Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.7 L+₹7,212 (1.97%)Rejected-Finance | L2 | Rejected-Finance Not Admitted |
Tender Value
Refer Docs
EMD Value
₹7,500
Closing Date
21 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE Indpt Pachmarhi
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
REPAIR/MAINT OF COOLING APPLIANCES WITH ALLIED WORKS AT AEC TRG COLLEGE AND CENTRE PACHMARHI
2022_MES_515343_1
CA No. AGE(I)/PACH/ of 2022-23(8466/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
Pachmarhi MP
Class E category b(i)
8 documents required · 8 mandatory
₹300
AGE Indpt Pachmarhi
₹7,500
Yes
9 Jun 2022
25 Mar 2022
23 Apr 2022
25 Mar 2022
21 Apr 2022
8 Apr 2022
180 days
Amount
Material and labour for disconnecting electric connection, taking down/ keep aside the air conditioner (Split/Window)/Water Cooler/Refrigerator/Deep Freezer including stabilizer of any make and capacity,servicing the same as cleaning inside, by mean of cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gaskit and tightening of loose wiring, loose connection, replacement of wornout, nutbolt, washers, gaskits etc and necessary cutting, welding/ soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and made functional the equipment fully and Re-installation in position and testing complete all as specified and directed by Engineer-in-charge. Note: (All new spare parts will be measured and paid separately under the respective items.)
M&L for detection and rectification of leakages in gas line by necessary brazing in 1.5 Ton/2.0 Ton window / split type AC/refridgerartor/deep freezer/water cooler of any model and any make and ensuring the complete systems leak proof including checking the system and replacement of required spare parts including charging of refrigerant gas R-134A / R 22 or any other refridgerant gas as required with appropriate quantity including testing for smooth functioning all as specified and directed. Note: Spare parts, if requited will be measured and paid separately under the supply of respective items.
M& L for Dismantling of unserviceable/worn hermetically sealed unit compressor from window /Split type AC and replacement with new one compressor (company repaired), suitable for existing same model/make of capacity 1.5/2 TR split/window type AC including brazing with suction and discharge line, checking the system for leak proof and inclduing charging of refrigerant gas R-134 A /R 22 in appropriate qty after making vacume the complete system and testing the A/C for proper functioning all as directed. .
Supply and fixing the following items required in repairs of equipments mentioned against item No 1 here in above including dismantling, opening the equipments, assembling and testing complete all as specified and directed by Engineer-in-charge. Note : All the repairs shall ensured to be carried out at AGE (I) store yard including transportation of equipment and re-fixing at site.
(a) Cooling coil complete with fins made of copper suitable upto 2Ton/1.5 Ton capacity Window/Split type AC as per existing size and specification
(b) Condensing coil coplete with fins made of copper suitable upto 2Ton/1.5 Ton capacity Window/Split type AC as per existing size and specification
(c) Fan motor for water cooler upto 150 Ltr capacity.
(f) Fan blade suitable for AC's blower/ water cooler motor and all as per sample.
(g) Condensing coil suitable for water cooler upto 150 Ltr capacity copper as per existing make and model.
(h) Cooling coil suitable for water cooler upto 150 Ltr capacity copper madeas per existing make and model.
(i) Water outlet tap made of brass cromium plated for water cooler.
(k) Liquid line valves copper made for ACs upto 2Ton capacity.
(l) Refrigerant line valve copper made suitable for ACs upto 2Ton capacity.
(m) Foam insulation heavy duty for ACs refrigerant line.
(n) Capilary tube for water cooler/ refrigerator/AC all as per exiting size.
S & F Starting/Running capacitor 80/100 mfd + / - 400 V AC, Suitable for 1.5/2.0 TR window / split type AC including taking down unserviceable old one
S & F Over load Relay including taking down unserviceable old one.
S & F Thermostat switch ( DT 50-1052), suitable for 1.5 Ton/2 Ton split / window type AC including taking down unserviceable old one .
S & F Blower/Propeller fan motor Single Phase 230 V AC, 50 Hz as per existing sample for indoor unit including taking down unserviceable old one
S & F Blower/Propeller fan motor Single Phase 230 V AC, 50 Hz as per existing sample for outdoor unit including taking down unserviceable old one
S & F Stainer/Filter (copper) Suitable for window type AC of 1.5/2.0 TR cooling capacity including taking out the old one.
Supply and Fixing Electronic Circuit plate (PCB) for Split/Window A/C 1.5 TR/2 TR including taking down unserviceable old one .
Taking out the unserviceable sealed compressor unit from water cooler and S&F New Sealed compressor unit company repaired of existing sample, suitable for 40/80 Ltr capacity of water cooler. replace with New compressor (duly tested)and checking the complete system for leak proof and including charging of refrigerant gas R-134 a in appropriate quantity and testing for smooth functioning complete all as directed.
Supply and fixing Running capacitor for Water Cooler having capacity 40/80 and 150Ltr as per existing sample including taking down unserviceable old one
Supply and fixing over load Relay for Water Cooler having capacity 40/80 and 150Ltr including taking down old one
Supply and fixing Float valve of 15mm dia non-metallic for Water Cooler having capacity 40/80 and 150Ltr including taking down old one
Supply and fixing PVC connection of size 15mm dia for Water Cooler having capacity 40/80 and 150Ltrincluding taking down unserviceable old one
M& L for replacement of relay, suitable for 300/310 Ltr refrigerator of any make/model including taking down unserviceable old one
Labour work for collecting split type/ Window type AC of 1.5 TR / 2 TR cooling capacity of any make/model from existing location /E/M store yard including installation of indoor and outdoor unit where as directed, making/breaking hole through the wall for and passing the suction/discharge line and PVC coduit of 25 mm dia n.exc.3.5 mtr long in concealed surface of wall for drainage of water occurs due to humidity, making good to disturbed surfaces with cement mortor of ratio1:3 finishing to match existing same and testing complete all as directed.
S&F wall mounted type stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 170Vto 285V and with output voltage stabilizer at 230V with accuracy of +/-2.5%and capacity of 05 KVA complete and taking out old all as specified and directed. Make- V-Gaurd,AE,Sinetrac
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed including taking down old one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
S&F MCB’s single pole, 10 KA ,6 Amp to 30 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs etc including taking down old one complete all as directed. Make:SHEINEDER/LEGRAND /L & T/C & S/HAVELLS
S&F MCB’s single pole and neutal, 10 KA ,32 Amp to 40 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs including taking down old one complete all as directed. Make:SHEINEDER/LEGRAND /L & T/C & S/HAVELLS
S&F Sheet metal enclosure with socket plug top and MCBs single pole with a two pin and earth plug and socket complete with one singlle pole MCB of "C" series of cap 16-32 Amp including taking out the old one all as specified and directed Make - Legrand / C&S/ Havells/Anchor
M&L Metal clad Industrial plug top ISI mark 2 pin with earth 250 Volts including taking down old one complete as specified and directed. Make – Havels, Legrand, HPL
M&L Metal clad Industrial socket ISI mark with earth 250 Volts including taking down old one complete as specified and directed. Make – Havels, Legrand, HPL
M & L PVC insulated copper cable 3 core 40/ 0.0076, AC 1100/660 volt including taking down U/S cable.
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 230 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces as per existing including taking down the old one complete all as specified and directed .
GHASI RAM SAHU
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .