| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAdmitted-Finance 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Admitted-Finance | |
| 2 | L2₹10.8 L+₹27,080 (2.58%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹10.8 L+₹33,198 (3.16%)Admitted-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L3 | Admitted-Finance | |
| 4 | L4₹10.9 L+₹38,918 (3.70%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | Rejected-Technical B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | - | Rejected-Technical Not admitted |
| Sl No | Description | Qty | Unit | neeraj electricals L1 | City buildcom builders & devlopers L4 | PRAGATI ELECTRICALS AND ELECTRONICS L3 | PRADEEP TIWARI CONTRACTOR L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking out old copper cable and S&F in Copper cable of size 25 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit of including taking out old cable, complete all as specified and directed.Make-Havells/Polycab/L&T | 145 | RM | 400 ₹58,000 | 360 ₹52,200 | 300 ₹43,500 | 270 ₹39,150 Lowest |
| 2.00 | Taking out old copper cable and S&F in Copper cable of size 35 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed.Make-Havells/Polycab/L&T | 75 | RM | 520 ₹39,000 | 450 ₹33,750 | 500 ₹37,500 | 400 ₹30,000 Lowest |
| 3.00 | Taking out old copper cable and S&F in Copper cable of size 50 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed.Make-Havells/Polycab/L&T | 120 | RM | 600 ₹72,000 | 500 ₹60,000 Lowest | 700 ₹84,000 | 500 ₹60,000 Lowest |
| 4.00 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 63 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Make : Siemens/Legrand/L&T. | 2 | Each | 5,000 ₹10,000 | 3,000 ₹6,000 | 2,500 ₹5,000 | 2,200 ₹4,400 Lowest |
| 5.00 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 100 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Make : Siemens/Legrand/L&T. | 3 | Each | 7,000 ₹21,000 | 8,500 ₹25,500 | 5,000 ₹15,000 Lowest | 6,000 ₹18,000 |
| 6.00 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 250 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Make : Siemens/Legrand/L&T. | 3 | Each | 14,000 ₹42,000 | 10,000 ₹30,000 | 8,000 ₹24,000 Lowest | 8,000 ₹24,000 Lowest |
| 7.00 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 400 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Make : Siemens/Legrand/L&T. | 2 | Each | 20,000 ₹40,000 | 14,000 ₹28,000 Lowest | 15,000 ₹30,000 | 15,500 ₹31,000 |
| 8.00 | Taking out old contractor & S&F in replacement power contactor, type ML-4, 3 pole, 415V, 50Hz, 3 Phase, with auxilary contacts 2 NL&T (Cat No -SS90910) L&T /Legrand/ Seimens/ Schinider as approved by GE] | 3 | Each | 8,400 ₹25,200 | 10,000 ₹30,000 | 8,000 ₹24,000 Lowest | 8,000 ₹24,000 Lowest |
| 9.00 | Taking out old contractor & S&F in replacement power contactor, type ML-6, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete all as specified and directed.[Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE] | 3 | Each | 9,500 ₹28,500 Lowest | 15,000 ₹45,000 | 12,000 ₹36,000 | 13,500 ₹40,500 |
| 10.00 | Taking out old contractor & S&F in replacement power contactor, type ML-2, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete including taking out all as specified and directed.[Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE] | 3 | Each | 4,500 ₹13,500 Lowest | 7,000 ₹21,000 | 6,000 ₹18,000 | 6,000 ₹18,000 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
18 Jul 2026, 6:00 pmClosed
SHRI ANKIT GOYAL, IDSE
Garrison Engineer Dronachal
REPAIR/ MAINT AND IMPROVEMENT OF WATER SUPPLY, SEWAGE PUMP REPAIR UNDER GE DRONACHAL
2026_MES_773565_1
8109/E8
Open Tender
Civil Works
Item Rate
180 days
BHOPAL
Class-E, Category a (ii) and as per NIT documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Dronachal
₹30,000
Yes
28 Jul 2026
20 Jun 2026
20 Jul 2026
20 Jun 2026
18 Jul 2026
4 Jul 2026
20 Jun 2026 - 27 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out old copper cable and S&F in Copper cable of size 25 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit of including taking out old cable, complete all as specified and directed.Make-Havells/Polycab/L&T | 145 | RM | - | - |
| 2 | Taking out old copper cable and S&F in Copper cable of size 35 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed.Make-Havells/Polycab/L&T | 75 | RM | - | - |
| 3 | Taking out old copper cable and S&F in Copper cable of size 50 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed.Make-Havells/Polycab/L&T | 120 | RM | - | - |
| 4 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 63 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Make : Siemens/Legrand/L&T. | 2 | Each | - | - |
| 5 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 100 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Make : Siemens/Legrand/L&T. | 3 | Each | - | - |
| 6 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 250 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Make : Siemens/Legrand/L&T. | 3 | Each | - | - |
| 7 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 400 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Make : Siemens/Legrand/L&T. | 2 | Each | - | - |
| 8 | Taking out old contractor & S&F in replacement power contactor, type ML-4, 3 pole, 415V, 50Hz, 3 Phase, with auxilary contacts 2 NL&T (Cat No -SS90910) L&T /Legrand/ Seimens/ Schinider as approved by GE] | 3 | Each | - | - |
| 9 | Taking out old contractor & S&F in replacement power contactor, type ML-6, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete all as specified and directed.[Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE] | 3 | Each | - | - |
| 10 | Taking out old contractor & S&F in replacement power contactor, type ML-2, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete including taking out all as specified and directed.[Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE] | 3 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
PS_8109.pdf
Tender Documents • 0.28 MB
SOC_8109.pdf
Tender Documents • 0.20 MB
GPSC_8109.pdf
Tender Documents • 0.60 MB
BOQ_866175.xls
BOQ • 2.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .