Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹16.1 L+₹3.3 L (25.7%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹16.9 L+₹4.1 L (32.3%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹17.4 L+₹4.6 L (36.1%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹18.5 L+₹5.7 L (44.4%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
30 Sept 2021, 6:00 pmClosed
GE EAST AGRA
GE East Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt 282001
REPAIR MAINT OF LT OH LINE CONDUCTOR INSULATOR, STAY AND CONNECTED WORK WEST AREA UNDER GE EAST AGRA
2021_MES_468154_1
9379/E8
Open Tender
Civil Works
Item Rate
270 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹44,000
Yes
29 Oct 2021
14 Aug 2021
11 Oct 2021
14 Aug 2021
30 Sept 2021
29 Aug 2021
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays complete all as specified and directed.
-Ditto- but depth exc 1.5 mtr but not exc 3.00 mtr
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.
M&L for Sub class ‘B’ old size bricks for cable protection laid dry flat over the cable complete all as specified and directed..
Laying only Sub class ‘B’ old size bricks retrieved against srl item 1 here in before for cable protection laid dry flat over the cable complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work etc complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1 ( using 20mm graded stone aggregate ) in coping of poles studs including form work etc complete all as specified and directed.
Taking out from trenches or wall/ pole or pipe cable LT 1100 volts grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size upto 25 Sqmm , any core , for rectification of faults or replacement. Seggregating serviceable cable and unserviceable lenght by meggering or any other suitable and recommended method. Removing unserviceable from site and keeping aside serviceable for reuse at same location or any other location under AGE E/M all as rquired at site or directed. (Earth work will be measured and paid separately under respective item).
All as per Srl Item 10 here in above but of size 35 Sqmm to 95 Sqmm
Laying only in trenches or fixed to wall/pole or passing through pipe cable LT 1100 Volts grade heavy duty, armoured with aluminium conductor of any size upto 25 Sqmm any core. (Serviceable cables retrieved against srl item 10 above will be used).
All as per Srl Item 12 here in above but of size 35 Sqmm to 95 Sqmm (Serviceable cables retrieved against srl item 11 above will be used).
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 16 Sqmm 2 core including taking down old cable complete all as specified and as directed.
All as per item No 14 here-in-before but of size 25x 3.5 sqmm
All as per item No 14 here-in-before but of size 50x 3.5 sqmm
All as per item No 14 here-in-before but of size 95x 3.5 sqmm
All as per item No 14 here-in-before but of size 150x 3.5 sqmm
All as per item No 14 here-in-before but of size 400x 3.5 sqmm
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 sqmm 3½ core core with working voltage 1100 volts complete all as specified and as directed. make: Raychem/Denson/ M Seal.
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 sqmm 3½ core core with working voltage 1100 volts complete all as specified and as directed.make: Raychem/Denson/ M Seal.
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 185 Sqmm to 300 sqmm 3½ core core with working voltage 1100 volts complete all as specified and as directed.make: Raychem/Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 Sqmm3½ core core with working voltage 1100 volts complete all as specified and as directed.make: Raychem/Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 Sqmm3½ core core with working voltage 1100 volts complete all as specified and as directed.make:Raychem/Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 185 Sqmm to 400 Sqmm3½ core core with working voltage 1100 volts complete all as specified and as directed. make: Raychem/Denson/ M Seal.
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 80/40 mm bore GI tubing of any description below/under existing road surfaces / floors at a level not less than 0.60 mtr etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed. Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt. (ii) GI Pipe 40 mm will be measured and paid separately
M & L for GI pipe light grade 80 mm dia with all fitting laid in bore holes/trenches/drian/culvert or fixed along with pole/wall including 02 Nos FI clamps of 25x3 mm including nut, bolts etc. complete all as directed. Make of GI pipe : Tata/Jindal
M & L for GI pipe light grade 40 mm dia with all fitting laid in bore holes/trenches/drian/culvert or fixed along with pole/wall including 02 Nos FI clamps of 25x3 mm including nut, bolts etc. complete all as directed. Make of GI pipe : Tata/Jindal
Material and labour for GI tubing light grade 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
Taking down carefully aluminium conductor of any size from LT OH Lines after unbinding from insulators for replacement of multijointed / undersize conductors.
M&L for ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed.
Restringing and restretching aluminium conductor including necessary binding with insulators using alunimium binding wire, connections of incoming and out going cables complete all as specified and directed.
Restretching aluminium conductor or GI wire on existing over head lines without removing including unbinding from insulator and rebinding to insulator using aluninium binding wire , connections of incoming and out going cables, binding with spacers where required, complete all as specified. (Note ;- For measurement length of each conductor shall be taken seperately.
M&L in replacement for GI wire 4mm dia drawn straight horizontal as continuous earth wire on poles or fabrication of cradles complete all as specified and directed.
M&L in replacement aluminium strip of any size cut to length as required at site including drilling holes, bend to shape for repairing of LT panels/GOD'S complete all as specified and directed.
M&L in replacement copper strip of any size cut to length as required at site including drilling holes, bend to shape for repairing of LT panel/ GOD switches complete all as specified and directed.
M&L in replacement shackle type insulators of 100mm high, 115mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified and directed.
M&L in replacement pin insulators 75 mm height and 90mm dia size porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed.
M&L for stay assembly using GI stay rod 20mm dia complete with stay plate mild steel of size 300x300x6.00mm thick, stay bow complete all as specified and shown in Electrical Plate No 1 . including taking out old unserviceable stay assembly (Necessary earth work, stay wire, loop insulator,clamps and PCC shall be measured and paid seperately) complete all as specified and directed.
M&L in replacement Galvanised stay wire of size 7/4mm complete all as specified and directed.
M&L in replacement loop type insulator large size porcelain vitirious of size 90 x 140 mm clearence of hole 16mm complete all as specified and directed.
M&L for steel tubular swaged pole 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative green & white strips of 30 cm width upto 1.5 mtr above ground level, balance lenght to be painted with two coats of aluminium paint externally including taking out old steel pole coplete all as specified and directed.
Supply and fixing in replacement MCCB having current ratings 63 Amps with rupturing cap 16 KA , AC 415 Volts four pole with thermal release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make Legrand/C&S/Havells/Siemens
Supply and fixing in replacement MCCB having current ratings 100 Amps with rupturing cap 16 KA , AC 415 Volts four pole with Thermal release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make Legrand/C&S/Havells/Siemens
Supply and fixing in replacement MCCB having current ratings 160 Amps with rupturing cap 25 KA , AC 415 Volts four pole with Thermal release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make Legrand/C&S/Havells/Siemens
Supply and fixing in replacement MCCB having current ratings 250 Amps with rupturing cap 25 KA , AC 415 Volts four pole with Thermal release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make Legrand or equivalent of make /C&S/Havells/Siemens
Supply and fixing in replacement MCCB having current ratings 400 Amps with rupturing cap 36 KA , AC 415 Volts four pole with Thermal release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make or equivalent of make Legrand /C&S/Havells/Siemens
Supply and fixing in replacement MCCB having current ratings 630 Amps with rupturing cap 50 KA , AC 415 Volts four pole with Thermal release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make or equivalent of make Legrand /C&S/Havells/Siemens
Removing all connections from LT panel having feeders upto 04 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, for repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice. ( U/S items will be provided against respective items separately.
Supply and fix in replacement epoxy based post insulators LT 440V for mounting bus bar complete all as specified and directed.
Supply, installation , Commissiong and Testing of Lead Acid SMF VRLA Battery Bank of 220 Volt 100 Ah consisting of 110 Nos cells of 02 Volts 100 Ah capacity each complete with Inter cell connector, SS nut bolts and washers , MS Power coated stand factory made complete including taking out old u/s battery bank complete all as specified and directed. Make : Exide/HBL/Amron Note:- For payment Each cell of 02 volts shall be measured and paid. Contractor shall quote the rate of each cell of 02 volts .
AUTOMATION AND SWITCHGEAR PANELS
LUCKY SALES CORPORATION
Balaji Associates
M/S JAI JAGDAMBEY TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .