Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC KHUKURANI MANDAL | MEDINIPUR EAST | WEST BENGAL | 721130 | ₹1.5 L | L1 | Accepted-AOC Stand First Lowest, hence accepted. |
| 2 | L2₹1.5 L+₹715 (0.48%)Rejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | ₹1.5 L+₹715 (0.48%) | L2 | Rejected-Finance Stand Second Lowest |
| 3 | L3₹1.6 L+₹14,057 (9.45%)Rejected-Finance 869 0 NIVEDITA PALLY NAIHATI NORTH 24 PARGANAS | NAIHATI | NORTH 24 PARGANAS | WEST BENGAL | 743165 | ₹1.6 L+₹14,057 (9.45%) | L3 | Rejected-Finance Stand Third Lowest |
| Sl No | Description | Qty | Unit | M/S R. K. ENTERPRISE L2 | DEPALI CONSTRUCTION L3 | KAR ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery of split Air-conditioner machine having cooling capacity not less than 6900W, ISSER 3.8 to 4.39, BEE rating not less than 3 star, Noise level not more than 50 db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A. (O-General/ Hitachi/ Daikin/ Mitsubhisi Electric/Mitsubhisi Heavy Industries ). | 1 | No | 44,500 ₹44,500 Lowest | 49,500 ₹49,500 | 46,500 ₹46,500 |
| 2.00 | Installation, testing & commissioning of the above-said split Acs incl supply & fixing required angle iron structure on wall for placing outdoor unit & mending good the damages. | 1 | No | 1,500 ₹1,500 Lowest | 1,800 ₹1,800 | 1,650 ₹1,650 |
| 3.00 | Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including wrapping tape,shaddle,screw, insulation tape, fastner etc for above AC machine. | 30 | Mtrs | 780 ₹23,400 | 850 ₹25,500 | 760 ₹22,800 Lowest |
| 4.00 | Supply & Laying of 4 core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/Polycab) | 35 | Mtrs | 120 ₹4,200 Lowest | 175 ₹6,125 | 150 ₹5,250 |
| 5.00 | Supply &Laying 3/4"(20mm) hard PVC pipe(heavy type)for water drainage. | 30 | Mtrs | 50 ₹1,500 | 48 ₹1,440 | 40 ₹1,200 Lowest |
| 6.00 | Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 3.0/4.0 TR ceiling concealed AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access. | 1 | No | 5,400 ₹5,400 | 710 ₹710 | 600 ₹600 Lowest |
| 7.00 | Supply & laying 1.1 KV grade 3 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from starter to A.C outdoor Connection)(make: Havels/KEI/Polycab/Finolex) | 30 | Mtrs | 180 ₹5,400 Lowest | 240 ₹7,200 | 190 ₹5,700 |
| 8.00 | Supply & fixing automatic single phase AC starter of 21Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand) to be fixed on wall with all fixing accessories complete as to G.S | 1 | Each | 1,200 ₹1,200 Lowest | 1,650 ₹1,650 | 1,600 ₹1,600 |
| 9.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene / PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1] 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ E-9/1(v)] | 200 | Mtr | 99 ₹19,800 | 95 ₹19,000 | 85 ₹17,000 Lowest |
| 10.00 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. (E-16 / 7) ii) 25 mm size | 200 | Mtr | 60 ₹12,000 Lowest | 75 ₹15,000 | 70 ₹14,000 |
Tender Value
Refer Docs
EMD Value
₹2,990
Closing Date
19 Nov 2025, 12:30 pmClosed
Assistant Engineer, P.W.Dte. High Court Elecl. SD
Office of the Assistant Engineer, P.W.Dte. High Court Electrical Sub-Division,1st Floor, Sesqui-Centenary Building, High Court, Calcutta, KOLKATA 700001
Supply and Installation of Split type AC machine within the Chamber of Deputy registrar (Administration), Ground Floor, Near B Gate of Main Building of the Honorable High Court, Calcutta.
2025_WBPWD_935289_1
WBPWD/AE-HCESD/NIQ69/2nd/25-26
Open Tender
ELECTRICAL WORKS M/R
Item Rate
7 days
High Court Electrical Sub-Division PWDte.
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,990
19 Sept 2026
31 Oct 2025
21 Nov 2025
31 Oct 2025
19 Nov 2025
31 Oct 2025
Amount
Supply & delivery of split Air-conditioner machine having cooling capacity not less than 6900W, ISSER 3.8 to 4.39, BEE rating not less than 3 star, Noise level not more than 50 db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A. (O-General/ Hitachi/ Daikin/ Mitsubhisi Electric/Mitsubhisi Heavy Industries ).
Installation, testing & commissioning of the above-said split Acs incl supply & fixing required angle iron structure on wall for placing outdoor unit & mending good the damages.
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including wrapping tape,shaddle,screw, insulation tape, fastner etc for above AC machine.
Supply & Laying of 4 core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/Polycab)
Supply &Laying 3/4"(20mm) hard PVC pipe(heavy type)for water drainage.
Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 3.0/4.0 TR ceiling concealed AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access.
Supply & laying 1.1 KV grade 3 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from starter to A.C outdoor Connection)(make: Havels/KEI/Polycab/Finolex)
Supply & fixing automatic single phase AC starter of 21Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand) to be fixed on wall with all fixing accessories complete as to G.S
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene / PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1] 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ E-9/1(v)]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. (E-16 / 7) ii) 25 mm size
S&F of 32A timer controlled DB for 1 no. single phase AC in SS double door 12 way DB enclosure (Make: L&T/Legrand/ABB(E)) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish. All connections should be made by copper wire of 4mm2 & 1.5mm2 and finishing with dowells solderless socket by crimping method incl. necy. connection & provision for earthing attachment incl. Ferruling & marking with S&F following Electrical accessories as per direction of EIC [for 2/1.5 TR AC] i) 240V, 32A DPMCB C curve breaking capacity 10kA - 1 no. ii) 240V, 22A, 2P Contactor with Auxilary Contact - 1 no. iii) 25A, 250V AC ON-OFF-ON SPDT toggle switch with marking-1no. (for Auto/Manual option). iv) 24Hr x 7 days programmble Digital timer - 1 no. v) On & Off Indicator LED lamp and Start & Stop push button switch (G&R)-2 set. vi) Din rail mounted Terminal Block for Outgoing & Incoming - 4 nos. vii) 6-32 A SP MCB C curve breaking capacity 10kA-1 no.
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
M/S R. K. ENTERPRISE (BID ID -7269655)
DEPALI CONSTRUCTION (BID ID -7254451)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .