Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT NO 438 10TH EAST CROSS STREET ARINGAR ANNA NAGAR MADURAI MADURAI TAMIL NADU 625020 | MADURAI | TAMIL NADU | 625020 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance A 245 OKHLA INDUSTRIAL AREA PHASE I DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Admitted-Finance |
| 4 | Admitted-Finance 501 5TH FLOOR HUB TOWN SOLARIS N S PHADKE MARG ANDHERI E MUMBAI MAHARASHTRA 400069 | MUMBAI | MUMBAI | MAHARASHTRA | 400069 | Admitted-Finance |
| 5 | Admitted-Finance 10 DR RADHAKRISHNAN NAGAR ARUMBAKKAM CHENNAI TAMILNADU 600106 | CHENNAI | TAMIL NADU | 600106 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
25 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
THE DIRECTOR JIPMER
THE DIRECTOR JIPMER PUDUCHERRY
RATE CONTRACT for supply of CONSUMABLES and NON CONSUMABLES for the Department of CTVS for 2021 22
2021_JIPMP_642125_1
JIP/PUR6(1)/OeT/CTVS/2021-22
Open Tender
Consumables (Hospital / Lab)
Supply
365 days
JIPMER PUDUCHERRY
Please refer Tender documents.
10 documents required · 10 mandatory
₹590
Payable To THE DIRECTOR JIPMER
Exempted
31 Mar 2022
6 Aug 2021
27 Sept 2021
6 Aug 2021
25 Sept 2021
14 Aug 2021
6 Aug 2021 - 10 Aug 2021
365 days
Perfusion Technological Consumables-Abbreviations Used MSA - Membrane surface Area, BFR - Blood Flow rate SPV - Static Priming Volume, CVR - Cardiotomy venous reservoir. PV - Priming volume, BHPSC - Biocompatible hydrophilic polymer surface coating, HE - Heat Exchanger. SS - Stainless Steel SPR - Sample to be Provided
Membrane Oxygenator- Large Adult - Type A MSA = 1.7 to1.8m², Max. BFR = 8L/min, SPV≤ 220ml, CVR ≥ 4500ml, Surface must be coated, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator- Large Adult - Type B MSA = 1.4 to 1.8m², Max BFR =6 L/min, SPV ≤ 185ml, CVR ≥ 4500ml Coated Surface -Polyurethane HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator- Large Adult - Type C MSA = 1.4 to1.8m², Max BFR = 6 L/min, SPV ≤ 185ml, CVR ≥ 4500ml, Integrated Arterial filter, Surface must be coated, Polyurethane HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator- Small Adult - Type A MSA=1.3 to 1.5 m², Max BFR= 5 L/min, SPV ≤ 175ml, CVR ≥ 4000ml. Biocompatible surface coating preferable. Stainles Steel HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator- Small Adult - Type B MSA = 1.3 to1.5 m², Max BFR =5L /min,SPV ≤ 295ml, CVR ≥ 4000ml. Integrated arterial filter, SS-HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator- Small Adult - Type C MSA= 1.5m², Max BFR= 4 L/min, SPV ≤ 135 ml, Hard shell reservoir capacity 3000-3200ml, Metal HE. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator- Pediatric - Type A MSA ≤ 1.1m², Max. BFR 2.8 to3.5L/min, SPV ≤ 130ml, CVR ≥ 2500ml, SS- HE integrated with oxygenator. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator - Pediatric - Type B MSA ≤ 0.8m², Max BFR 2.1 -2.8 L /min, SPV≤ 100ml, CVR ≤ 1500ml, SS-HE integrated with oxygenator. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator-Pediatric - Type C MSA ≤ 0.67m², Max BFR = 2 L/min, SPV ≤ 48ml. Integrated HE of Terephthalate (PET) Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator- Infant MSA ≤ 0.5m², Max BFR = 1.5 L /min, SPV ≤ 43ml, Integrated SS-HE. Biocompatible hydrophilic polymer surface coating . Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator- Neonate MSA ≤ 0.35m², Max BFR= 1 L /min, SPV ≤ 38ml, integrated SS-HE , Coated surface. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Membrane Oxygenator- Dual Chamber CVR integrated with arterial filter MSA = 1.6 to 1.85m², Max BFR -7 L/min, SPV ≤ 350ml, Coated surface, Two-step lipid-leukocytes depletion CVR, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO Oxygenator -Adult MSA ≥1.8m², Max BFR= 7 L/min, SPV ≤ 250 ml. CVR=4 Lit, Diffusion membrane material Polymethyl pentene. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO Oxygenator - Small Adult MSA ≥1.2m², Max BFR= 5L/min, SPV ≤ 150 ml. CVR=3 Lit Diffusion membrane material Polymethyl pentene. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO Oxygenator-Pediatric MSA ≥ 0.67m², Max BFR up to 4L/min, SPV ≤ 90 ml. CVR=2.5 Lit Diffusion membrane material Polymethyl pentene Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO Oxygenator -Neonate MSA ≥ 0.69m², Max BFR=1.5 L/min, SPV ≤ 95ml. CVR = 1.5 Lit. Diffusion membrane material Polymethyl pentene. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO oxygenator with circuit for multipurpose use - ADULT TYPE 1 MSA ≥1.8m², Max BFR= 7L/min , SPV ≤ 250 ml, RF-32 or Flo Pump32 centrifugal Pump Head, Diiffusion membrane of Polymethylpentene. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO oxygenator with circuit for multipurpose use -ADULT TYPE 2 MSA ≥ 1.8m², Max BFR= 7 L/min, SPV ≤ 250 ml, Vaned Impeller design of pump head - Diffusion membrane material Polymethylpentene, - 3/8 inch inlet & outlet with housing to fit the centrifugal console of APS-I (Terumo) & SORIN S5 (CP5), Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO oxygenator with circuit for multipurpose use - SMALL ADULT TYPE 1 MSA ≥ 1.5m², Max BFR= 5L/min , SPV ≤ 200 ml, RF-32 or Flo Pump32 centrifugal Pump Head, Diffusion membrane material Polymethylpentene , Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO oxygenator with circuit for multipurpose use - SMALL ADULT TYPE 2 MSA ≥ 1.5m², Max BFR= 5L/min, SPV ≤ 200 ml, Vaned Impeller design pump head, Diffusion membrane material Polymethylpentene , 3/8 inch inlet & outlet with housing to fit the centrifugal console of APS-I (Terumo) & SORIN S5 ( CP5) Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO oxygenator with circuit for multipurpose use - PEDIATRIC TYPE 1 MSA ≥0.69m², Max BFR = 1.5.L/min, SPV ≤90 ml. 'RF-32 or FloPump32' centrifugal Pump Head, Polymethylpentene membrane, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
ECMO oxygenator with circuit for multipurpose use - PEDIATRIC TYPE 2 MSA ≥ 0.69m², Max BFR= 1.5L/min, SPV ≤90 ml. Vaned Impeller design pump head, Polymethylpentene membrane, 3/8 or 1/4 inch inlet & outlet with housing to fit the centrifugal console of APS-I (Terumo) &SORINS5( CP5). Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Hemofilter- Big Adult MSA ≤ 1.4m², PV ≤ 80 ml, To be supplied with tubing set & collection bag & a suitable holder Primary Pack should be labelled.SPR
Hemofilter- Adult MSA = 1.1m², PV ≤ 71 ml, To be supplied with tubing set & collection bag & a suitable holder Primary Pack should be labelled. SPR
Hemofilter- Small Adult MSA ≤ 0.71m², PV ≤ 65 ml,To be supplied with tubing set & collection bag & a suitable holder Primary Pack should be labelled. SPR
Hemofilter -Pediatric MSA ≤ 0.3m², PV ≤ 35 ml, To be supplied with tubing set & collection bag & a suitable holder Primary Pack should be labelled. SPR
Hemofilter-Infant MSA ≤0.1m², PV ≤ 20 ml, To be supplied with tubing set & collection bag & a suitable holder Primary Pack should be labelled. SPR
Arterial filter - Adult Max BFR=7 L/min, SPV ≤ 125 ml, Pore size-37µm, Blood port= 3/8 inch Bypass loop & 3-way with one-way valve purge line & a suitable holder - to be supplied. Primary Pack should be labelled. SPR
Arterial filter - Small Adult Max BFR=4L/min, SPV ≤ 80 ml, Pore size-37µm,Blood port= 3/8 inch Bypass loop & 3-way with one-way valve purge line & a suitable holder - to be supplied. Primary Pack should be labelled. SPR
Arterial filter - Pediatric Max BFR=2.5 L/min, SPV ≤ 40 ml, Pore size-32µm, Blood port=1/4 inch. Bypass loop & 3way with one-way valve purge line & a suitable holder - to be supplied.Primary Pack should be labelled. SPR
Custom pack -Adult - tubing set for CPB as per JIPMER 2020 Circuit. (contact CTVS dept for Figures)
Custom pack -Small Adult -tubing set for CPB as per JIPMER 2020 Circuit. (contact CTVS dept for Figures)
Custom pack -Pediatric tubing set for CPB as per JIPMER 2020 Circuit. (contact CTVS dept for Figures)
Custom pack -Neonatal tubing set for CPB as per JIPMER 2020 Circuit. (contact CTVS dept for Figures)
ECMO Adult tubing set Custom pack as per the JIPMER 2020 circuit. Primary Pack should be labelled. SPR . (contact CTVS dept for Figures)
ECMO Pediatric tubing set Custom pack as per the JIPMER 2020 circuit. Primary Pack should be labelled. SPR . (contact CTVS dept for Figures)
Cardio plegia delivery system (CPDS) - Reservoir Type Minimum 2-L Reservoir capacity with at least 4 x 1/4” ports with holder Primary Pack should be labelled. . SPR
Cardio plegia delivery system (CPDS) - 4:1 type PV ≤ 30ml, Max BFR ≥ 2.5 L/min with 3-way with purge line. Preferably with groved stainless steel HE & 150 µm polyester screen filter. Primary Pack should be labelled. Holder to be supplied. SPR
Centrifugal pump head - Adult type 1 Vaned Impeller design, 3/8 "inlet & outlet with housing to fit the centrifugal console of heart lung machine of APS-I (Terumo – Sarns) & SORIN S5 (CP5).SPR
Centrifugal pump head - Adult Type 2 Priming Volume ≤ 32ml, 3/8 inch inlet & outlet with housing to fit the centrifugal console of Rotaflow (Maquet). The pump head should be without a metal shaft or seal.SPR
Centrifugal pump head - Pediatric Type 1 Vaned Impeller design, 1/4" inlet & outlet with housing to fit the centrifugal console of heart lung machine of APS-I (Terumo–Sarns) & SORIN S5 (CP5). SPR
Centrifugal pump head - Pediatric Type 2 1/4" inlet & outlet with housing to fit the centrifugal console of Rotaflow (Maquet). The pump head should be without a metal shaft or seal. SPR
Intra Aortic balloon (compatible with Arrow IABP machine)-30 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
Intra Aortic balloon (compatible with Arrow IABP machine) 34 / 35 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
Intra Aortic balloon (compatible with Arrow IABP machine)- 40 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
Intra Aortic balloon (compatible with Arrow IABP machine)- 50 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
Pressure transducers -Single type for heart lung machine Sarns Heart Lung machine and APS-I with 200 cm pressure line & a pressure cable suitable for the device and the machine has to be supplied free of cost with every 100 transducers purchased - SPR
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size A - 3/16" x 3/16".
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size B - 1/4" x 1/4"..
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size C - 3/8" x 3/8".
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size D - 1/4" x 3/8".
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size E - 3/8" x 1/2".
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size A - 3/16" x 3/16" x 3/16"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size B - 3/16" x 1/4" x 1/4"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size C - 1/4" x 1/4" x 1/4"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size D - 1/4" x 1/4" x 3/8"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size E - 3/8" x 3/8" x 3/8"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size F - 3/8" x 3/8" x 1/4"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size G - 1/2''x 3/8''x 3/8''
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size H - 3/16" x 1/4" x 3/8"
HTK type - single shot cardioplegiaHistidine – Tryptophan – Ketoglutarate (HTK) type. cardioplegic solution for myocardial protection for at least 3 hours after a single shot of cardioplegia. 1 litre
HTK type - single shot cardioplegiaHistidine – Tryptophan – Ketoglutarate (HTK) type. cardioplegic solution for myocardial protection for at least 3 hours after a single shot of cardioplegia. 0.5 litre
Multiple perfusion adapter set with 4 legs (3 long +1 short leg) with individual tubing clamps for simultaneous perfusion of venous grafts and aortic root - with female luer inlet & male luer outlets preferably with length of- at least 10" (refer fig.) SPR.
Minimally invasive vascular access Kit for femoral arterial cannulation for CPB or ECMO with Scalpel (#11), Seldinger Needle (18G) Stepped vessel dilator - 8 F/10 F, 12 F/14 F & 16 F/18 F, Guidewire - 0.038" (0.965-mm) -100 cm long -for cannulation - SPR
Minimally invasive vascular access kit for femoral venous Cannulation for CPB or ECMO With Scalpel (#11), Seldinger Needle (18G) Stepped vessel dilator - 8 F/10 F, 12 F/14 F and 16 F/18 F, Guidewire - 0.038" (0.965-mm) -180 cm long- SPR
Minimally invasive Vascular access Kit for jugular venous Cannulation for CPB or ECMO With Scalpel (#11), Seldinger Needle (18G) Stepped vessel dilator - 8 F/10 F, 12 F/14 F Guidewire - 0.025" (0.535-mm) -60 cm long-for cannulation SPR
Dual lumen catheter 13 F for venovenous ECMO with Insertion kit having 100 cm guidewire , suitable Seldindinger puncture needle. SPR
Dual lumen catheter 16 F for venovenous ECMO with Insertion kit having 100 cm guidewire , suitable Seldindinger puncture needle. SPR
Dual lumen catheter 19 F for venovenous ECMO with Insertion kit having 100 cm guidewire , suitable Seldindinger puncture needle. SPR
Dual lumen catheter 20 F for venovenous ECMO with Insertion kit having 210 cm guidewire , suitable Seldindinger puncture needle. SPR
Dual lumen catheter 23 F for venovenous ECMO with Insertion kit having 210 cm guidewire , suitable Seldindinger puncture needle. SPR
Dual lumen catheter 27 F for venovenous ECMO with Insertion kit having 210 cm guidewire , suitable Seldindinger puncture needle. SPR
Dual lumen catheter 31 F for venovenous ECMO with Insertion kit having 210 cm guidewire , suitable Seldindinger puncture needle. SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 8F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 10F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 12F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 14F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 16F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 18F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 20F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 22F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 24F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic /arterial Perfusion Cannula -Angled (45 deg) wirewound - Size 20F - Overall at least 12 inches with transparent & wirewound body, angled (45 deg) bevelled tip with side holes, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic /arterial Perfusion Cannula -Angled (45 deg) wirewound - Size 22F - Overall at least 12 inches with transparent & wirewound body, angled (45 deg) bevelled tip with side holes, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic /arterial Perfusion Cannula -Angled (45 deg) wirewound - Size 24F - Overall at least 12 inches with transparent & wirewound body, angled (45 deg) bevelled tip with side holes, tip orientation line and tip guard preferably with vented type connector - SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 6F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 8F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 10F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 12F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 14F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 16F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Adult Size 18F - with thin walled vented type tip, introducer & depth markings, radioopaque adjustable suture collar - overal length of at least 12 inch long preferably with guidewire. SPR
Elongated Aortic /arterial Perfusion Cannula - Adult Size 20F - with thin walled vented type tip, introducer & depth markings, radioopaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire. SPR
Elongated Aortic /arterial Perfusion Cannula - Adult Size 22F - with thin walled vented type tip, introducer & depth markings, radioopaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire. SPR
Elongated Aortic /arterial Perfusion Cannula - Adult Size 24F - with thin walled vented type tip, introducer & depth markings, radioopaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire. SPR
Venous Return Cannula - single stage -- straight 12F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 14F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 16F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 18F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 20F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 22F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 24F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 26F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 28F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 30F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 32F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 34F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 36F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 38F multiport tapered tip with kink resistant wirewound body- over all length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 10F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 12F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 14F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 16F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 18F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 20F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 22F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 24F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 26F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 28F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula-Cuffed single stage - 37F - wirewound body at least 35 cm long with inflatable cuff - SPR
Venous return cannula -Two Stage flat body- 28/36F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 29/29F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 29/37F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 32/40F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 36/46F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 34/46F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 36/51F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -three Stage -Oval body- 29/29/29 F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -three Stage -Oval body- 29/46/37 F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Femoral Arterial Perfusion cannula (Pediatric) - 8F with depth marking, introducer with central lumen - SPR
Femoral Arterial Perfusion cannula (Pediatric) - 10F with depth marking, introducer with central lumen - SPR
Femoral Arterial Perfusion cannula (Pediatric) - 12F with depth marking, introducer with central lumen - SPR
Femoral Arterial Perfusion cannula (Pediatric) - 14F with depth marking, introducer with central lumen - SPR
Femoral Arterial Perfusion cannula (Adult) - 15F or 16F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 17F or 18F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 19F or 20F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 21F or 22F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 23F or 24F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 25F or 26F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Venous Perfusion cannula (Pediatric) - 8F - with Wire wound body,introducer & depth marking & overall length of at least 19 cm- SPR
Femoral Venous Perfusion cannula (Pediatric) - 10F - with Wire wound body,introducer & depth marking & overall length of at least 19 cm- SPR
Femoral Venous Perfusion cannula (Pediatric) - 12F - with Wire wound body,introducer & depth marking & overall length of at least 19 cm- SPR
Femoral Venous Perfusion cannula (Pediatric) - 14F - with Wire wound body,introducer & depth marking & overall length of at least 19 cm- SPR
Femoral Venous Perfusion cannula (Adult) -15F-or 16 F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Femoral Venous Perfusion cannula (Adult) -17F-or 18 F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Femoral Venous Perfusion cannula (Adult) -19F-or 20 F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Femoral Venous Perfusion cannula (Adult) -21F-or 22 F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Femoral Venous Perfusion cannula (Adult) -23F-or 24 F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Femoral Venous Perfusion cannula (Adult) -25F-or 26 F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Femoral Venous Perfusion cannula (Adult) -27F-or 28 F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Femoral Venous Perfusion cannula (Adult) -29 F or 30F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Cardio-plegic Cannula-Antegrade 3F (18G) with introducer needle, standard tip preferably with side holes - SPR
Cardio-plegic Cannula-Antegrade 4F with introducer needle, standard tip preferably with side holes - SPR
Cardio-plegic Cannula-Antegrade 5F (16G) with introducer needle, standard tip preferably with side holes - SPR
Cardio-plegic Cannula-Antegrade 6F or 7F (14G) with introducer needle, standard tip preferably with side holes - SPR
Cardio-plegic Cannula-Antegrade 8F or 9F (12G) with introducer needle, standard tip preferably with side holes - SPR
Cardio-plegic Cannula-Antegrade 11F with introducer needle, standard tip preferably with side holes - SPR
Cardioplegic Cannula-Antegrade with side limb - 4F with introducer needle, standard tip preferably with side holes and a side limb for venting - SPR
Cardioplegic Cannula-Antegrade with side limb - 5F (16G) with introducer needle, standard tip preferably with side holes and a side limb for venting - SPR
Cardioplegic Cannula-Antegrade with side limb - 6F or 7F (14G) with introducer needle, standard tip preferably with side holes and a side limb for venting - SPR
Cardioplegic Cannula-Antegrade with side limb - 8F or 9F (12G) with introducer needle, standard tip preferably with side holes and a side limb for venting - SPR
Cardioplegic Cannula-Antegrade with side limb - 11F with introducer needle, standard tip preferably with side holes and a side limb for venting - SPR
Cardioplegia cannula -Minimally Invasive Antegrade type with introducer needle with standard tip with a length of at least 30 cm- SPR
Cardioplegia cannula - Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of 12F (4mm) & tip of 2.1 mm-SPR
Cardioplegia cannula - Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of 15F (5mm) & tip of 2.1 mm-SPR
Cardioplegia cannula - Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of 18F (6mm) & tip of 3 mm-SPR
Cardioplegia cannula - Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of 21F (7mm) & tip of 3 mm-SPR
Cardioplegia cannula - Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of 24F (8mm) & tip of 3.5 mm-SPR
Cardioplegia cannula - Flexible Coronary Ostial right angled type with soft silicone bulb /balloon of 12F (4mm) & tip of 2.1 mm-SPR
Cardioplegia cannula - flexible Coronary Ostial right angled type with soft silicone bulb /balloon of 15F (5mm) & tip of 2.1 mm-SPR
Cardioplegia cannula - flexible Coronary Ostial right angled type with soft silicone bulb /balloon of 18F (6mm) & tip of 3 mm-SPR
Cardioplegia cannula - flexible Coronary Ostial right angled type with soft silicone bulb /balloon of 21F (7mm) & tip of 3 mm-SPR
Cardioplegia cannula - Flexible Coronary Ostial right angled type with soft silicone bulb /balloon of 24F (8mm) & tip of 3.5 mm-SPR
Cardioplegia cannula - Flexible Coronary Ostial Tapering type with soft self-inflating ballooon - tip tapering from 27F (9mm) to 8F (2.7mm) and body encapsulated with malleable wire- SPR
Cardioplegia cannula - Rigid left Coronary Ostial type - 45 deg angled basket tip -10F (3.3mm) SPR
Cardioplegia cannula - Rigid left Coronary Ostial type - 45 deg angled basket tip - 12F (4mm) SPR
Cardioplegia cannula - Rigid left Coronary Ostial type - 45 deg angled basket tip -14F (4.7 mm)- SPR
Cardioplegia cannula - Rigid Right Coronary Ostial type -80-90 deg angled basket tip -10F (3.3mm) SPR
Cardioplegia cannula - Rigid Right Coronary Ostial type -80-90 deg angled basket tip - 12F (4mm) SPR
Cardioplegia cannula - Rigid Right Coronary Ostial type -80-90 deg angled basket tip -14F (4.7 mm)- SPR
Retrograde cardioplegia cannula (Coronary sinus) with Solid Stylet 13F -with auto-inflatable cuff & integral stop cock for pressure monitoring - Preferably wirewound body - SPR
Retrograde cardioplegia cannula (Coronary sinus) with Solid Stylet 15F -with auto-inflatable cuff & integral stop cock for pressure monitoring - Preferably wirewound body - SPR
Cardiac suction tip- (Mini sucker) soft flexible tapered tip - 9F (3mm) - with angled shaft - SPR
Cardiac suction tip- (Mini sucker) soft flexible tapered tip - 12F (3mm) - with angled shaft - SPR
Intra-cardiac suction tip- Rigid - 20F (6.7mm) fluted pool tip - with 16F (5.3mm) - angled metal shaft at least 15 cm long - SPR
Frazier tip- suction - Small & short 6F tip & shaft - about 7.5cm long - SPR
Frazier tip- suction - Small & long 6F tip & shaft - about 15cm long - SPR
Frazier tip- suction - Large -10 F tip & shaft - about 10 cm long - SPR
Intracardiac / pericardial sump suction Type 1: 20 F tip with metal weighted perforated pool tip & flexible tubing at least 30 cm long - SPR
Intracardiac / pericardial sump suction Type 2: 12 F tip with metal weighted perforated pool tip & flexible tubing at least 30 cm long - SPR
Intracardiac / pericardial sump suction Type 3: 20 F tip with spring encased fluted pool tip & flexible tubing at least 30 cm long terminating into a 1/4" connector - SPR
Left Heart Vent Catheter (type 1) PVC tip with malleable body 10F (3.3 mm) with vented connector - SPR
Left Heart Vent Catheter (type 1) PVC tip with malleable body 13F (4.3 mm) with vented connector - SPR
Left Heart Vent Catheter (type 1) PVC tip with malleable body 15F (5 mm) with vented connector - SPR
Left Heart Vent Catheter (type2) Silicone tip with malleable introducer 16F (5.3 mm)- SPR
Left Heart Vent Catheter (type2) Silicone tip with malleable introducer 20F (6.7 mm)- SPR
Left atrial pressure monitoring catheter - 3F (1mm) = 20 G set of at least 50 cm long with depth markings, attached to a female luer, peelaway needle tip and a self adhesive anchoring collar for securing the catheter at the desired location - SPR.
Left atrial pressure monitoring catheter - 4F (1.43mm) = 17 G set of at least 50 cm long with depth markings, attached to a female luer, peelaway needle tip and a self adhesive anchoring collar for securing the catheter at the desired location - SPR.
Left atrial pressure monitoring catheter - 5F (1.7mm) = 15 G set of at least 50 cm long with depth markings, attached to a female luer, peelaway needle tip and a self adhesive anchoring collar for securing the catheter at the desired location - SPR.
Disposable Yankur suction cannula with transparent connecting tube of at least 1 meter long
Red rubber latex catheters - 8F for vessel snugging - High quality and tension resistant body - at least 16" long overal. -SPR
Red rubber latex catheters - 8F for vessel snugging - High quality and tension resistant body - at least 16" long overal. -SPR
Red rubber latex catheters - 10F for vessel snugging - High quality and tension resistant body - at least 16" long overal. -SPR
Red rubber latex catheters - 12F for vessel snugging - High quality and tension resistant body - at least 16" long overal. -SPR
Red rubber latex catheters - 14F for vessel snugging - High quality and tension resistant body - at least 16" long overal. -SPR
Red rubber latex catheters - 16F for vessel snugging - High quality and tension resistant body - at least 16" long overal. -SPR
Vascular tourniquet (Snugger) set Adult (7" long) for open heart surgery - color coded 4 tubes with one snare- for snugging the purse string sutures during open heart procedures - SPR
Vascular tourniquet (Snugger) set Pediatric (6" long) for open heart surgery - color coded 4 tubes with one snare- for snugging the purse string sutures during open heart procedures - SPR
Silicone vessel (vascular) loop - Large size sterile medical grade radioopaque silicone loop 2 to 2.5 mm wide , < 1.2 mm thick & at least 40 cm long. for encircling the blood vessels during dissection. To be available in at least 3-4 colors (in each size) - preferably indiviual loop packed in a separate foil. The cost of a single loop will be taken for comparison purpose and hence the number of loops present in a single pack needs to be mentioned -SPR
Silicone vessel (vascular) loop - Small size sterile medical grade radioopaque silicone loop 1 to 1.3 mm wide, < 1 mm thick & at least 40 cm long. for encircling the blood vessels during dissection. To be available in at least 3-4 colors (in each size) - preferably indiviual loop packed in a separate foil. The cost of a single loop will be taken for comparison purpose and hence the number of loops present in a single pack needs to be mentioned -SPR
Silicone vessel (vascular) loop - Tiny size sterile medical grade radioopaque silicone loop 0.5 mm wide, < 0.4 mm thick & at least 40 cm long. for encircling the blood vessels during dissection. To be available in at least 3-4 colors (in each size) - preferably indiviual loop packed in a separate foil. The cost of a single loop will be taken for comparison purpose and hence the number of loops present in a single pack needs to be mentioned -SPR
Air-cushioned - Silicone vessel (vascular) loop with needle - medical grade silicone loop with hollow interior for the air-cushion effect - with the maximum diameter of the loop less than 1.3 mm (thickness) and at least 25 cm long- SPR
Temporary Epi-myocardial Pacing wire - Adult type - at least 60 cm long for intraoperative placement during cardiac surgery- Incorporating a straight cutting needle of at least 60 mm long with ‘breakaway’ feature enabling the remaining butt to be used as a connecting plug to the Pace maker. The other end of the wire should have 25 to 27 mm tapercut 1/2 circle needle -SPR
Temporary Epi-myocardial Pacing wire - Pediatric type - at least 60 cm long for intraoperative placement during cardiac surgery- Incorporating a straight cutting needle of at least 60 mm long with ‘breakaway’ feature enabling the remaining butt to be used as a connecting plug to the Pace maker. The other end of the wire should have 16 to 18 mm tapercut 1/2 circle needle -SPR
Sternal closure polymer bands Sterile bands (of less than 5 mm width) made of biocompatible & MRI compatible poly-ether-ether-ketone polymer substance in a pack of 5 bands - These bands must be amenablefor being cut open with standardwire cutters in case of sternal re-entry procedures.
Coronary shunts (silicon type) 1 mmm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Coronary shunts (silicon type) 1.25 mmm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Coronary shunts (silicon type) 1.5 mmm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Coronary shunts (silicon type) 1.75 mmm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Coronary shunts (silicon type) 2 mm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Disposable Aortic -Vascular Punch 2.5 to 2.8 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
Disposable Aortic -Vascular Punch 3 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
Disposable Aortic -Vascular Punch 3.5 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
Disposable Aortic -Vascular Punch 4 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
Angled Disposable Bull Dog Type Vascular clamp- Type A with clamping pressure of 10-15G used for CABG. . Should be radiopaque & light weight with atraumatic jaw types - SPR .
Angled Disposable Bull Dog Type Vascular clamp- Type B with clamping pressure of 20-25G used for CABG. . Should be radiopaque & light weight with atraumatic jaw types - SPR .
Angled Disposable Bull Dog Type Vascular clamp- Type C with clamping pressure of 75-80G used for CABG. . Should be radiopaque & light weight with atraumatic jaw types - SPR .
Angled Disposable Bull Dog Type Vascular clamp- Type D with clamping pressure of 165-175G used for CABG. . Should be radiopaque & light weight with atraumatic jaw types - SPR .
Suction based Cardiac Stabilizer - Retracting arm unit type (Octopus like) for OPCAB (off pump coronary artery bypass). The retracting arms unit should have surgeon controlled pod-spread, allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications, one-handed engagement of clamp and turret assembly.
Suction based Cardiac Stabilizer - Apex positioner (Starfish like) for OPCAB (off pump coronary artery bypass). Should enhance lifting the apex of the heart and fixing to any positon.
Mist blowing device for OPCAB (off pump coronary artery bypass). With fluid/gas mixing technology creating a consistent, predictable blood clearing mist. On/off control in hand-piece - Malleable shaft - Specialized nozzle, utilizing a micro-orifice for fluid delivery and a separate orifice for gas delivery - SPR
Vessel cannula - 3 mm tip - with stepped contour - transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm SPR. transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm SPR.
Vessel cannula - 2 mm tip - with stepped contour - transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm SPR. transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm SPR.
IMA (Internal Mammary Arterial) cannula -1mm - with bulb shaped tip for checking patency of the artery
Arteriotomy cannula - 2 mm with polyurethane tube with a bulb shaped tip connected to a winged female luer about 5 cm long - SPR
Custom made Elastic Stockings for lower limbs with suitable applier - made up of a mix of cotton, polyamide & elastane. (Quote only the price of a single stocking not of a pair) for patients after venous harvest or with varicose veins - SPR
Valves General Instructions The valves have to be supplied on consignment basis such that - a stock of one valve in each size should be made available in the user area (CTVS-OT) and after the utilization of a valve of particular size, the same has to be replaced to fill the stock by the firm who supplied the valve. The infromation of utilization of the valve has to be conveyed to the supplier by the storekeeper who inturn will be informed by the SNO of CTVS OT.
Tilting Disc Aortic valve 18/19 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder. Two sets of valve sizer & valve tester have to be suppied with suitable trays (irrespective of the number of valves purchased) for the year
Tilting Disc Aortic valve 20/21 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder. Two sets of valve sizer & valve tester have to be suppied with suitable trays (irrespective of the number of valves purchased) for the year
Tilting Disc Aortic valve 22/23 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder. Two sets of valve sizer & valve tester have to be suppied with suitable trays (irrespective of the number of valves purchased) for the year
Tilting Disc Aortic valve 24/25 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder. Two sets of valve sizer & valve tester have to be suppied with suitable trays (irrespective of the number of valves purchased) for the year
Tilting Disc Mitral valve 25/26 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder. Two sets of valve sizer & valve tester have to be suppied with suitable trays (irrespective of the number of valves purchased) for the year
Tilting Disc Mitral valve 27/28 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder. Two sets of valve sizer & valve tester have to be suppied with suitable trays (irrespective of the number of valves purchased) for the year
Tilting Disc Mitral valve 29/30 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder. Two sets of valve sizer & valve tester have to be suppied with suitable trays (irrespective of the number of valves purchased) for the year
Tilting Disc Mitral valve 31/32 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder. Two sets of valve sizer & valve tester have to be suppied with suitable trays (irrespective of the number of valves purchased) for the year
Bileaflet Aortic valve 16/17 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Aortic valve 18/19 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Aortic valve 20/21 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Aortic valve 22/23 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Aortic valve 24/25 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Aortic valve 26/27 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Mitral valve 16/17 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Mitral valve 18/19 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Mitral valve 20/21 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Mitral valve 22/23 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Mitral valve 24/25 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Mitral valve 26/27 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Mitral valve 28/29 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bileaflet Mitral valve 30/31 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
Bovine pericardial stented bioprosthetic aortic valve 19/20 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 21/22 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 23/24 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 25/26 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 27/28 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 29/30 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic Mitral valve 25/26 mm of the Latest generation technology of the quoted brand with low profile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic Mitral valve 27/28 mm of the Latest generation technology of the quoted brand with low profile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic Mitral valve 29/30 mm of the Latest generation technology of the quoted brand with low profile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic Mitral valve 31/32 mm of the Latest generation technology of the quoted brand with low profile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic Mitral valve 33/34 mm of the Latest generation technology of the quoted brand with low profile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 19/20 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 21/22 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 23/24 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 25/26 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 27/28 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 29/30 mm of the Latest generation technology of the quoted brand with lowest profile height & lowest stent base. With suture markers & contoured and compliant sewing ring with the smallest possible diameter. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic Mitral valve 25/26 mm of the Latest generation technology of the quoted brand with low profile with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic Mitral valve 27/28 mm of the Latest generation technology of the quoted brand with low profile with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic Mitral valve 29/30 mm of the Latest generation technology of the quoted brand with low profile with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic Mitral valve 31/32 mm of the Latest generation technology of the quoted brand with low profile with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic Mitral valve 33/34 mm of the Latest generation technology of the quoted brand with low profile with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic conduit aortic root with valve - 19/20 mm for Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic conduit aortic root with valve - 21/22 mm for Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic conduit aortic root with valve - 23/24 mm for Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic conduit aortic root with valve - 25/26 mm for Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic conduit aortic root with valve - 27/28 mm for Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic conduit aortic root with valve - 29/30 mm for Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bioprosthetic valved conduit (bovine jugular) for Right ventricular to pulmonary arterial conduit. Valve size : 12/13 mm. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
Bioprosthetic valved conduit (bovine jugular) for Right ventricular to pulmonary arterial conduit. Valve size : 14/15 mm. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
Bioprosthetic valved conduit (bovine jugular) for Right ventricular to pulmonary arterial conduit. Valve size : 16/17 mm. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
Bioprosthetic valved conduit (bovine jugular) for Right ventricular to pulmonary arterial conduit. Valve size : 18/19 mm. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
Bioprosthetic valved conduit (bovine jugular) for Right ventricular to pulmonary arterial conduit. Valve size : 20/21 mm. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
Prosthetic Composite Aortic Valved Conduits with valve size 18/19 mm for Bental operation. Should be incorporated with prosthetic bileaflet valve mounted on to collagen impregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . Only 1 number in each size will be in the shelf and purchased as a set during teh first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduits with valve size 20/21 mm for Bental operation. Should be incorporated with prosthetic bileaflet valve mounted on to collagen impregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . Only 1 number in each size will be in the shelf and purchased as a set during teh first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduits with valve size 22/23 mm for Bental operation. Should be incorporated with prosthetic bileaflet valve mounted on to collagen impregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . Only 1 number in each size will be in the shelf and purchased as a set during teh first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduits with valve size 24/25 mm for Bental operation. Should be incorporated with prosthetic bileaflet valve mounted on to collagen impregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . Only 1 number in each size will be in the shelf and purchased as a set during teh first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduits with valve size 26/27 mm for Bental operation. Should be incorporated with prosthetic bileaflet valve mounted on to collagen impregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . Only 1 number in each size will be in the shelf and purchased as a set during teh first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduits with valve size 28/29 mm for Bental operation. Should be incorporated with prosthetic bileaflet valve mounted on to collagen impregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . Only 1 number in each size will be in the shelf and purchased as a set during teh first purchase - as a stock for emergency
Ophthalmic cautery - sterile , disposable & battery operated for making perfect holes in the prosthetic vascular grafts
Annuloplasty complete ring for mitral valve. Size : 23/24 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 25/26 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 27/28 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 29/30 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 31/32 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 33/34 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 35/36 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 25/26 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer . Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 27/28 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer . Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 29/30 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer . Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 31/32 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer . Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 33/34 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer . Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 35/36 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer . Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 37/38 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer . Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 39/40 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer . Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Suture guide / Suture-grip / Suture-organizer of Gabbay Frater mechanism for heart vlave operationsCurved profile with capacity to hold at least 8 paired sutures with positional numbering labelled in a guide with fixation ports. Each sterile pack should contain 3 such guides.
Arterial embolectomy caztheter 2F x 60 cm - enclosed in a rigid case - SPR
Arterial embolectomy caztheter 3F x 80 cm - enclosed in a rigid case - SPR
Arterial embolectomy caztheter 5F x 80 cm - enclosed in a rigid case - SPR
Arterial embolectomy caztheter 7F x 80 cm - enclosed in a rigid case - SPR
PTFE vascular tube grafts 3 mm - at least 10 cm long (peferably thin walled)
PTFE vascular tube grafts 3.5 mm - at least 10 cm long (peferably thin walled)
PTFE vascular tube grafts 4 mm - at least 10 cm long (peferably thin walled)
PTFE vascular tube grafts 4.5 mm- at least 10 cm long (peferably thin walled)
PTFE vascular tube grafts 5 mm - at least 10 cm long (peferably thin walled)
PTFE vascular tube grafts 6 mm - at least 10 cm long
PTFE vascular tube grafts 7 mm - at least 10 cm long
PTFE vascular tube grafts 8 mm - at least 10 cm long
PTFE vascular tube grafts 6 mm - at least 30 cm long
PTFE vascular tube grafts 7 mm - at least 30 cm long
PTFE vascular tube grafts 8 mm - at least 30 cm long
PTFE vascular tube grafts 12 mm - at least 30 cm long
PTFE vascular tube grafts 14 mm - at least 30 cm long
PTFE vascular tube grafts 16 mm- at least 30 cm long
PTFE vascular tube grafts 18 mm - at least 30 cm long
PTFE vascular tube grafts 20 mm - at least 30 cm long
PTFE vascular tube grafts 22 mm - at least 30 cm long
PTFE vascular tube grafts 24 mm - at least 30 cm long
PTFE vascular tube grafts 5 mm - at least 50cm long
PTFE vascular tube grafts 6 mm - at least 50cm long
PTFE vascular tube grafts 7 mm - at least 50cm long
PTFE vascular tube grafts 8 mm - at least 50cm long
PTFE vascular tube grafts - with external support (ringed) 6 mm - at least 70cm long
PTFE vascular tube grafts - with external support (ringed) 7 mm - at least 70cm long
PTFE vascular tube grafts - with external support (ringed) 8 mm - at least 70cm long
Axillo-bifemoral PTFE vascular tube grafts - 8 mm diameter & length of 90 cm plus 50 cm. Purchase will be made individually whenever necessary - S.O.S.
Cuffed ePTFE graft with trim line of 4-6 mm x 60 cm - for ananstamosis with the small recepient vessel of size - 3mm & less. Preferably with in-built antiplatelet / antithrombotic mechanism.
Cuffed ePTFE graft with trim line of 4-6 mm x 90 cm - for ananstamosis with the small recepient vessel of size - 3mm & less. Preferably with in-built antiplatelet / antithrombotic mechanism.
AV access ePTFE graft - 6mm x 40 cm designed specially for for creating AV fistual creation for hemodialysis. The graft should be able to withstand multiple needle punctures without bleeding after the needle is removed.
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 6 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 7 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 8 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 10 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 12 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 14 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 16 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 18 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 20 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 22 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 24 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 26 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 28 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 30 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 32 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 34 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 15 cm long - Dia: 36 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 6 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 7 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 8 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 10 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 12 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 14 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 16 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 18 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 20 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 22 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 24 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 26 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 28 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 30 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 32 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 34 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 36 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 6 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 30 cm long - Dia: 6 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 6 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 7 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 8 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 10 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 12 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 14 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 16 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 18 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 20 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 22 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 24 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 26 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 28 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 60 cm long - Dia: 30 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 90 cm long - Dia: 6 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 90 cm long - Dia: 7 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 90 cm long - Dia: 10 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 90 cm long - Dia: 12 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 90 cm long - Dia: 14 mm
Collagen Impregnated Polyester Straight Tube grafts with crimps - 90 cm long - Dia: 16 mm
Collagen Impregnated - Woven Polyester Bifurcated Tube grafts (with Y limbs) with crimps - 40 to 50 cm long and size (diameter) of limbs : 12 mm x 6 mm
Collagen Impregnated - Woven Polyester Bifurcated Tube grafts (with Y limbs) with crimps - 40 to 50 cm long and size (diameter) of limbs : 14 mm x 7 mm
Collagen Impregnated - Woven Polyester Bifurcated Tube grafts (with Y limbs) with crimps - 40 to 50 cm long and size (diameter) of limbs : 16 mm x 8 mm
Collagen Impregnated - Woven Polyester Bifurcated Tube grafts (with Y limbs) with crimps - 40 to 50 cm long and size (diameter) of limbs : 18 mm x 9 mm
Collagen Impregnated - Woven Polyester Bifurcated Tube grafts (with Y limbs) with crimps - 40 to 50 cm long and size (diameter) of limbs : 20 mm x 10 mm
Polyester fiber suture / ligature 5 mm x at least 40 cm (for Pulmonary arterial banding) SPR
ePTFE Sutures for valve repairs Double armed –90 cm with Taper point 3/8 circle needles – preferably with needle to suture ratio nearer to or equivalent to 1:1. in terms of tensile strength suture : the size : 4-0 (Cost of each foil has to be quoted, In case of quoting the cost for a box, the no.of suture fooils in each box should be mentioned)
ePTFE Sutures for valve repairs Double armed –90 cm with Taper point 3/8 circle needles – preferably with needle to suture ratio nearer to or equivalent to 1:1. in terms of tensile strength suture : the size : 5-0 (Cost of each foil has to be quoted, In case of quoting the cost for a box, the no.of suture fooils in each box should be mentioned)
ePTFE Sutures for valve repairs Double armed –90 cm with Taper point 3/8 circle needles – preferably with needle to suture ratio nearer to or equivalent to 1:1. in terms of tensile strength suture : the size : 6-0 (Cost of each foil has to be quoted, In case of quoting the cost for a box, the no.of suture fooils in each box should be mentioned)
Polybutester suture With polytribolate coating with the property of needle hole self-sealing for vascular anastamoses. Size 7-0 x 60 cm with 3'/8 circle 8mm needle (Cost of each foil has to be quoted, In case of quoting the cost for a box, the no.of suture fooils in each box should be mentioned)
Polyester patch - Type A (Woven fabric) - 0.25 mm thick. - 5cm x 10 cm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type A (Woven fabric) - 0.25 mm thick. - 10cm x 10 cm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type A (Woven fabric) - 0.25 mm thick. - 15cm x 15 cm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 6 mm x 76 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 8 mm x 76 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 8 mm x 152 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 25 mm x 76 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 25 mm x 152 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 25 mm x 50 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 25 mm x 100 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 50 mm x 50 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 75 mm x 75 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 100 mm x 100 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 6 mm x 75 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 10 mm x 140 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 20 mm x 140 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 25mm x 50 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 25 mm x 75 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 25 mm x 100 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 25 mm x 150 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 50 mm x 50 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 50 mm x 75 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 50 mm x 150 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 75 mm x 75 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size: 100 mm x 100 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type E (Double velour - Woven fabric) - 0.46 mm thick - Size : 25mm x 152 mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type E (Double velour - Woven fabric) - 0.46 mm thick - Size : 51mm x 76 mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type E (Double velour - Woven fabric) - 0.46 mm thick - Size : 51mm x 152 mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 6 mm x 76 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 6 mm x 122 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 8 mm x 76 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 8 mm x 152 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 25 mm x 76 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 25 mm x 152 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 50 mm x 15 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F(Double velour - knitted fabric) - 0.76 mm thick. Size: 60 mm x 30 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F(Double velour - knitted fabric) - 0.76 mm thick. Size: 70 mm x 15 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 80 mm x 40 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 100 mm x 15 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 120 mm x 40 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F (Double velour - knitted fabric) - 0.76 mm thick. Size: 120 mm x 80 mm. Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G (Double velour - knitted fabric) -1.5 mm thick - 25 mm x 50 mm as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G (Double velour - knitted fabric) -1.5 mm thick - 25 mm x 100 mm as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G (Double velour - knitted fabric) -1.5 mm thick - 50 mm x 50 mm as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G (Double velour - knitted fabric) -1.5 mm thick - 50 mm x 100 mm as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G (Double velour - knitted fabric) -1.5 mm thick -100 mm x 100 mm as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PET (polyethylene Pteriphthalate) patch about 8 mm x 75 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
PET (polyethylene Pteriphthalate) patch about25 mm x 76 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
PET (polyethylene Pteriphthalate) patch about 25 mm x 152mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
PET (polyethylene Pteriphthalate) patch about 50 mm x 76 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
PET (polyethylene Pteriphthalate) patch about 50 mm x 152 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 20 mm x 30 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 20 mm x 75 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 15 mm x 20 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 8 mm x 30 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 6 mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 8 mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 10 mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 20 mm x 90mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 8mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 10 mm x 90 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 25mm x 150mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 30mm x 30mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 30mm x 60mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 50mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type C (0.4 mm thick) - 10 mm x 90 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type C (0.4 mm thick) - 20 mm x 90 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type C (0.4 mm thick) - 30 mm x 60 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 30 mm x 30 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 50 mm x 75 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 25 mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 50 mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 100 mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE patch (0.9 mm thick) 50 mm x100 mm for outflow tract. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE patch (0.9 mm thick) 100 mm x100 mm for outflow tract. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE patch (0.9 mm thick) 150 mm x150 mm for outflow tract. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester Felt 1.65 mm thick - 150mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE Felts - 1.65 mm thick 12 mm x 100 mm
PTFE Felts - 1.65 mm thick 25 mm x 25 mm
PTFE Felts - 1.65 mm thick 25 mm x 100 mm
PTFE Felts - 1.65 mm thick 25 mm x 150 mm
PTFE Felts - 1.65 mm thick 50 mm x 50 mm
PTFE Felts - 1.65 mm thick 100 mm x 100 mm
PTFE Felts - 1.65 mm thick 150 mm x 150 mm
PTFE Felt with low porosity - 1.85 mm thick - 25 mm x 25 mm (for aortic graft anastamotic line augmentation).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE Felt with low porosity -1.85 mm thick - 100 mmx 100 mm (for aortic graft anastamotic line augmentation).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE Felt with low porosity -1.85 mm thick - 150mm x150 mm (for aortic graft anastamotic line augmentation).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Tissue engineered pericardial patch 4 cm x 4 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic, flexible & ultrathin (2 to 5mm thick) with good suturability with at least 1 year shelf life.
Tissue engineered pericardial patch 6 cm x 6 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic, flexible & ultrathin (2 to 5mm thick) with good suturability with at least 1 year shelf life.
Tissue engineered pericardial patch 8 cm x 8 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic, flexible & ultrathin (2 to 5mm thick) with good suturability with at least 1 year shelf life.
Tissue engineered pericardial patch 10cm x 10 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic, flexible & ultrathin (2 to 5mm thick) with good suturability with at least 1 year shelf life.
PTFE pledgets Thickness x breadth & length : 0.5mm x 3 mm x 3 mm For vascular and cardiac sutures - Specify the number of pledgets in a pack and the rate of the pack clearly. SPR
PTFE pledgets Thickness x breadth & length : 1 mm x 3 mm x 3 mm For vascular and cardiac sutures - Specify the number of pledgets in a pack and the rate of the pack clearly. SPR
PTFE pledgets Thickness x breadth & length :1 mm x 3 mm x 6 mm For vascular and cardiac sutures - Specify the number of pledgets in a pack and the rate of the pack clearly. SPR
PTFE pledgets Thickness x breadth & length : 1.5mm x 3 mm x 3 mm For vascular and cardiac sutures - Specify the number of pledgets in a pack and the rate of the pack clearly. SPR
PTFE pledgets Thickness x breadth & length : 1.5mm x 3 mm x 6 mm For vascular and cardiac sutures - Specify the number of pledgets in a pack and the rate of the pack clearly. SPR
PTFE FELT pledgets Thickness x breadth & length : 1.65 mm x 4.8mm x 6 mm For vascular and cardiac sutures - Specify the number of pledgets in a pack and the rate of the pack clearly. SPR
PTFE FELT pledgets Thickness x breadth & length :1.65 mm x 6 mm x 6 mm For vascular and cardiac sutures - Specify the number of pledgets in a pack and the rate of the pack clearly. SPR
Topical hemostatic : Fibrinogen- human thrombin- aprotinin - in prefilled syringes applicator with a total volume of 10 ml in a pack. SPR
Topical hemostatic : Polythylene glycol - 4 ml for raw surfaces of lung for hemostatic and also for preventing air leak and also preventive usage in cardiac / vascular suture lines
Topical hemostatic - Albumin gluter-aldehyde glue -Total volume of 10ml per pack contained in the prefilled syringes and forming a strong but flexible layer of seal- compatible to fix the separated layers of dissected aorta. To be provided with suitable applicator for focused local application.
Topical bio-absorbable hemostatic: Non-oxidative cellulose 5 x 5 cm - hemostatic acting by non--oxidative chemical reaction using cellulose as a substance.
Tracheal stents (fully covered) - Straight type. Should have radioopaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition
Tracheal stents (fully covered) - Bifurcated Y type Should have radioopaque markers at all the three ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition
Bronchial stents (fully covered) - Straight type. Should have radioopaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition
Thoracic aortic stent grafts - Straight type : To be supplied with the suitable delivery system with smallest possible catheter outer diameter. The stent should be MRI compatible. The purchase will be done as when needed, in which case, a set of various sizes of stents to be brought on the day of surgery and after the usage the rest of the stents can be taken back - i.e consignment mode. The various available sizes and length may be mentioned while quoting. (Size ordered will be based on the patient's condition)
Thoracic aortic stent grafts - Bifurcated Y type : To be supplied with the suitable delivery system with smallest possible catheter outer diameter. The stent should be MRI compatible. The purchase will be done as when needed, in which case, a set of various sizes of stents to be brought on the day of surgery and after the usage the rest of the stents can be taken back - i.e consignment mode. The various available sizes and length may be mentioned while quoting. (Size ordered will be based on the patient's condition)
Sterile Guidewire suitable to fit 16G needle - for Seldinger technique - with minimum length of 50 cm - SPR
Sterile Guidewire suitable to fit 18G needle - for Seldinger technique - with minimum length of 50 cm - SPR
Sterile Guidewire suitable to fit 20G needle - for Seldinger technique - with minimum length of 50 cm - SPR
Sterile Guidewire suitable to fit 22G needle - for Seldinger technique - with minimum length of 50 cm - SPR
Sterile Guidewire - 0.038 inch for femoral vessel cannulation
Femoral puncture needle - 16G - for Seldinger technique - at least 180 -200 cm long. SPR.
CABG drape kit with 9 components: (Totally 15+1 parts in a pack) Go through the link for detailed specifications: https://docs.google.com/document/d/1yOTEiRccpX3apBvgbX438OyfICTzx77sPLQ3Xk4ZapA/edit
General open heart drape kit containing the following components. (Totally 10+1 parts in a pack) Go through the link for detailed specifications: https://docs.google.com/document/d/1_H3eESdoj0TiCagChls5BVnMXGQfF3lW9PTyPavhcKE/edit?usp=sharing
Sternal Wound Dressing Pad - Sterile adhesive polyurethane film with absorbent pad, 20 x 10 cm - SPR
Montogomer T-type Silicon tracheostomy tube - SPR
Double lumen endotracheal tube (DLET) - Left sided- 26F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Left sided- 28F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Left sided- 32F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Left sided- 35F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Left sided- 37F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Left sided- 39F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Left sided- 41F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Right sided- 26F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Right sided- 28F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Right sided- 32F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Right sided- 35F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) -Right sided- 37F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) - Right sided- 39F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Double lumen endotracheal tube (DLET) -Right sided- 41F Transparent Double lumen cuffed endobronchial tube having smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons. (SPR for for any one size)
Endo-bronchial blockers - with balloon - Ardnt type - For one lung ventilation - Wire loop guide and suitable adapter for bronchoscope.
Endo-bronchial blockers - with balloon -Cohen type - For one lung ventilation with flexible defelcting tip with suitable adapter to faciltate bronchoscope.
Endo-bronchial blockers - with balloons - EZ type - with Y-tipped For one lung ventilation
Ultrasonic Nebulizer - SPR for demostration. Or product catalogue brochure with figure to be submitted.
Soft vinyl percussors for performing chest physiotherapy in different sizes
Electro Surgical (cautery) pencils - (electrosurgical electrode) with Long arm - Spatula tip & hand control of twin switch type for cutting and coagulation modes- Should be Compatible with Martin & Alan Cautery (electrosurgical) machines. Prefererable dimensions: shaft diameter less than 2.5 mm. Shaft length -130-140 mm Spatula dimension - about 20 x 2.5 x 0.5 mm Appropraite certification for electrical safety should be confirmed. - SPR
Disposable Microscalpel with high quality micro-blade attached for coronary arteriotomy - SPR
Sterile cover for Echocardio-graphic probe For use in the operative -field. Should fit universally all utrasound probes commonly used during cardiac surgery with special fold to accomdate the probe end without wrinkles. Should be made up of clear transparent latex free medical grade material - polythene. Length of cover - 150 cm; Width of the cover - 10 cm. The kit should also contain securing tapes to hold the cover around the probe and preferably with ultrasound transmission gel - pack.
NON-CONSUMABLES
De bakey Straight Fine Vascular Forceps - Short (18cm) jaw (1.5 x 14mm) 5mm wide shaft
De bakey Straight Fine Vascular Forceps - Medium (25cm) jaw (1.5 x 14mm) 5mm wide shaft
De bakey Straight Fine Vascular Forceps - Long (30cm) jaw (1.5 x 14mm) 5mm wide shaft
De bakey Angled 45º Fine Vascular Fine Forceps - Short (18cm) with smooth jaw (1.5 x 14 mm) & 5mm wide shaft - for IMA dissection
De bakey Angled 45º Fine Vascular Forceps - - Medium (25 cm ) with smooth jaw (1.5 x 14 mm) & 5mm wide shaft - for IMA dissection
De bakey Angled 45º Fine Forceps Vascular - Long (30 cm) with smooth jaw (1.5 x 14 mm) & 5mm wide shaft - for IMA dissection
De bakey Double Action Straight Fine Vascular Forceps - Short (18cm) - with 1x2 teeth - jaw (1.5 x 10mm) 4-5mm wide shaft
De bakey Double Action Straight Fine Vascular Forceps - Medium (25cm) - with 1x2 teeth - jaw (1.5 x 10mm) 4-5mm wide shaft
De bakey Double Action Straight Fine Vascular Forceps - Long (30cm) - with 1x2 teeth - jaw (1.5 x 10mm) 4-5mm wide shaft
De bakey Double Action Straight Vascular Forceps - Short (18cm) with 1x2 teeth- jaw (2.5-2.8 x 12mm) 4-6mm wide shaft
De bakey Double Action Straight Vascular Forceps - Medium (25cm) with 1x2 teeth- jaw (2.5-2.8 x 12mm) 4-6mm wide shaft
De bakey Double Action Straight Vascular Forceps - Long (30cm) with 1x2 teeth- jaw (2.5-2.8 x 12mm) 4-6mm wide shaft
De bakey Double Action Straight Tissue Forceps - Short (18cm) with 1x2 teeth- jaw ( 3 x 14 mm) 4-6mm wide shaft
De bakey Double Action Straight Tissue Forceps - Medium (25cm) with 1x2 teeth- jaw (3 x14mm) 4-6mm wide shaft
De bakey Double Action Straight Tissue Forceps - Long (30cm) with 1x2 teeth- jaw (3 x 14 mm) 4-6mm wide shaft
De bakey Double Action Extra-large Straight Tissue Forceps - Short (18cm) with 3 x2 teeth - jaw ( 5 x 28 mm) 4-6mm wide shaft
De bakey Double Action Extra-large Straight Tissue Forceps - Medium (25 cm) with 3 x2 teeth - jaw ( 5 x 28 mm) 4-6mm wide shaft
De bakey Double Action Extra-large Straight Tissue Forceps - Long (30cm) with 3 x2 teeth - jaw ( 5 x 28 mm) 4-6mm wide shaft
Resano Atruamatic Forceps - Short (18 cm)- Straight jaws -2.5 -3 mm x 14 mm &4-6 mm wide shaft.
Resano Atruamatic Forceps - Medium (25 cm)- Straight jaws -2.5 -3 mm x 14 mm & 4-6 mm wide shaft.
Resano Atruamatic Forceps - long (30 cm)- Straight jaws -2.5 -3 mm x 14 mm & 4-6 mm wide shaft.
Resano Atruamatic Double action Forceps - Short (18 cm)- Straight jaws - 14 mm & 4-6 mm wide shaft.
Resano Atruamatic Double action Forceps -Medium (25 cm)- Straight jaws -14 mm & 4-6 mm wide shaft.
Resano Atruamatic Double action Forceps - Long (30 cm)- Straight jaws 14 mm &4-6 mm wide shaft.
Resano Atruamatic Double action Large Forceps - Short (18 cm)- Straight jaws - 18 mm & 4-6 mm wide shaft.
Resano Atruamatic Double action Large Forceps -Medium (25 cm)- Straight jaws 18 mm & 4-6 mm wide shaft.
Resano Atruamatic Double action Large Forceps - Long (30 cm)- Straight jaws -18 mm & 4-6 mm wide shaft.
Gemini Double Action Diliating, Curved, Smooth Forceps (31-37 cm long) with 1 x 2 teeth, Jaw length - 30 mm, Shaft dia 4-6 mm
Rongeur for Valve - 30º Curved Tip (31-37 cm long) Jaw size - 3.5 mm Shaft dia: 4-6 mm
Rongeur for Valve - Straight Tip (31-37 cm long) Jaw size - 3.5 mm Shaft dia : 4-6 mm
Debakey -Chitwood Aortic Cross Clamp - 30 - 36 cm Jaw size - 120 mm - ( 2 x 3 Teeth)
Debakey -Chitwood Aortic Cross Clamp - 30 - 36 cm Jaw size - 90 mm - ( 2 x 3 Teeth)
Debakey -Chitwood Aortic Cross Clamp - 30 - 36 cm Jaw size - 60 mm - ( 2 x 3 Teeth)
Debakey -Chitwood Aortic Cross Clamp -Slim - 30 - 36 cm Jaw size - 120 mm - (1 x 2 Teeth)
Debakey -Chitwood Aortic Cross Clamp -Slim 30 - 36 cm Jaw size - 90 mm - ( 1 x 2 Teeth)
Debakey -Chitwood Aortic Cross Clamp - Slim 30 - 36 cm Jaw size - 60 mm - ( 1 x 2 Teeth)
Cosgrove type flexible shaft aortic/ vascular atrumatic Clamp - Fogarty type 18 inches long with straight jaw (30-35 mm) with insert.
Cosgrove type flexible shaft aortic/ vascular atrumatic Clamp - Fogarty type - 18 inches long with straight jaw (60-65 mm) with inserts.
Cosgrove type flexible shaft aortic/ vascular atrumatic Clamp - Fogarty type 18 inches long with straight jaw (85-90 mm) with inserts.
Nerve or Vessel Hook - Ball tip Total length : 32-37 cm with working length -23 cm Tip length : 10 mm
Nerve or Vessel Hook- Fine tip Total length : 32-37 cm with working length -23 cm Tip size : 1 x 6 mm
Nerve or Vessel Hook Standard tip Total length : 32-37 cm with working length -23 cm Jaw Size: 2 x 10 mm
Nerve or Vessel Hook - 90º with fine tip. Total length : 32-37 cm with working length -24-28 cm Jaw length : 4-7 mm
Jacobson microscissors 25º - round handle -16 to 20 cm
Jacobson microscissors 45º - round handle -16 to 20 cm
Jacobson microscissors 60º - round handle -16 to 20 cm
Jacobson microscissors 90º - round handle -16 to 20 cm
Jacobson microscissors 125º - round handle -16 to 20 cm
Potts / Potts Smith / Diethrich-Potts Scissors 25º - (16 to 20 cm)
Potts / Potts Smith / Diethrich-Potts Scissors 45º - (16 to 20 cm)
Potts / Potts Smith / Diethrich-Potts Scissors 60º - (16 to 20 cm)
Potts / Potts Smith / Diethrich-Potts Scissors 90º - (16 to 20 cm)
Potts / Potts Smith / Diethrich-Potts Scissors 125º- (16 to 20 cm)
Iris scissors - ring handle with fine straight tips -10 to 12 cm
Iris scissors - round handle with fine straight tips -10 to 12 cm
DeBakey Scissors 25º - (16 to 20 cm) - Ring handle
DeBakey Scissors 45º - (16 to 20 cm) - Ring handle
DeBakey Scissors 60º - (16 to 20 cm) - Ring handle
DeBakey Scissors 90º - (16 to 20 cm) - Ring handle
DeBakey Scissors 125º - (16 to 20 cm) - Ring handle
Favaloro vascular scissors 125º - (16 to 20 cm) - Ring handle
Metzenbaum Scissors (Standard) 16-20 cm - curved blades - ring handle
Metzenbaum Scissors (Long) 20-25 cm - curved blades - ring handle
Metzenbaum Scissors (Extra-long) 30-32 cm - curved blades - ring handle
Mayo scissors - Straight round - standard - 17-20 cm
Mayo scissors - Curved round - standard - 19-23 cm
Mayo-Harrington scissors - straight - 30-32 cm
Wire Cutter - double action -Tungsten carbide edge 17-20 cm
Rib shears (Gluck type)- 18-20 cm
Rib shears (Bethune) - 32-36 cm
Yankauer Suction tube - 28-35 cm
Standard Scalpel Handle - Short 12-14 cm for blade No.10
Standard Scalpel Handle - Short 12-14 cm for blade No.11
Standard Scalpel Handle - Short 12-14 cm for blade No.15
Standard Scalpel Handle - Short 12-14 cm for blade No.23
Standard Scalpel Handle - Long 21-23 cm for blade No.10
Standard Scalpel Handle - Long 21-23 cm for blade No.11
Standard Scalpel Handle - Long 21-23 cm for blade No.15
Standard Scalpel Handle - Long 21-23 cm for blade No.23
Jacobson needle holder - Long (24-25 cm) for 2-0,3-0 & 4-0 sutures with Diamond Coated straight jaws & spring style round handle with ratchet & stream line box lock
Jacobson needle holder - Short (18-20 cm) for 2-0,3-0 & 4-0 sutures with Diamond Coated straight jaws & spring style round handle with ratchet & stream line box lock
Jacobson needle holder - Long (22-24 cm) for 5-0 & 6-0 sutures with Diamond Coated straight jaws & spring style round handle with ratchet & stream line box lock
Jacobson needle holder - Short (18-20 cm) for 5-0 & 6-0 sutures with Diamond Coated straight jaws & spring style round handle with ratchet & stream line box lock
Jacobson micro-needle holder - Long (22-24 cm) for7-0 & 8-0 sutures with Diamond Coated straight jaws & spring style round handle with ratchet & stream line box lock
Jacobson micro-needle holder - Short (18-20 cm) for7-0 & 8-0 sutures with Diamond Coated straight jaws & spring style round handle with ratchet & stream line box lock
Richards Micro Needle Holder -18-20 cm for 6-0, 7-0 &8-0 sutures Diamond coated tip with straight jaws & Ring handle with ratchet
Ryders Needle Holder 18-20 cm for 5-0 sutures with - Diamond coated tip with straight jaws & Ring handle with ratchet
DeBakey Needle Holder 24-25 cm for 5-0 sutures with - Diamond coated tip with straight jaws & Ring handle with ratchet
DeBakey Needle Holder 15-16 cm for 2-0, 3-0 & 4-0 sutures with - Diamond coated tip with straight jaws & Ring handle with ratchet
DeBakey Needle Holder 20-22 cm for 2-0, 3-0 & 4-0 sutures with - Diamond coated tip with straight jaws & Ring handle with ratchet
Hegar vascular needle holder with 1 mm wide jaw - 23-25 cm with Tungsten cardbide edges Ring handle, - with ratchet
Hegar vascular needle holder with 1 mm wide jaw - 20-21 cm with Tungsten cardbide edges Ring handle, - with ratchet
Hegar vascular needle holder with 1 mm wide jaw - 18-19 cm with Tungsten cardbide edges - Ring handle, - with ratchet
Hegar vascular needle holder with 1 mm wide jaw - 14-15 cm with Tungsten cardbide edges - Ring handle, - with ratchet
Titanium Dennis Micro-forceps (straight) - 1 mm ring tip - 18-20 cm counter - balanced Round handle with Diamond coating -
Titanium Dennis Micro-forceps (straight) -pointed platform tip - 18-20 cm - counter-balanced Round handle with Diamond coating -
Titanium Dennis Micro-forceps straight standard 1mm tip 18-20 cm Round handle with Diamond coating
Titanium Gerald Micro-forceps straight ring tip 1mm -18-20 cm - Round handle & Diamond coating
Titanium Gerald Micro-forceps straight platform tip 1mm 18-20 cm - Flat handle & Diamond coating
Titanium Gerald Micro-forceps straight tip 1mm 18-20 cm - with flat handle
Titanium DeBakey Dissection -forceps -straight tip 1mm 18-20 cm -flat handle
Titanium DeBakey Dissection -forceps -straight tip 2 mm 18-20 cm -flat handle
Hegar heavy needly holder - 20 cm with Tungsten Carbide edges - jaw width tapering from 5 mm to 3 mm with jaw length about 20 mm
Heavy & long needle holder - 27 cm with Tungsten Carbide edges - jaw width tapering from 5 mm to 3 mm with jaw length about 20 mm
S.M.MEDICARE
VP Cares
SV SURGITECH PRIVATE LIMITED
Vaishnavisurgicals
QualMed
BHN SURGICALS PVT LTD
ESSKAY AGENCIES
Phoenix Medicos
SRI GA ENTERPRISES
VINAYAK ENTERPRISES
Regency Lifesciences
SHUBHAN ENTERPRISES
LEOMED
B L Lifesciences Pvt. Ltd
Cook India Medical Devices Private Limited
Bard India Healthcare Private Limited
SHRI MANICKAM ENTERPRISES
JK MEDICAL SYSTEMS PVT LTD
Dynamed Equipments
SRI SAI APPA BIOCARE
Chennai Medicco Surgicals
VISIONARY MEDTECH SOLUTIONS PVT LTD
Hubra Pharmaceuticals Pvt Ltd
Texas Medical Systems
KALKI MEDICAL ENTERPRISES
HEBBAR SURGICAL INSTRUMENTS
Syntron Health Care
stage.html
html • 0.12 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .