Executive Engineer, KPDCL, ED2nd, Rajbagh, Sgr
Office of the Executive Engineer, KPDCL, ED2nd, Rajbagh, Sgr
Replacement of Bare LT Conductor by LT AB Cable 3x120 sqmm of 07 No. Baghat and Rajbagh DT Sub-Stns 100 kVA, 250 kVA alongwith insertion of ST pole wherever reqd within jurisdiction of KPDCL, ED 2nd Rajbagh - LT AB cable shall be provided by Deptt.
2022_PDD_177637_1
ED-II/04 of 2022-23 Dated 04/07/22
Open Tender
Electrical Works
Turn-key
90 days
Baghat and Rajbagh of ED 2nd, Sgr
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
Ex. Engineer,KPDCL, ED2nd Credited to MH0801 Power
₹72,600
Yes
18 Aug 2022
5 Jul 2022
30 Jul 2022
5 Jul 2022
29 Jul 2022
7 Jul 2022
5 Jul 2022 - 7 Jul 2022
Amount
Supply and Erection of ST Pole 8 Mtr. Long (ST-410 SP15) with galvanized channel earthing arrangement as per drawing no. CE/P&P/Dwg/2022-STP-E001 including loading, carriage and unloading upto site
Supply and Fixing of Suspension/Tension Clamp (Anchor clamp / dead end clamp) with eye hook suitable for LT ABC of 70 sq.mm Bare neutral messenger
Supply and Fixing of GI Pole Support Clamp including GI Nut and Bolts with washers for 11 Mtr Pole with size - 50x8x376 mm 9 mtr pole with size - 50x8x376 mm 8 mtr with size 50x 8x 332 mm 8 mtr or 9 mtr PCC with size 50x8x441mm
Supply and Fixing of Cable tie (each packet contains 100 Nos.)
Supply and Fixing of Cable end caps
Supply, Laying, Testing and Commissioning of 4 core 35 mm2 PVC Cable from AB Cable taping point through Piericing connector to PMDB including P/F of Thimbles/Clamps
Supply of Piercing Connector for street light connections (main line 70-120 sqmm/branch line section 4-25 sqmm) insulated and insulated branching and bare and insulated branching in case of neutral messanger
Fixing of Piercing Connector for street light connections (main line 70-120 sqmm/branch line section 4-25 sqmm) insulated and insulated branching and bare and insulated branching in case of neutral messanger
Supply of Piercing Connector for DB connection from main ABC to DB (main line 70-120 sqmm/branch line section 35-50 sqmm) insulated and insulated branching and bare and insulated branching in case of neutral messanger
Fixing of Piercing Connector for DB connection from main ABC to DB (main line 70-120 sqmm/branch line section 35-50 sqmm) insulated and insulated branching and bare and insulated branching in case of neutral messanger
Supply of Piercing connector for ABC to ABC Tee connection (main line 70-120 sqmm/branch line section 70-120 sqmm) insulated and insulated branching and bare and insulated branching in case of neutral messanger
Fixing of Piercing connector for ABC to ABC Tee connection (main line 70-120 sqmm/branch line section 70-120 sqmm) insulated and insulated branching and bare and insulated branching in case of neutral messanger
Supply of 3 Phase SMDB (Service Main Distribution Box) IP54 made from 20 SWG CRCA MS sheetby Deep drawn method with connection terminals for R,Y, B & N as per specifications. Internal size of the box shall be 225mm x 285mm x 120mm used for connection through ABC line and for giving connections to the consumers 3phase-1 incoming 4 outgoing I/C- 1, O/G-2-4 (200 A, 0.415 kV) for RYB Phase. The DB should have Bottom entry of Cable with proper Glands/grommets-Safety Screws and Back Clamp suitable for 11/9/8 Mtr ST Pole or 9/8 mtr PCC poles with Nuts/bolts.
Installation, Testing and Commissioning of 3 Phase SMDB (Service Main Distribution Box) IP54 made from 20 SWG CRCA MS sheetby Deep drawn method with connection terminals for R,Y, B & N as per specifications. Internal size of the box shall be 225mm x 285mm x 120mm used for connection through ABC line and for giving connections to the consumers 3phase-1 incoming 4 outgoing I/C- 1, O/G-2-4 (200 A, 0.415 kV) for RYB Phase. The DB should have Bottom entry of Cable with proper Glands/grommets-Safety Screws and Back Clamp suitable for 11/9/8 Mtr ST Pole or 9/8 mtr PCC poles with Nuts/bolts. The job also includes disconnection/reconnection of consumer energy meter and aluminium lugs, if required.
Providing and Earthing of ST Pole Complete by GI Pipe 40 mm 3mtr long through GI Strip 25x3 mm
Supply of Pre insulated straight through joints suitable for 1(3X120+1x16(street light)+1X70(insulated messenger) Cable
Fixing of Pre insulated straight through joints suitable for 1(3X120+1x16(street light)+1X70(insulated messenger) Cable
Providing and Fixing of Insulation tape (red / yellow / black)
Providing and Fixing of Misc Items such binding wire, screws, Thimbles of sizes, Clamps of sizes etc.
Providing and Painting of ST Poles 8 mtr long with 1 coat and red oxide and 2 coats of aluminium paint
Providing and Cement Bottoming of ST Poles 8 mtr long in the ratio 1:2:4 mix as per REC standards 0.45 cum/pole
Providing and Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply, Installation, Testing and Commissioning of LT Distribution Box for 250 kVA DTR with MCCB for Outgoing Circuits, Distribution Boxes made out of CRCA MS for controlling the L.T. feeders from the L.T. side of Distribution Transformers IS: 8623 (amended upto date) for enclosure Box & for degree of protection provided by enclosures of electrical equipments. The Aluminum Busbar for Phase & Neutral should be of size 25x8 mm and with Heat Shrinkable bus bar insulation tubing of Red Yellow-Blue & Black mounted on epoxy resin cast bus insulators fixed on suitable fixing arrangement with adequate clearance. The DB should have Bottom entry of Cable with proper Glands/grommets-Safety Screws Outgoing 02 no. MCCB - 200 A O/G Link Disconnector 06 no. - 200 A
Supply, Installation, Testing and Commissioning of LT Distribution Box for 250 kVA DTR with MCCB for Outgoing Circuits, Distribution Boxes made out of CRCA MS for controlling the L.T. feeders from the L.T. side of Distribution Transformers IS: 8623 (amended upto date) for enclosure Box & for degree of protection provided by enclosures of electrical equipments. The Aluminum Busbar for Phase & Neutral should be of size 25x8 mm and with Heat Shrinkable bus bar insulation tubing of Red Yellow-Blue & Black mounted on epoxy resin cast bus insulators fixed on suitable fixing arrangement with adequate clearance. The DB should have Bottom entry of Cable with proper Glands/grommets-Safety Screws Outgoing 03 no. MCCB - 200 A O/G Link Disconnector 09 no. - 200 A
Supply, Installation, Testing and Commissioning of LT Distribution Box for 100 kVA DTR with MCCB for Outgoing Circuits, Distribution Boxes made out of CRCA MS for controlling the L.T. feeders from the L.T. side of Distribution Transformers IS: 8623 (amended upto date) for enclosure Box & for degree of protection provided by enclosures of electrical equipments. The Aluminum Busbar for Phase & Neutral should be of size 25x8 mm and with Heat Shrinkable bus bar insulation tubing of Red Yellow-Blue & Black mounted on epoxy resin cast bus insulators fixed on suitable fixing arrangement with adequate clearance. The DB should have Bottom entry of Cable with proper Glands/grommets-Safety Screws 01 no. MCCB- 200 A O/G Link Disconnector 03no. - 200 A
Supply, Fabrication and Fixing of GI Channel/Angle/Flat of sizes including clamps, GI Nut and Bolts with washers
Supply, Laying, Testing and Commissioning of 70 mm² XLPE LT Cable Single Core, un-armoured, FRLS from Transformer LT DB neutral to Messenger Wire including PG Clamp
Supply, Laying, Testing and Commissioning of 16 mm² Cable (2C) from LT DB box to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including thimbles/Clamps/Lugs.
Supply, Laying, Testing and Commissioning of 400 sqmm XLPE LT single Core unarmoured Cable from transformer to LT BD (alongwith Required Aluminium Thimbles P/F included)
Installation, testing and commissioning of 120 mm² AB Cable (3X120+1x16 (street light) +1X70( messenger)) XLPE (1.1kV, 3+1 C, Al) including loading from Divisional Stores at Bemina, its carriage and unloading upto site (Cable to be Provided by the Department)
Striaghtening of existing tilted Poles by way of opening the pits of 9/8 Mtr concerned poles
Dismantling of existing ACSR Conductor and LT Shackle Insulators along with U Clamps including Transportation its carriage/Loading/unloading from site to Divisional Stores at Bemina
M/S R R ELECTRICAL SERVICES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .