Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹43.6 L+₹3.7 L (9.30%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance Second Lowest amount quoted | |
| 3 | L3₹43.9 L+₹4.0 L (10.1%)Rejected-Finance | L3 | Rejected-Finance Third Lowest amount quoted | |
| 4 | L4₹46.0 L+₹6.2 L (15.5%)Rejected-Finance 114 BARH CHONDI BARH PATNA BIHAR 803213 | PATNA | PATNA | BIHAR | 803213 | L4 | Rejected-Finance Highest amount quoted |
| Sl No | Description | Qty | Unit | MAA SHARDA CONSTRUCTION L4 | M/s Ajayshwar Singh Rana L1 | SRI SAI CONSTRUCTION COMPANY L2 | titiksha india L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches for laying of GI water tubing etc, getting out in soft/loose soil n.exc 1.5m wide and n.exc 1.5m depth complete all as specified and directed. | 180 | Cum | 150 ₹27,000 | 250 ₹45,000 | 80 ₹14,400 Lowest | 180 ₹32,400 |
| 2.00 | Returning, filling in trenches including spreading, leveling, watering in layers n.exc 25cm thick without damaging pipes/special fittings as in any type of soil complete all as specified and directed. | 120 | Cum | 45 ₹5,400 | 150 ₹18,000 | 25 ₹3,000 Lowest | 55 ₹6,600 |
| 3.00 | Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. | 60 | Cum | 70 ₹4,200 | 100 ₹6,000 | 30 ₹1,800 Lowest | 55 ₹3,300 |
| 4.00Taking down existing unserviceable GI pipe & Supply and laying in trenches, fixed to walls, ceilings, steel water tubing galvanised medium grade and connection including fittings like Tee, Bend, Socket, Elbow, Short pieces connectors, plugs, and unions etc, cutting/threading of the following sizes complete all as specified and directed. Note : Earth work shall be measured and paid seperately | |||||||
| 4.01 | 20 mm dia | 200 | RM | 210 ₹42,000 | 185 ₹37,000 Lowest | 250 ₹50,000 | 255 ₹51,000 |
| 4.02 | 25 mm dia | 60 | RM | 270 ₹16,200 | 267 ₹16,020 Lowest | 360 ₹21,600 | 315 ₹18,900 |
| 4.03 | 40 mm dia | 24 | RM | 410 ₹9,840 | 391 ₹9,384 Lowest | 550 ₹13,200 | 420 ₹10,080 |
| 4.04 | 50 mm dia | 12 | RM | 510 ₹6,120 Lowest | 540 ₹6,480 | 640 ₹7,680 | 525 ₹6,300 |
| 5.00M&L for cast iron pipe spigot and socketed centrifugally cast class LA in any length laid in trenches including taking down old unserviceable CI pipe for the following sizes complete all as specified and directed. | |||||||
| 5.01 | 100 mm dia | 6 | RM | 1,800 ₹10,800 Lowest | 1,850 ₹11,100 | 2,000 ₹12,000 | 1,820 ₹10,920 |
Tender Value
₹49.5 L
EMD Value
₹99,100
Closing Date
4 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col P Aditya Deepak, GE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
Various EM and water supply maintenance work of CDA office complex and residential area at Lekhanagar at GE (East) Jabalpur (As per Tender Document)
2025_MES_710595_1
8751/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
Class D Cat a (ii) and b (i)
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (East) Jabalpur
₹99,100
Yes
9 Aug 2025
27 May 2025
7 Jul 2025
27 May 2025
4 Jul 2025
19 Jun 2025
27 May 2025 - 4 Jun 2025
Amount
Excavation in trenches for laying of GI water tubing etc, getting out in soft/loose soil n.exc 1.5m wide and n.exc 1.5m depth complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering in layers n.exc 25cm thick without damaging pipes/special fittings as in any type of soil complete all as specified and directed.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Taking down existing unserviceable GI pipe & Supply and laying in trenches, fixed to walls, ceilings, steel water tubing galvanised medium grade and connection including fittings like Tee, Bend, Socket, Elbow, Short pieces connectors, plugs, and unions etc, cutting/threading of the following sizes complete all as specified and directed. Note : Earth work shall be measured and paid seperately
20 mm dia
25 mm dia
40 mm dia
50 mm dia
M&L for cast iron pipe spigot and socketed centrifugally cast class LA in any length laid in trenches including taking down old unserviceable CI pipe for the following sizes complete all as specified and directed.
100 mm dia
150 mm dia
M&L in replacement of lowering GI pipe heavy grade of size 80mm dia alongwith GI socket and other connections, in 3 meter length, complete all as specified and directed. Note : All T&P required for execution will we arranged by Contractor.
M&L to attend breakdown complaints like no water supply in service tank, pipe line leakages of size upto 50 mm dia. etc and also removing air lock in married / OTM accommodation with the help of required tools and including GI fittings of any size/dia like union, elbow, tee, bend, nipple, socket etc required at site including excavation & return filling, if required, for rectification of leakage of GI pipe complete all as specified and directed. Note : Rate of fittings like union, elbow, nipple, bend, socket etc of required size shall be included in the unit quoted rate.
Rectification/arresting of leakage in the under ground CI/DI water pipe line 80mm to 200mm dia including necessary excavation and filling in wet condition, taking out of existing pipes/cutting of pipes, stoping of water leakage, repairs of CI pipe line burning out/ removing lead joint and refixing pipe/ fitting in original position re-aligning to existing CI collars at both ends, testing of leakage complete all as specified and directed. NOTE: (a) Cast iron pipe, if replaced, shall be measured and paid separately under relevant items. (b) Lead, lead wool, if required for stopping the leakage shall be supplied by the contractor without extra cost. (c) Cost of excavation & return filling will be deemed to be included in the quoted unit rate.
Lifting/ taking out defective submersible pump set upto 15 HP alongwith column pipe of any size and submersible cable , dismantling the pump from motor, setting aside for repair /servicing / overhauling including lowering the pump set into borewell including replacement of packing and nut bolts ( if required) and testing after the completion of repair works in the presence of Engr in charge complete all as specified and directed.
Rewinding to submersible pump 15 HP of any make with super enameled copper winding wire PVC coated of same gauge, providing PVC separators , PVC sleeves and jointing compound complete all as specified and directed. Note :- Replaced items will be measured and paid seprately under relevent item.If the same motor copper winding wiring burnt second time in the above CA Period, The contractor is responsible to paid and rewind the same at their own cost.
Repair/ Replacement of following parts of the submersible pump and motor of capacity 15 HP of original company as approved by Accepting Officer complete all as specified and directed.
Thrust bearing plate made out of carbon for 15 HP submersible motor
Gun metal bush for 15 HP submersible motor
Shaft sleeve made out of stainless steel for 15 HP submersible motor
Clamp stud for 15 HP submersible motor
Rotor balancing of 15 HP submersible motor
Shaft grinding of 15 HP submersible motor
GM Neck Ring for 15 HP submersible pump
Stainless steel sleeve for 15 HP submersible pump
Stainless steel pump shaft for 15 HP submersible pump
Stainless steel impeller for 15 HP submersible pump
Cast iron bowl for submersible 15 HP pump
Rubber bush for 15 HP submersible pump
Coupling for 15 HP submersible pump
S&F in repair rotor assembly suitable for 12.5 HP, submersible motor, 1440 RPM, 440V, 50 Hz complete with bearing complete all as specified and directed.
S&F in repairs Stator assembly suitable for 12.5 HP motor, 1440 RPM, 440Volts, 50 Hz complete with frame core winding and terminal box complete all as specified and directed.
S&F in repair submersible pump assembly 12.5 HP, 1440 RPM not less than 9 lps at 120 Meter head, complete with brass impeller, shaft, shaft sleeve, pump casing, casing cover, bearing with housing and all accessories complete all as specified and directed.
M&L Flushing out / desilting of the bore well of any size by using compresser hydro pressure jet for six hours till clear the silt in the casing pipe by acheiving clear water, and washing with hydro pressure jet using foam/oils, disinfecting the bore using sodium hypochloride solution and washing out till water is obtained to the required turbidity (clean water) to the entire satisfacton of Engr-In-Charge complete all as directed,including Lowering and re-fixing of submersible pump set of capacity upto 15 HP at different places including pump set fitting commissioning and testing after replacement of defective parts with new one alongwith column pipe 50/80 mm bore with cable by suitable arrangment of chain pully system and connection with startor electrically and connection with pipe line mechanically and testing complete all as specified and directed.
M&L cutting of road, hard standing made of concrete or premix carpet, suitable for soling and moorum filling incl excavation for laying of pipe upto 150 mm dia, all as directed and making good the road / hard standing by using all old materials and with PCC (1:2:4) as required to match with the existing surface complete all as specified and directed.
M&L Construction of valve chamber of internal size 1200 x 1200 x 1200 mm suitable for 100/150 mm dia sluice valve including necessary earth work excavation PCC 1:4:8 in foundation type D2 using 40mm graded stone aggregate, brick wall in CM 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in CM 1:4 including provision of MS sheet cover 3.0mm thick with MS angle frame 25 x 25 x 3mm all round and at diagonals of size 40 x 40 x 6mm and also MS plate welded to MS angle, embedded in concrete with suitable hinges and locking arrangements, including two coats of synthetic enamel paint over a coat of red oxide primer necessary excavation earth work etc complete all as specified and directed.
S&F in repair gun metal gate valve (ISI) marked with iron wheel head screwed both ends for iron pipe suitable for following bore of pipe including taking down old existing gate valve complete all as specified and directed.
20 mm dia
25 mm dia
50 mm dia
Taking down old defective non return valve & supply and fix non return valve of size 100 mm dia with by pass arrangement working pressure 10 kg per sq cm confirming to IS- 5312 including jointing by means of rubber gasket 3mm thick, MS nut bolt, washers etc., including testing complete all as specified and directed.
Taking down old unserviceable Starter of any type/sizes and M&L Fully Automatic Star Delta Motor starter 17.5 HP in sheet-steel enclosure type MN .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-15 A complete all as specified and directed.
Taking down the existing unserviceable CI fittings and M&L for CI fittings confirming to IS for Spigot socket end pipes up to 150mm bore such as bends(any type, radius angle) Tapers any type (straight,bend,increasing,descreasing or double socket etc) T pieces, single branch,`Y` junction,double branch cross (all sockets or socket and spigot) collars, caps and plugs etc. complete all as specified and directed.
M&L cutting of CI pipe upto 150mm dia for insertion of new tees or branches 20/25/40 mm dia GI pipe complete drilled, welded and screwing Nut, bolts with MS clamp welded with GI socket 20/25/40 mm dia including earth work complete all as specified and directed.
S&F in repair sluice valve CI body double flanged and drilled conforming to IS-780 of 1980 PN-1.6 including rubber gasket 3 mm thick, stainless steel spindle, iron wheel head and suitable size of nuts bolts and washers including taking down old unserviceable sluice valves for the following sizes complete all as specified and directed.
Sluice valves 200 mm dia
Sluice valves 150 mm dia
Sluice valves 100 mm dia
Repairs to CI sluice valves by taking down worn out unserviceable gland sleeve, check nut, spindle, gate etc., and cleaning the valve by removing all scales and reassembling the valve with new packing, nut and bolts, new brass spindle, guttka etc for the following diameter complete all as specified and directed:-
200 mm dia.
150 mm dia.
100 mm dia.
S&F in replacement Altoch Dosing system consisting of Chlorine Dosing System ( Model No. Aqua 1006); - High flow rate of 0-25 LPH & High Pressure of 0-10 kg /cm2 and strokes / Minutes of Max-135 Min-15 with frequency conversion Motor. Including accessories injection Check Valve, Foot Valve and Discharge tubing 3 Mtrs. Accessories must include the following :- Service tank Model No. AQUA1006 of net capacity 100 ltrs. of FRP dosing tank Top dia 540 mm x Bottom dia 480mm x Height 575mm consisting of water inlet line, Dosing pump inlet arrangement, Drain, Overflow level gauge, inspection port, Agitator 120 watt 960 rpm signal phase flange mounted motor with plastic shaft and impeller, Provision of mounting lid, Pump fitted with mounted on heavy duty MS fabricated frame and painted with anticorrosive paint. Brand: Aquafit (ACDS), complete all as specified and directed.
M&L Calcium Hypochlorite 65% -75% Chlorine Content in a white or grayish white Granular solid Chemical. (Calcium based Granular disinfectant Chemical for potable Water treatment & Swimming Pool) in 45 Kgs each drum of Factory sealed HDPE Container complete all as specified and directed.
M&L monthly TDS,Chloride,Floride,Alkaline,E-COLI(bacteriological) water testing at both supply and receiving end. Sample shall be collected by contractor and testing be done at authorized/ Govt laboratory and report to be submitted monthly to the Engr-in-charge in triplicate copy complete all as specified and directed. Note:- Each job consist of 05 samples which is collected from different locations of borewells and OHT by contractor's own arrangment.
Supply only Chlorine Testing Kit by Orthotolidine method with all accessories (colour matching PPM tubes, water testing tubes, Orthotolidine solution and wooden Box) complete all as specified and directed.
S&F PVC Insulated 3 core Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts, 10 Sqmm suitable for submersible motor complete all as specified and directed.
M&L for trimming vegetation or small inequalities clearing all grass vegetation, saplings, shrubs, brushwood, roots inside the sump or valve pits, and tree of surroundings area including and removing rubbish upto a distance of 50 meters outside the periphery of the area under clearance of water supply installations and Sumps complete all as specified and directed.
M&L draining water from OHT up to 100000 gallon capacity reservoirs n.exc. 18 Mtr head/ staging, and cleaning internal portion of tank (bottom and walls) by means coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance n.exc 50 mtr including one coat of synthetic enamel paint on all steel surfaces such as ladder, railing, inlet & over flow CI pipes connected sluice valves of the respective OH tanks reservoir etc writing letters with white paint (date of cleaning and capacity of tank) on black painted surface of tanks complete all as specified and directed.
Taking down old unserviceable water indicator system of any type/ sizes and S&F Digital water leval indicator system 150 mm size digit direct display,operated on 230V AC, suitable for upto 20 metre height over head Reservior/ underground sump of any capacity, preadjustable alarm for upper & lower level, temp range -5 to 50 degree, humidity up to 90% RH, reset push switch for silent the alarm including 4 core 1.5 sqmm copper cable complete all as specified and directed.
NOTES :- 1.The time limit for attending the complaints on intimation to the contractor by the department shall be as under:- (a) Repair to motor/pump - within 2 days (b) Other Misc jobs- with in 1 day 2. In case the contractor fails to attend/rectify the defects within the above time limit, penalty will the imposed as Rs 1000/- per day in case of complaints/jobs mentioned at note 1 (a) & (b) above. 3. The contractor or his authorised representative shall report to concered JE or the Engineer-in-charge at 0930 hours daily on all working days to receive order/instructions of the work or regular complaints. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in -Charge / JE Concered.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreading thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and directed. Note : Punned thickness will only be measured for payment purpose.
M&L protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks complete all as specified and directed.
Taking down old unserviceable LT UG cable of any description and size complete all as specified and directed.
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testing of the following sizes and cross sectional area complete all as specified and directed. :- Note :- Necessary earth work to be measured and paid separately.
10 Sqmm, 2 core
10 Sqmm, 4 core
16 Sqmm, 4 core
25 Sqmm, 4 core
70 Sqmm, 3.5 core
95 Sqmm, 3.5 core
Taking out faulty UG cable by cutting faulty end and M&L joint using out door cable straight through jointing kit (Epoxy/Heat Shrinkable type) suitable for PVC/XLPE under ground aluminium conductor cable, 1100 Volts grade including crimping aluminium sockets of suitable size of following cross sectional area complete all as specified and directed :- Note : Excavation & earth work, sand cushioning, bricks for protection if necessary shall be measured and paid separately.
10 to 16 Sqmm 2/4 core
25 sqmm to 50 sqmm, 3.5/4 core
70 sqmm to 120 sqmm, 3.5 core
Boring of holes under road, pavement, hard standing, drain etc by conventional method not exceeding 5 mtr in length for inserting GI Pipe upto 80 mm dia complete all as specified and directed. Note : GI Pipe shall be measured and paid separately
M&L cutting the existing bituminious road/ pavement/ footpath including taking out paver block wherever and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road or refixing unbroken paver block complete all as specified and directed. Note :-M&L for laying of pipe shall be measured and paid separately.
S&F in repair, GI pipe 80mm bore, light grade, laid below road / fixed along the poles / walls with necessary clamping, etc complete all as specified and directed
All as per item No 40.00 above, but GI pipe of size 50 mm bore.
M&L detecting of fault in 1100 Volt cable of any size upto 120 Sqmm 3.5 core laid in trench fault locating machine comprising of surg generator pulse, ECHO fault locator with high frequency distance calculator etc and exposing the cable fault,removal of deteriorated portion of cable , treating of cable and making the same ready for jointing work complete all as specified and directed
Disconnecting all cable connections and taking out u/s MCCBs/ACB any type/capacity upto 630 Amps, TP/FP/TPN, 415 Volt from Panel Boards/feeder boxes and remove from site complete all as specified and directed.
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, 350 Amps, Ics=100% of Icu, 415 Volts AC with all accessories & copper spreader complete all as specified and directed
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, 250 Amps, Ics=100% of Icu, 415 Volts AC with all accessories & copper spreader complete all as specified and directed.
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, 160 Amps, Ics=100% of Icu, 415 Volts AC with all accessories & copper spreader complete all as specified and directed.
S&F in repair MCCB, 4 pole, 16 KA, with thermal magnetic release, 100 Amps, Ics=100% of Icu, 415 Volts AC with all accessories & copper spreader complete all as specified and directed.
S&F in repair MCCB, 4 pole, 16 KA, with thermal magnetic release, 63 Amps, Ics=100% of Icu, 415 Volts AC with all accessories & copper spreader complete all as specified and directed.
M&L repair/ maintenance to LT panels, cleaning of panel, welding of joints if any, replacing damaged, bolts and nuts, painting with one coat of primer and one coat of smoke gray paint, disconnecting all lugs from bus bar, cleaning and removing any scales with sand paper,reconnecting all the connections, fixing of panel, if required as per direction, in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate and surface dressing and proper laying of XLPE electrical cable of any size and capacity nearby the LT Panel after disconnecting all incoming and outgoing connection complete including cleaning of grass nearby the LT Panel upto 2mtr all around complete all as specified and directed. Note : Rate of necessary earthwork as required at site shall deemed to be included in the quoted rate.
Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor / pedestal mounting type mounted on floor / pedestal, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3.15 mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 1000Amps rating for phase and neutral 4 strips with colour coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring using suitable size of PVC insulated, multi stranded copper conductors with all connected accessories, duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, cable gland and lugs for incoming and outgoing cable, connecting to earthing etc., necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, independent multilayer chambers to accommodate accessories including dismantling the unserviceable LT panel board from the existing position after disconnection of all electrical connections complete all as specified and directed with and including the following accessories :- NOTE : (a) Design / Drawing / BOM of the LT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. (b) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
MCCB 4pole, 630Amps, with adjustable thermal and magnetic settings, 50KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
MCCB 4pole, 400Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
MCCB 4pole, 250Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 02 No (Outgoing)
MCCB 4pole, 125Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
MCCB 4pole, 63Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 02 No (Outgoing)
Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
S&F in replacement of Air Circuit breaker of capacity upto 4 pole Microprocessor released type Drawout type of capacity 1250 Amps as per existing model & make complete all as specified and directed.
S&F on load Change over switch with sheet enclosure type 200 amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and directed.
M&L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations complete all as specified and directed. Note: (a) The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. (b) The cost of earth pit is deemed to be included in the unit rate.
Dismantling of unserviceable concrete/steel tubular pole any size upto 9 mtr long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and exc 1.5 mtr but n.exc 3.00 mtr in depth, for foundation of poles/ stays etc and and getting out in soft/loose soil complete all as specified and dirtected.
M&L PCC 1:4:8 type D2 by using 40 mm graded stone aggregate as in filling & mass concrete complete all as specified and directed.
M&L PCC (1:2:4), type B-1, by using 20 mm graded stone aggregate as in coping including necessary formwork complete all as specified and directed
M&L PCC 1:3:6 type C1 by using 20 mm graded stone aggregate as in coping of pole etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.
S&F Steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with MS base plate, finial taper plug, bolts, nuts, screws and top cover, including the following complete all as specified and directed. :- (a) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer, preparation of surface including painting of 30cm wide blue bands 3 Nos with synthetic enamel paint in alternate layer upto the height of 1.5m above plinth block. (b) Material and labour for writing letter or figures (Block, Roman, italic as Indian) with thick synthetic enamel paint of approved shade not exc height in numbering of pole all as directed. (c) Drilling a 02 Nos of hole to LT Pole (one hole near street light bracket and another near bus bar at bottom side) for insert of cable for street light.
M&L painting to electric pole steel tubular/ PCC of any length after removing /scraping/ bruses/ cleaning to old paint on external surface in two coats of paint over one coat of red oxide primer by using aluminium paint on steel tubular and cement paint on PCC poles in any height/ length/ dia etc including cross arms/ angles, nut, bolt , washers etc and making alternate strips of yellow and black paint in 30 cm minium width upto 1.5 Mtr above normal GL and writing Pole No and two coats of plastic emulsion paint on concrete/ plaster surfaces (pole coping) of any description over 10 cm girth or width complete all as specified and directed.
S&F repairs two single core PVC insulated cables 2.5 Sqmm size, 1100 Volt grade with copper conductor and drawing into street light brackets/PVC Conduits and connecting with Junction Box and Street light fittings including continuous PVC insulated copper conductor single core earth continuity conductor of size 1.5 Sqmm complete all as specified and directed. Note : Two runs of 2.5 sqmm cable, one run of 1.5 sqmm cable and one run of PVC conduit will be measured as one length.
S&F repair Cable junction box for street lights of size 250 x 250 x 155 mm IP 54 with integrated membranes/metric knockouts for cable entry of 10 to 25 Sqmm LT UG cable suitable for 415 voldts, 50 Hz, 3 phase 4 wire including clamp made out of MS flat 30 x 5 mm, nuts, bolts, washers etc with terminals complete and mounted on security light pole complete all as specified and directed.
S&F replacement, Brackets for street light fittings made out of 40 mm bore Light grade GI pipe, 1.5/2.0 Mtr length, bend to shape, painting the bracket with one coat of red oxide and one coat of aluminum paint including necessary Clamps made out of MS flat iron, nuts and bolts suitable for fixing with steel tubular/PCC Poles complete all as specified and directed.
Taking down old serviceable/ unserviceable street light/ flood light fittings for use with LED lamps of capacity upto 200 watts complete with all accessories and keep the serviceable fittings in safe custody for reuse and remove the unserviceable fiitings from site complete all as specified and directed.
Fixing only serviceable/ repaired light fittings of any size and make retrieved against item No 64 here-in-above complete all as specified and directed.
S&F 60 watt LED street light fittings, 230 V, IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary electric connection with suitable size copper cable after and including taking down existing unserviceable fittings complete all as specified and directed.
S&F LED flood light fitting of capacity 70 Watt in aluminium PDC housing with LED lamp, toughened glass cover with IP66 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting at any height and testing after and including taking down existing unserviceable fittings complete all as specified and directed.
S&F LED flood light fitting of capacity 100 Watt in aluminium PDC housing with LED lamp, toughened glass cover with IP66 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting at any height and testing after and including taking down existing unserviceable fittings complete all as specified and directed Note : Necessary T&P required at site for repair of High Mast light is deemed to be included in quoted rate
S&F repairs Glow sign board of size 2.0 m x 0.9 m x 0.20 m made out of 1.0 mm thick tin sheet all side except front side aluminium beading "L" shape at all boarder exterior and interior side, front should be acrylic cover 2.0 mm thick of blue colour and written the subject matter as given by the Engr-in-charge in english capital letter in white colour with twin tubelight fitting 1x 20 watt (2 nos) including all electrical connection with surface conduit wiring 1.5 Sqmm (length n. exc 8 meter) copper wire with drilling and necessary required arrangement for fixing of board including testing as complete all as specified and directed.
Supplying and laying synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supply, install, testing & commissioning of LT bus bar chamber of size (0.60x0.60x0.60)m, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on platform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete including PCC foundation comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: MCCB 200 amps, 4 pole,415 Volt Adjustable type with breaking capacity 36 KA, and 100 % Icu fitted with bus-bars shall be made up of 04 Nos Aluminium 400 A rated not less than 40mmx10 mm, duly insulated with 1100 V grade standard colour coded PVC sleeves PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INSTRUMENTATION SYSTEM : (a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (b) 3 Ph Digital Voltmeter CI 1.0 - 01 No (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 01 Nos. NOTE : 1) Design / Drawing / BOM of the LT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
S&F in repairs, Post Top lantren LED fitting Alumininum sheet spun Polyurethane Paint (With Prior Treatments) canopy & transparent Imported acrylic cover ) suitable for 45 Watt LED light Cast aluminum Spigot pole entry : 60 mm complete with IP 65/66 protection and pre-wired and necessary mounting arrangements and provision of 2.5 sqmm three core copper conductor cable multistranded from ceiling rose to light fitting complete all as specified and directed.
S&F repairs, LED Bollard light, system wattage-10/12W, inbuilt surge protection-4kv, warm white, lumens not less than 900, Helios Antique Black fixture (Big) , IP65, dimension 800mm x 170 mm X 170 mm, including PCC for fixing complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, holders, pendants, regulators, sockets etc and making good disturbed surface by using cement mortar, white cement, putty etc and match with existing surfaces of walls, floors etc complete all as specified and directed.
Taking down carefully any type of old unserviceable submain wiring with PVC/steel conduit surface / concealed or wooden battens etc and making good the disturbed surfaces to match with the existing surface complete all as specified and directed.
M&L for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into and concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylum sheet/plastic laminated white sheet cover for mounting normal/modular switches, sockets, fan regulators fixed with CP screws with cup wahsers as required and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 with putty to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point controlled by one switch. Note:- (a) Cost for cutting chases and concealing the conduit pipe in existing wall is deemed to be included in the item rate quoted. (b) Conduit will not be concealed in ceiling but fixed on ceiling surface only.
All as per item No 77 above but for one Fan Point controlled by one switch complete all as specified and directed.
All as per item No 77 above but for one Bell Point controlled by one switch complete all as specified and directed.
All as per item No 77 above but for one socket point 5 Amp controlled by one switch on same board complete all as specified and directed.
All as per item No 77 above but for one socket point 5 Amp controlled by one switch on Independent board complete all as specified and directed.
All as per item No 77 above but for one light point controlled by two way switch complete all as specified and directed.
All as per item No 77 above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified and directed.
M&L point wiring with three layer PVC Insulated 1.5 Sqmm multi-stranded copper conductor FRLS cable 1100 Volts grade drawn into existing PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick plastic laminated white sheet cover for mounting normal/modular switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces for One light Point controlled by one switch complete all as specified and directed.
All as per item No 84 above but for one Fan Point controlled by one switch complete all as specified and directed.
All as per item No 84 above but for one Bell Point controlled by one switch complete all as specified and directed.
All as per item No 84 above but for one socket point 5 Amp controlled by one switch on same board complete all as specified and directed.
All as per item No 84 above but for one socket point 5 Amp controlled by one switch on Independent board complete all as specified and directed.
All as per item No 84 above but for one light point controlled by two way switch complete all as specified and directed.
All as per item No 84 above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified and directed.
M&L drawing the wire in with casing caping or conduit complete with point wiring with FRLS PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface for one light/ Fan / Bell Point controlled by one switch complete all as specified and directed.
All as per item No 91 above but for one socket point 5 Amp controlled by one switch on same board complete all as specified and directed.
All as per item No 91 above but for one socket point 5 Amp controlled by one switch on Independent board complete all as specified and directed.
All as per item No 91 above but for one light point controlled by two way switch complete all as specified and directed.
All as per item No. 91 here in above but drawing in with casing caping or conduit on surface all as directed complete with point wiring using 2.5 Sqmm (Nominal area) tripple layer FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 2.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete all as specified and directed.
M&L Sub main wiring with two single core PVC Insulated cable two runs of size 4 Sqmm multi-stranded copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, concealed or on surface as per directed, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and directed. Note : - Two run of 4 Sqmm & one run of 4.0 Sqmm cable including one run of 20mm conduit shall be measured as one unit run.
M&L Sub main wiring with two single core PVC Insulated cable two runs of size 6.0 Sqmm multi-stranded copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, concealed or on surface as per direction, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two runs of 6 Sqmm & one run of 6 Sqmm cable including one run of 25mm dia conduit shall be measured as one unit run.
M&L of Sub main wiring with two single core PVC Insulated cable two runs of size 10.0 Sqmm multi-stranded copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, concealed or on surface as per direction, medium grade not less than 25 mm dia with all conduit accessories and one run of 10.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 10 Sqmm & one run of 10 Sqmm cable including one run of 25 mm dia conduit shall be measured as one unit run.
M&L for wiring with four single core, multi stranded, PVC insulated, 1100 Volt grade, FRLS, cable with copper conductor of size 10 Sq mm in and including/drawing through rigid non metalic PVC conduit, concealed or on surface as per direction, medium grade not less than 25 mm dia with all conduit accessorie including continuous PVC insulated copper conductor single core earth continuity conductor of size 10 Sqmm connected common earth complete all as specified and directed. Note :- 4x 10 Sq mm conductor cable, 1 x 10 Sq mm conductor earth continuity cable & PVC conduit shall be measured as one unit length)
S&F call bell ding dong sound type suitable for AC 230 volt single pole complete all as specified and directed.
S&F switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified and directed.
S&F switch piano flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified and directed.
S&F socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified and directed.
S&F Switch socket combination 5 in 1, 5 pin 5/6 Amps flush type universal of polycabonate body complete all as specified and directed.
S&F Switch socket combination 5 in 1, 5 pin 6/16 Amps flush type universal of polycabonate body complete all as specified and directed.
S &F Lamp holder, PVC/ polycarbonate type with back plate for angle holder complete all as specified and directed.
S&F Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. ISI marked complete all as specified and directed.
S&F in replacement of modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and directed.
S&F in replacement of modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and directed.
S&F in replacement of modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and directed.
S&F in replacement of modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and directed.
S&F in replacement modular bell push switch piano, flush type, 6 Amps complete all as specified and directed.
S&F in replacement switch piano type switch two way AC 230 volts 6 Amps as per on existing switch board complete all as specified and directed.
S&F in replacement modular fan regulator, 2 Module 4 step 180 W heavy duty 230 volts as per existing model/make complete all as specified and directed.
S&F in replacement of 3mm thick Hylam sheet of required size of main switch board, same board, power socket board etc as per site requirement, including brass screws, washers etc and cutting groove to accommodate switch, socket, regulator etc complete all as specified and directed.
S&F PVC rectangular block of size 200 x150 x50mm for mounting switches,sockets/fan Reg,etcwith 3mm thick plastic laminated sheet cover complete all as specified and directed.
S&F in replacement of two core wire 1.5 Sqmm multi-stranded PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
S&F in replacement of PVC insulated, unsheathed twin twisted copper conductor wire of nominal size 23/0.0076, 1100 volt grade, ISI marked, complete all as specified and directed.
Taking down old unserviceable DBs/Main switches any type/size complete with all accessories and removal from site complete all as specified and directed.
S&F Sheet metal enclosure for DBs when MCBs to be Used, 4 way, TP & N, double door type, 440 Volt, suitable for MCB/MCCBs incomer complete all as specified and directed. Note : MCBs/MCCBs shall be measured and paid separately
S&F sheet metal enclosure for DBs when MCBs to be Used, 8 way, SP & N, double door type, 240 Volt complete all as specified and directed. Note : MCBs shall be measured and paid separately.
S&F Sheet metal enclosure for DBs when MCBs to be Used, 4 way, SP & N, double door type, 240 Volt complete all as specified and directed. Note : MCBs shall be measured and paid separately.
S&F MCCB, four pole, 125 Amp, 415 Volt, of breaking capacity 16 KA complete all as specified and directed.
S&F 415V 10KA 'C' curve miniature circuit breaker (MCB), TPN, 63 Amps current carrying capacity in the DB complete with connection, testing and commissioning complete all as specified and directed.
S&F 240V 10KA 'C' curve miniature circuit breaker (MCB), SPN, 40 Amps current carrying capacity in the DB complete with connection, testing and commissioning complete all as specified and directed.
S&F 240V 10KA 'C' curve miniature circuit breaker (MCB), SP, 6-32 Amps current carrying capacity in the DB complete with connection, testing and commissioning complete all as specified and directed.
S&F repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified and directed.
Supply only PVC insulation tape of width 18 mm, thickness 0.125 mm in length of 6 mtr, ISI marked complete all as specified and directed.
S&F in repair rigid non metallic, heavy duty, PVC casing caping of size 32 x 16 mm with all accessaries such as couplers, lock nuts, saddles, hook, tees, bends, etc complete all as specified and directed.
S&F in repair of Smart bright Batten Series, LED luminaire using LEDs 20/22 watt min100 LM/ watt, natural white(4000K)/ cool white (6500k), THD max 10 % ,CRI min 80 % with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322 (Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification complete all as specified and directed.
S&F in repairs LED Mirror light fitting 2 ft tube light 10 watt aluminum housing and integrated electronic driver THD max 10 % ,CRI min 80 % complete with fixing arrangements on wall complete all as specified and directed.
S&F repairs LED light fitting square 2'x2' 35/36 watt, 3000 lumen, Cool white 6500K/ Warm white 5700K, all as per direction, THD max 10 % ,CRI min 80 % warm white along with fixture Surface / Recessed /Pendent mounting LED luminaries with diffuser channel Luminaires ers, connector block, etc complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed.
S&F repair LED light down lighter by recess or surface mounted 15 watt, warm white, circular/Square, 1200 lumen with fixing arrangemnts on ceiling complete all as specified and directed.
S&F replacement of LED Security Light Luminaire 35 watt with 2500 or more lumen warm white, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole/wall fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint complete all as specified and directed.
S&F repairs LED Bulb 230V AC 9/10 watt warm white or yellow/cool day light 6500K as per the direction/requirement of site complete all as specified and directed.
Taking down carefully ceiling fan/exhaust fan any type, size or make with cable and all accessoreis remove from site to store for repair/overhaulling complete all as specified and directed.
Overhauling of Ceiling fan 1200/1400 mm sweep by opening and cleaning rotor, bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and connecting on its existing position and testing on completion complete all as specified and directed. Note : Items required to be replaced & rewinding of fan motor if required will be measured and paid separately in relevent items.
Dismantling of Ceiling fan 1200/1400 mm sweep along with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding, ball bearing, gun metal bush etc complete to carry out the fwg repairs complete all as specified and directed :- (a) Removing of burnt out fan winding and rewinding it with suitable size of Copper enamelled wire (weight of copper coil shall be same as per dismantled fan), heating and varnishing as per manufactures design & direction. (b) Re-assembling the ceiling fan by fixing only serviceable spare parts complete to give designed air delivery including greasing, oiling etc, reconnecting / hanging in original position, reconnecting the electric cables and testing complete, all as directed.
M&L painting of ceiling fans (1200 mm/ 1400 mm) complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts including writing of MES Nos in black paint complete all as specified and directed.
Overhauling of exhaust fan 250 mm to 300 mm sweep (steel body/pvc body) after opening and cleaning rotor, bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and connecting on its existing position and testing on completion complete all as specified and directed. Note : Items required to be replaced & rewinding of fan motor if required will be measured and paid separately in relevent items.
Dismantling of exhaust fan 250/300 mm sweep, unscrewing the body parts, taking out starter, rotor winding, ball bearing, gun metal bush etc.,removing of burnt out fan winding and rewinding it with suitable size of Copper enamelled wire (weight of copper coil shall be same as per dismantled fan), heating and varnishing as per manufactures design & direction, re-assembling the fan by fixing only serviceable spare parts complete to give designed air delivery including greasing, oiling etc, refixing the same in original position, reconnecting the electric cables and testing complete all as specified and directed.
S&F replacement of louvers shutters any type complete with nuts, bolts and washers suitable for exhaust fans of size above 250 mm and up to 450 mm sweep complete all as specified and directed.
M&L making hole on masonary wall/ Wooden Panel of size suitable for exhaust fan complete incl finishing and making good as per existing complete all as specified and directed.
S&F in repairs fan condensor 2.5 to 3.15 MFD, 230 volts, 50 Hz AC confirming to IS 1709 complete all as specified and directed.
S&F in repairs fan condensor 4 MFD, 230 volts, 50 Hz AC confirming to IS 1709 complete all as specified and directed.
S&F in repairs Gun metal bush 15 mm size as per sample complete all as specified and directed.
S&F in repairs split pin of size 25 mm long complete all as specified and directed. .
S&F repairs Ball bearing of size 6201/6202/6203 as per sample complete all as specified and directed.
S&F repairs MS down rod suitable for ceiling fans of any type and size 'medium grade' 15mm dia complete with making split holes, cut or threads at both end of pipe as required for hanging of ceiling fan incl.painting of rod with two coats of synthetic enamel white paint over one coat of primer complete all as specified and directed.
S&F repairs MS Anti Suicide Fan Rod (smart Fan rod) of standard size (12/18 inch) and grade ISI marked, having bearable weight 20-22 Kg, heavy duty, 15mm dia complete required for hanging of ceiling fan complete all as specified and directed.
S&F repairs 'U' shape shackle clamp assembly incl. checknut, bolts, screws, washer, lock nut, rubber reel etc.and connecting complete all as specified and directed.
S&F repairs fan hook made out of steel bar as per sample complete all as specified and directed.
S&F repairs of Unserviceable fan blade suitable for ceiling fan of any type / size as per sample complete all as specified and directed.
S&F replacement of Unserviceable fan blade suitable for exhaust fan of any type / size as per sample complete all as specified and directed.
Repair/ maintenance and sevicing of non functioning geysers of capacity upto 50 ltrs due to any defect like air lock, water leakage in pipe line joints, non functioning of any parts, checking electric connections and making good the loose electric connection and pipe line leakage etc.and making the geysers functional complete all as specified and directed.
Taking down carefully storage type water heaters (Geyser) of any type and make of capacity upto 50 ltrs for servicing after disconnecting their electrical and water connections. De-scaling the inner container, heating element, base assembly using diluted hydrochloric acid and cleaning thoroughly. Filling the inner container with water and detecting leakage including brazing as required to stop the leakage, if any, reassembling the geysers after replacing the u/s spare parts, filling water and testing the geysers by applying pressure by means of hand/foot operated pump, to ensure leak proof. Refixing geyser in the same original position/location and making the electrical/water supply connections incl testing on completion complete all as specified and directed. Note (a) Items required to be replaced will be measured and paid separately under relevent items of the Schedule (b) The rate for fixing of new spare parts are deemed to be included in quoted unit rate of above items)
S&F repairs geyser elements I.5 KW as per existing pattern fitted in the geyser complete all as specified and directed.
All as per item No 158 above but 2.0 KW complete all as specified and directed.
S&F repairs Thermostat suitable for any make & type of Geyser 25/35/50 ltr capacity complete all as specified and directed.
S&F repairs PVC connection 15 mm size with PTMT nuts of length 450 mm as inlet for cold water including taking down the old unserviceable PVC connection pipe complete all as specified and directed.
S&F in repairs PVC connection 15 mm size, spirally reinforced with stainless steel wire inside the pipe for outlet hot water pipe connection, with brass nuts at both ends of length 450 mm including taking down the old unserviceable PVC pipe complete all as specified and directed.
S&F in replacement of 3 core multi stranded copper conductor PVC insulated cable 2.5 Sqmm1100 volts grade complete all as specified and directed.
S&F in repairs 3 pin plug top 15 Amps, 240 volts including taking down old unserviceble 3 pin plug top 15 amps complete all as specified and directed.
S&F in repairs 3 pin plug top 05 Amps, 240 volts including taking down old unserviceble 3 pin plug top 05 amps complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical and testing for required value complete all as directed by Engineer-in-charge
NOTES :- 1.The time limit for attending the complaints on intimation to the contractor by the department shall be as under:- (a) Rewinding of fan motors - within 7 days (b) Other Misc jobs- within 1 day 2. In case the contractor fails to attend/rectify the defects within the above time limit, penalty will the imposed as Rs 1000/- per day in case of complaints/jobs mentioned at note 1 (a) & (b) above. 3. The contractor or his authorised representative shall report to concered JE or the Engineer-in-charge at 0900 hours daily on all working days to receive order/instructions of the work or regular complaints. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative, Users and the Engineer-in -Charge / JE Concered.
Schedule of credit amount of Rs. 139957.25 to be deducted during AOC.
SRI SAI CONSTRUCTION COMPANY (BID ID -3339313)
titiksha india (BID ID -3344638)
MAA SHARDA CONSTRUCTION (BID ID -3338988)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .