNIC DOLLY GUNJ PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹4.6 Cr | 3 | Rejected-Finance other than lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not enlisted in eligible class |
| Sl No | Description | Qty | Unit | BHARAT MULTITECH INDUSTRIES PVT LTD L1 | P NAIDU L2 | City Constructie Pvt Ltd L3 |
|---|---|---|---|---|---|---|
| 1.00GENERAL SUMMARY NOTE: Schedule ‘A’ Part - I to XIII are prepriced by MES under Ser No. 02 to 14. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | ||||||
| 2.00 | Lumpsum price worked out by the tenderer for "BUILDINGS/STRUCTURES" as listed in Schedule ‘A’ Part- I, complete all as specied and directed. | 1 | Lumpsum | 2,51,65,140 ₹2.5 Cr | 2,30,50,000 ₹2.3 Cr | 2,50,00,000 ₹2.5 Cr |
| 3.00 | Lumpsum price worked out by the tenderer for "EXCAVATION & EARTHWORK " as listed in Schedule ‘A’ Part- II , complete all as specied and directed. | 1 | Lumpsum | 7,76,800 ₹7.8 L | 4,90,000 ₹4.9 L | 4,00,000 ₹4 L |
| 4.00 | Lumpsum price worked out by the tenderer for "INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part- III, complete all as specied and directed. | 1 | Lumpsum | 52,614.8 ₹52,614.80 | 45,000 ₹45,000 | 51,000 ₹51,000 |
| 5.00 | Lumpsum price worked out by the tenderer for "INTERNAL ELECTRICFICATION " as listed in Schedule ‘A’ Part- IV, complete all as specied and directed. | 1 | Lumpsum | 9,65,895 ₹9.7 L | 10,00,000 ₹10 L | 8,50,000 ₹8.5 L |
| 6.00 | Lumpsum price worked out by the tenderer for "ROAD /PATH/ CULVERT " as listed in Schedule ‘A’ Part- V, complete all as specied and directed. | 1 | Lumpsum | 16,83,920 ₹16.8 L | 17,00,000 ₹17 L | 17,00,000 ₹17 L |
| 7.00 | Lumpsum price worked out by the tenderer for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part- VI, complete all as specied and directed. | 1 | Lumpsum | 69,687.2 ₹69,687.20 | 78,500 ₹78,500 | 53,000 ₹53,000 |
| 8.00 | Lumpsum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part- VII, complete all as specied and directed. | 1 | Lumpsum | 6,24,800 ₹6.2 L | 7,50,000 ₹7.5 L | 7,00,000 ₹7 L |
| 9.00 | Lumpsum price worked out by the tenderer for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VIII, complete all as specied and directed. | 1 | Lumpsum | 5,15,000 ₹5.2 L | 4,00,000 ₹4 L | 3,50,000 ₹3.5 L |
| 10.00 | Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part- IX, complete all as specied and directed. | 1 | Lumpsum | 4,87,200 ₹4.9 L | 5,00,000 ₹5 L | 7,50,000 ₹7.5 L |
Updated dates
Tender Value
₹4.3 Cr
EMD Value
₹5.0 L
Closing Date
29 Oct 2025, 5:00 pmClosed
CHIEF ENGINEER A and N Zone
HQ CE A and N Zone MES Brichgunj Junglighat post Sri Vijaya Puram Pin - 744103
PROVISION OF CENTRALISED FIRE DETECTION AND CONTROL SYSTEM AT NSRY PORT BLAIR
2025_MES_731291_1
801252/E8
Open Tender
Civil Works
730 days
port blair
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,000
GE HADDO
₹5.0 L
Yes
12 Mar 2026
17 Sept 2025
31 Oct 2025
17 Sept 2025
29 Oct 2025
15 Oct 2025
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part - I to XIII are prepriced by MES under Ser No. 02 to 14. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the tenderer for "BUILDINGS/STRUCTURES" as listed in Schedule ‘A’ Part- I, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "EXCAVATION & EARTHWORK " as listed in Schedule ‘A’ Part- II , complete all as specied and directed.
Lumpsum price worked out by the tenderer for "INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part- III, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "INTERNAL ELECTRICFICATION " as listed in Schedule ‘A’ Part- IV, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "ROAD /PATH/ CULVERT " as listed in Schedule ‘A’ Part- V, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part- VI, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part- VII, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VIII, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part- IX, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "AIRCONDITIONING & COOLING APPLIENCES" as listed in Schedule ‘A’ Part- X, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "RCC OVERHEAD TANK STAGING" as listed in Schedule ‘A’ Part- XI, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "PILE FOUNDATION" as listed in Schedule ‘A’ Part- XII, complete all as specied and directed.
Lumpsum price worked out by the tenderer for "DEMOLITION OF BUILDING" as listed in Schedule ‘A’ Part- XIII, complete all as specied and directed.
Subtotal
NOTE: Schedule ‘A’ Part - XIV "MICELLANEOUS ITEMS" is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
SCH 'A' Part IV ( INTERNAL ELECTRIFICATION )
Supply and fix Bulb 1x09 Watt,230 V, AC Suitable size complete all as specied and directed.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised wire 4 mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete
Schedule ‘A’ Part- VI (SEWAGE DISPOSAL)
M&L for RCC Septic tank for 100 users :-RCC Septic tank Conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., with effective depth of 1.5 meter and overall depth of 3 meter complete all as shown on drawing CE/TD/2022/16 Sht 1/1 as directed and specified.
Soakage well 3.0 M dia X 3.0 M effective depth :- M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of suitable size complete all as shown on drawing CE/TD/2022/17 Sht 1/1 as directed and specified.
SCH 'A' Part VIII (EXTERNAL WATER SUPPLY)
S&F Gunmetal gate valve, 50 mm bore conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, as fixed in repairs complete all as specified and as directed
S&F Gunmetal gate valve, 80 mm bore conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, as fixed in repairs complete all as specified and as directed
M&L for cutting the existing bituminous/ cement concrete road to any length and width but 90cm in depth as required at site for laying galvanised steel tubing as protection pipe for cable including earth work excavation in any type of soil, RFR and removing surplus soil as directed and making good the disturbed top surface.
Supply, install and commissioning of cast iron centrifugal monoblock pumpset of 5 HP capacity having discharge of minimum of 11.8 LPS, Model No.KDS 527, pipe size 80 x 65 mm dia and head of 28 meter operating voltage of 415V and 50 Hz AC supply includign Brass NRV of suitable size suitable motor starter and copper conductor multistanded with PVC conduit for wiring from panel board to pump and suction and delivery pipes along with brass foor valve & strainer complete all as specified and directed. Make : Kirloskar Brothers Ltd / CG / KSB
M&L for construction of Brick Masonary valve chamber of size 900x900x900mm (internal dimensions) with PCC 1:4:8 foundation 100mm thick, brick work using PCC block masonary 200 thick wall built in CM 1:6,PCC 1:3:6 coping 50mm thick, plastering 15mm thick in CM 1:6 to all internal wall including floor,and exeternal wall upto 150mm below ground level, including excavtion earth work in hard/dense soil, MS sheet cover 4mm thick with locking arrangement with ISA 50x50x6 mm frame embedded in PCC and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed
supply & fixing of out door type dust & vermin proofJuction box panel powder coated with canopy by using suitable angular iron frame for each unit panel fixing with nuts & bolts on 40 x 40 ICMS channel as per directions using 3.15 mm thick CRCA sheet all over body front and back cover with hinges and aldrops for locking armagments duty 1 mm thick FRP coated all over external surfaces and 2 mm thick MS sheet for comprising of following items :- (a) MCB 63 Amps three phase 415 volt, 50 HZ (b) DOL Stater up to 7.5 HP three phase 415 volt, 50 Hz
SCH 'A' Part IX (EXTERNAL ELECTRIC SUPPLY)
Fabricate supply & fixing of out door type dust & vermin proof LT feeder pillar box panel CPRI approved with canopy by using suitable angular iron frame for each unit panel fixing with nuts & bolts on 70 x 40 ICMS channel as per directions as per directions of Engineer-in-Charge and using 3.15 mm thick CRCA sheet all over body front and back cover with hinges and aldrops for locking armagments duty 1 mm thick FRP coated all over external surfaces and 2 mm thick MS sheet for bus bar cover panel partitions and bottom cable entry covers duty painted with ONE coat of redoxide and two coats of synthetic enamel paint with control wiring to complete LT panel with 1.5 Sqmm FRLS copper cable and 6 A MCB's meters breaker control supply and indication lamps and the following switch gears /ACB's copper bus bars and accessories : Aluminium bus bar of 200A for RYB (live) and 200A for neutral as main bus bar. Aluminium bus bar as down links/connectivity links to LT MCCBs for connecting all incoming , outgoing cables and bus couplers. Digital ammeter & voltmeter for incoming Make: Schnider / Elmeasure. LED indication lamps for RYB for incoming supply and for breaker on / off indications. 1. 4 Pole MCCB - 100 A as incomer and, 4 Pole MCCB 63 A MCCB - 4 no's and 20A single phase timer with power contactor as outgoings all as directed All MCCBs of 4 pole 25 KA, 440 V AC with thermal triping system against Short circuit instantaneous and earth fault protection all as specified and directed. 2. The panel board shall conform as per IP 55
NOTE: (i) Rate quoted includes necessary grouting / chipping of concrete for Anchring fastners and making PCC foundation to fix the LT Panel and connecting of necessary LT cables with new end terminations as directed by the engineer - in - charge. (ii) Rate quoted includes necessary Digital ammeter, voltmeter, LED lamps, CTs, Aluminium bus bar and MCCB's (iii) Drawing must be got approved by Engineer-in-Charge fabrication of the panel.
Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanized earth strip 32 x 6mm connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance not exceeding 50 metre, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I NOTE:- (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete
Supply & fix FRP pole box 170 x 170 x 105mm consisting of 50 Amps 4 pole connector- 01 No MCB SP "C'' curve 06 Amps, 10 KA-01 no complete all as specified and directed. Makes : FRP Pole Box : SINTEX Cat No. GS-JB-1414 or equivalentmodel in other brands as per list of makes.
Supply and fixing LED Bollard with round top 20 W ,220V 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation, cable conduits for loop in and out , cable connectors including copper conductor cable of 2.5 Sq mm 3 core copper conductor cable drawn in conduits for loop in and out, cable connectors complete all as specified and directed. Make : Crompton Greaves cat Part No LBLSN-10-CDL or equivalent model in other brands as per list of makes.
S&F 60 watt solar top LED fitting of minimum 100 lumens per watt capacity (with solar panel RAL black lamp ux-2000 lm luminaire wattage 270W, stand alone solar LED post top with maintenance free battery LiFePO4 25-6V 30Ah=768Wh battery inbuilt inside the pole, solar panel of mono crystaling type , pole made of aluminium alloy CCTcolour temperature =5700K CRI>70, battery compartments with IP 65, battery dimensions 120mm x 146mm x 470mm operating temperature 0º to 60º C, PV module mono panel SI, 180 Wp / 23 Voc, panel dimensions 172mm x 172mm x 2000mm, total height of pole minimum 6 mtrs, with 5700K colour temperature with beam angle 120º pressure die cast aluminium housing with corrosion resitance polyester powder coated with complete internal wiring fibre glass insulated multi strand wire including PCC foundation with all arrangement including testing and commissioning complete all as specified and as directed. MAKE: Bajaj Cat part No.BSZSL or equivalent model in other brands as per list of makes.
Disconnecting existing LT UG cables of size 3.5 core 50 to 95 sq mm and draw out from the pipe, wall or in under grond from duct / trench/wall near fire station NSRY including re laying the same in trenches/ ducts/pipe or in walls with necessary clamping all as specified and as directed. Note:Necessary excavation will be measured and paid seperately.
Disconnecting existing LT UG cables of size 3.5 core 120 to 150 sq mm and draw out from the pipe, wall or in under grond from duct / trench/wall near fire station NSRY including re laying the same in trenches/ ducts/pipe or in walls with necessary clamping all as specified and as directed.. Note:Necessary excavation will be measured and paid seperately.
Disconnecting existing LT UG cables of size 3.5 core 300 to 500 sq mm and draw out from the pipe, wall or in under grond from duct / trench/wall near fire station NSRY including re laying the same in trenches/ ducts/pipe or in walls with necessary clamping all as specified and as directed. Note:Necessary excavation will be measured and paid seperately.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specied and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Indoor/Outdoor type complete all as specied and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 120 to 150 sqmm,Indoor/Outdoor type complete all as specied and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 sqmm,Indoor/Outdoor type complete all as specied and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 300 to 500 sqmm,Indoor/Outdoor type complete all as specied and as directed.
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 40 mm (OD) x 32 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed.
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 50 mm (OD) x 38 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed.
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 63 mm (OD) x 50 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed.
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 180 mm (OD) x 152 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed.
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 200 mm (OD) x 175 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed.
SCH 'A' Part X (AIRCONDITIONING & COOLING APPLIANCES)
S&F voltage stabilizer copper wound 4.0 KVA suitable for wall mounting (Automatic operation) single phase naturally cooled suitable for input voltage 165 V to 295 V stablizer output voltage 200 to 240 Volts with time delay 2 to 4 minuts complete all as specied and as directed..
Supply,installation, commissioning of Water cooler stainless steel, electric driven single phase having approx storage and nominal cooling capacity as 40/80 ltr complete all as specified and directed. Make : Usha Model No. SS4080 or equivalent in Bluestar / Voltas
SCH 'A' Part XI (RCC OVERHEAD TANK STAGING)
M&L for applying a coat of reflective bitumenous aluminium paint @ 0.15 Kg / sqm over APP membrane surface complete all as specified and as directed.
SCH 'A' Part XII (PILE FOUNDATION)
Drilling/boring through any type soil (Clayey sand/silt and clay mix) upto the depth as directed/ indicated for 500 mm outer dia bored cast-in-situ, vertical piles duly stabilising the sides by drilling fluids (Auger Boring/ DMC Boring method) the method of boring will be approved by GE based on site condition before execution of work, and disposal of drilled/bored material to a distance exc 1.50 Km and n.exc 5.00 Km all as specified and shown on drawings.
Carrying out initial pile load test on 500mm as per IS-2911 Part IV 2013 for 2.50 times the safe design load as per structural drawing including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion of work and submitting the initial pile load test in qudaruplicate by approved consultancy duly signed by all concerned with site photography etc, complete all as specified and directed.
Carrying out Routine pile load test on 500mm as per IS-2911 Part-IV- 2013 for 1.50 times the safe design load as per structural drawing including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion of work and submitting the routine pile load test in qudaruplicate by approved consultancy duly signed by all concerned with site photography etc, complete all as specified and directed.
Carrying out standard penetration test (SPT) for all as per IS 2131 at levels and locations of cast-in-situ bored piles all as per for 500mm dia complete all as specified and as directed.
Carrying out/conduction pile integrity test using Low strain dynamic method all as per IS for 500mm dia piles complete all as specified and as directed.
SCH 'A' Part XIII (DEMOLITION OF BUILDING)
Taking down old unserviceable submain wiring of any size
Taking down fuse Unit/DBs, 415 Volt/230 Volt incl MCCB/MCB
Taking down light fittings of any type complete all as directed.
Taking down old unserviceable LT cable / service wire of any size.
Taking down old unserviceable GI pipe line 25/40 mm dia
Subtotal
P NAIDU (BID ID -3457219)
City Constructie Pvt Ltd (BID ID -3456943)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
MainDrgCFDCcompressed.pdf
Additional Documents • 14.05 MB
801252TenderPages.pdf
Tender Documents • 1.35 MB
TDCFDScompressed.pdf
Additional Documents • 5.06 MB
801252prepricedSch.pdf
Additional Documents • 0.39 MB
801252PS.pdf
Additional Documents • 1.61 MB
BOQ_818752.xls
BOQ • 4.27 MB
Download all tender documents and submit your bid