| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹35.4 L+₹22,030.65 (0.63%)Rejected-AOC 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC OK | |
| 3 | L3₹35.7 L+₹55,637.05 (1.58%)Rejected-AOC MAIN ROAD KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU AND KASHMIR | 181221 | L3 | Rejected-AOC OK | |
| 4 | L4₹36.8 L+₹1.6 L (4.60%)Rejected-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC OK | |
| 5 | L5₹37.3 L+₹2.2 L (6.12%)Rejected-AOC PLOT NO 60 PHASE II HOUSING COLONY DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC OK |
| Sl No | Description | Qty | Unit | SHIVAE CONSTRUCTION L2 | K S BUILDERS L4 | M/S SANJAY STEEL WORKS L3 | M/S SHUBAM ENGINEERS L5 | M/S PAWAN KUMAR ANAND L7 | DAVINDER SINGH L1 | MAHADEV ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of plain, corrugated or semi corrugated sheeting, of any description, roof coverings all as specified. | 504 | Sqm | 0.5 ₹252 Lowest | 6 ₹3,024 | 5 ₹2,520 | 2.5 ₹1,260 | 10 ₹5,040 | 2 ₹1,008 | 10 ₹5,040 |
| 2.00 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and complete all as directed and specified. | 520 | Sqm | 575 ₹2,99,000 | 556 ₹2,89,120 Lowest | 620 ₹3,22,400 | 580 ₹3,01,600 | 760 ₹3,95,200 | 600 ₹3,12,000 | 675 ₹3,51,000 |
| 3.00 | S&F painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,eaves etc fixed with self tapping screws as specified complete all as specified as directed. | 24 | Sqm | 575 ₹13,800 Lowest | 606 ₹14,544 | 620 ₹14,880 | 575 ₹13,800 Lowest | 760 ₹18,240 | 575 ₹13,800 Lowest | 650 ₹15,600 |
| 4.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. | 45 | Qtl | 50 ₹2,250 | 26 ₹1,170 | 40 ₹1,800 | 80 ₹3,600 | 50 ₹2,250 | 50 ₹2,250 | 20 ₹900 Lowest |
| 5.00 | S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality A all as specified and directed. | 4,500 | Kg | 85 ₹3,82,500 | 76 ₹3,42,000 | 80 ₹3,60,000 | 74 ₹3,33,000 | 80 ₹3,60,000 | 80 ₹3,60,000 | 60 ₹2,70,000 Lowest |
| 6.00 | Framed work such as grills, gratings etc with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290 Gde E-165. | 200 | Kg | 80 ₹16,000 | 66 ₹13,200 Lowest | 80 ₹16,000 | 75 ₹15,000 | 80 ₹16,000 | 66 ₹13,200 Lowest | 80 ₹16,000 |
| 7.00 | M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as directed. | 29 | Cum | 6,900 ₹2,00,100 | 4,686 ₹1,35,894 | 3,500 ₹1,01,500 Lowest | 4,050 ₹1,17,450 | 5,500 ₹1,59,500 | 3,500 ₹1,01,500 Lowest | 5,000 ₹1,45,000 |
| 8.00 | -ditto- all as per above here in but except bricks. | 2 | Cum | 2,000 ₹4,000 | 1,386 ₹2,772 | 1,200 ₹2,400 Lowest | 2,200 ₹4,400 | 1,200 ₹2,400 Lowest | 1,500 ₹3,000 | 2,000 ₹4,000 |
| 9.00 | M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as directed. | 105 | Sqm | 700 ₹73,500 | 406 ₹42,630 Lowest | 1,200 ₹1,26,000 | 1,200 ₹1,26,000 | 950 ₹99,750 | 800 ₹84,000 | 650 ₹68,250 |
| 10.00 | M&L for granite 18-20 mm (green/any colour shade approved by EIC) thick over cement screed bed laid on 15 mm thick CM 1:6 and jointed with grey cement slurry mixed with pigment ot match the shade to flooring / Window cills / steps,riser incl rubbing and polishing incl rounding to edge of marble and incl dismantling complete all as specified and directed. | 120 | Sqm | 2,000 ₹2,40,000 | 1,986 ₹2,38,320 | 2,200 ₹2,64,000 | 1,800 ₹2,16,000 Lowest | 2,200 ₹2,64,000 | 2,000 ₹2,40,000 | 1,800 ₹2,16,000 Lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
19 May 2025, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
SPL REPAIR OF BUILDING NO P-43 P-46 EQPT STORE OF 152 AD REGT AT DHAR ROAD GRN AND PROVN OF DEFI 01XWASHING PLATFORM AT LIGHT AIR DEFENCE REGIMENT COMPOSITE WORKSHOP UNDER GE ARMY DHAR ROAD. JOB NO Z SRB-31 2024-25 AND Z RW-24 2024-25
2025_MES_704769_1
8071/NIT-01/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹78,000
Yes
8 Aug 2025
19 Apr 2025
21 May 2025
20 Apr 2025
19 May 2025
5 May 2025
Amount
Dismantling of plain, corrugated or semi corrugated sheeting, of any description, roof coverings all as specified.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and complete all as directed and specified.
S&F painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,eaves etc fixed with self tapping screws as specified complete all as specified as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality A all as specified and directed.
Framed work such as grills, gratings etc with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290 Gde E-165.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as directed.
-ditto- all as per above here in but except bricks.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as directed.
M&L for granite 18-20 mm (green/any colour shade approved by EIC) thick over cement screed bed laid on 15 mm thick CM 1:6 and jointed with grey cement slurry mixed with pigment ot match the shade to flooring / Window cills / steps,riser incl rubbing and polishing incl rounding to edge of marble and incl dismantling complete all as specified and directed.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per manufacturer instructions at any height etc complete all as specified and directed. (WPC will be measured and paid separately).
Supply only liquid WPC.
M & L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care Putty complete.
M & L for Preparing new plastered or unplastered surfaces of wall and applying exterior emulsion paint white or tinted over & including a coat of wall care water proof Putty specified for external surface as per manufacturer instruction complete.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store yard and rubbish off the premises as directed.
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor finishes and finishing smooth and even without using extra cement all as specified and directed.
M & L for Machine cut 18-20 mm thick Kota stone mirror polished flooring over cement screed base 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
M & L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar, laid over cement screed of 10mm in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
M & L for preparation of new Steel surfaces of any description not otherwise described over 10 cms width or girth and apply two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer all as specified.
S&F steel rolling shutters, thickness of lath 3 mm, with ball bearing, spring, top cover, anchoring rod and hasp & staple, erected in position where required , complete push & pull all machanical type hand rolling key locking arraangment Size of shutter exc 9.00 sqm and n.exc 15.00 sqm all as specified) complete all as directed including taking down.
M & L for Providing and injecting chemical chlorpyrifos emulsifiable concentrate for Post Constructional Anti termite Treatment Along the external wall Drill in concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc. 15cm thickness (below or above ground level) including removal of debrish out of MoD Land.
M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm agg. ) as in plinth protection / path/ any paved area complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, as directed by the Engr-in-charge.
M&L for RCC Nominal mix type B1 1:2:4 (20mm graded aggregate) in landings, chajjas,shelves and similar articles with plain faces, set in cement mortar 1:4 complete all as specified and directed.
M&L for TMT Bar 10mm dia and over cut to length bend to shape required incl cranking, bending sprilly for hooping colmns hooking ends and binding with and incl MS wire (Anneled) not less than 0.9mm dia or securing with clips
M&L for 75 mm thick cement concrete type D2, 1:4:8 (using 40 mm graded aggregate) as in sub base, to be finished even and fair complete including use of necessary form work all as specified and directed.
S& F for machine pressed precast concrete interlocking paver block any shape and size,with grey cement and pigment to match, confirming to IS 15658-2006 of 60mm thick M-35 grade laid over 50 mm thick sand cushioning.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching/ filling in hold fast, pressed steel frame and all other similar works including necessary formwork complete all as directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in any type of soil.
M&L for cement concrete 1:4:8 type D2 (using 40mm graded stone aggragate) in foundations, filling and mass-concrete
M&L Reinforced cement concrete M-25 using 20mm graded aggregates in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
All as per item No 34 above but in columns
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surface of concrete square or ractangular.
All as per item No 06 above but in Slabs supported on walls ,beams and coiumns in floors,roofs, landings ,balxonies,conopies, deck slabs and in shelves and the like
M&L Form work to rough finished flat surfaces of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone complete all as specified.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone agg) as in levelling course for laying floor finishes.
Surface excavation n. exc 30 cm deep and averaging 15cm and getting out hard/dense soil complete all as specified and directed.
M&L for 75 mm thick cement concrete type B1 1:2:4 (20 mm graded stone agg) as in floor, finishing cement concrete surface even and smooth without using cement extra cement complete all as specified.
Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Excavation in post holes n.exc 0.5 cum getting out, returing and filling in & raming earth or broken rubble mixed with earth around, in layers n.exc 25CM, watering and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified and directed in any type of soil
M&L for cement concrete of type C2 (1:3:6) using 40mm graded agg in foundation filling and mass complete all as specified as directed.
S&F post and struts in fencing including cutting tops to shape as directed, drilling holes notching for wire, etc. flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 Complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point
M&L cement concrete 1:2:4 Type - B1 ( using 20mm graded stone aggragate) as in surface channel & drain all as specified and directed
M&L for machine pressed precast concrete interlocking paver block of 60mm thickness, any shape and size confirming to IS 15658 -2006 with grey cement, pigment complete all as specified and directed.
M&L for PCC type B-0,1:2:4 (12.5mm graded aggregate) as in kerbs or mud stops rounded or chamfered on edge, cills , copings etc complete all as specified and directed..
M&L for concrete bed to drain for 200 dia pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete PCC 1:4 : 8 type D-2(Using 40mm graded stone aggt) complete all as specified.
S&F Reinforced concrete pipes, class NP2, 200 mm bore laid and jointed complete with collarslaid in trenches and jointed Concrete bed to drain pipes all as specified.
S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bar and similar works confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L for factory made pre-cast cement concrete block type B1, 1:2:4 as in kerb stone made to shape as directed, exc. 10 cm in width and setting in mortar 1:4, complete all as specified and as directed.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc
T/D old unserviceable submain wiring any size 4/6 Sq mm 02 run copper conductor single phase with earth wire including PVC conduit
M & L for concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, etc with MS screw and cup washers including PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) all as specified and directed by Engineer-in-Charge for the following :-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch same board.
All as per item No 3 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.
S&F socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed.
Supply & Fixing medium step type fan regulator 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed.
M & L for sub main wiring with two run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments incl PVC conduit medium grade 25 mm dia and PVC insulated copper conductor cable drawing in PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLSH PVC insulated shall be measured and paid as one unit length.
Supply & Fixing TPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 complete all as specified and directed
Supply & Fixing MCB TPN, 63 Amps 415 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing SPN Distribution Box, double door of protection grade IP 42 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed
Supply & Fixing MCB SPN, 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
S&F Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed.
S&F LED flood light 120 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed.
S&F LED building security light 90 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed.
Taking down existing ceiling fan serviceable type and deposite MES safe coustedy all as directed after complition of B/R work refixing of ceiling fan including fixing necessary arrangements complete all as specified and directed.
Taking down Old unserviceable rusted earthing plates
supply and laying XLPE cable 50 x 3.5 core complete all as specified and directed by Engineer incharge
Excavation in trenches in Hard and dense soil n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of poles,cable laying etc, including forming bottom surface to required level and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soil/loose soil including spreading, leveling,watering & well ramming in layers not .exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches and punning down complete all as specified and directed by Engineer-in-Charge.
Material and labour cover to underground cable with one layer of bricks using sub class 'B' bricks laid flat acorss the cable complete all as specified and directed by Engineer-in-Charge.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Supply & fix fans ceiling complete 230v,1200mm sweep BEE 5 star rated white colour including all fixing arrangement and connection with 3core flexible copper cable all as specified and directed.
S&F LED builiding security light 35watt ,230 V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable , one GI medium grade suitable size dia bracket of total length 50cm and fixed to wall with 2Nos MS Clamp and fastener all as specified and directed.
Supply , laying and testing cable XLPE insulated, screened , PVC bedded, galvanized steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16sqmm 4core.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
Supply and lay pipe galvanized ,"Medium class" including fitting 25mm dia
Supply and fix PPR Gate Valves ( Brass Insert) of 25mm bore.
Deduct Schedule of Credit of Rs. (-) 58573.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
SHIVAE CONSTRUCTION (BID ID -3294730)
M/S SANJAY STEEL WORKS (BID ID -3295088)
K S BUILDERS (BID ID -3294782)
M/S SHUBAM ENGINEERS (BID ID -3295617)
MAHADEV ENTERPRISES (BID ID -3293650)
M/S PAWAN KUMAR ANAND (BID ID -3299944)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .