| 3 | L3₹1.2 L+₹2,950 (2.56%)Admitted-Finance 1170 VAISHALI TAILORS J M ROAD SHIVAJI NAGAR PUNE 411 005 | PUNE | PUNE | MAHARASHTRA | 411005 | L3 | Admitted-Finance | |
| 4 | L4₹1.4 L+₹26,550 (23.1%)Admitted-Finance | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | surya systems L4 | SHIVSAGAR ELECTRICALS L2 | Rupesh Trading Company L1 | Imprint Digitech L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | JOB WORK : REPAIR/MAINT OF 1000 KVA TRANSFORMER HT BUSHING, DEHYDRATION & TOP UP OF TRANSFORMER OIL, CABLE JOINT AT 512 ABW MRS UNDER AOR OF UNDER AOR OF AGE E/M-II OF GE (C ) KHADKI
(a) M&L for disconnecting HT XLPE cable of any size from transformer for finding fault, defect rectification HT cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including taking out defective cable from ground and additional excavation in normal or any type of strata required for exposing the cable fault. Removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work all as specified and as directed by Engr-in-Charge at site.- 01 Each Job.
(b) M&L in repairs HT heat shrinkable indoor type end termination cable jointing kit suitable for 22 KV, 3 core 95 Sqmm XLPE aluminium conductor cable including disconnecting of cable and removing of old jointing kit complete all as specified and as directed. - 01 Each Job.
(c) M & L for Dehydration incl filtration and cleaning of 1000 KVA transformer oil by dehydrating machine incl testing before and after of sample at 2.5 mm gap to achieve suitable break down voltage limit minimum 50 KV after dehydration and filtration all as specified and directed . Note: (i) Contractor to arrange the dehydration machine, testing kit and make arrangement for electric supply without any extra cost. 01 Each Job. | 1 | JOB | 1,20,000 ₹1,41,600 | 99,900 ₹1,17,882 | 97,500 ₹1,15,050 Lowest | 1,00,000 ₹1,18,000 |
| 2.00(d) M&L for New Filling / top up transformer oil as per IS: 335 of low viscosity having dielectric strength not less than 60 KV, all as specified and as directed. Note: Dielectric strength test should be carried out at site before poring/filling in transformers in the as directed by Engr-in-Charge.- 150 Ltrs. (e) Supply and fixing HT bushing with brass spindle nut bolt washers etc for 1000 KVA transformer as per existing size and shape including reactification of transformer oil leakage complete all as directed by Engr-in-Charge - Each Set - 01. (f) M&L labour for epoxy painting of transformer HT side bushing box surrounding inside area and repair of damage sheet with welding and required GI sheet complete all as directed by Engr-in-Charge. Each job - 01 . (g) M&L for carrying out magnetic balance test of existing distribution transformer of 22 KV/ 433 Volt capacity, including isolation of transformer from HT and LT supply, disconnection of cables, testing of three phases (R, Y & B) by applying suitable single phase AC Voltage at HT terminals and measuring the included voltages in the respective phases, recording and analysing the test results to ascertain the condition of transformer core and windings. The test shall be carried out by using a calibrated digital voltmeter and suitable testing all connection shall be restored to their original position and transformer shall be made ready for normal operation, complete as directed by Engr-in-Charge. Each Job - 01. | |||||||
| 3.00Note: 1. Old retrieved materials will be contractor’s property; hence, sch of credit Rs 380.00 already deducted in the rate analysis. 2. GST % amount to be shown separately. | |||||||
Tender Value
Refer Docs
Closing Date
21 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KHADKI
GE Central Khadki
REPAIR MAINT OF 1000 KVA TRANSFORMER HT BUSHING DEHYDRATION and TOP UP OF TRANSFORMER OIL CABLE JOINT AT 512 ABW MRS UNDER AOR OF UNDER AOR OF AGE EM II OF GE C KHADKI
2026_MES_798817_1
3008/E-Qtn/17/E3
Limited
Job Works
Works
30 days
GE Central Khadki
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
23 Nov 2026
14 Nov 2026
23 Nov 2026
14 Nov 2026
21 Nov 2026
14 Nov 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | JOB WORK : REPAIR/MAINT OF 1000 KVA TRANSFORMER HT BUSHING, DEHYDRATION & TOP UP OF TRANSFORMER OIL, CABLE JOINT AT 512 ABW MRS UNDER AOR OF UNDER AOR OF AGE E/M-II OF GE (C ) KHADKI
(a) M&L for disconnecting HT XLPE cable of any size from transformer for finding fault, defect rectification HT cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including taking out defective cable from ground and additional excavation in normal or any type of strata required for exposing the cable fault. Removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work all as specified and as directed by Engr-in-Charge at site.- 01 Each Job.
(b) M&L in repairs HT heat shrinkable indoor type end termination cable jointing kit suitable for 22 KV, 3 core 95 Sqmm XLPE aluminium conductor cable including disconnecting of cable and removing of old jointing kit complete all as specified and as directed. - 01 Each Job.
(c) M & L for Dehydration incl filtration and cleaning of 1000 KVA transformer oil by dehydrating machine incl testing before and after of sample at 2.5 mm gap to achieve suitable break down voltage limit minimum 50 KV after dehydration and filtration all as specified and directed . Note: (i) Contractor to arrange the dehydration machine, testing kit and make arrangement for electric supply without any extra cost. 01 Each Job. | 1 | JOB | - | - |
| 2 | (d) M&L for New Filling / top up transformer oil as per IS: 335 of low viscosity having dielectric strength not less than 60 KV, all as specified and as directed. Note: Dielectric strength test should be carried out at site before poring/filling in transformers in the as directed by Engr-in-Charge.- 150 Ltrs.
(e) Supply and fixing HT bushing with brass spindle nut bolt washers etc for 1000 KVA transformer as per existing size and shape including reactification of transformer oil leakage complete all as directed by Engr-in-Charge - Each Set - 01.
(f) M&L labour for epoxy painting of transformer HT side bushing box surrounding inside area and repair of damage sheet with welding and required GI sheet complete all as directed by Engr-in-Charge. Each job - 01 .
(g) M&L for carrying out magnetic balance test of existing distribution transformer of 22 KV/ 433 Volt capacity, including isolation of transformer from HT and LT supply, disconnection of cables, testing of three phases (R, Y & B) by applying suitable single phase AC Voltage at HT terminals and measuring the included voltages in the respective phases, recording and analysing the test results to ascertain the condition of transformer core and windings. The test shall be carried out by using a calibrated digital voltmeter and suitable testing all connection shall be restored to their original position and transformer shall be made ready for normal operation, complete as directed by Engr-in-Charge. Each Job - 01. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
BOQ_896159.xls
BOQ • 0.28 MB
Appendix_A.pdf
Additional Documents • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .