| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 CrAccepted-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹7.9 Cr | L1 | Accepted-Finance Being L1 |
| 2 | L2₹8.0 Cr+₹8.3 L (1.06%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹8.0 Cr+₹8.3 L (1.06%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹8.0 Cr+₹11.4 L (1.44%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹8.0 Cr+₹11.4 L (1.44%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹8.2 Cr+₹29.1 L (3.68%)Rejected-Finance 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | ₹8.2 Cr+₹29.1 L (3.68%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹8.3 Cr+₹44.9 L (5.68%)Rejected-Finance SCF 126 OPP SUKHRAJ CINEMA GONIANA ROAD BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | ₹8.3 Cr+₹44.9 L (5.68%) | L5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | Sant Construction Co. L2 | MAHESH KUMAR SINGLA CONTRACTOR L4 | M K ENGINEERS CO. L6 | vijay builders L7 | BHARAT ELECTRICAL TRADERS L1 | mayur enterprises L3 | M/s DMR Builders Pvt Ltd L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commissioning of package type/unitised 11KV/433 V Outdoor Sub-Station, 500KVA with specification as given below:-
Make of CSS-ABB, SEIMENS, SCHEINDER | 2 | Each | 53,00,000 ₹1,06,00,000 | 54,00,000 ₹1,08,00,000 | 60,00,000 ₹1,20,00,000 | 67,00,000 ₹1,34,00,000 | 62,20,000 ₹1,24,40,000 | 61,00,000 ₹1,22,00,000 | 49,00,000 ₹98,00,000 Lowest |
| 2.00HT SWITCHGEAR | ||||||||||
| 3.0011kV 630Amps 21KA/3 sec. 3 Way Non-Extensible Ring Main Unit Compact switchgear consisting of 3 No. fixed motorised operated Vacuum Circuit Breaker Module in SF6 insulated stainless steel enclosure with copper busbar. Gas Tank shall be made out of SS 304 Grade with minimum 2.5 mm thick sheets Steel. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. The vacuum circuit breaker module should have independent fault-making type earthing switch and must not engage vacuum interrupter for earthing purpose of the cable. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No. | ||||||||||
| 4.00The RMU shall have following components: | ||||||||||
| 5.00INCOMING:- | ||||||||||
| 6.00(a) Capacitive voltage indication fixed type system with LED for each LBS & VCB module -01 No. | ||||||||||
| 7.00(b) SF6 Gas pressure indicator for entire gas tank. | ||||||||||
| 8.00(c) Padlocking facility in each VCB module. | ||||||||||
| 9.00(d) incomer CT Ratio CTs : 400-200/1-1, 5VA, Cl-5P10, Cl-0.5 | ||||||||||
| 10.00(e) PT type : 11000/V3/110/V3/110/3,50VA,Cl-1.0,3P Feeder Protection and Control Relay, REF615 of ABB or Equivalent of L&T/ Siemens, Protections 50,51,50N,51N,46,49,95, Measurement for 3I, I0, 3U,UO,Kw, KVA, PF, Hz, Kwh, 16DI + 10 DO, One front RJ45 Port, Two Rear FO(LC) Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature. Seperate TCS and Mastertrip relay to be provided -01 Nos | ||||||||||
Tender Value
₹7.5 Cr
EMD Value
₹7.0 L
Closing Date
7 Jul 2026, 6:00 pmClosed
Chief Engineer Bathinda zone
HQ CE Bathinda Zone, Bathinda Mil Stn-151004
REPLACEMENT UPGRADATION OF OLD TRANSFORMER AND RESUSCITATION OF ELECT PANELS AND ASSOCIATED WORK UNDER GE (U) BATHINDA
2026_MES_770803_1
84586
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (U) Bathinda
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (U) Bathinda
₹7.0 L
Yes
10 Aug 2026
9 Jun 2026
9 Jul 2026
9 Jun 2026
7 Jul 2026
24 Jun 2026
10 Jun 2026 - 23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station, 500kVA made from G. I. enclosure complete as required conforming to IEC 62271-202 and relevant IS/IEC specifications as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation.Vacuum Interrupter, RMU, LT switchgear and CSS enclosure shall be of same make to ensure life cycle optimization.
Note : Make of CSS -ABB,SEIMENS,SCHNEIDER.
Package substation will have the following equipment :- | 2 | Each | - | - |
| 2 | A) HT SWITCHGEAR | - | - | - | - |
| 3 | 11kV 630Amps 21KA/3 sec. 3 Way Non-Extensible Ring Main Unit Compact switchgear consisting of 3 No. fixed motorised operated Vacuum Circuit Breaker Module in SF6 insulated stainless steel enclosure with copper busbar. Gas Tank shall be made out of SS 304 Grade with minimum 2.5 mm thick sheets Steel. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. The vacuum circuit breaker module should have independent fault-making type earthing switch and must not engage vacuum interrupter for earthing purpose of the cable. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No. | - | - | - | - |
| 4 | The RMU shall have following components: | - | - | - | - |
| 5 | INCOMING:- | - | - | - | - |
| 6 | (a) Capacitive voltage indication fixed type system with LED for each LBS & VCB module -01 No. | - | - | - | - |
| 7 | (b) SF6 Gas pressure indicator for entire gas tank. | - | - | - | - |
| 8 | (c) Padlocking facility in each VCB module. | - | - | - | - |
| 9 | (d) incomer CT Ratio CTs : 400-200/1-1, 5VA, Cl-5P10, Cl-0.5 | - | - | - | - |
| 10 | (e) PT type : 11000/V3/110/V3/110/3,50VA,Cl-1.0,3P Feeder Protection and Control Relay, REF615 of ABB or Equivalent of L&T/ Siemens, Protections 50,51,50N,51N,46,49,95, Measurement for 3I, I0, 3U,UO,Kw, KVA, PF, Hz, Kwh, 16DI + 10 DO, One front RJ45 Port, Two Rear FO(LC) Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature. Seperate TCS and Mastertrip relay to be provided -01 Nos | - | - | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
TenderDocuments84557.pdf
Tender Documents • 1.11 MB
BOQ_863197.xls
BOQ • 0.35 MB
corrigendum02.pdf
PDF • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .