Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39 L+₹1.6 L (4.36%)Rejected-AOC 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹39.9 L+₹2.5 L (6.73%)Rejected-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹46.7 L+₹9.3 L (25.0%)Rejected-AOC KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | L4 | Rejected-AOC Other than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to as Type approval certificate uploaded not as per the Type approval certificate for RECD compliance mention in Tender document |
Tender Value
₹40.4 L
EMD Value
₹80,760
Closing Date
7 Aug 2023, 6:00 pmClosed
Maj Mathews M Shepherd
Mathura
PROVISION OF RETROFIT EMISSION CONTROL DEVICES IN EXISTING DG SET HELD UNDER GE (WEST) MATHURA
2023_MES_605082_1
8300/1161/E8
Open Tender
Civil Works
Item Rate
180 days
GE (WEST) Mathura
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹80,760
Yes
4 Oct 2023
27 Jun 2023
14 Aug 2023
27 Jun 2023
7 Aug 2023
18 Jul 2023
Amount
Supplying, installation, testing & commissioning of Retrofit Emission Control Device (RECD) in existing Diesel Generator Set of capacity 140 KVA of any make, model and vintage by making necessary modification, welding of suitable size angle and pipe for support structure and suitable size ladder including cutting of old silencer/muffler without damaging diesel generator set to reduce guaranteed specification particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency : Minimum 70% for all DG Sets, emission tested as per D2, 5 -mode test cycle as specified in ISO-8178-Part 4 complete all as specified and as directed by Engineer-in-Charge with following Specification:- Cont/-..
Cont/-.. (a) Purification Technology :- No filters, No solvents, No Chemicals (b) Pollution Captured : PM 2.5 to PM 10 (c) ELectric Supply : 220 Volts AC (d) Material : Mild Steel (e) Reported PM Reduction : 80% to 90% (f) By Product : Soot Particles. (g) Disposal : No burning or dumping of captured partured particles. (h) Collection of captured Particles : Once in 02 Months. (j) Capturing Chamber Material : Stainless Steel. (k) Mechanicial Pressure Release valve (PRV) should be available. Cont/-..
Cont/-.. (l) Sensors (Temp & Pressure) should be available. (m) Automatic bypass System should be available. (n) The Retrofit Emission Control Device (RECD) should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Retrofit Emission Control Device (RECD). (o) 02 year warranty including manufacturing defects on sensors, back pressure and leakage. (p) Technology : Diesel Oxidation Chamber (Catalyst type) with particulate regenerating trap. The output result of Retrofit Emission Control Device (RECD) should be as per CPCB II norms. Cont/-..
Cont/-.. (q) Maximum back pressure of 8.500 KPa exertd by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set). Necessary precaution to be taken in Exhaust scheme design to avoid condensate/steam back entry to DG sets which is/are not in operation. (r) The Retrofit emission control device shall be with corrosion resistive and heat resistance paint. (s) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided along with each Retrofit Emission Control Device (RECD). (Note : Retrofit Emission Control Device (RECD) shall comply all norms as per CPCB.
Description all as per Item No 1.00, 1.01 to 1.03 above but DG set of capacity 160 KVA
Description all as per Item No 1.00, 1.01 to 1.03 above but DG set of capacity 200 KVA
Description all as per Item No 1.00, 1.01 to 1.03 above but DG set of capacity 400 KVA
Note for Serial Item No 1.00 to 4.00 :- (a) Type approval certificate with registration number & date (from one of the CPCB recognised/ approved lab as shown here in - after). Shall be upload by the contractor alongwith application of tender documents in Cover -1. (b) Test report and Type approval certificate of the Retrofit Emission Control Device will be from one of the following CPCB recognised / approved Laboratories shall be produced before installtion:- (i) Automotive Research Association of India, Pune (Maharashtra). (ii) International Centre for Automotive Technology, Manesar (Haryana) (iii) Indian OiL Corporation, Research and Development Centra, Faridabad (Haryana) (iv) Indian Institute of Petroleum, Dehradun (Uttarakhand) (v) Vehicle Research Developement Establishment, Ahmednagar (Maharastra) (c) Number of preventive maintenance visits in a year during warranty period 2 visit. Cont/---
Cont/-- (d) The contractor shall provide the trail run (testing) of Retrofit Emission Control Device (RECD). The trial run shall be for two hours/ The electrical loading shall not be more than the rated capacityof the DG Set. (e) Any other activity, exhaust piping of suitable size, civil work, copper wire etc required at site to make the Retrofit Emission Control Device (RECD) fitment will be provided by the contractor without any extra cost to the Govt & no additional payment will be made on this account. (f) Emission of PM (Particulate Matter) must be tested from NABL approved lab before and after fixing/installation the device and test report to be submitted/provided.
M/s DEVI DAYAL CONSTRUCTION CO
Ms Kamal Kant Agarwal
M/s R L PAREEK
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .