| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC | ₹42.9 L Quoted ₹43.1 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹49.7 L+₹6.5 L (15.2%)Rejected-Finance | ₹49.7 L+₹6.5 L (15.2%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹51.4 L+₹8.3 L (19.2%)Rejected-Finance 2ND 6 KEDIA HOUSE MA ROAD BYELANE 1 REHABARI GUWAHATI ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | ₹51.4 L+₹8.3 L (19.2%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹52.3 L+₹9.1 L (21.2%)Rejected-Finance | ₹52.3 L+₹9.1 L (21.2%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹53.0 L+₹9.9 L (22.9%)Rejected-Finance | ₹53.0 L+₹9.9 L (22.9%) | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
3 Jan 2022, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
PROVN OF CERTAIN B/R AND E/M WORKS SERVICES AT BFTS UNDER GE (AF) BAMRAULI
2021_MES_493945_1
8606/E8
Open Tender
Civil Works
Works
180 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (AF) Bamrauli
₹92,000
10 Mar 2022
11 Dec 2021
4 Jan 2022
11 Dec 2021
3 Jan 2022
28 Dec 2021
Amount
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for double charged Vitrified Ceramic digital coloured tiles of size of tiles exc. 36 Sqm but not exc 42 Sqm in each tiles (Square/rectangular) polished, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade tiles including 15mm thick screed bed layer in CM (1:6) complete all as specified and directed.
All as per item No 2 above but as in skirting set & jointed in neat slurry and pointed in white or colour cement to match the shade tile including 10mm thick rendering in CM (1:4) complete all as specified and directed. (Premium quality).
Supply and fixing in repair false ceiling of 16 mm thick fine fissured RH-99 prime Make – Armstrong Tegular and acoustic purpose of size 600 x 600 x 16mm thick fixed in GI grid powder coated snap grid ceiling of I section 25 mm x 25 mm x 1.5 mm thick and T section 25 mm x 25 mm x 1 mm with suspender of 10 gauge GI wire of required length, fixed with dash through fastener bolt of approved quality 04 Nos for per sqm including necessary cutting, securing and making good to disturbed surface complete all as specified and directed.
M&L for complete removal of existing treatment of old plastered, surfaces of walls and applying two coat of plastic emulsion paint over a coat of primer with a thin layer of 1.5 mm thick wall care putty complete all as specified and directed
Taking down chowkhats with shutters (without taking off shutters from the frame) area n exc 1.5 sqm each including cutting holes in brick / stone wall built in cement / lime mortar, embedded portion exc half brick but n.exc one brick for inserting new hold fast and making good the disturbed portion/ surfaces, in CM 1:3 complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frame) area exc 1.5 sqm but n. exc 4 sqm each including cutting holes in brick / stone wall built in cement / lime mortar, embedded portion exc half brick but n.exc one brick for inserting new hold fast and making good the disturbed portion/ surfaces, in CM 1:3 complete all as directed by Engineer-in-Charge.
S&F 12 mm thick plain toughen glass door with hole and cutout including one set of floor spring 2 x Big L stainless steel at corner 08 x L connector of stainless steel and 2 x 25 mm dia and 600 mm long SS Handle as per drg, itching on glass and engraving of BFTS Logo as per design etc complete all as directed by Engineer-in-Charge.
S&F 12 mm thick plain toughened fixed glass in door opening / partition with SS fixtures etc complete all as directed by Engineer-in-Charge.
S&F stainless steel concealed door closer / over head / in floor mounted best quality suitable for door shutters of 851 to 1000mm in width etc complete all as specified and directed.
S&F Rebated mortice aluminium lock vertical type size 100mm with 4 levers.
Taking down and refixing after aligning the doors completely by changing beading floor spring, handles and all necessary
S&F powder coated anodised aluminium frame/shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as directed by Engineer-in-Charge.
M&L for anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m (minimum) including all necessary fittings, joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and lock etc complete all as specified and directed.
S&F powder coating Anodised aluminium windows and ventilators shutters, side hung type without sash bars, aluminum sections weighing 0.55 kg/m (minimum) including necessary joining cleats, glazing clips rubber packing, anodized aluminium snap beading. Screws, anodized aluminium fittings such as peg syays 150 mm long (1 No), hinges type B-21 100 mm lon (2 No) suitable handle (1 No). complete all as specified and directed. (minimum thickness of powder coating 50 micron). complete all as specified and directed.
S&F 5.50 mm thick tinted glass and glazing with rubber beading for aluminium doors/ and as in windows area as required complete all as specified and directed.
S&F aluminium door closer hydraulically regulated designation No 3 universal type suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and directed.
S&F aluminium handle in circular shape for pull of door shutter complete all as specified and directed.
S&F 200 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed
M&L for Rendering 15 mm thick on fair faces or brick work or concrete surfaces in cement mortar (1:4) and finished fair and even without using extra cement.
Demolition of brick work stone boulder masonry built in cement mortar including all quoins arches pillars, etc complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and directed
M&L for complete removal of existing treatment of old plastered, surfaces of walls and applying two coat of oil bound distemper over a coat of primer with a thin layer of 2 mm thick wall care putty complete all as specified and directed
S&F mild steel frame work for stair case including necessary welding, landing plaster etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old painted wooden surfaces of any description over 10 cm width or girth and applying over coat of description over 10 cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and directed.
M&L for preparing old painted steel surfaces of any description over 10 cm width or girth and applying over coat of description over 10 cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed.
M&L for Hardcore (Broken stone or boulders) of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 1.5 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for cement concrete type D2 (1:4:8) (40 mm graded stone aggregate) in sub base and foundations filling and mass concrete complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces or brick work or concrete surface finished even and smooth without using extra cement and mixed with water proofing compound @ 3% by weight of cement. (Note : WPC will be measured and paid separately) complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (Horizontal sloping for fair finished surface) complete all as specified and directed.
M&L for Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cracking, bending spirally for hooping ends and binding with and including mild steel (annealed) not less than 0.9 mm dia securing clips complete all as specified and directed.
M&L for Mild steel TMT bars 6 to 8 mm dia and over cut to length, bent to shape required, including cracking, bending spirally for hooping ends and binding with and including mild steel (annealed) not less than 0.9 mm dia securing clips grad Fe 410 (Gde E-250) complete all as specified and directed.
M&L for RCC type B1 (1:2:4) (20mm graded stone aggregate) as in slabs supported on walls beams, and columns in floors, roofs, landings balconies, canopies, deck slabs and in shelves.
Supply only Water proofing compound complete all as specified and directed
M&L for Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of cement wash with white cement etc complete all as specified and directed
M&L for Preparation of new plastered surfaces of walls and applying two coats of OBD over a coat of primer etc complete all as specified and directed
M&L for Preparation of new plastered surfaces of ceiling and applying three coats of white wash etc complete all as specified and directed
Excavating in post holes (or similar holes) in hard dense soil each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface, work in hard/dense soil complete all as specified and directed.
M&L for PCC (1:2:4) type B2 using 40mm graded aggregate as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
S&F steel work in tubular trusses, purling, rafters, struts, vertical members and similar work including special shape washers complete using ERW or induction butt welded tubes conforming to IS-1161-1979, grade St-240 complete all as specified and directed by Engineer-in-Charge.
S&F MS plate, cleats, holding down bolts, nuts bolt, washer’s screws of any size and sections complete all as specified and directed by Engineer-in-Charge.
M&L for Pre-painted galvalume aluminium zinc coating 275 GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering / cladding to wall, fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Returning filling in, foundation / trenches including spreading, levelling, watering and well remming in layers n exc 25 cm complete all as specified and directed.
Removing surplus excavated soil/materials to a distance not exc 50 mtr and depositing where directed at a level n exc 1.5 mtr from the starting point complete all as specified and directed.
M&L for 40 mm cement concrete type B1 (1:4:8) (20 mm graded stone aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate bibrator, fillng the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as per manufactures instructions.
S&F Glass dividing strip 3 mm thickness and 38 mm wide complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for 75mm cement concrete (1:2:6) type C-2 (40mm graded aggregated as in flooring / plinth portion all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:3 on other than fair faces of brick work or stone masonry surface finished fair and even complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall, projected face of chajja, projected face of roof slabs & fce and sides of sunshade including preparation of surfaces including cornices, plasters etc complete and applying two coat of exterior emulsion paint in pattern (two or more colour combination) over one coat of alkali resistant primining paint over 3mm thick wall care putty (Make-JK/Birla white) complete all as specified and as directed by the Engineer-in-Charge. (Note : Design, pattern & colour will be approved by the GE).
M&L for complete removal of existing treatment from wall, projected face of chajja, projected faces of roof slabs & face and sides of sunshade including preparation of surfaces including cornices, plasters etc complete and applying two coat of exterior emulsion paint in pattern (two or more colour combination ) over one coat of alkali resistant primining paint over 3mm thick wall care putty (Make- JK/Birla white) complete all as specified and as directed by the Engineer-in-Charge. (Note :- Design, pattern & colour will be approved by the GE)
Demolition of cement concrete (un reinforced) of any description and in any position not other wise specifically provided for complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:3 on fair faces of brick work or concrete surface finished fair and even etc complete all as specified and directed.
M&L for 10 mm thick rendering in CM (1:3) on fair faces of brick work or concrete surface of Chajja, roof, Projection & slab etc ceiling surfaces finished even and fair including taking down old ceiling plaster ht upto 7-8 mtr etc complete all as specified and directed.
M&L for 5 mm thick rendering in CM (1:3) on fair faces of brick work or concrete ceiling surface finished even and fair including taking down old ceiling plaster etc complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall, and applying three coat of white wash etc complete all as specified and directed.
M&L for complete removal of existing roof treatment (far felt of any thickness) at any height of the building and cleaning the roof thoroughly with wire brushes and brooms to remove all loose particles and re removing the debris out side MoD land all as specified and directed.
Demolition of Mud/mud puska in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of ) complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in roof padding, benching existing roof slab to slope as per existing or as directed
M&L for screed bed of 10 mm thick in cement mortar (1:4) cover concrete surfaces of roof, mixed with @ 200 ml liquid water proofing compound by 50 Kg weight of cement (1 Bag) as per manufacturers instruction including finishing surfaces even and smooth without using extra cement complete all as specified and directed. (WPC) shall be measured and paid separately). (Note : WPC will be measured and paid separately).
M&L for cleaning the roof surface from dust /dirt and any other foreign materials and applying a coat of bituminous primer @ 0.30 liters per square meter uniformity after the surfaces fully dried complete all as specified and directed.
M&L for applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over APP Membrane @ 1.20 kg/Sqm complete all as specified and directed.
M&L for APP based polymeric water proofing membrane minimum weight 3.6 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 Gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100 mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supersion of Manufacturs all as specified and directed.
M&L for brick tiles 40 mm thick over roof treatment. Laid over and including 15 mm thick screed be din cement mortar (1:6) mixed with and including polymer based liquied water proofing additive @ 200 ml liquid water proofing compound by 50 Kg weight of cement (1 Bag) or as per manufacturers specification and joints of brick tiles shall be filled with cement mortar (1:4) mix with and including 5% curde oil complete all as specified and directed.
M&L for two coats of aluminium paint on APP based polymeric water proofing membrane 0.1 Ltr/Sqm in each coat including preparation of surfaces of roof etc complete all as specified and directed by Engineer-in-Charge.
M&L for cutting out cracks to V section in existing roofs or terrace, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) (by weight ) complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cills bencing and other similar bands, plinth courses, parapets, coping bed plates and like including weathering, slightly rounded or chamfered angles and throating finishing surface even and smooth as directed including use and waste of form work complete all as specified and directed
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position exc 500 Ltr n.exc 1000 ltr cap etc complete all as specified and directed.
S&F 500 liters capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hosted and fixed in position complete all as specified and directed
S&F 1000 liters capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hosted and fixed in position complete all as specified and directed
S&F in repair 20mm dia PTMT ball valves high pressure of with epxy coated aluminium rod and high density plastic ball screwed for iron pipe and complete all as specified and directed
S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel screwed both ends for iron pope or for unions and fixed in repair complete all as specified and directed
Taking up or down steel water tubing and connections, including cleaning for refixing or removing to store 15 mm dia complete all as specified and directed
Taking up or down steel water tubing and connections, including cleaning for refixing or removing to store 20 mm dia complete all as specified and directed
Taking up or down steel water tubing and connections, including cleaning for refixing or removing to store 25 mm dia complete all as specified and directed
S&F Tube medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floors 15 mm bore complete all as specified and directed
S&F Tube medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floors 20 mm bore complete all as specified and directed
S&F Tube medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floors 25 mm bore complete all as specified and directed
Refixing old steel tubing 15mm bore and connection in new or old position (Walls, ceiling, floors, etc) and all as specified and directed
Refixing old steel tubing 20mm bore and connection in new or old position (Walls, ceiling, floors, etc) and all as specified and directed
Refixing old steel tubing 25mm bore and connection in new or old position (Walls, ceiling, floors, etc) and all as specified and directed
Taking down soil, waste and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks, bends etc complete all as specified and directed.
S&F 110mm bore pipes single socket in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) 75 mm bore pipes single socket in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F stack clamps for 110 mm bore of pipe made out of 50mmx5mmx5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stay to wall or roof etc with PCC (1:2:4) type B-1 of 100x100x100mm complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core all as specified & directed .
Supply and laying sub class 'B' bricks (Old Size) laid flat in trenches as cable covers all as specified and directed
S& F Pipes galvanized iron , “Light Grade ”, complete including fittings 40 mm dia all as specified & directed .
M& L for boring holes (manually) under road ,hard standing,without damaging surface for 40 mm dia GI pipe etc complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
S&F in replacement of Factory made epoxy powder coated Vertical load line distribution boards (VTPN) 6 ways 415 Volt grade with doubled door with acrylec top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar netrual bar standard DIN rail. Earth bar and cable ties for cable manangement . top and bottom removable gland plates with Knockouts complete all as specified and directed (Make Legrand/L&T/ABB) Note: MCB/MCCBs shall be measured and paid seperatly under respective item of this schedule
M& L in replacment of sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 6.0 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
S&F in replacment of factory made epoxy coated Distribution Board SPN 8 Ways 240 volt grade ( SPN MCB DB) with double door ( IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar , neutral bar , standard DIN rail , Earth bar and cable ties for cable management , top and bottom removable gland plates with knockouts complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles & Neutral and current carrying capacity 40 to 63 AMP, in the MCB DB Complete with connection testing and commissioning.
S& F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA all as specified & directed .
Taking down carefully aluminium batten point, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv) Exhaust fan and ceiling fan shall be taken down in under separate item of this schedule.
M & L for point wiring with PVC insulated, PVC unsheathed cable single core, nominal area 1.5 sq mm FR with stranded copper conductor 1100 volts grade drawn into and incl rigid PVC conduit (concealed) 19 mm internal dia with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sq mm unsheathed copper conductor earth wire connected to earth dolly incl metal junction box ,grid plate,base plate suitable for modular switches, sockets, regulators. Note- (1) The rates of chase cutting on wall concealing conduit and steel terminal boxes are included in the unit rates.(2) colour code of wire will be strictly followed , Red for Phase , Black for neutral and green for earth wire(3) Switches & sockets shall be measured and paid for separately.
One light/fan/bellpoint controlled by one switch single pole one way
All as per item No. 106 here-in-before but one 3 pin 5 amp switch socket out let independent .
All as per item No -106 here inbefore but one 3 pin 5 amps socket outlet on the same board with other switch complete .
All as per item No. 106 here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4.0 sq mm size as earth conductor for one 16 amp switch socket outlet on independent board.
Supply and fix switch modular flush 6A single pole one way ISI marked (One module)
Supply and fix switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked
Supply and fix modular sockets 6 Amp 2 in 1 2/3 pin combined (Two module)
Supply and fix modular sockets 16 Amp 2 in 1 3/5 pin combined (Two module)
Supply and fix ceiling rose surface bakelite 60x25mm three terminal
Supply and fix electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type
Supply and Fix calling bell AC ding dong 220 volt multi music type as specified and directed.
Supply and fix Modular bell push AC 220 volt single phase
M& L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4.0 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Supply and fix AC starter unit consisting of one 240 volt 25 Amp 10 KA MCB, one 25 Amp sockets and one 25 Amp plug top prewired cmplete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
S&F of Fresh air fan, single phase 230 volts of size 250 mm sweep, plastic body with louvers and making of hole & grouting nut & bolts and connecting with 3 run of 1.5 sqm, multicore, PVC insulated copper cable from ceiling rose and making good the disturbed surface with existing colour matching complete. Note :- Fan shall be of Make-Bajaj/Havells/CG/Usha
Supply & fix ceiling Fan ,230 Volts, 1200mm sweep,340 RPM, 210 CMM,230 volts,50 Hz, single phase,star rated complete with all accessories for hang and connecting with 3 run of 1.5 sqm, multicore, PVC insulated copper cable from ceiling rose as specified and directed.
Taking down carefully existing ceiling fan and M&L for rifixing the same with nuts, with lock type split pin spring & plate washers etc after paining and oiling/greesing as specified and directed.
supply and fix connecting and testing LED street light 35 watt 6000k new generation energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high efficient led as lighting source and PC cover having toP opening seperate driver compartment with IP66 protection and impact resistance of IK07 roadway luminaries with high power LED as light source and electronic driver complete with connection and accessories for fixing with with including grade 40mm dia GI pipe as bracket in appropriate length complete including taking down old light fitting Note - fitting shall be make Crompton/Philips/Bajaj/Havells
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size10 sq mm 2 core all as specified & directed .
S&F in replacment of factory made epoxy coated Distribution Board SPN 4 Ways 240 volt grade ( SPN MCB DB) with double door ( IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar , neutral bar , standard DIN rail , Earth bar and cable ties for cable management , top and bottom removable gland plates with knockouts complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles & Neutral and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
M/S SURISONS
Aditi Construction Company
HIMANSHU TRADERS
M/S SATISH KUMAR
M/S SWASTIK BUILDERS
oasis contractor builder and supplier
K R GUPTA AND SONS
Krishna Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .