Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-Finance 56 LAKSHMANPUR COLONY ALLAHABAD ROAD SULTANPUR | SULTANPUR | SULTANPUR | UTTAR PRADESH | ₹48.0 L | L1 | Accepted-Finance L1 |
| 2 | L2₹51.7 LRejected-Finance | ₹51.7 L | L2 | Rejected-Finance L2 |
| 3 | L3₹55.3 LRejected-Finance 10 118 INDIRA NAGAR DISTT LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | ₹55.3 L | L3 | Rejected-Finance L3 |
Tender Value
₹75.6 L
EMD Value
₹5.8 L
Closing Date
30 Jan 2026, 12:00 pmClosed
SE LKO CIR PWD LKO
SE LKO CIR PWD LKO
Repair work of the bridge constructed on the Gauda Moazzamnagar road from Lucknow-Haradoi road in Lucknow district
2026_CEUCZ_1107131_1
179/523(2)C-Lko.Cir/2025-26 Dated 08.01.2026
Open Tender
Civil Works - Bridges
60 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,714
₹5.8 L
SE LKO CIR PWD LKO
5 Feb 2026
17 Jan 2026
30 Jan 2026
17 Jan 2026
30 Jan 2026
17 Jan 2026
21 Jan 2026
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.1. (Excluding G.S.T.)
Construction of subgrade with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 complete in all respects.(Including all material, labour & T&P. (Excluding G.S.T.)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soll and disposal of surplus excavated soll as directed, within a lead of 50 m.including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the all kind of soil as per S.I. No. 2.8.1. (Excluding G.S.T.)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm (nominal size)) as per S.I. No. 4.1.6. (Excluding G.S.T.)
Providing and laying reinforced cement concrete M 25 grade in superstructure as per drawing and technical specifications clauses 800, 1205.4 and 1205.5. (Excluding G.S.T.)
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. (Excluding G.S.T.)
Re-Laying on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per MORT&H Specification No. 2504 (40-65 kg. Kabrai Boulder). (Excluding G.S.T.)
Providing and laying on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per MORT&H Specification No. 2504 (40-65 kg. Kabrai Boulder). (Excluding G.S.T.)
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811. (Excluding G.S.T.)
Finishing walls with Premium Acrylic Smooth Exterior paint with silicone additives of required shade : new work (Two or more coat applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) (ace Adv. Walmasala), apex Ultima, weather coat all guard) asian, berger. as per SOR No. 13.47.1. (Excluding G.S.T.)
Replacement of Expansion Joints complete as per drawings. (Excluding G.S.T.)
Providing and laying of an elastomeric slab steel expansion joint, catering to right or skew (less than 20 deg., moderately curved with maximum horizontal movement upto 50 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation and clause 2605 of MoRTH specifications for road & bridge works. (Excluding G.S.T.)
Laying brick soling on prepared sub-grade with brick on end edging according to lines,graded and cross-section shown on the drawing filling joints with sand and earth,spreading 25 mm thick layer of earth over brick soling,watering and rolling the same with three wheeled road roller 80-100 kN as per Technical Specification Clause 412. (Excluding G.S.T.)
Providing and laying of hot applied thermoplastic compound 2.5mm. Thick including reflectorising glass beads @ 125 gms per sqm area, thickness of 2.5 mm. is exclusive of surface applied glass beads as per IRC: 35. The finished surface to be level, uniform and free from streaks and holes. (Excluding G.S.T.)
Providing and laying of hot applied thermoplastic compound 5mm. Thick (Transfer Bar) including reflectorising glass beads @ 250 gms per sqm area, thickness of 5 mm. is exclusive of surface applied glass beads as per IRC: 35. The finished surface to be level, uniform and free from streaks and holes. (Excluding G.S.T.)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground lvel as per approved drawing. HAZARD MARKER (Excluding G.S.T.)
CHEVRON 50x60 Cm (Excluding G.S.T.)
Accidental Caution Board (90 cm high octagon)(Excluding G.S.T.)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 6.18 MB
Tendernotice_2.pdf
PDF • 1.41 MB
BOQ_2042944.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid