Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC GOSWAMI COLONY PO UDAYAN VIHAR DISTT KAMRUP ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.4 L+₹2.6 L (12.5%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.5 L+₹3.7 L (17.7%)Rejected-Finance OIL INDIA LTD GATE NO 02 PO UDAYAN VIHAR GUWAHATI ASSAM | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹26.7 L+₹5.9 L (28.1%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
20 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR/MAINT TO WATER SUPPLY INSTALLATION INCLUDING CLEANING OF OH/UG RESERVOIR AND ALLIED WORKS AT OTHER THAN BASISTHA AREA UNDER GE GUWAHATI
2023_MES_580216_1
GE/GUW/80/8254 OF 2022-23
Open Tender
Civil Works
Works
150 days
GUWAHATI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE GUWAHATI
₹50,000
Yes
27 Apr 2023
10 Feb 2023
22 Mar 2023
10 Feb 2023
20 Mar 2023
24 Feb 2023
10 Feb 2023 - 17 Feb 2023
Amount
Opening man hole cover of filter plant and taking out care fully all old filter media and PVC strainer from filter shell, removing unserviceable materials to a safer distance n.exc 50 m and cleaning the filter bed thoroughly with clean water to remove all dirt, scale, mud etc including strainer, pipe line complete for 5000 GPH capacity filter plant and replace the unseviceable filter media as required complete all as specified and as directed. Note:- New filter media shall be measured and paid separately under subsequent items.
Opening man hole cover of filter plant and taking out care fully all old filter media and PVC strainer from filter shell, removing unserviceable materials to a safer distance n.exc 50 m and cleaning the filter bed thoroughly with clean water to remove all dirt, scale, mud etc including strainer, pipe line complete for 8000 GPH capacity filter plant and replace the unseviceable filter media as required complete all as specified and as directed. Note:- New filter media shall be measured and paid separately under subsequent items.
Supply and fixing new life Manganese Di-Oxide (Mno2) compound of size 1x1/2 inch filled in layers as specified and directed.
Supply and filling iron removal chemical Anthracite/ carbofilt coal for 8000/5000 GPH capacity filter plant complete all as specified and directed
Supply and fixing gravels of size 20x12mm filled in layers as specified and directed for 5000/8000 GPH capacity filter plant.
Supply and fixing gravels of size 12x6mm filled in layers as specified and directed for 5000/8000 GPH capacity filter plant.
Supply and fixing gravels of size 6x3mm filled in layers as specified and directed for 5000/8000 GPH capacity filter plant.
Supply and fixing gravels of size 3x1.5mm filled in layers as specified and directed for 5000/8000 GPH capacity filter plant.
Supply and fixing 10-32mesh fine sand filled in layers as specified and directed for 5000/8000 GPH capacity filter plant.
Supply and fixing in repair, 80mm bore, cast iron butter fly valve complete all as specified and directed
Supply and fixing in repair, 100mm bore, cast iron butter fly valve complete all as specified and directed
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 15cm and n exc 22.5cm long 16 to 20mm dia of shank complete all as specified & as directed.
Supply and fixing in repair gasket 300mm size complete all as specified and directed
S&F Galvanised iron (GI) pipe with all fittings,80 mm bore(medium grade) laid in trenches, fixed on wall/floor including taking out old unserviceable pipe of any description complete all as specified and as directed.
S&F Galvanised iron (GI) pipe with all fittings,100 mm bore(medium grade) laid in trenches, fixed on wall/floor including taking out old unserviceable pipe of any description complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for taking out / laying pipes etc. and getting out, in soft/loose soil, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/loose soil, complete all as specified and as directed.
Removing excavated material, soils, n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
S&F FRP construction, solution preparations cum settling tank, capacity 100 ltrs with level gauge, lid, inlet / outlet connection, drain connection and fitted with speed reducer, motor and SS agitator including replacing the old unserviceable one, complete all as specified and directed.
S&F in repair, chemical dosing (metering) pump, 6ltrs/hr @ 10 kg back pressure, electromagnetic type with suction & discharge tubing, spring loaded anti siphon valve, foot valve etc complete all as specified and directed.
S&F in repair, Cast Iron Alum/ Soda pot (each having 14 Ltr) complete all as specified and directed.
S&F in repair, 6 Sqmm, 3 core, 1100 volts grade, flat cables with copper conductor insulated and sheathed with XLPE for submersible pump motors complete all as specified and directed.
Supply and laying in replacement, Syntheic Rubber insulated Mat of size 2mtrs x 1mtrs, 2mm thick suitable for voltage upto 3.3KV for electrical purpose as per IS 1562-2006(Superseding IS 5424) for electrical shock safety complete all as specified and directed.
S&F submersible safety wire, PVC Coated high carbon steel 7*19 wire, 6mm dia, breaking capacity 2.5Qtl suitable for hanging submersible pump set upto 15HP complete all as specified and directed.
Cleaning (inside tank only) of PS Over Head Tank of capacity 9600 Gallons, 15 mtr staging height, using following stages cleaning process including arrangement of necessary T&P, labour and Chemicals mechanize etc before starting process of cleaning complete all as specified and as directed:- (a) Mechanized Dewatering (b) Sludge Removal (c) High Pressure Cleaning (d) Vaccum cleaning (e) Antibacterial spray (f) UV radiation. (g) Painting two coats of black bituminous paint on internal surface of Over Head water reservoir after cleaning the tank. Note:- (i) The entire work shall be carried out by well experienced personal/firms having experience of similar nature of work. (ii) Entire T&P and all Safty measure during the work shall be arranged by the contractor at his own cost. (iii) "Date of cleaning" shall be written over the outer surface at appropriate level to be decided by Engineer-in-charge with synthetic enamel paint of letteres not less than 100mm height and the cost of the same shall be deemed to include in the quoted unit rate of the contractor.
Cleaning (inside tank only) of RCC Over Head Tank of capacity 25000 Gallons, 18 mtr staging height, using following stages cleaning process including arrangement of necessary T&P, labour and Chemicals mechanize etc before starting process of cleaning complete all as specified and as directed:- (a) Mechanized Dewatering (b) Sludge Removal (c) High Pressure Cleaning (d) Vaccum cleaning (e) Antibacterial spray (f) UV radiation. (g) Painting two coats of black bituminous paint on internal surface of Over Head water reservoir after cleaning the tank. Note:- (i) The entire work shall be carried out by well experienced personal/firms having experience of similar nature of work. (ii) Entire T&P and all Safty measure during the work shall be arranged by the contractor at his own cost. (iii) "Date of cleaning" shall be written over the outer surface at appropriate level to be decided by Engineer-in-charge with synthetic enamel paint of letteres not less than 100mm height and the cost of the same shall be deemed to include in the quoted unit rate of the contractor.
S&F in repair CI sluice valve of size 100 mm bore with brass spindle and cast iron hand wheel head & brass spindle complying with IS:14846-2000, class PN 1.6 both ends flanged complete with rubber/fibre board insertion gasket joints, nuts, bolts & washers of required size & Nos complete all as specified and as directed.
S&F in repair CI sluice valve of size 80 mm bore with brass spindle and cast iron hand wheel head & brass spindle complying with IS:14846-2000, class PN 1.6 both ends flanged complete with rubber/fibre board insertion gasket joints, nuts, bolts & washers of required size & Nos complete all as specified and as directed.
S&F in repair CI Reflux/ Non Return valve single door pattern with flanged ends PN-1.6 confirming to IS: 5312, ISI marked of size 100mm dia bore with bypass arrange ment including all fixing accessoriestype Cast iron flanged end with nuts, rubber gasket, bolts (full threaded), nuts & washers complete all as specified and as directed.
S&F in repair CI Reflux/ Non Return valve single door pattern with flanged ends PN-1.6 confirming to IS: 5312, ISI marked of size 80mm dia bore with bypass arrange ment including all fixing accessoriestype Cast iron flanged end with nuts, rubber gasket, bolts (full threaded), nuts & washers complete all as specified and as directed.
Taking out monoblock type pump (Make-Kirlosker) of 15 HP capicity from its foundation duly disconnecting suction and delivery lines, transporting to autharised civil workshop, dismantalling, opening and sort out diffective spares and parts and cleaning, servicing, greasing and replacememt of deffective spares including painting of pump with two coats of synthetic anamel paint as per existing colour after and including prepration of old painted surface of pump set and transporting back the to site after repair, refixing, mounting the base to its original foundation, testing and commissioning complete all as directed. Note:- New spares as required shall be measured and paid separately under items as 'Supply only' here in after.
Supply only Casing bearing suitable for centrifugal type monoblock pump 15 HP pump set
Supply only Impeller suitable for centrifugal type monoblock pump of capacity 15HP
Supply only Bushing suitable for centrifugal type monoblock pump of capacity 15HP.
Taking out the existing submersible pump set (Make-Calma/KSB) of capacity 10 HP duly disconnecting all electrical and mechanical connections complete with column pipe with the help of chain pully block & tripod etc from the max depth of 360 feet, transporting the same to civil authorised workshop and bring back to site after repair and replacement of defective spares for pump, rewinding the motor with super enamelled copper winding wires of suitable gauge and size as per existing, varnishing the re-winded motor and heating up the same in heat chamber to obtain the insulation resistance not less than 0.6 Ohms, make the same in serviceable condition reassembling the motor and testing on ground including reinstallation and relowering the pump set after completion of repair/ replacement work complete as directed. Note : New spares as required shall be measured and paid separately as "Supply only" as under:-
Supply only Bushing suitable for 10 HP pump set
Supply only coupling for 10 HP pump set
M&L for Shaft lapping and cutting complete all as directed
Chemical and bacteeriological testing of water sample collected from over head tank, UG Sump and consumer end of other than Basistha area(Borjhar, Sadalipur, Amingoan, Bhootnath, MC Group, Transit Camp, Training area) (one water sample to be collected from each place) once in six month to ensure potability of water from any Government approved laboratory complete all as directed. Note:- Cost collecting the sample, transporting the sample to the lab and submitting the Test report is demmed to be inclusive of the UNIT RATE QUOTED.
M&L painting of CI/DI/GI pipe line of any size in various MES pump houses located in other than Basistha area with one coat of syntheic enamel paint and writing of inlet/outlet direction, area of feeding etc, as directed including necessary preperation of surfaces complete all directed.
S&F in repairs,water pressure guage of capacity 7.5Kg/Sqmm, guage dial type complete all as directed
M&L repair of broken pipe line, removing leakage of water pipe lines of size 80mm to 150mm bore pipe of any description such as CI/DI pipe line at any locations of other than Basistha area under AGE E/M Guwahati, including necessary earthwork, dewatering if required, and removing leakage(s) complete all as directed. Note:- (i) Cost of fittings such as flanges, special fittings like Tee, socket, Coller, Tail Piece, bend etc as required , rubber/gland packing, lead joint etc as required is deemed to be inclusive in the UNIT Quoted Rate, and nothing extra shall be payable.
M&L repair of broken pipe line, removing leakage of water pipe lines of size upto 50mm bore pipe of any description such as CI/DI pipe line at any locations of other than Basistha area under AGE E/M Guwahati, including necessary earthwork, dewatering if required, and removing leakage(s) complete all as directed. Note:- (i) Cost of fittings such as flanges, special fittings like Tee, socket, Coller, Tail Piece, bend etc as required , rubber/gland packing, lead joint etc as required is deemed to be inclusive in the UNIT Quoted Rate, and nothing extra shall be payable.
Making connection of PP-R distribution branch with PP-R main of size 16 to 40mm outer dia. by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed.
Making connection of PP-R distribution branch with PP-R main of size 50 to 75mm outer dia. by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed.
S&F in repair, 25mm bore GI pipe medium grade water tube with all fittings laid in trenches complete all as specified and as directed.
S&F in repair, 32mm outer dia. PP-R Ball valves (brass insert) high pressure with polythene float and flynut screwed for iron/PPR pipe or brass ferrule and fixed complete all as specified and as directed.
S&F in repair, 25mm outer dia. PP-R Ball valves (brass insert) high pressure with polythene float and flynut screwed for iron/PPR pipe or brass ferrule and fixed complete all as specified and as directed.
M&L 110mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches including taking out the old unserviceable pipe complete all as specified and as directed. complete all as specified and as directed.
M&L 90mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches including taking out the old unserviceable pipe complete all as specified and as directed. complete all as specified and as directed.
M&L 63mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches including taking out the old unserviceable pipe complete all as specified and as directed. complete all as specified and as directed.
M&L 50mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches including taking out the old unserviceable pipe complete all as specified and as directed. complete all as specified and as directed.
M&L 32mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches including taking out the old unserviceable pipe complete all as specified and as directed. complete all as specified and as directed.
M&L in repair, 63mm outer diameter, PP-R Gate valves (brass insert) complete all as specified and as directed.
M&L in repair, 50mm outer diameter, PP-R Gate valves (brass insert) complete all as specified and as directed.
M&L in repair, 32mm outer diameter, PP-R Gate valves (brass insert) complete all as specified and as directed.
S&F in repair, 50mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repair, 32mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repair CI sluice valve of size 150 mm bore with brass spindle and cast iron hand wheel head & brass spindle complying with IS:14846-2000, class PN 1.6 both ends flanged complete with rubber/fibre board insertion gasket joints, nuts, bolts & washers of required size & Nos complete all as specified and as directed.
TONMOY DAS
S. R. TRADING
M/S SEWAK SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .