| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹49.8 L+₹3.0 L (6.38%)Rejected-AOC PLOT NO 4 SUDARSHAN ROW RESIDENCY GAWADE MALA PIPELINE ROAD SAVEDI AHMEDNAGAR 414003 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414003 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹57.2 L+₹10.4 L (22.3%)Rejected-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-AOC Rejected |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
25 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of certain sanctioned works (01) in the area of AGE EM (N) under GE (N) Ahmednagar
2021_MES_460075_1
8553 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat b(ii)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹97,000
Yes
9 Sept 2021
16 Jul 2021
27 Aug 2021
16 Jul 2021
25 Aug 2021
30 Jul 2021
60 days
Amount
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor of size 3.5 core 240 sqmm etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 01 (here-in-before) but 185 Sqmm 3.5 core.
All as per item No. 01 (here-in-before) but 95 Sqmm 3.5 core.
Dismantling existing Transformer 100 KVA ,11KV/433 volts from existing place (BTR) by disconnecting of HT & LT connections and taking down with the help of crane, transport and depositing in MES Store etc complete all as specified and directed by Engineer-in-Charge
Supply, installation, testing and commissioning of outdoor, AC three phase , 50 HZ, 250 KVA capacity transformer step down , out door type 11000/433Volt (at No Load) copper wound , oil immersed , naturally cooled with external cooling tubes, core type delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol Dyn-11/vector group-4) with neutral brought on secondary (LV ) Side & having tapping in equal steps of 2.5% from (+) 5% to (-) 7.5% on primary side by means of hand operated on load tap changer /correct LT voltage on secondary side including provision of all necessary / standard fittings mainly comprising etc complete all as specified and directed by Engineer-in-Charge (a) One cable box on primary HV side having cable glands suitable for 3 core 150 sqmm XLPE 11 KV HT Cable consisting of 03 Nos of porcelain HT bushing with brass/gun metal bushing rods complete with nuts, bolts and washers. (b) One cable box on secondary (LV) side consisting of 04 Nos porcelain bushing with GM bushing rods complete with GM nuts, bolts and washers with one No of cable gland suitable for reception of out going LT PVC sheathed armoured cables of size 3.5 Core 240 sqmm.
(c ) Oil conservator with filter type , drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e ) Explosive Vents (f) Thermometer pocket on tank cover. (g) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centegrade with temp reading pointer, max temp indicator and resetting device. (h) Rating plate with terminal markings. (j) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6mm GI Earth strip. (k) Oil Level gauge. (l) Oil Drain and filter valve (m) Oil filter hole with cap/plug with connections complete. (n) Lifting Lugs (o) Air Relief valve plug (p) Four plain solid cast steel detachable rollers. (q) First fill of fresh oil conforming to relevant IS-335 and tested upto 40 KV dielectric strength. (r) Extra bushing for neutral outside the LT cable box for providing independant earthing for neutral. (s) Provision of 02 Nos of danger board 250x200mm size made out of 1.6 mm thick MS Plate, vitreous enameled white with letters, figures in marathi, Hindi and english of voltage and conventional skull and bones in signal red colour , one at HT side and other on LT side .
(t) Rate include for transformer plinth (size 1200 mm x 1200 mm x 1000 mm) with brick work in coment and sand mortar (1:4) cement concrete (1:2:4) using graded stone aggregate and plasterig in cemnet and sand mortar (1:4) and Supply and fixing FRP fencing made up with using FRP rod 12 mm dia, channel size 50 x 24 x 4 mm box section 50 x 25 mm "I" section 38 x 15 x 3 mm and square box section 50 x 50 mm in post embedded in plain cement concrete (1:4:8) type D2 using 20 mm graded stone aggregate (45 cm x 45 cm x 45 cm) includig necessary excavation and eathwork at 1.25 m C/C with height of fening 2 m from GL including entrance gate of size 1 m x 2m of same material. MS aldrop bolt 300 mm long 150mm size pressed streel handles and 2 Nos tower bolts MS hinges as required etc complete all as specified and directed by Engineer-in-Charge. Note : Vertical posts and rail section shall be manufactured of fibre glass reinforcement min 45% and formulation of polystrbased thermoset resign. (u) Any other fittings /accessories so as to conform the whole transformer to IS-2026. Make of Transformer : Schneider / Kirloskar / ABB / BHEL / Voltamp Ltd, Baroda / Uraj techniques / Indian transformer, Gurgaon / Pactil. (v) Buccholz relay to identify the fault : (a) Protection for a transformer against internal faults. (b) Protection of transformer against external faults (c) Protection for transformer against induction motors faults.
Supply and laying in replacement of cable XLPE insulated armoured & PVC beded, galvanised steel strip or wire armoured electric power cables heavy duty HT 11000 Volt grade with aluminium conductor of size 150 Sqmm 3 core etc complete all as specified and directed by Engineer-in-Charge
S&F in vertical type air break switch, gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to work from ground, including locking arrangements, suitable for 11000 volts, 400 Amps current rating complete including dismantling existing one etc complete all as specified and directed by Engineer-in-Charge
S&F of HT 11 KV out door non-linear type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure / GI flat strip and connect with same size of ACSR encashed in PVC alkathine pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge capacity of 65 KA and rupturing capacity 5 KVA and suitable for working pressure 9 KV RMS compelete including taking down old lightning arrestor all as specified and as directed including dismantling existing one etc complete all as specified and directed by Engineer-in-Charge
S&F drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washers etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one etc complete all as specified and directed by Engineer-in-Charge
M&L for earthing of poles/system with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick buried vertically in ground not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to GI strip 32x6 mm by means of nuts, bolts and washers and encased in and including 40mm dia GI medium grade pipe upt 2.4 mtr height form ground level fixed by MS flat iron clamp 40mm x 5mm with nuts, bolts and washers, GI strip fixed to base along pole and connected to over head line for providing earthing to HT pole/feeder AB switch LA complete with charcoal dust, salt packed around plate 150 mm thick including watering GI pipe, medium grade 40 mm dia with blanking cap 1.5 mtr long fixed to funnel with wiremesh complete with PCC chamber and RCC chamber over all as per Electrical Plate No 3 of SSR Part I - 2009 including excavation and earth work in any type of starta and testing on compeltion. (Note: Rate of GI strip and 40 mm dia GI medium grade pipe upto 7.5m length is included in the quoted rate of earthing
M & L for GI Strip 32mmx6mm burried in ground or Tubular pole by nuts , bolts and washers and suitable size of clamp etc complete all as specified and directed by Engineer-in-Charge
M & L for cable jointing kit end termination for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm, 3 core etc complete all as specified and directed by Engineer-in-Charge
S&F in repairs galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standered rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc as directed(each line of wire to be measured) etc complete all as specified and directed by Engineer-in-Charge
Incomming:- (a) MCCB 400Amp 4 Pole breaking capacity 50 KA with adjustable O/L thermal magnetic adjustable type thermal setting 70-100% & magenetic adjustable 5-10 time AC 415 Volt, 50 Hz conforimg to IS : 13947-3 releases-01 No
Out Going:- (a) MCCB 250 Amps TP, 35 kA MCCB with fixed neutral and S/C & adj .O/L thermal magnetic releases.-01 No (b) MCCB 200 Amps TP, 25 kA MCCB with fixed neutral and S/C & adj .O/L thermal magnetic releases.-02 Nos Note : Min size of LT Panel is 1200x600x1000mm
M&L for GI pipe light grade 50 mm dia Tubes, with all fitting and fixed complete to walls and ceilings or laid in floors etc complete all as specified and directed by Engineer-in-Charge
All as per Item No 19 (here-in-before) but 80 mm dia
Excavation in trenches not exc 1.5 meter wide and not exc. 1.5 mtr in depth for laying of under ground cable, pole foundation and stays etc and getting out in hard / dense soil etc complete all as specified and as directed by Engineer-in-Charge.
Returning and filling in, including spreading and levelling, water and well remming in layers not exc. 25cm etc complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point etc complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and replcement of PCC covers , class HV type-1 flat size 300x180x40mm, etc complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and replcement of PCC covers , class LV type-2 flat size 250x150x40mm, etc complete all as specified and as directed by Engineer-in-Charge.
Supply and spread unwashed dry river / crused sand cushioning and covering the under ground cable in trenches etc complete all as specified and as directed by Engineer-in-Charge. Note : Punning thickness shall be measured)
Dismantling existing Transformer of 250 KVA capacity from HCOM area by disconnecting of HT & LT connections and taking down with the help of crane, transport and carrying and deposit to MES Store.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor of size 400 sqmm of 3.5 core and etc complete all as specified and as directed by Engineer-in-Charge.
Incoming Supply & fix ACB 4 poles, 415 V, with thermal magnetic release (Manual fixed type) of capacity 800 Amps complete all as specified and directed by Engineer-in-Charge. Outgoing (a) MCCB 400 Amp TP, 35 KA MCCB with fixed neutral and S/C & adj O/L thermal magnetic releases - 01 No (b) MCCB 250 Amp TP, 25 KA MCCB with fixed neutral and S/C and adj oil thermal magnetic releases - 03 Nos Note : Minimum size of LT panel is 1200 mm x 600 mm x 1000 mm
Supply, laying, testing & commissioning of HT 11 KV (earthed) XLPE insulated screened PVC bedded electric power cable(heavy duty) with aliminium conductor 11000 Volts grade, circular screened with extruded semi conducting compound in combination with copper tape, inner sheath of PVC tape galvanised steel strip flat, around and oveall PVC shheathed armourded conforming to IS 7098 Part-II, 1985 amended upto date of size 3 core 120 Sqmm, ISI marked laid in trenches or passing through pipes/ducts including taking down old cable of any size etc complete all as specified and as directed by Engineer-in-Charge.
M& L for end termination joint kit for 11 kv grade cable heat shhrinkable joint, in door suitable for XLPE armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core, 120-185 Sqmm etc complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of outdoor, AC three phase , 50 HZ, 500 KVA capacity transformer step down , out door type 11000/433Volt (at No Load) copper wound , oil immersed , naturally cooled with external cooling tubes, core type delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11/vector group-4) with neutral brought on secondary (LV ) Side & having tapping in equal steps of 2.5% from (+) 5% to (-) 7.5% on primary side by means of hand operated on load tap changer /correct LT voltage on secondary side including provision of all necessary / standard fittings mainly comprising etc complete all as specified and as directed by Engineer-in-Charge.
(a) One cable box on primary HV side having cable glands suitable for 3 core 150 sqmm XLPE 11 KV HT Cable consisting of 03 Nos of porcelain HT bushing with brass/gun metal bushing rods complete with nuts, bolts and washers. (b) One cable box on secondary (LV) side consisting of 04 Nos porcelain bushing with GM bushing rods complete with GM nuts, bolts and washers with one No of cable gland suitable for reception of out going LT PVC sheathed armoured cables of size 3.5 Core 240 sqmm. (c ) Oil conservator with filter type , drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e ) Explosive Vents (f) Thermometer pocket on tank cover. (g) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centegrade with temp reading pointer, max temp indicator and resetting device. (h) Rating plate with terminal markings. (j) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6mm GI Earth strip. (k) Oil Level gauge.
(l) Oil Drain and filter valve (m) Oil filter hole with cap/plug with connections complete. (n) Lifting Lugs (o) Air Relief valve plug (p) Four plain solid cast steel detachable rollers. (q) First fill of fresh oil conforming to relevant IS and tested upto 40 KV dielectric strength. (r) Extra bushing for neutral outside the LT cable box for providing independant earthing for neutral. (s) Provision of 02 Nos of danger board 250x200mm size made out of 1.6 mm thick MS Plate, vitreous enameled white with letters, figures in marathi, Hindi and english of voltage and conventional skull and bones in signal red colour , one at HT side and other on LT side . (t) Any other fittings /accessories so as to conform the whole transformer to IS-2026. (u) (v) Buccholz relay to identify the fault : (a) Protection of a transformer against internal faults. (b) Protection of transformer against external faults (c) Protection of transformer against induction motors faults.
(v) Rate include for transformer plinth (od size 1200 mm x 1200 mm x 1000 mm) with brick work in coment and sand mortar (1:4) cement and sand mortar (1:2:4) using graded stone aggregate and plasterig in cemnet and sand sand mortar (1:4) and Supply and fixing FRP fencing made up with using FRP rod 12 mm dia, channel size 50 x 24 x 4 mm box section 50 x 25 mm "I" section 38 x 15 x 3 mm and square box section 50 x 50 mm in post embedded in plain cement concrete (1:4:8) type D2 using 20 mm graded stone aggregate (45 cm x 45 cm x 45 cm) includig necessary excavation and eathwork at 1.25 m C/C with height of fening 2 m from GL including entrance gate of size 1 m x 2m of same material. MS aldrop bolt 300 mm long 150mm size pressed streel handles and 2 Nos tower bolts MS hinges as required etc complete all as specified and directed by Engineer-in-Charge. Note : Vertical posts and rail section shall be manufactured of fibre glass reinforcement min 45% and formulation of polystrbased thermoset resign. (w) Factory inspection : Before despatch of transformer from factory ; The contractor shall inform to GE / Engineer-in-Charge well inadvance for factory inspection of the trasformer by the rep of GE (N) Ahmednagar Make of Transformer : Schneider / Kirloskar / ABB / BHEL / Voltamp Ltd, Baroda / Uraj techniques / Indian transformer, Gurgaon / Pactil.
Taking up or Down PVC tubing and connections from trenches /walls/floors etc cleaning for 150mm bore pipe etc complete all as specified and directed by Engineer-in-Charge.
Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for 50 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for 25 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for 20 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
Supply and fix GI pipes 50mm bore , medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc commplete all as specified and directed by Engineer-in-Charge
All as per serial item No 41 (here-in-before) but 25 mm bore pipe
All as per serial item No 41 (here-in-before) but 20 mm bore pipe
Supply and laying 150mm dia ductile iron pipes(DI) with & including Flange Joints of Two sides of Pipe (5.5 Rm to 6 Rm) centrifugally K-9, etc complete all as specified and directed by Engineer-in-Charge Note:- The pipe accessories like Nuts, Bolts, Washers,Rubber gasket , Flanges etc are included in Rate Quoted.
Supply and laying 100mm dia ductile iron pipes(DI) with & Including Flange Joints of Two sides of Pipe (5.5 Rm to 6 Rm) centrifugally K-9, etc complete all as specified and directed by Engineer-in-Charge Note:- The pipe accessories like Nuts, Bolts, Washers, Rubber gasket , Flanges etc are included in Rate Quoted.
Supply and fix in repairs cast iron sluice valve ,150 mm bore , Class PN1.6, ISI marked with stainless steel spindle, both ends flanged including rubber gasket, nuts, bolts and washers etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 46 (here-in-before) but 100 mm bore pipe
Material and labour in repairs gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for 50 mm bore GI pipe etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 48 (here-in-before) but 25 mm bore pipe
All as per serial item No 48 (here-in-before) but 20 mm bore pipe
Material and labour for run lead joints in old /new pipes / specials for 150 mm bore pipes etc complete all as specified and directed by Engineer-in-Charge
All as per serial item No 51 (here-in-before) but 100 mm bore pipe
Material and labour for Cast iron/ ductile iron specials such bends of any type, radius and angle, tapers any type, straight, bend, increasing, decreasing or double socket etc, tail pices single branch, "Y" junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc suitable for CI / DI pipes class LA upto 300 mm more pipes etc complete all as specified and directed by Engineer-in-Charge
Dismantaling old valve chamber & M & L for Construction of PCC solid block valve chamber including earth work described as under complete all as specified for the following internal size as under : (a)100 mm thick hard core, (b) 100mm thick PCC foundation 1:4:8 type D2 (using 40 mm graded stone aggergate) (c) 200 mm thick block masonary graded C-5 built in cement and sand mortar (1:6), (d) 15 mm internal and external plaster in cement and sand mortar (1:4), (e) 3mm thick MS sheet chamber cover and 50 x 50 x 6 mm thick angle iron frame including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface including locking arrangments etc complete all as specified and directed by Engineer-in-Charge
(a) 1500 mm x 1200 mm x 1000 mm
An amount of Rs 49,850.00 shall be deducted from BOQ on account of schedule of credit
Maruti Abhiyantriki
Paragon Electrotechnics
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .