| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹19.9 L+₹2.9 L (16.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹20.8 L+₹3.8 L (22.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹21.1 L+₹4.1 L (24.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹21.6 L+₹4.6 L (26.9%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
20 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS
GE 881 EWS C/o 56 APO
PROVN OF LORRY FILLING POINT AT BG, SPECIAL REPAIR TO BLDG NO T-41 AND SPECIAL REPAIR OF ELECTRIC FITTING OF BLDG NO T-09 AT JWG UNDER GE 881 EWS
2021_MES_497208_1
GE/PNH-61/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹47,000
Yes
16 Mar 2022
24 Dec 2021
22 Jan 2022
24 Dec 2021
20 Jan 2022
7 Jan 2022
60 days
Amount
B&R PORTION:- Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed.
Dismantling mild steel work of any description complete all as specified and directed.
Demolition of cement concrete ( un reinforced ) in ground floors and paving n exc. 15 cm. thickness, below or above ground level complete all as specified and directed. .
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Taking down chowkhats or frames with shutters n exc 1.5 Sqm (without taking off shutters from frame) complete all as specified and directed.
Taking down chowkhats or frames with shutters exc 1.5 Sqm but n.exc 4 Sqm (without taking off shutters from frame) complete all as specified and directed.
Dismantling or wall/ceiling board (fibre, pulp, insulation, etc) or insulation board.slabs/ blankets, of any thickness, including cover fillets complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified and directed.
S&F Mild Steel rolled section in purlin, main and cross beam, rafter,posts etc. incl connected cleats, hold fasts etc of grade conforming to Fe 410-W (Gde E-250 quality A) complete all as specified and directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S & F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter and similar works fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel & Iron surfaces, width or girth exceeding 10cm & apply two coats of synthetic enamel paint of 1st quality over a coat of red oxide zinc chrome complete all as specified and directed.
S&F 4mm thick E-board(Classic) including fixing of frame work made of special section MS galvanised sheet with zink coating cellular intro painting and consisting of angle cleats of size 25mm wide 1.6mm thick with flag fixing to the ceiling with dash fastner 12.5mm x 40mm long or with 2mm dia GI wire or fixed with bolt in GI channel main 35x25x0.5mm thick and cross runner 25x25x0.5mm for fixing E-board of size 600x600x4mm thick including fixing of E-board with ceiling section and parimeter of channel 25x25x1mm thick,27mm high flange of 20mm to 30mm long extra, complete all as specified and directed.
All as per above Item No 14 above but except ceiling board and frame materials complete all as specified and directed.
M & L for Walling of random rubble, Brought upto course, built in CM 1:6 complete all as specified and directed.
All as per item No 16 above but except stone complete all as specified and directed.
M & L for RCC (Nominal Mix) 1:2:4 type B 1 (20mm graded aggregate) as in beams, cantilevers, bressummers, lintles over 1.50m span and the like complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc.Rough finished surfaces of concrete also splays between floors and beams, etc. complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 20 above but 5mm dia and over upto and incl 10mm dia as in stirrups, spacers and binders complete all as specified and directed.
M&L for Brick work with old size sub class ‘B’ bricks, straight or curved on plan exc. 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed.
M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 50mm thick as in plinth protection finished fair & even laid in alternate bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
M&L for Rendering 20 mm thick in cement mortar 1: 4 on other than fair faces of brick work or stone masonary surfaces, chajja and suspended work finished even and smooth without using extra cement, complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, chajja and suspended work finished even and smooth without using extra cement, complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1: 6 on other than fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement, complete all as specified and directed.
M&L for applying two coats of cement base paint on walls including preparation of new plastered or un-plastered surfaces of wall complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of oil emulsion distemper over a coat of 1mm thick wall putty complete all as specified and directed.
S & F pressed steel frame of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges 100mm long , 03 Nos each for double shutters, lock strike plate etc complete all as specified and directed.
S & F 35 mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board, medium density, wood particle board with commercial face veneered supplied & fitted to chowkat complete all as specified and directed.
S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered or rounded, mitred and rebated shash bars, any numbers, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a), supplied & fitted to chowkats complete all as specified and directed.
S&F Steel window/ ventilator glazed and gauged (combination) with side hung/ top hung shutters incl box type / projecting type hinges, and steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame complete incl necessary cooler arrangement in window & guard bars all as per sample kept at GE Office complete all as specified and directed.
M&L for PCC ,1:3:6 type C1, using 20 mm crushed agg as in bed blocks for embedding hold fast etc. complete all as specified and directed.
S & F 300 mm, mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed.
S & F 50 mm butt hinges, medium weight cold rolled mild steel and fixed, complete all as specified and directed.
S & F 2nd class hard wood for small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labour articles not exc 200 cu.cm each, complete all as specified and directed.
S & F 150mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 150 mm long aluminium handles, cast type, anodised complete all as specified and directed.
S & F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F Sheet glass, ordinary quality, 3mm thick and glazed with oil putty or wooden beads, in square n exc. 0.5 Sq m each pane, complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in sub base and flooring, etc. complete all as specified and directed.
M&L for chequered cement concrete tiles with grey pigment cement and pigments of size 30cmx30cmx25 mm thick,set, jointed and pointed in neat cement surry in floors including 20 mm thick screed bed in CM 1:6 for laying floor tiles complete all as specified and diected.
M&L coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) are of each tile exc 0.11 Sqm but n.exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with & incl 15mm thick screed bed or bedding layer with CM 1:6 complete all as specified and directed.
All as per Item No. 44 above but in vertical surfaces such as skirtings, dados and risers to steps etc including 10 mm thick rending in CM (1:4) complet all as specified and directed.
M&L for cement concrete M-10 (Nominal mix) type C-1 using 20mm graded aggregate as in surface channel and drain complete all as specified and directed.
M & L for 75mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate , as in sub base. complete all as specified and as directed by the Engineer-in-Charge
S&F in repair 25mm dia MS powder coated tublar curtain rod, fancy type, complete all as specified and directed.
S&F MS powder colour coated, decorative type knobs with bracket of fixing at end of pelmet rod suitable for 25mm dia, complete all as specified and directed.
M&L for Complete removal of existing treatment and applying two coat of cement base paint on wall (any tint) on walls complete all as specified and directed.
M&L for Complete removal of existing treatment and applying two coat of oil bound distemper (any tint) on walls complete all as specified and directed.
M&L for Preparation of wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
E&M PORTION:- Supply and laying pipe galvanized, “Medium class”, 50 mm dia complete with all fittings laid in trenches complete all as specified and directed.
S&F 4" stainless steel water filled Borewell submersible pump set complete 3 HP(2.2 KW) ,9 stage,head range from 18 to 53 mtr with MS Clamp of suitable size with nut,bolt and washer and foundation complete all as specified and directed by Engr -in- charge. Make: Crompton ,Model no 4CSSF8-3009(3PH) or equivalent make KSB/Kirloskar
S&F pump control panel (starter panel)suitable for 4"sumersible pump 3 HP three phase 415 v complete all as specified and directed.
Supply and fix flat submersible cable of size 10 sqmm 3 core complete all as specified and directed.
S & F NRV of size 50 mm all as per IS 1538, ISI marked, with all fitting complete all as specified and directed by Engr-In-Charge. Make-Kirloskar/Jindal/Upadhay.
S & F gun metal gate or globe valve with iron wheel head, screwed both ends for iron pipe and fixed of size 50 mm ISI marked, with all fitting complete all as specified and directed by Engr-In-Charge. Make-Kirloskar/Jindal/Upadhay.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L for rendering 10mm thick on brick wall or concrete surface in cement mortar 1:4 finished fair and even complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed.
Removal of excavated soil not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M&L for Approved quality clean dry sharp sand as in cushioning to under ground cable laying 15cm thick before laying and 8cm after laying the cable in trenches for cable cushioning, complete all as specified and directed.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Design, supplying, installing, testing and commissioning LT outdoor type panel board factory fabricated cubical kiosk type whether vermin proof with locking arrangement and made out of MS sheet 3.15 mm thick suitable size of channel for base complete with 100 Amps rated copper bus bar chamber and cabinet for housing mounting switch disconnection fuze unit metering eqpt prewired with suitable size of copper conductor and duly painted with one coat of red oxide paint and two coat of synthetic enamel paint power coating mounted on PCC (1:4:8) platform commissioning washer chamber and panel board fixing an angle iron frame which is made out of 40 x 40 x 6 mm thick angle iron duly marked the incoming outgoing controls and comprising complete all as specified and directed with the following:- (a) MCCB 63 Amps capacity 25 KA 4P, 415V--01 Nos(incoming) (b) MCB SPN 40 Amp-03 Nos (outgoing) , (c) change over on load 100 amp -1 No (d) one set indicator lamp for R, Y & B for each incoming
M&L for earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 25 x 4 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv main switch / DBs alongwith MCBs any type / capacity and making good disturbed surface to match with the existing surface, complete all as specified and directed.
Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc for one light/ bell point controlled by one way switch 6 Amp complete all as specified and as directed.
All as per item No 71 above but one fan point (Ceiling and exhaust) controlled by one way switch 6 Amp complete all as specified and directed.
All as per item No 71 above but one 5 pin, 6 Amp socket outlet on the same board complete all as specified and directed.
All as per item No 71 above but one 5 pin, 6 Amp socket outlet on the independent board complete all as specified and directed.
All as per srl item No 71 above but for one 3 pin socket outlet 15 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 1.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair Ceiling rose, 3 phase PVC/poly carbonate, insulated body, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 6 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket outlet multipurpose combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Tube light fitting box type suitable for LED 20W tube rod made out of ultra bright, glass shell, glare free, wide angle, single side connection retofit LED tube with G13 lamp holders complete with hosing with all accessories pre wired and making connection with copper flexible cable of appropriate size from ceiling rose to light fitting including 20LED tube rod 4 feet long with single side connection complete all as specified and directed. Make:-Havells Cat Part No:-LHLDEFXD5L8R020 for LED tube rod & Cat Part No:-LHFXCEP1TNNW020 for batten fittings or Equivalent cat part of make as specified in PS. Note :- The LED batten and LED tube rod shall be of same make.
S&F in repair LED street light fittings 35W made up of pressure die cast aluminium housing LED Energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Deviceas lighting source seperate driver compartment with IP66 protection complete with hosing with all accessories pre wired with and including 40mm dia GI pipe bracket of 1.2 mtr made to shape as required fixed on wall or pole with FI clamp of required shap & 40x6mm siize, nut, bolts, washers and making connection with three core copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:- ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC or Equivalent cat part of Make specified in PS
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:- Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make as specified in P.S.
S&F MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
Supply, laying and testing of cable in trenches/ poles XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 2 core 16 sqmm including taking down complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F in repair LED luminaire 600mmx600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light, complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F Sub main wiring with single core cable 2x 4 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 4 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note:-2 wire of 4 sqmm, 1 wire of 4 sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
SUNIL KUMAR SANGEET KUMAR AND SONS
M/S NARAYAN CONSTRUCTION
M/S KABIR CHOUDHARY
Modh Hafiz Khan
BALVINDER SINGH AND SONS
M/S BADRI NATH GUPTA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .