Loading…
Loading…
Tender Value
₹26.4 L
EMD Value
₹52,800
Closing Date
21 Aug 2026, 5:30 pmClosed
Karnataka Power Transmission Corporation Limited
Srinivas T
Replacement of existing age old/sluggish BHEL make 15 Nos of 11kV, 20kA Switchgears(MCVCB) by 11kV 31.5kA Switchgears (MCVCB) at 66/11kV Vijayanagar S/s, Mysuru District & Taluk.-Others- CALL5
KPTCL/2025-26/SS/WORK_INDENT3284/CALL-3
KPTCL/2025-26/SS/WORK_INDENT3284/CALL-3
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CEE Transmission Zone Office Mysuru
13 documents required · 13 mandatory
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Proposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)
Mandating satisfactory completion as a prime contractor for at least one similar work of value not less than 25% of the cost of the contract. (Proceedings of the Government of Karnataka & Government order No. FD480EXP-12/2014 Bangalore dated 19.07.2014)
The Bidder shall be registered firm as Sole Proprietorship/Partnership/Pvt Ltd Company etc
For other than proprietorship, the Bidder shall furnish the registered partnership deed and Power of Attorney
valid Super grade Electrical Contractor License issued by the Government of Karnataka as on the date of opening of techno-commercial bid (refer 2.3 of ITT)
Minimum Average Annual Turnover (MAAT) of the bidder for best one(01) year out of last preceding five financial years, shall not be less than Amount Put to Tender as per 3.2(a) of std tender documents(ITT).
Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under:Assessed Available Tender Capacity: (AxNx5-B)Where A-Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years (updated to FY 2024-2025) taking into account the completed as well as works in progress. N-Number of years prescribed for completion of the works for which tenders are invited.B-Value, at FY 2024-2025 price level of existing commitments (KPTCL & Non-KPTCL)and on-going works (KPTCL & Non-KPTCL) to be completed during the next 1(One)year.Note:(i)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.(ii)A self-declaration is to be uploaded by the Tenderer stating that the information with regard to assessed available tender capacity (Works on Hand) furnished are correct.
Even though the Tenderers meet the above criteria, they are subject to be disqualified if they have:- Made misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements and/or- Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc. and/or- Participated in the previous Tender for the same work and had quoted unreasonably high Tender prices and could not furnish rational justification.
Bidder shall ensure that soft copies of Power of Attorney, Letter of Undertaking, No Deviation CERTIFICATE as revised in Annexure , Any other undertaking / agreement (if applicable) are to be uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date as per 3.10(xviii) of ITT
Bidder shall ensure that soft copies of i. Letter of undertaking for Non performance ii. Letter of undertaking for Risk and Cost iii. Letter of undertaking for Litigation iv. Letter of undertaking to source the supply of equipment material from KPTCL approved Vendors only (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date as per 3.10(xviii) of ITT
Letter of undertaking to source the equipment/material for the work from the approved Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India (Annexure-XVI) ii. Letter of undertaking as per clause No.1.5 of Annexure-XVII iii. Letter of undertaking as per clause No.1.6 of Annexure-XVII (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids
ESI certificate
EPF Certificate
Shall upload valid GST Certificate and PAN copy
₹660
₹52,800
4 Sept 2026
29 Jul 2026
24 Aug 2026
13 Aug 2026
13 Aug 2026
12 Aug 2026
Replacement of existing age old/sluggish BHEL make 15 Nos of 11kV, 20kA Switchgears(MCVCB) by 11kV 31.5kA Switchgears (MCVCB) at 66/11kV Vijayanagar S/s, Mysuru District & Taluk.-CALL3-CAT-2A
LTAC panel (Indoor), 415V as per technical specification
DC Distribution Panel (Indoor)
100A, SFU-01 No. (2) Outgoing 32A, SFU-15 Nos
LT Distribution box for 100 kVA
with LT Protection Kit
4 Core x 16 sqmm Copper Control cable
2 Core 16 Sqmm Copper control cable
4 Core x 6 sqmm Copper Control cable
4 Core x 25 Sq mm Copper control cable
4 Core x 2.5 Sq mm Copper control cable
19 core x 2.5 sqmm Copper Control cable
25,16,6,2.5, sqmm lugs for Copper Control cable
50,25,75 mm Glands for Copper Control cable
Multi Function Transducers(MFT)
Terminal Blocks (knife type)
2.5 Sq-mm multistrand copper wire for CT termination
2.5 Sq-mm multistrand copper wire
10 Copper core x 1.5sqmm Control Cable
10 core x 0.5sqmm Copper cable
1.5 Sqmm Grey wire
tinned copper lugs and crimping and wiring
C-type channel of size 50x100x50x6mm
heavy duty cable glands suitable for UG cable of 1.1 KV class
Replacement of existing age old/sluggish BHEL make 15 Nos of 11kV, 20kA Switchgears(MCVCB) by 11kV 31.5kA Switchgears (MCVCB) at 66/11kV Vijayanagar S/s, Mysuru District & Taluk.-CALL3-CAT-2A
Erection and Commissioning of 11 kV switch gear of type MCVCB, 500 MVA, 31.5kA, 1600A
Testing & commissioning of switch gears
Erection of LTAC panel (Indoor), 415V
Testing & commissioning of LTAC panel (Indoor)
Erection of DC Distribution Panel (Indoor)
Testing & commissioning of DC distribution panel
Erection and commissioning of LT Distribution box for 100 kVA with MCB With LT Protection Kit
Supply & Laying 4 Core x 16 sqmm Copper Control cable
Supply & Laying
2 Core 16 Sqmm Copper control cable
Supply & Laying
4 Core x 6 sqmm Copper Control cable
Supply & Laying
4 Core x 25 Sq mm Copper control cable
Supply & Laying
4 Core x 2.5 Sq mm Copper control cable
Supply & Laying
19 core x 2.5sqmm Copper Control cable (New Cable)
Loading and Unloading
a) Loading of Control Cable available at Store
b) Unloading at Site
if Materials availed from store stock
Transportation of Cable from Store and Returing of released materials to store
Multi Function Transducers(MFT)(For SCADA REINTEGRATION Purpose)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: ...
Opto Coupler(For SCADA REINTEGRATION Purpose)
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5m...
Control Cable(For SCADA REINTEGRATION Purpose) - 10 Copper core x 1.5sqmm
(From remote contol desk to RTU)
(17mtrs x 12 nos = 204 mtrs)
Signal Cable(For SCADA REINTEGRATION Purpose) - 10 Copper core x 0.5sqmm
Feeder to Feeder loop = 05mts x 1 nos =05 mtrs)
Remote control desk to RTU (for DI):17mtrs x 12 Nos =204 mtrs
RTU to B1&B2+Fee...
1.5 Sqmm Grey wire for interfacing of DI and DO(For SCADA REINTEGRATION Purpose)
(20 mtrs for each panel)(20x15=300mtr)
CT TB's - 6 nos for each panel
(1 x 6 = 6 nos)(For SCADA REINTEGRATION Purpose)
Miscellaneous items like, Ferrules, cable ties, insulation tape, & Labour for cutting, weldind, drilling, etc(For SCADA REINTEGRATION Purpose)
Configuration of RTU and Engineering along with validation of data at SLDC(For SCADA REINTEGRATION Purpose)
Grounding of equipment with 50 x 6 mm G.I. Flat and connecting Equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and conn...
Decomissioning of existing 11kV Indoor / Outdoor Switchgear.
Decomissioning of existing 11kV Adaptor panel
De- wiring 11kV Indoor/Outdoor Switchgear
Releasing of unarmourd control cable
Decomissioning of detoriated Non Standard LTAC distribution(Indoor) panel
Decomissioning of detoriated Non Standard DCDB panel
Decomissioning of detoriated outdoor LT Distribution Box of 100KVA Auxilliary Transformer
Loading of 11 kV Switchgears other cable and materials
(Loading at Vijayanagara S/s)
Unloading of 11 kV Switchgears other cable and materials
(Unloading at KPTCL store, Hootagally)
Transportation of released Breakers etc from 66/11kV Vijayanagara S/s to Divisional store, Hootagalli Mysore.
Station to weigh bridge and store vice versa
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
02 NIT -Vijayanagara Call5.pdf
Instructions to Tenderers • 0.66 MB
Volume II A B.zip
Technical Information / Worksheet • 19.19 MB
Tender document Kw2G -Vijayanagara Call5.pdf
Tender Document • 2.22 MB
Work on Hand details format.pdf
Techno-Commercial Worksheet • 0.17 MB
credit facility certificate-FORMAT toUL.pdf
Commercial Information / Worksheet • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .