Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L1 | Accepted-AOC AOC | |
| 2 | L2₹33.8 L+₹82,171.03 (2.49%)Rejected-Finance NANAK TOWER 3RD FLOOR SEVOKE ROAD SILIGURI | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹33.9 L+₹89,128.76 (2.70%)Rejected-Finance SANTINEKATAN ROAD BOLPUR | BOLPUR | L3 | Rejected-Finance NOT L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
17 Feb 2025, 4:00 pmClosed
Executive Engineer,AMD P.H.E Dte
Office of the Executive Engineer,Asansol Mechanical Division,Public Health Engineering Directorate,JANASASTHYA KARIGORI BHAVAN,PASCHIM BARDHAMAN,713 305
Additional works corresponding to providing and installation of MCC Starter panel with SCADA for whole operational system at Panaghar IT Park( Both WTP and Intake) and other allied works, DMC area, District-Paschim Bardhaman.
2025_PHED_805428_1
WBPHED/EE/AMD/NIeT-44 of 2024-2025
Open Tender
MISC ELECTRICAL WORKS
Item Wise
30 days
panagarah
Please refer Tender documents.
3 documents required · 3 mandatory
₹68,000
19 May 2025
22 Jan 2025
19 Feb 2025
22 Jan 2025
17 Feb 2025
22 Jan 2025
Amount
Supply and delivery of following Electrical Mountings & Accessories at Site:-
Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted 415 Volt PDB cum MCC Panel having required Feeders with PLC & SCADA compatible. (Clariflocullator Panel Out Door Type)
Supply, delivery and Storage at site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Wall Mounted 415 Volt, Local Push Button Switch with PLC & SCADA Compatible.(For Sludge Recirulation & Sump Cum Pump Room)
Supply, delivery and storage at site 4 Bar, 100 Amp Kiosk Box, out door type. (Make:-Approved Make)(Beside the Clariflocullator)
Supply, delivery and storage of 250 Amp, Molded Cased circuit breaker with Thermal Magnetic Trip Unit, Adj. Thermal Fixed Magnetic (ATFM), Ics = 100% Icu, 415VAC, 50Hz. (Make:-Approved Make) (At LT PDB Panel at Sub-Station)
Supply, delivery and storage of Local Push Button switch.(For Chemical Room's Motor)
Supply, delivery and storage of 32 Amp, 415 VAC, 50 Hz Main switch.(Make:- Approved make)
Supply, delivery and storage of Outdoor type Local Push Button switch.(For Motorised Sluice Valve)
Supply, delivery and storage of Outdoor type Local Push Button switch.(For Flush Mixture's)
Supply, Delivery and storage at site 4 Core 1.1 KV Grade 10 Sq. mm. Cu industrial flexible cable as per IS:694.(From Kiosk To Main shaft of Clariflocullator to Panel incomer)(Make -Approved make)
Supply, Delivery and storage at site 3½ Core 1.1 KV Grade 185 Sq. mm. XLPE insulated Al.Ar Cable as per IS:7098(Part-I)2011.(For Filter House)(Make:-Approved make)
Supply, Delivery and storage at site 3 Core 1.1 KV Grade 10 Sq. mm. XLPE insulated Al.Ar Cable as per IS:7098(Part-I)2011.(For Flush Mixture's Motor)(Make:-Approved make)
Supply, Delivery and storage at site 12 Core 1.1 KV Grade 1.5 Sq. mm. XLPE insulated armoured and extruded PVC type ST2 outer sheathed as per IS:7098(Part-I)2011 with Upto date amendments.(For Actuator Operated Sluice Valve+ Back Wash inlet actuator+ Main Motorized Sluice)(Make:-Approved make)
Supply, Delivery and storage at site 4 Core 1.1 KV Grade 6 Sq. mm. Cu industrial flexible cable as per IS:694.(From Sludge Recirculation Pump & Sump Pump)(Make -Approved make)
Supply, Delivery and storage at site 3 Core 1.1 KV Grade 4 Sq. mm. XLPE insulated Al.Ar Cable as per IS:7098(Part-I)2011.(For Chemical delivery Pump & One feeder for E.O.T. Crane)(Make:-Approved make)
Supply, Delivery and storage at site 8 Core 1.1 KV Grade 1.5 Sq. mm. XLPE insulated armoured and extruded PVC type ST2 outer sheathed as per IS:7098(Part-I)2011 with Upto date amendments.(For Flush Mixture-3 Nos + Chemical Houses Stirrer LPBS-7 Nos + Motorised Sluice Valve-7 Nos)(Make:-Approved make)
Earthing & lightning protection arrangement for electrical installation as per ISS and IE rules.(E/P-2 Nos)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness.
Laying of three cables upto 35 sqmm in an underground trench in single tier formation (horizontal) the trench size : 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricks per mtr. as separator between the cables including filling the space between the bricks and cables and also the trench with shifted soil, levelling up and restoring surface duly rammed.(From Chemical house to Flush Mixture)
Laying only Cable upto 50 sqmm through existing PVC Pipe line/Cable Tary for-3/12 Core.
Laying only Cable above 50 sqmm but not exceeding 400 sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core.
Installation of LPBS, Kiosk for Clariflocullator, Clariflocullator out door type panel with MCCB, (From SL No-1.01 to 1.08), at the proper place, doing all necessary erection job like cable connection, Compression gland, connect with prime mover/Motor, Sockettings, also existing Earthing etc as per direction of EIC.
Testing and Commissioning of whole system as per direction of EIC.
Add GST @ 18%
Add CESS @ 1%
MS P P ELECTRICALS (BID ID -6126457)
SINHA ELECTRICALS (BID ID -6126997)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .