Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAccepted-AOC | ₹3.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.9 Cr+₹3.9 L (1.01%)Rejected-AOC | ₹3.9 Cr+₹3.9 L (1.01%) | L2 | Rejected-AOC L2 |
| 3 | Not Admitted-Fee/PreQual/Technical C O LT MAAHANTA NARZARY W NO 5 TENGAPARA P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Rejected-Technical | - | - | Rejected-Technical reject |
| 5 | Rejected-Technical BHETAPARA CHARIALI ABOVE UCO BANK GUWAHATI 781028 | GUWAHATI | KAMRUP METRO | ASSAM | 781028 | - | - | Rejected-Technical reject |
Tender Value
₹3.9 Cr
EMD Value
₹7.9 L
Closing Date
19 Feb 2021, 2:30 pmClosed
Sri Hriday Boro
O/o the Addl. Chief Engineer cum Director, PWD,BTC
TN_128_1_R_1 Repairing, Renovation, Colouring and Painting, Approach Road and Boundary wall including Drainage System of Sub-Division Centre, Salbari, Baksa BTC for the year 2018-19.
2021_BTC_21208_1
No. ACE- 82/TECH/IFB/MSLPR/2019-20/14
Open Tender
Civil Works - Building
Item Rate
360 days
Baksa
Please refer Tender documents.
6 documents required · 6 mandatory
₹11,900
The Principal Secretary, BTC, Kokrajhar
₹7.9 L
Yes
4 Dec 2021
13 Feb 2021
19 Feb 2021
13 Feb 2021
19 Feb 2021
13 Feb 2021
13 Feb 2021 - 19 Feb 2021
Amount
(A) Road Work: Clearing and grubbing road land including up rooting rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned, upto a lead of 1000 m including removal & disposal of top organic soil not exceeding 150 mm in thickness as per MORTH specification 201. i) By Manual Means. (A) In area light jungle
Construction of subgrade and earthen shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1 (i) private Land.
Granular Sub-base with Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at omc, and compacting with smooth wheel roller to achieve the desired density complete as per clause Technical specification clause 401. (ii) For Grading II Material.
WBM Grading 3 Using stone screening Type-B 11.2mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means
Retro-reflectorised Traffic Signs Providing and fixing of retro reflectorised cautionary mandatory and informatory sign as per IRC: 67 made of encapsulated lens type reflective sheeting vide clause 170.1.2.3 fixed over aluminium sheeting 1.5mm thick supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mm x 450mm x600mm, 600mm below ground level as per drawings and Technical Specification Clause 801. (i) 90cm equilaterial triangle.
Inter locking concrete Block Pavement I. Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification Clause 1504 a) Including Edge block/Edge restraints
(B) Car Parking With ICBP (80.00 m x 50.00m): Construction of subgrade and earthen shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1 (i) private Land.
Granular Sub-base with Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at omc, and compacting with smooth wheel roller to achieve the desired density complete as per clause Technical specification clause 401. (ii) For Grading II Material.
WBM Grading 3 Using stone screening Type-B 11.2mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means
Inter locking concrete Block Pavement I. Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification Clause 1504 a) Including Edge block/Edge restraints
(C) Construction of Godown: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing brick work soiling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement: 3 sand : 6 coarse aggregate by volume (Using mixture machine)
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall & boundary wall etc.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Colums, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2. Sides and soffits of beams,beam haunchings, cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. a) M15 or Prop 1:2:4
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. a) M15 or Prop 1:2:4
Brick work in cement morter with 1st class brick including racking out joints and dewarting if necessary and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
112mmm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (b) In cement mortar in proporation 1:5
10mm thick cement plaster in single coat on fair side of brick/concrete wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (c) In cement mortar 1:5
15mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. c) In cement mortar 1:5
Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire lenth and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters.
Providing fiting and fixing windows/ventilators (fixed) of standard rolled steel sections as per relevent I.S Code joints mitred and welded with 15mm x 3mm 100m lugs embedded in cement concerte block of M-10 grade inclduing applying a coat of red-lead primer.
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. (b) Using other ISI marked approved brand tube
Providing Pre Painted Galvanized iron sheet roofing (PPGI) at all levels including fitting and fixing with self drilling self tapping screws complete. (Roof truss, purlins etc. to be measured and paid separately.) TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department (ii) 0.45 mm thick
Providing Pre Painted Galvanized iron sheet (PPGI) accessories (Ridges/Valley/Gutter/Flashing) at all levels including fitting and fixing self drilling self tapping screws complete. TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department (ii) 0.45 mm thick
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners............ Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). (i) 9.5mm thick
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With river sand or silt (predominently non plastic) by truck carriage including loading and unloading. (C) With silt (predominantly non plastic) by truck carriage including loading and unloading.
Providing and laying 65mm thick C.C floor with metallic concrete hardener topping under layer of 50mm thick cement concrete in prop 1:2:4 (1 cement: 2 coarse sand: 4 coarse agg. Of 20mm and down) and top layer of 15mm thick of metallic cement hardware consisting of mix 1:2 (1 cement hardware mix 2 stone agg. 6mm and down) by volumn with whichmetallic hardening compound of approved quality is mixed in the ratio of 4:1 (4 parts of cement 1 part of metallic floor hardening compound of approved quality by weight) including finishing with curing complete as directed.
Cement plaster skirting with cement mortar (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soiling including 15mm thick cement plastering in prop 1:3: finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thouroughly all dirt and remains of loops powered materials.
(D) Construction of Canteen: Earth work in excavation for foundation trenches of walls, retaining walls, footings of colums, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work. breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary. (A) Up to a depth of 2.0 m below the existing Ground Level (a) In Ordinary Soil.
Providing brick work soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand coarse aggregate by volume. (using mixture machine)
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall & boundary wall etc.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) C) ISI approved Mild steel reinforcement bar (m.S. Bar)
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 1. Colums, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 2. Sides and soffits of beams, beam haunching, cantilever, girders, bressumers lintelsand horizontal ties. (a) For depth not exceeding 1.0M.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3. Flat Surface such as soffts of suspended floors roofs landings cantelever slabs chajjas balconies and the like. (a) Floors etc. upto 200mm in thickness
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using Mixture Machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. a) M-15 or Prop 1:2:4
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using Mixture Machine (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. (a) M-15 or Prop.1:2:4
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (c) In prop 1:5
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:5 (1 cement:5 sand)
10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:5
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (c) In cement mortar 1:5
Providing fitting and fixing M.S grill of required pattern for windows/ clerestory windows/opening with M.S flats at required spacing in frame all ground, squre or round M.S bars with round headed bolts and nuts or screws. 1. Plain Grill (c) Fixed to Brickwork/PCC/RCC
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (Predominantly non plastic) by truck carriage including loading andf unloading.
Plain cement concrete floor base in prop 1:3:6 laid in altermate bays as specified with coarse agg. Of size 13mm to 32mm including dewatering if necessary and curing etc. complete. C) 100mm thick.
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
Providing polished VITRIFIED wall tiles of approved quality of specified size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) white cement slurry mixed with approved pigment to match shade of tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the department) i) Of size 300mm x 450mm and above
Cement plaster skirting with cement mortar (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
Providing fitting and fixing in position false ceiling of 6mm thick Bison panel (cement bonded particle board) on timber frame of 1st class local wood (Hollock/Bonsum/Sundi) of 50mm x 50mm spactedat not more than 1.20m apart, fixed to the wall at the end with necessary nails, wood screws, hooks, bolts, etc. including painting (one coat primer and two coats of painting) as necessary complete as directed by the Department for all levels. (a) One sides commercial
CEMENT PAINT & PRIMER (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thouroughly all dirt and remains of loops powered materials.
Applying priming coat over new steel and other metal surface over 100mm in width or girth after preparing the surface by throughly cleaning otl grease. Dirt and other foreign matter sand scoured with wire brushes fine steels wood scrapers and sand paper. a) With ready mixed red-lead/red oxide primer
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolic) to give an even shade including cleaning the surface of all dirt dust and other foreign matter. (i) Surface over 100mm in width or girth (a) General purpose (Asian paint/Berger paint/ ICI paint/J & N paint/Nerolac).
(E) Construction of RCC Drain Type-A: Earthwork in excavation for Structures as per drawing and technical specification clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary Soil (i) Upto 3m depth
Laying brick soling layer on prepared sub-grade with brick on end edging according to lines, graded and cross section shown on the drawing filling joints with sand and earth spreading 25mm thick layer of earth soling watering and rolling the same with three road roller 80-100 Kn as per Technical Specification clause 412
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. i) PCC Grade M 10 Nominal mix 1:3:6
Plain/reinforced cement concrete in substructure complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807, 1202 & 1203 A. With crushed stone. iii) RCC Grade M 20 i) For height upto 5m
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From primary Producer: TATA/SAIl/Esser Steel/Jindal Steel/Shyam Steel/RINL) in sub structure complete as per drawing and technical specifications Clauses 1002, 1005, 1010 & 1202.
Plastering with cement mortar (1:4), 15 mm thick on brick work in substructure as per technical specification Clauses 613.4 & 1204
Providing Antiskid Tailes of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tike (Choksey/Sika/Pedelite/Rouf) white cement complete at all level as specified and directed. VITRIFIED i) Normal range (Sizes 300mm x 300mm and above) Somany made-Durastone (Unpolished heavy duty Vitrified Tiles) b) Deluxe
(F) Construction of RCC Drain Type-B: Earth work in excavation for structures as per drawings and technical specification Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matterial and disposal up to a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary Soil (i) Up to 3m Depth
Providing brick soling in earthen shoulder with stone/best quality jhama brick, sand packed and laid to true line and level and in panel after preparing the sub grade including earthwork in excavation as directed including all labour and materials and if necessary dewatering complete. (a) Brick on Flat Soling.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed stone. ii) PCC Grade M 15 Nominal mix 1:2.5:5
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
(G) Roof Treatment (Exsting Main Building): ROOF TREATMENT Grading roof for water proofing treatment with (b) cement mortar (i) 1:3 (1 Cement: 3 coarse sand)
(H) Construction of Garrage, 4 Nos.: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing soiling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement: 3 sand : 6 coarse aggregate by volume.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall & boundary wall etc.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) c) ISI approved M.S. Rod.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Colums, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2. Sides and soffits of beams,beam haunchings, cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixture Machine (a) Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. a) M15 grade concrete or Prop 1:2:4
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. a) M15 grade concrete or Prop 1:2:4
Brick work in cement morter with 1st class brick including racking out joints and dewarting if necessary and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:5 (1 cement:5 sand)
10mm thick cement plaster in single coat on fair side of brick/concrete wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (c) In cement mortar 1:5
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side c) In cement mortar 1:5
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately). (c) 0.55mm thick
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With river sand or silt (predominently non plastic) by truck carriage including loading and unloading.
Plain cement concrete floors base in prop 1:3:6 laid in alternate bays as specified with coarse agg.of size 13mm to 32mm including dewatering if necessary, and curing etc complete. (b) 50mm thick
CEMENT PAINT & PRIMER (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thouroughly all dirt and remains of loops powered materials.
(I) Renovation of Boundary Wall (Length=580.00m) Demolishing the plastering frame walls/R.C.C and P.C.C members without causing any change to the walls/member upto any height including disposal of debris as directed for all levels.
10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:5
Applying one self-priming coat of acrylic emulsion coating of Unicem ''Rakshak'' brand by thining 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered as specified and directed by the department.
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem ''Rakshak'' brand required shade by thining 1ltr of paint with 750ml of water to give an even shade throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine stees, wood scrapers and sand paper. (a) With ready mixed red-lead/red oxide primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surface over 100mm in width or girth. a) General purpose (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac).
(J) Construction of Gr-IV Qtr 3 Nos.: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing brick work soiling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (1:3:6)
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (upto 1st floor level)
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (upto 1st floor level) (c) ISI approved M.S Bar
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1 Column, pillar, post & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plan vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas balconies and the like (a) Floors etc. upto 200mm in thickness.
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (a) In Sub-Structure up to plinth level M 15
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (b) In Super-Structure from plinth level up to 1st floor level M 15
Brick work in cement morter with 1st class brick including racking out joints and dewarting if necessary and curing complete as directed in sub-structure up to plinth level. prop 1:4
112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (b) In cement mortar in proporation 1:5
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed. (Door hinges to be paid as per relevant item of the schedule of rates).
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. (b) Non decorative type and block board core. (ii) 35 mm thick
Providing, fitting and fixing steel windows/ ventilators (openable) of standard rolled steel sections as per relevant I.S. Code-1038 joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stays of 300mm long etc. complete as per drawing coat of red-lead paint.
Providing and fixing clear sheet glass beded in putty and fixed with/wiithout wooden bidings including necessary cutting of glass to required sizes (payment for wooden beads shall be made separately). (A) Area of glass panes not exceeding 0.15sqm. © 3.00mm thick
Providing, fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made fromm extruded PVC stiles and rails made from rigid PVC multicavity hollow chamber section of size 90mmx37mm (Toletance+ 1mm). The corners of the stiles and rails shall be metred out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular galvanised two nos of size 200mmx100mm and 100mmx100mm at each corner by self tapping steel screws. PVC multicavity hollow section of size 105mmx37mm shall be fixed in the middle by aluminium cleat and steel screws as lock rail. The section frame shall then be filled with PVC panels of approved colour of size 100mmx20mm. Then two numbers of bright steel rods of 6mm diameter shall be inserted horizontally through stiles and panels with two numbers of checknuts and washers all complete as specified and directed at all levels. (Door fixtures and fittings to be measured and paid separately).
10mm thick cement plaster in single coat on fair side of brick/concrete wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:6
15mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (c) In cement mortar 1:6
Providing fitting and fixing M.S grill of required pattern for windows/ clerestory windows/opening with M.S flats at required spacing in frame all ground, squre or round M.S bars with round headed bolts and nuts or screws. I. Plain Grill (a)
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black-tubes conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
Providing galvd iron ridging of TATA SHAKTEE/SAIL. Including supplying and fixing necessary galvd screws/washers etc.complete as directed. ( c ) 0.55mm thick (i) 150mm lapping
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately) (c) 0.55mm thick
Earth/Sand filling in plinth in layer not more than 150mm thick including necessary, carriage, watering, raming etc.complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. (C) With river sand or Silt (predominently non plastic) by truck carriage including loading and unloading.
65mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 (1 cement :3 coarse agg. Of size 25mm down) and 15mm thick wearing layer in cement concrete 1:1:2 (1cement : coarse sand : 2 coarse agg. Of size 10mm down laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg Per sqm of floor area) including curing etc.complete as directed.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
Providing fitting and fixing in position false ceiling of 6mm thick Bison panel (cement bonded particle board) on timber frame of 1st class local wood (Hollock/Bonsum/Sundi) of 50mm x 50mm spactedat not more than 1.20m apart, fixed to the wall at the end with necessary nails, wood screws, hooks, bolts, etc. including painting (one coat primer and two coats of painting) as necessary complete as directed by the Department for all levels. (a) Both sides commercial
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soiling including 15mm thick cement plastering in prop 1:3: finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
(a) Clour washing with lime on wall surface (two coats) over and including a priming coat of white washing to givean even shade after thouroughly brooming the surface to remove all dirt, dust mortar drops and other foreign matter.
Applying priming coat over new steel and other metal surface over 100mm in width or girth after preparing the surface by throughly cleaning otl grease. Dirt and other foreign matter sand scoured with wire brushes fine steels wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolic) to give an even shade including cleaning the surface of all dirt dust and other foreign matter. (i) Surface over 100mm in width or girth (a) General purpose (Asian paint/Berger paint/ ICI paint/J & N paint/Nerolac).
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.(anodised to bright nature matt & satin finished). (a) Sliding door bolts. (ii) 250mm x 16mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.(anodised to bright nature matt & satin finished). (b) Tower bolts. (ii) 250mm x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.(anodised to bright nature matt & satin finished). (b) Tower bolts. (iv) 150mm x 10mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.(anodised to bright nature matt & satin finished). (c) Door handles. (ii) 150mm
For Sanitary Installation: Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soiling and 75mm 1:3:6 P.C.C. Baffle wall intel and outlet etc are providing at suitable points complete as directed. 50 Users
Providing fitting and fixing vitreous water clost squatting pan (indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls floors where required. (Flushing Cistern to be paid separately) 1.1.1. Indian type W.C Orissa pattern of size 580 x 440 mm a) White i) Parryware make
Supplying fitting and fixing PVC flushing cisterm with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe union clams etc.complete as directed and specified (pipes will be measured separately) i) Parryware make a) White (i) Economy single flush (Cat No.C8090/C8055)
Providing victreous China wash basin with CI/MS brackets, C.P brass chain with plug.PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) A) Parryware make a) White (ix) Cardiff 580 x 450 (Cat. No.C0480/81, C0375) (white/coloured)
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets C.P. Brass chain with rubber plug PVC waste pipe etc. complete including painting the fittings cutting & making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately) (A) Parryware Make (vi) Single Bowl (160 x 180) Flat Edge-Glossy (Cat. No.C8538)
Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (b) Size 600mm x 450mm
Providing fitting and fixing recessed soap tray/soap dish complete as directed as directed and specified. (A) Parryware Make (iii) Corner Soap tray (cat. No.C9949)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No.ACN-1101N)
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including jointing, fitting and fixing wall clams etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fitting and fixing 87.5 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing 45 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing PVC single Y of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Providing and fitting and fixing 450mm dia. 90mm thick C.I Man hole cover and frame of 58 kg. weight complete as directed and specifed.
Construction of filter bed soak pit including earth work in exacavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C.plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Supplying fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required and complete at all levels including below G.L as directed and specified. A) In exposed surfaces or in trenches. (ii) 100mm dia.
For Water Supply Works: Labour for boring hole for inserting tube well pipes through different soil/rockk media including hire charges of drill pipes,scaffolding,tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. i) Bore hole of 75mm diameter
Supplying, fitting and fixing plain/bevel ended for casing, conforming to relevent IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign material in the annual space between the borehole and assembly pipes complete as directed by the Department. (i) G.I pipe a) TATA/SAIL (Medium) socket should be welded to the pipes. i) 50mm diameter
Supplying fitting and fixing check valve (non return valve) including thread to pipes. iii) 40mm diameter
Labour for execting and placing PCVC tank over the stagging of 5.00M upto 8.00M complete as directed. A) 2000 litre capacity.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged structure. d) 40 mm dia (Medium) (I) Using Tata make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged structure. d) 25 mm dia (Medium) (I) Using Tata make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged structure. f) 15 mm dia (Medium) (I) Using Tata make
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (v) 40mm dia
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (iii) 25mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (I) Essco make (Delux/Sumthing spl./Tropical) (a) Bib cock short body
Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately) (II) Lauret make (Telephonic hand shower with 1.5 m PVC pipe with hook)
(K) Construction of Gr-III Qtr 2 Nos.: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing soiling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement: 3 sand: 6 coarse aggregate by volumne.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (upto 1st floor level) (b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg, drain works, retaining wall & boundary wall etc.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (upto 1st floor level) (c) ISI approved MIld Steel reinforcement bar (M.S. Bar)
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1 Column, pillar, post & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plan vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas balconies and the like (a) Floors etc. upto 200mm in thickness.
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1cement : 2 coars sand : 4 coars aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixture machine. (a) Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level a) M15 grade concrete or prop 1:2:4
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1cement : 2 coars sand : 4 coars aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixture machine. (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. a) M15 grade concrete or prop 1:2:4
Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:2.4 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
Brick work in cement morter with 1st class brick including racking out joints and and curing complete as directed. (I) In sub-structure up to plinth level including dewatering if necessary. (b) In proporation 1:4
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) a) 112mm thick brick wall (b) In cement mortar in proporation 1:5 (1 cement: 5 sand)
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed. (Door hinges to be paid as per relevant item of the schedule of rates).
10mm thick cement plaster in single coat on fair side of brick/concrete wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:5
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (c) In cement mortar 1:5
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. (b) Non decorative type and block board core. (ii) 35 mm thick
Providing, fitting and fixing steel windows/ ventilators (openable) of standard rolled steel sections as per relevant I.S. Code-1038 joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stays of 300mm long etc. complete as per drawing including applying a priming coat of red-lead paint.
Providing and fixing clear sheet glass beded in putty and fixed with/wiithout wooden beadings including necessary cutting of glass to required sizes (payment for wooden beads shall be made separately). (I) Area of glass panes not exceeding 0.15sqm. © 3.00mm thick
Providing fitting and fixing M.S grill of required pattern for windows/ clerestory windows/openingwith M.S flats at required spacing in frame all ground, squre or round M.S bars with round headed bolts and nuts or screws. 1. Plain Grill (b) Fixed to steel frames
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black tube conforming to relevent I.S. code, as per approved and drawings including providing M.S. cleats, plates bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paintscomplete including fitting necessary clear etc.for fixing joists as per design and drawings as directed. b) Using other ISI marked approved circular hollow section.
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick and purlin etc.to be measured and paid separately). (c) 0.55mm thick
Providing galvd iron ridging of TATA SHAKTEE/SAIL. Including supplying and fixing necessary galvd screws/washers etc.complete as directed. ( c ) 0.55mm thick (i) 150mm lapping
Earth/Sand filling in plinth in layer not more than 150mm thick including necessary, carriage, watering, raming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. (C) With river sand or silt (predominently non plastic) by truck carriage including loading and unloading.
65mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 (1cement :3 coarse agg. Of size 25mm down) and 15mm thick wearing layer in cement concrete 1:1:2 (1cement : coarse sand : 2 coarse agg. Of size 10mm down laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg Per sqm of floor area) including curing etc.complete as directed.
Providing fitting and fixing in position false ceiling of 6mm thick Bison panel (cement bonded particle board) on timber frame of 1st class local wood (Hollock/Bonsum/Sundi) of 50mm x 50mm spactedat not more than 1.20m apart, fixed to the wall at the end with necessary nails, wood screws, hooks, bolts, etc. including painting (one coat primer and two coats of painting) as necessary complete as directed by the Department for all levels. (a) Both sides commercial
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
DISTEMPERING (f) Distempering witn dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after thoroughly brushing the surface free from morter droppimgs and other foreign matter and including preparing surface even and sand papered smooth.
CEMENT PAINT & PRIMER (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thouroughly all dirt and remains of loops powered materials.
Applying priming coat over new steel and other metal surface over 100mm in width or girth after and preparing the surface by throughly cleaning oil grease, dirt and other foreign matter and scoured with wire brushes fine stells, wood scrapers and sand paper. (b) With ready mixed red-lead oxide primer
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolic) to give an even shade including cleaning the surface of all dirt dust and other foreign matter. (i) Surface over 100mm in width or girth (a) General purpose (Asian paint/Berger paint/ ICI paint/J & N paint/Nerolac).
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). (a) Sliding door bolts (ii) 250mm x 16mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). (b) Tower bolts (ii) 250mm x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). (b) Tower bolts (iv) 150mm x 10mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). (c) Door handles (ii) 150mm
For Sanitary Installation: Providing fitting and fixing vitreous water clost squatting pan (indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls floors where required. (Flushing Cistern to be paid separately) 1.1.1. Indian type W.C Orissa pattern of size 580 x 440 mm a) White i) Parryware make
Supplying fitting and fixing PVC flushing cisterm with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe union clams etc.complete as directed and specified (pipes will be measured separately) i) Parryware make a) White (i) Economy single flush (Cat No.C8090/C8055)
Providing victreous China wash basin with CI/MS brackets, C.P brass chain with plug.PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) A) Parryware make a) White (ix) Cardiff 580 x 450 (Cat. No.C0480/81, C0375) (white/coloured)
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets C.P. Brass chain with rubber plug PVC waste pipe etc. complete including painting the fittings cutting & making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately) (A) Parryware Make (vi) Single Bowl (160 x 180) Flat Edge-Glossy (Cat. No.C8538)
Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (b) Size 600mm x 450mm
Providing fitting and fixing recessed soap tray/soap dish complete as directed as directed and specified. (A) Parryware Make (iii) Corner Soap tray (cat. No.C9949)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No.ACN-1101N)
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including jointing, fitting and fixing wall clams etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fitting and fixing 87.5 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing 45 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing PVC single Y of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Providing and fitting and fixing 450mm dia. 90mm thick C.I Man hole cover and frame of 58 kg. weight complete as directed and specifed.
Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soiling and 75mm 1:3:6 P.C.C. Baffle wall intel and outlet etc are providing at suitable points complete as directed. (viii) 50 Users
Construction of filter bed soak pit including earth work in exacavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C.plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Supplying fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required and complete at all levels including below G.L as directed and specified.
For Water Supply Works: Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged structure. d) 40 mm dia (Medium) (I) Using Tata make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged structure. d) 25 mm dia (Medium) (I) Using Tata make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged structure. f) 15 mm dia (Medium) (I) Using Tata make
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (v) 40mm dia
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (iii) 25mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (I) Essco make (Delux/Sumthing spl./Tropical) (a) Bib cock short body
Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately) (II) Lauret make (Telephonic hand shower with 1.5 m PVC pipe with hook)
(L) Construction of RCC Gate: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing soiling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement: 3 sand : 6 coarse aggregate by volume.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (No extra mesurement for lap, hook, chair anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) from Primary Producer: TATA/SAIl/Esser Steel/Jindal Steel/Shyam Steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Colums, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2. Sides and soffits of beams,beam haunchings, cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixture Machine (A) Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. (b) M-20 grade concrete or prop 1:1.5:3
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixture Machine (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. (b) M-20 grade concrete or prop 1:1.5:3
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:5 (1 cement:5 sand)
10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:5
HERITAGE FINISHING Supplying and laying of permanent wall finish for interior and exterior walls with surface coating of Heritage surface texture of bakelite hylam limited for all types of buildings at all levels as specified and directed by the department. (f) Flakes with Top coat (Code: HFRT)
(M) Earth Filling: Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees if any monopoly duty etc. (profile meassurement to be taken and 12.5% deduction for shrinkage to be made from total quantuty) etc. complete as directed and specified. (b) Other than Guwahati city
(N) Plantation: TREE PLANTING Supplying and placing of ornamental trees (1-0 height sapling) including pit making ( 60cm x 60cm x 60cm) filling the pit with appropriate soil media manure and fertilizers as per specification and necessary maintenance for a period of one year from SHADE TREE A) Neem/Mahaneem/Beef wood/Bakul/Acacia/Siris/Devils tree/Kadam/Palash/Pink Cassia/Peedal/Silver oak/Simalu/Ajar.
TREE PLANTING Supplying and placing of ornamental trees (1-0 height sapling) including pit making ( 60cm x 60cm x 60cm) filling the pit with appropriate soil media manure and fertilizers as per specification and necessary maintenance for a period of one year from SHADE TREE B) Kanchan/Nahar/Arjun
TREE PLANTING Supplying and placing of ornamental trees (1-0 height sapling) including pit making ( 60cm x 60cm x 60cm) filling the pit with appropriate soil media manure and fertilizers as per specification and necessary maintenance for a period of one year from SHADE TREE C) Sonaru
TREE PLANTING Supplying and placing of ornamental trees (1-0 height sapling) including pit making ( 60cm x 60cm x 60cm) filling the pit with appropriate soil media manure and fertilizers as per specification and necessary maintenance for a period of one year from SHADE TREE Flowering Tree (A) Gulmohar/Ashok
TREE PLANTING Supplying and placing of ornamental trees (1-0 height sapling) including pit making ( 60cm x 60cm x 60cm) filling the pit with appropriate soil media manure and fertilizers as per specification and necessary maintenance for a period of one year from SHADE TREE Flowering Tree (B) Kanchan
Half brick circular tree gaurd internal diametre 1.25m and height 1.2m above ground and 0.02m below ground bottom two coarses laid dry and top three coarses in cement mortar 1:6 and the intermediate coarses being in dry honey comb masonry as per design complete.
(O) Sanitary Works at Main Building: Clearance of service septic tank and removing the night soil and bebris etc. manually from the tank/chamber to a distant place preferably during holidays or at night by bailing out the deposited night soil, buring the same in near by trenches/pits which has been dug earlier and covering the same. the service septic tank is cleaned with clear water and completed as directed by the Department. (a) For 200 users
Renewing vitreous water closet squatting pan (Indian type W.C. Orrissa pattern) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. (Flushing Cistern to be paid separately) indian type W.C. orrisa pattern of size 580 x 450mm b) Coloured (ii) Hindware make
Renewing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers, CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make b) Coloured (i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover)
Renewing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe union clamps etc. complete as directed and specified ( pipes will be measured separately) I) parryware make b) Coloured (ii) Deluxe Single Flush (Cat No.C8091/C8057)
URINAL Renewing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (B) Parryware Make (a) White (i) New Magnum (Cat. No.C0575)
WASH BASIN Renewing wash basin with C.P brass chain with plug PVC waste pipe including painting of fittings and brackets, cutting and making good the walls, wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with Pedestal) (A) Parryware Make (a) White (i) Duke 660 x 495 (cat. No.C8416/27) (White/Coloured)
Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (b) Size 600mm x 450mm
Providing fitting and fixing recessed soap tray/soap dish complete as directed and specified. (A) Parryware Make (iii) Corner Soap tray (Cat. No.C9949)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No.ACN-1101N)
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including jointing, fitting and fixing wall clams etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fitting and fixing 87.5 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing 45 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing PVC single Y of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Providing and fitting and fixing 450mm dia. 90mm thick C.I Man hole cover and frame of 58 kg. weight complete as directed and specifed.
Construction of filter bed soak pit including earth work in exacavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C.plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table. (2x1.50x1.50x2.00)
Supplying fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required and complete at all levels including below G.L as directed and specified. A) In exposed surfaces or in trenches. (ii) 100mm dia.
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
(P) Water Supply Works Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (I) 2000 Lt capacity (a) Sintex make
Labour for erecting and placing PCVC tank over the stagging of 5.00M upto 8.00M complete as directed. A) 2000 litre capacity.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged structure. b) 40 mm dia (Medium) (I) Using Tata make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged structure. d) 25 mm dia (Medium) (I) Using Tata make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged structure. f) 15 mm dia (Medium) (I) Using Tata make
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (v) 40mm dia
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (iii) 25mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (I) Essco make (Delux/Sumthing spl./Tropical) (a) Bib cock short body
Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately) (II) Lauret make (Telephonic hand shower with 1.5 m PVC pipe with hook)
(Q) Cost of Sign Board: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). a) In prop. 1 cement : 3 sand : 6 coarse aggregate by volume (using mixture machine)
Structural steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint including drilling holes, supplying fitting and fixing with bolts and nuts or welding if necessary as directed. © In M.S angles, chanels, Tees etc.
Sri Hiramba Narzary
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .