| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹36.0 L+₹3.8 L (11.7%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹38.4 L+₹6.2 L (19.2%)Rejected-Finance 37 A 19 3 B MADHU NAGAR AGRA UP | AGRA | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹44 L+₹11.8 L (36.5%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹45.5 L+₹13.2 L (41.0%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI BIJENDRA SHARMA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8528/E8
2023_MES_597720_1
8528/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VASCO
Class D Category b i
7 documents required · 7 mandatory
₹500
GE NW VASCO
₹90,000
Yes
21 Jul 2023
24 May 2023
15 Jun 2023
24 May 2023
13 Jun 2023
7 Jun 2023
25 May 2023 - 6 Jun 2023
Amount
Taking down old unserviceable post top lantern & repair /replacement of old post top lantern LED type 40W 230 Volts AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with inmpact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Taking down old unserviceable post top lantern & repair /replacement of old post top lantern sturdy LED 10W bollard with excellent light output its leek PMMA window ensuring maximum illumination aspect in surrounding complete with driver and lamp including mounting base plate and mounting studs and bolts acessories complete. Make:- Havells Cat Part No: - MINIMOUNTBL10WLED 830PSYMTOPMMAM(1.0 M) or equavalent in Bajaj/ Phillips/ Surya / Crompton etc.
Taking down old unserviceable post top lantern & repair /replacement of old post top lantern LED type 40W 230 Volts Ac outdoor type made in die cast aluminium with innovative glare free indirect lighting distribution & IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed
Taking down old unserviceable post top lantern & repair /replacement of unserviceable gardern LED spike / bush light 9W with die cast aluminium housing designed for rugged outdoor usage & 230 Volts AC & IP 65 protection with inmpact and corrosion resistant complete with driver and lamp complete all as specified and as directed
Taking down old unserviceable post top lantern & repair /replacement of old post top Lantern LED type 45W 4000K illumination, 230 Volts AC outdoor type made in die cast aluminium with innovative glare free indirect lighting distribution & IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Taking down old unserviceable post top lantern & repair /replacement of LED light column type 50W 3000 K LED RGB 3M illumination, 230 Volts AC outdoor type made in die cast aluminium with innovative glare free indirect lighting distribution & IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
M&L for earthing with GI earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and as directed
M&L for galvanised Galvanised iron strip 32 x 6mm buried in ground including connecting nut, bolt and inter linking with earth point with protection pipe and complete all as specified and as directed.
M&L termination rod single pointed made of aluminium rod 12 mm dia and 300 mm long fixing on roof with aluminium strip complete all as specified and as directed.
M&L for test point terminal block made of gun metal or phosphorus bronze of size 75 x 75 x 25mm drilled and screwed including 3 Nos 8mm dia long hex screws and complete all as specified and as directed.
S&F 40mm dia light grade steel tubing along the fitting grouted on floor with PCC (1:3:6) at junction point of aluminium strip to mount the air termination rod of 12 mm dia 300 mm long to arrest the lightening and complete all as specified and as directed.
M&L for Chemical earthing with copper earth plate of size 900 x 600 x 5 mm & copper earth strip 32 x 6 mm buried in ground vertically to a depth not less than 3.0 metre below ground level with top edge earth electrode at a depth not less than 2.40 metre deep below ground level including suitable quantity of backfill chemical compound for filling in each pit to cover earth electrode minimum 100 mm all around and electrode shall be jointed with the copper strip of size 32 x 6 mm by exhothermic weld complete with earth pit chamber of size 300 x 300mm and RCC cover including necessary earth work excavation, PCC chambers, RCC cover slabs with 10m dia CTD bars 100 cc both ways, funnel, mess, 50mm dia light grade GI protecting pipe, 20m dia light grade waking pipe funnel with mess etc for demarking the location of earth electrode location complete all as specified and as directed.
Note :- (i) The quantity of Backfill compound and depth of earth pit can be increased by the contractor without any extra cost to Govt. The Contractor shall ensure that earth resisitance shall be less than 1 ohms on completion and testing. The testing of each earthing shall be carried out in presence of Engr-in-charge and test results shall be submitted duly signed by all concered while claiming payments. (ii) Earth strip with protection pipe 50mm GI light grade upto 7.5 meter is deemed to be included in the rates quoted.
Taking down old unserviceable solar light complete and supply & install all in one mini mast high efficiency premium solar integrated street light semi mast with built in MONO crystalline panel, lithium Ferro Phosphate (LiFePO 4) battery charge controller and PIR sensor with colour temperature 6000-6500 K 2 days autonomy with dimming profile 30 watt x 4 allin one integrated system including 7M long Octagonal pole and necessary pole foundation such as excavation of size 0.6 x 0.6 x 1.5m complete PCC filling in PCC 1:4:8 type D2, PCC coping in PCC 1:3:6 complete all as specified and as directed.
sapna enterprises
M/S J J ENTERPRISES
star freeze service
OM SAI ELECTRICALS
Susheel Enterprises
Shree Ram Enterprises
D.K. ENTERPRISES
Sai Supreme Constructions
SHIVANI ENTERPRISES
S and G Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .