Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC PLOT NO 26 1ST FLOOR PRATAP NAGAR NEAR JAIL ROAD NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹1.1 Cr | L1 | Accepted-AOC BEING L1 BIDDER |
| 2 | L2₹1.1 Cr+₹6.0 L (5.68%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹1.1 Cr+₹6.0 L (5.68%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹1.1 Cr+₹7.7 L (7.30%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹1.1 Cr+₹7.7 L (7.30%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹1.2 Cr+₹9.4 L (8.92%)Rejected-Finance B 101 3RD FLOOR JHILMI COLONY DELHI 110095 | DELHI | EAST DELHI | DELHI | 110095 | ₹1.2 Cr+₹9.4 L (8.92%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹1.2 Cr+₹18.8 L (17.7%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹1.2 Cr+₹18.8 L (17.7%) | L5 | Rejected-Finance Other than L1 bidder |
| Sl No | Description | Qty | Unit | Shivam Firetech Engineers L1 | imran construction company L3 | M/S Chhavi Constructions Co L5 | Commercial Traders L2 | BEHAL TRADERS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles all as specified. | 10 | Cum | 100 ₹1,000 Lowest | 100 ₹1,000 Lowest | 200 ₹2,000 | 999 ₹9,990 | 150 ₹1,500 |
| 2.00 | M&L for brick work with sub class 'B' Bricks (using old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and as directed. | 10 | Cum | 4,000 ₹40,000 | 3,800 ₹38,000 | 3,000 ₹30,000 | 2,000 ₹20,000 Lowest | 4,800 ₹48,000 |
| 3.00 | Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed. | 1,720 | Sqm | 8 ₹13,760 Lowest | 10 ₹17,200 | 10 ₹17,200 | 10.99 ₹18,902.8 | 10 ₹17,200 |
| 4.00 | M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in CM 1:4, finished even and fair without using extra cement, complete all as specified & directed. | 970 | Sqm | 140 ₹1,35,800 | 215 ₹2,08,550 | 150 ₹1,45,500 | 60.99 ₹59,160.3 Lowest | 175 ₹1,69,750 |
| 5.00 | M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in CM 1:6, finished even and fair without using extra cement, complete all as specified & directed. | 500 | Sqm | 130 ₹65,000 | 190 ₹95,000 | 150 ₹75,000 | 60.99 ₹30,495 Lowest | 160 ₹80,000 |
| 6.00 | Ready mix plastering mortar solution
Base coat (minimum 5mm thickness or as per manufacturers instruction) applying finishing with water vapour permeable mortar, basecoat render for weather resistant & high performance façades with csv compressive strength. Flexural strength 22.5 n/mm2 and water vapour permeability 115 as per EN 998-1. The system includes the reinforcement of weaker points/areas (change in the substrate material, slabs. pillars. roller blind boxes. around the openings/windows, doors, etc.), with fibre glass mesh to avoid cracks as per manufacturer's recommendations. Top coat (final finishing work) (minimum 10mm thickness or as per manufacturers instruction) finishing with the rainwater resistant and water vapour permeable coats rendering mortar, render applied in two for rainproof/weather resistant & decorative facades with a csi compressive strength class, flexural strength ≥ 2.5 n/mm2 resistance to water absorption as W2 (c≤0.2 kg/m2.mino.5), water vapour permeability ≤ 15 as per EN 998-1. The system includes the reinforcement of weaker points/areas (change in the substrate material slabs. Pillars, roller blind boxes, around the openings/windows, doors. etc.), with fibre glass mesh to avoid cracks as per manufacturer's recommendations. The color of the plaster to be selected by GE | 200 | Sqm | 250 ₹50,000 | 350 ₹70,000 | 150 ₹30,000 Lowest | 300 ₹60,000 | 1,300 ₹2,60,000 |
| 7.00 | M&L for rendering 10 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling, including finishing the surface even and fair without using extra cement complete all as specified. | 100 | Sqm | 150 ₹15,000 | 235 ₹23,500 | 150 ₹15,000 | 300.99 ₹30,099 | 125 ₹12,500 Lowest |
| 8.00 | M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of wall and making the surface even & smooth for receiving distemper/ paint of any description, complete all as specified & directed. | 3,800 | Sqm | 14 ₹53,200 Lowest | 25 ₹95,000 | 50 ₹1,90,000 | 50.99 ₹1,93,762 | 40 ₹1,52,000 |
| 9.00 | M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of ceiling and making the surface even & smooth for receiving distemper / paint of any description, complete all as specified & directed. | 1,400 | Sqm | 15 ₹21,000 Lowest | 20 ₹28,000 | 50 ₹70,000 | 50.99 ₹71,386 | 40 ₹56,000 |
| 10.00 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed. | 970 | Sqm | 28 ₹27,160 Lowest | 55 ₹53,350 | 50 ₹48,500 | 50.99 ₹49,460.3 | 40 ₹38,800 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
10 Feb 2026, 6:00 pmClosed
CWE NEW DELHI
HQ CWE NEW DELHI
SPECIAL REPAIR TO BLDG NO P-101 KG SCHOOL AT AHRR UNDER GE EM RR HOSP DELHI CANTT-1
2026_MES_748614_1
CWE-ND/55/2025-26
Open Tender
Civil Works - Others
Item Rate
245 days
DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE E/M RR HOSP DELHI CANTT
₹2.2 L
16 Apr 2026
15 Jan 2026
12 Feb 2026
15 Jan 2026
10 Feb 2026
5 Feb 2026
Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles all as specified.
M&L for brick work with sub class 'B' Bricks (using old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in CM 1:4, finished even and fair without using extra cement, complete all as specified & directed.
M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in CM 1:6, finished even and fair without using extra cement, complete all as specified & directed.
M&L for Ready mix plastering mortar in two coats of overall thickness 15mm and minimum top coat of 10mm thick and the plaster has to be done through manufacturer/applicator complete all as specified & directed. Note-: plaster has to be done from plinth level to first floor roof beam.
M&L for rendering 10 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling, including finishing the surface even and fair without using extra cement complete all as specified.
M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of wall and making the surface even & smooth for receiving distemper/ paint of any description, complete all as specified & directed.
M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of ceiling and making the surface even & smooth for receiving distemper / paint of any description, complete all as specified & directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior grade weather proof paint over a coat of weather resistant acrylic primer, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper, complete all as specified and as directed.
M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed.
M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of exterior grade weather proof paint, complete all as specified and directed.
M&L for complete removal of existing treatment on old plastered surfaces of ceiling and applying two coats of oil bound distemper, complete all as specified and as directed.
Demolition floor, hearth or wall tiling including cement mortar bedding (including backing) and rubbish off the premises, complete all as specified & directed.
M&L 15mm thick screed bed or bedding layer in cement mortar (1:4) for laying floor finishes, complete all as specified & directed.
M&L 10 mm thick screed bed or bedding layer in cement mortar (1:3) to receive wall tiles, complete all as specified & directed.
M&L for non skid colour ceramic tiles 7-8 mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11Sqm, in floors etc, set jointed in neat cement slurry & pointed in coloured cement to match complete all as specified and directed.
M&L for Matt finished full body Vitrified tiles with spacer(mini 1.50mm),8 to9 mm thick (square/ rectangular), area of each tiles exceeding 0.36 sqm but not exceeding 0.72 sqm, in floors/skirting etc. set and jointed with type -II (floor) tiles Adhesive of 6 to 8 mm thick, and pointed in white or coloured grouting to match) complete all as specified and directed.
M&L for vitrified ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm on vertical surfaces such as dado/ skirting etc, set and jointed with type - II (wall) tiles Adhesive of 6 to 8 mm thick, and pointed in white or coloured grouting to match, complete all as specified & directed.
M&L for coloured glazed ceramic wall tiles as in vertical surfaces of size 600mm x 300mm x 7 to 8 mm thick, set and jointed with type - II (wall) tiles Adhesive of 6 to 8mm thick and pointed in white or colour grouting to match, complete all as specified & directed.
M&L for 25mm thick PCC 1:2:4 TYPE B0 using 12.5mm graded stone aggregate in sub baseof floor complete all as spd and directed.
Material and labour for pre-polished coloured chequered cement concrete tiles 300mm X 300mm X 18-20 mm thick, with white cement and pigments, set, jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6 including demolition of tiles complete all as specified and directed.
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area not exc 1.50 Sqm each, complete all as specified.
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area exc 1.50 Sqm but n.exc 4.00 sqm each, complete all as specified.
S&F in repairs vitreous china urinal flat back Large: top inlet, of white colour of size 390mmx400mmx590mm, including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and incl 60 mm long brass screws, pointing around urinal back in cement, complete all as specified and directed.
S&F in repairs urinal spreader of brass CP any colour for fixing with 15 mm dia pipe (minimum weight 60gms), complete all as specified.
S&F Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick with 5mm thick transparent toughened glass view panel of size 300X500mm ,comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. ( Glass measured and paid seperately)
S&F 5 mm Thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape,drilling holes required.
S&F in repairs urinal partition plate of white colour of size 145mmx310mmx700mm, complete all as specified.
Providing and fixing factory made upvc white colour sliding window three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh sash (42mm x 57mm), sliding interlock (one vertical length in each shutters) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2(+-0.2)mm thick galvanised steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile. Frame will be fixed to the wall with 8mm x 100mm long fasteners, hardware (touch lock of zinc alloyed (white powder coated), steel roller system. incl stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, 5.5mm thick glass, rubber bedding etc and other required accessories all as specified and directed.
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified & directed.
S&F 100 mm long butt hinges, medium weight, cold rolled stainless steel and fixed, complete all as specified.
S&F 100 mm long, stainless steel barrel tower bolts of extruded section complete all as specified and directed.
S&F 100mm size extruded Stainless steel handles, fabricated type complete all as specified and directed.
S&F stainless steel, sliding door bolt 300mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections, complete all as specified & directed.
S&F 150 mm long, stainless steel barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long stainless steel handle of extruded section fabricated type anodised and fixed, complete all as specified and directed.
S&F in repair mild steel ordinary rat tail rod pattern springs including roller and roller plate complete 300mm length, complete all as specified and directed.
S&F in repairs stainless steel curtain rod 20-22mm dia and thickness of rod 1.00mm including brackets, side knobs etc, fixed to walls, complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length 140mm, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors etc laid, bedded and pointed in any mortar, complete all as specified & directed.
M&L for 18-20mm thick granite with top surface flamed finish with polished (anti skid texture) of any type in floors in cement mortar (1:6) jointing shall be filled with matching grout including 15mm thick screed bed or bedding layer in CM 1:6, exposed edge shall also be flamed or chamfered as per site requirement complete all as specified & directed by Engr-in-Charge.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified & directed.
M&L for machine cut Kota stone slab 20 to 25 mm thick as in treads, risers of staicase laid over cement screed base and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including cement screed bed 20 mm thick in cement mortar 1:4 complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, complete all as specified & directed.
All as per ser item No. 47 here-in-before but 25mm bore.
Supplying and laying of CPVC pipe 20mm dia SDR 11 and plain CPVC SDR 11 brass fittings on walls/ceilings or laying in floors including all necessary fittings complete all as specified.
All as per ser item No. 49 here-in-before but 25mm bore.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc, complete all as specified & directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or floors, complete all as specified & directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls, complete all as specified & directed.
M&L for PVC floor trap of 110mm dia of outlet, plain with grating including jointing with solvent cement, including embedding with PCC 1:2:4 type B-1, complete all as specified & directed.
S&F 110mm bore PVC (SWR) bends any radius, complete all as specified & directed.
S&F in repair white vitreous china wash hand basin (flat back) of size 550 x 400 mm fixed on and including new brackets complete including 32 mm size brass chromium plated waste coupling, etc, complete all as specified and directed.
S&F in repair of white colour,European vitretious china wash down water closet pan(wall mounted composite pattern) fancy type incl builtin vitreous china flushing cistern dual flush type of capacity 9-10 ltrs incl pvc white seat cover complete all as spd and directed.
S&F in repairs PVC low level flushing cistern, valve less, Syphonic action type, double push bottom, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection complete all as specified.
S&F in repairs bib taps, cast copper alloy, fancy type, with crutch or butterfly handle, chromium plated, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed.
S&F in repairs stop valves/angle valve, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type), with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm, all as specified & directed.
S&F in repair tubular towel rail stainless steel chromium plated 20 mm dia D type 60 cm long between flanges, including brackets and fixed to walls, all as specified and as directed.
S&F in repairs soap dish, brass CP any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed.
S&F in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 440 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed..
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes coupling; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified & directed.
S&F waste coupling of PTMT (half or full threaded), minimum weight 60gms, suitable for discharge pipe of 40mm bore dia, complete all as specified & directed.all as specified.
S&F in repairs kitchen plate rack made of stainless steel 1 mm thick with plugs washers as overall size of 75cm x 75 cm including fixing to wall and all accessories, complete all as specified and directed
Supply and fix in repair 1000 litres capacity double layer, rotational molded, polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe including dismantling tank, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified.
M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) of any description and as in kitchen slabs, shelves, chimney, Chajjas etc not other specifically provided for complete all as specified and directed.
M&L of RCC of nominal mix type B0 1:2:4 (12.5mm graded aggreate) as in chajjas and like all as spd and directed by Engr-in-charge.
S&F in repair brass CP for sink & washbasin mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified.
S&F in repairs 20mm bore of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to pipe all as spd and directed.
S&F factory made 18mm thick 100% solid WPC(Wood Polymer Composite) laminated board of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge.
M&L for followings :-(i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible)(iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)(iv) Cleaning exposed concrete substrate by using water jet.(v) Removing visible rust along the length of reinforcement using hand tools as approved.(The Engr-in-charge may order sand blasting if rust is approved)(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to bars :-(i) cleaning of all exposed bars (new & old) alround(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris and dust (ii) Applying Epoxy bond coat on the sound substrate using approved apray machine & ensuring that no pin holes are visible (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitoius mortar) of 25-50mm thickness. Note : Application of PMM sghall of preferably be in coats of approx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed within 30mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer cmplete all as specified and directed.
S&F in repair 100mm dia cast iron (spun cast) soil, waste and vent pipes in any length, with or without ears, with lead joints, fixed to walls including dismantling old pipes any type complete all as specified and directed.
S&F in repair 100 mm dia cast iron cowl for spun pipes (any radious) with polymer jointing materials, complete all as specified and directed.
S&F in repair 100 mm dia cast iron bends/Tee with oval access doors for spun pipes (any radious) with polymer jointing materials, complete all as specified and directed.
Demolition of cement concrete (unreinforced)/lime concrete/sunken floor of any description and in any position not otherwise specifically provided for by mechanical means (like drill machine, Hilti, pneumatic chisel, etc) complete all as spd & directed.
M&L PCC 1:3:6 Type C1 (using 20 mm graded stone aggregate ) in mass concrete for sunken portion of WC, complete all as specified and directed.
M & L for Water proofing treatment of sunken RCC slab : (i) 15mm thick plater in CM (1:3) mixed with WP compound as per manufacturer's instructions shall be provided on sunken portion while the concrete is green. (ii) Apply cement slury @ 0.488 kg/sqm cement mixed with Acrylic based polymer modified cementious composite compound @ 0.253 kg/sqm and the surface will be allowed to air cure for 4 hours. (iii) Apply another layer of cement slurry @ 0.242 kg/sqm of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.126 kg/sqm and the surface will be allowed to air cure for 4 hrs. (Make of cement composite compound of Dr. Fixit/Fosroc/Sikka) (iv) Curing the sunken portion with water minimum for 7 days by ponding. (v) Paste 200micron thick poythene film of approved make with approved adhesives to the treated sunken surface. (vi) Joints/Traps/WC/Soil pies shall be properly sealed with approved sealing compound of approved make. (vii) Testing of all traps & joints shall be done after sealing and before filling of sunken slabs and ponding test for 96 hours. (viii) Spout pipe shall be provided for drain out the water in sunken portion. Note : Flat surface shall be measured for payment.
M&L for TMT bars 6 to 8mm dia cut to length bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance indimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F in repairs Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as spd and directed
M&L for Preparation of new or previously untreated steel surfaces of any description not otherwise described over 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S&F of SS auto closing hinges openable at 0 degree for kitchen cabinet shutters and bed room cub boards complete all as specified.
S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified.
S&F Grating doom 100mm dia of SS (Minimum weight 35gms) all as spd and directed by Engg-in-Charge.
S&F in repairs 32mm Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as spd and directed.
M& L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as spd and directed.
M&L for Formwork tochullah hoods, chajjas, troughs and similar items including edges and fair finished all as spd and directed
M&L for Drilling & chemical anchoring of new rebars/stirrups :-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-8 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item).
M&L for Drilling & chemical anchoring of new rebars :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 16 & 20 mm dia bar - drilling length 160 to 180 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item).
Supply & fixing 12 mm dia steel sheer connector in grid pattern in between old core and new concrete as wherever directed by Engr-in-charge and as specified by manufacturer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA). ( The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item) complete all as specified and directed.
M&L for chipping of spalled and loose concrete and cleaning rust from reinforcement by sand blasting scrubing down concrete surfaces with wire brushes cleaning with water allow to dry and applying a layer of Zinc rich epoxy primer as an anti rust on all exposed reinforcement followed by a layer of binding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited and applying two layers of guniting over steel welded mesh 2mm dia of wire and aperture 75mm. Total thickness of guniting not exc 40mm (Avg thickness) in cement mortar 1:2 using OPC 53 grade cement mixed with polycreate mixture @ 2% by weight of cement or as per manufacturer's instruction and finally applying cement plaster over guniting surface of required thickness to give even, uniform and smooth finishes confirming to proper geometrics in cement mortar 1:3 to match the existing surfaces as in sides, soffits of the slabs, chajjas, fins, facias, parapets, linetls, columns and beams etc complete including necessary scafolding, shuttering, chasing to brick work or RCC members at any height upto 6 storied buildings including removal of all small trees/ shrubs etc , complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving n exc 15 cm thickness (below or above ground level), complete all as specified & directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates), as in foundation, complete all as specified and directed .
Dismantling mild steel work of any description not otherwise provided for, complete all as specified and directed.
M&L for rolled mild steel section as in roof trusses (framed), trussed, purlins, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410- W (Gde- E-250) quality-B, complete all as specified and directed.
M&L for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe-410-W (Gde-E-250) quality B, all as specified and as directed.
Supplying, fabricating & fixing in aluminium door shutters with powder coating (minimum thickness of powder coating 50 micron), vertical stile of door shutter of size 85mm x 44.45mm x 1.5mm thick, top, middle and bottom rail of size 85mm x 44.45mm x 1.5mm thick and fixing ACP sheet with aluminium beading and rubber gasket/ beading\ screws as directed. Three nos. aluminium hinges of size 100mm and two alumium tower bolts of 150mm size & 01 no. door hadnle 150mm for each shutter fixed, complete all as specified and directed by Engr-in-Charge. (Cost of ACP sheet shall deemed to be included in the rate qouted for this item).
S&F in repairs pillar taps, cast copper alloy, fancy type, chromium plated with capstean head screwed down, high pressure with or without lettered hot or cold with long screwed shames and fly nuts, screwed for 15mm bore pipe, complete all as specified & directed.
M&L for providing cement concrete 1:2:4 type B-I (20mm graded agg) in roof kerb or mud slops, rounded or chamfered on edges, coping, kneelers, kerb water tough and the like incl weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified & directed.
M&L applying bees wax polish on existing kota stone surface all as spd and directed
Supplying and Fixing of unplasticised poly vinyl chloride (UPVC) openable window with openable shutters duly manufactured using UPVC reinforced profiles (composition of profile shall consists a minimum of 5.5 phr of TiO2 and not more than 12 phr of CaCO3 for every 100 parts of PVC resin) of 88 mm x 55mm x 2.40 mm,60 mm x 55 mm x 2.40 mm for outer frames, 60 mm x 74 mm x 2.40 mm for mullion sections as per the need and 60 mm x 75 mm x 2.40 mm for openable shutter frame capable of mounting single glazing system structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.2 mm prefabricated & welded through fusion welding the door sash shall be fitted with 5 mm thick clear float glass of reputed make duly fixed with grey colour TPV gaskets for sash & glazing bead shall be coextruded with grey colour soft PVC. System shall be provided standard hardware, single point locking using cockspur handle and friction stays. and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc
Dismantling asbestos cement (corrugated, semicorrugated etc.) sheets in roof coverings etc complete all as specified and as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in lroof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F in replacement toughned glass 12mm thick as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required, edges rounded and etching works etc and all kind of stainless steel patch fitting & fixtures, spider patch etc, complete all as specifed and directed.
S&F stainless steel handle 450mm long fixed to 12mm thick toughned glass door with and including all fixing accessories i.e. bolt, washer, adhesive etc, complete all as specifed and directed.
S&F stainless steel door lock, glass to glass type, suitable for 12mm frameless toughned glass door with and including all fixing accessories i.e. bolt, washer, screws, adhesive etc, complete all as specifed and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, fillets etc, and removal of debries from site, complete all as specified and directed.
S&F louvers fabricated with PVC Panelling 20-25mm thick factory made rigid extruded hollow section panels, tongue and groove type,fixed in anodised alm/upvc frame with necessary fixing arrangements,screws and accessories incl cutting to required size making good complete all as specified.
Providing & fixing false ceiling with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of semi perforated12mm Size 595 x 595 mm of approved texture, 12mm thick thick micro tegular design and patterns having moisture micro tegular edged or 1 0 mm content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm.size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-
M&L for ceramic high depth Elevation tiles for vertical surfaces of size 300X 450mm set and joint with tiles Adhesive of 6 to 8 mm thick type-II(wall) ,all as specified and as directed.
M & L in replacement for point wiring of concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates.
(a) One light/fan/bell/exhaust fan point controlled by one switch.
(b) One 3 Pin socket outlet 5 Amps on Independent board.
(c) One 3 Pin socket outlet 5 Amps on same board.
All as per srl item No. 120 here in before but point wiring for one light point controlled by two Nos of two way switches
All as per srl item No. 120 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.
M and L in replacement for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in existing conduit including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including modular MS sunken box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/fan/exhaust point controlled by one, one way switch 06 Amps complete all as directed. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws, as applicable will be included in quoted rates.
All as per srl item No. 123 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board.
All as per srl item No. 123 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board.
All as per srl item no. 123 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point on Independent board.
S & F Modular Switch 1 way 16 A, 1 Module
S & F Modular Socket 6 / 16 A - 2/3 Pin combined 2 module
S & F Modular Switch 1 way 6 /10 A, 1 Module
S & F Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module
S&F in repair modular switch, 06 amps two way,SP,one module 230 volts AC complete all as specified and directed.
S & F Modular fan regulator step type, 30W, 2 Module suitable for BLDC fan complete all as specified and directed.
S & F of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed.
Supply and fix in replacement of MCB protected modular AC/Geyser box complete with and including 6 pin socket, plug top, modular cover plate, mini MCB SP 20 Amp capacity and PVC gang box etc, complete all as specified and directed by by Engineer-in charge.
Supply of surface/wall mounted 20W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP40 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 110 lumen/watt.The LED batten with micro wave sensors for movement detection, with factory set dimming profiles of 50% and 100%, light dims to these levels in case occupacy is not detected. The electronic driver used shall have a power factor ≥0.95 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from 0⁰ to 50⁰C. The luminaire shall pass electric strength test. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make/manufacturer as that of LED luminaires. Manufacturer shall have inhouse lab approved by NABL as per 2019 standards.
Supply of surface/wall mounted 36W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP40 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 120 lumen/watt. The luminaire shall have life class of min 50,000 burning hrs .The electronic driver used shall have a power factor ≥0.95 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from 0⁰ to 50⁰C. The luminaire shall pass electric strength test. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make/manufacturer as that of LED luminaires. Manufacturer shall have inhouse lab approved by NABL as per 2019 standards.
S & F in replacement of LED Lamp Round shape 12 watt, 220 volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply of surface/wall mounted 10W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP40 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 110 lumen/watt. The luminaire shall have life class of min 50,000 burning hrs .The electronic driver used shall have a power factor ≥0.95 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from 0⁰ to 50⁰C. The luminaire shall pass electric strength test. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make/manufacturer as that of LED luminaires. Manufacturer shall have inhouse lab approved by NABL as per 2019 standards.
S & F in replacement of LED Lamp Round shape 6 watt, 220 volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix in repair of surface mounted 36 W LED 2X2 panel backlit type only. Luminaire should be made of single piece deep drawn CRCA housing with fully diffused PC/PS diffuser for general lighting in office areas. The LEDs used should have CRI ≥ 80 and CCT 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire system efficacy of ≥ 120 lumen/watt. The luminaire shall have life class of min 50,000 burning hrs. The electronic driver used shall have a power factor ≥0.95 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 3.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ . The LED Luminaire & it's driver both should be BIS registered & shall be of the same make/manufacturer as that of LED luminaires. Manufacturer shall have inhouse lab approved by NABL as per 2019 standards.
Supply and fix Building security light with high efficient high power LED street light 35/36 watt with inbuilt daylight sensor which switches ON/OFF automatically in the absence/presence of sunlight with lens with pressure die cast aluminium housing and enclosed with toghened glass IP-66, and Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V etc including bracket suitable for fittings, clamps, fasteners and all other fixing accessories complete all as specified and directed by Engr-in Charge.
M&L in replacement of Sub main wiring concealed with 4 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
All as per srl item no. 142 here-in-before but with 2 run of 10.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 142 here-in-before but with 4 run of 16.0 sq mm FRLS copper wire with 16 Sqmm FRLS copper cable as earth wire.
Supply and fix in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, recessed on wall, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections complete all as directed.
Supply and fix in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, recesses on wall, VTPN 12 way, 240 volts with bus bar rating 415 Amps, dust and vermin proof suitable for incorporation of MCCBs 4 pole, MCB TPN and MCBs etc and making all necessary connections complete all as directed.
All as srl item no 146 here in before but of VTPN 08 way type.
M&L in replacement MCB 6 to 32 Amp, B Curve type, 10kA, single pole with over load and short circuit protection complete all as directed.
Supply and fixing in replacement MCB, SPN type of 40 to 63 amps capacity, 240V, 10 KA with all connections complete all as directed.
Supply and fixing in replacement MCB, SP type of 40 amps capacity, 240V, 10 KA with all connections complete all as directed.
Supply and fixing in replacement of MCCB 415V,4 pole 160 Amps, 36 kA, adjustable with over load and short circuit protection complete all as directed.
Taking down carefully ceiling / exhaust fan of any size, sealing cable end, dismantling blades & removing fan and blades to be deposited to MES store/Yard completeall as directed.
Supply, fixing & testing of BLDC ceiling fans, white/ Ivory colour complete with blades, 5 star rated, 230 V single phase complete with downrod, adequate size of clamp,connecting up 3 core sheathed copper cable from ceiling rose or connector to fan, including wiriting MES No in black synthetic enamel paint/engraving tool complete all as specified and directed.
Supply & fix Air Circulator fans 230 volts single phase, copper wounded motor, 450 mm sweep, Air delivery 110CMM, Speed 1200 RPM , UP/Down tilt for adjustable air direction, noise free and including fasterner & fixing arrangement complete suitable for wall mounting all as specified and directed.
Supply and fix exhaust fan made of steel body complete with louvers shutter, AC single Phase, 230V of size 300mm sweep with , blades, frame and complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding including connection with flexible twin core cable to ceilingrose and making hole etc in wall complete all as specified & directed.
M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 2 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed.
S & F in replacement of smart three phase four wire energy meter BIS 16444 :2015 (Reaffirmed 2020) marked in existing meter board /floor panels having current range 10-60Amp, 415 Volts, accuracy class 1.0 and old meter to be deposited to MES store complete all as specified & directed.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sq.mm 3.5 core complete all as specified and directed.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq.mm 2 core complete all as specified and directed.
Excavation in trenches not exe 1.5m depth and not exe 1.5m wide in Soft/loose soil and getting out complete as specified and directed
M & L for road cutting /hard standing for laying of cable and re making good the same to match the existing surface complete all as directed by Engr incharge.
Supply and spread river sand for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming.
Supplying laying, brick sub class 'B' common burnt laid in trenches for cable protection complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exe.25cm at a level complete all as specified and directed.
Removal of surplus soil to a distance not exe 50m and depositing where directed at a level not exe1.5m above the starting point complete all as specified and directed.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire
stage.html
html • 0.05 MB
techsummary_838375.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.61 MB
tender55upl.pdf
Tender Documents • 1.80 MB
BOQ_838375.xls
BOQ • 1.06 MB
credit.pdf
Additional Documents • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .