Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | ist₹5.9 CrAccepted-Finance | ₹5.9 Cr | ist | Accepted-Finance L1 |
| 2 | Not Admitted-Fee/PreQual/Technical CUTTACK | - | - | Not Admitted-Fee/PreQual/Technical Others- has an Average Annual Financial Turnover of less than 300Cr, has not uploaded the Undertaking as required under Annexure E, and the firm's experience is insufficient. Hence, as per clauses (6 & 7) in the instructions to bidders of SBD, Hence NR |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others- Bidder has assigned the EMD to the Ex.Engineer, R&B Mech Div, SK instead of the SE,PW(R&B),Circle, Pulwama/Shopian,and has not provided the Undertaking on the OEM letter header as required under Annexure E. Hence,as per clause (2),assessed as NR |
| 4 | Not Admitted-Fee/PreQual/Technical A 15 RAJ PARK SULATANPURI ROAD SULTANPURI NEAR CITYMEN PUBLIC SCHOOL NORTH WEST DELHI DELHI 110086 | NORTH WEST DELHI | DELHI | 110086 | - | - | Not Admitted-Fee/PreQual/Technical Others-The Bidder has not uploaded the Tender Document, Fee, EMD, Average Annual Financial Turnover Certificate, and Various Undertakings. Hence, as per clause (1, 2 &7) in the instructions to bidders of SBD bid of bidder has been assessed as Non Responsive |
Tender Value
₹6.3 Cr
EMD Value
₹12.6 L
Closing Date
12 Feb 2026, 2:00 pmClosed
Executive Engineer RandB Mech Div South
Office of Executive Engineer RandB Mech Div South
Design Manufacturing Supply Installation Testing and Commissioning of 28 No (G plus 5) 08 passengers MRL lifts at Transit Accommodation at Lethpora I Pulwama.
2026_PWDJK_300350_1
e-NIT No 37 of RandB/MDSK/2025-26 Dated 10 / 01 /2026
Open Tender
Machineries/ Mechanical Engg Items
Percentage
120 days
Lethpora Pulwama
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,500
Executive Engineer RandB Mech Div South
₹12.6 L
Office of Executive Engineer RandB Mech Div South
11 Apr 2026
10 Jan 2026
13 Feb 2026
10 Jan 2026
12 Feb 2026
10 Jan 2026
17 Jan 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | A) Supply,Installation Testing & Commissioning of 08 Passenger (G+5) MRL lift at Transit accommodation Lethpora Pulwama Phase I (excluding all the civil works). The lift shall be suitable for 08 passengers, of standard design having speed not less than 1m/s to 1.5m/s serving from Ground, 1st, 2nd, 3rd, 4th & 5th floor i.e. 06 stops and 06 landings. The elevator shall be of state of art technology, energy efficient drive and all its components/ accessories shall conform to relevant IS standards.
• (The Defect Liability Period (DLP) of the equipment shall be 02 years.• Machine – Gearless machine located in the shaft on the top of guiderails
• Power Supply – 400/415 V (3 Phase AC)• Control – Simple Collective Selective Control (VF regenerative drive)
• Available Hoist way dimensions -
Width- 2133 mm, Depth- 2006 mm, Pit depth -1219 mm, Overhead - 5029mm• Landing door – Centre door opening in stainless steel hairline.
• Door opening :Ground, Ist, 2nd, 3rd, 4th & 5th floor on same side• Car design - Stainless steel in hairline finish.
• Handrail - Round handrail in stainless steel finish provided on rear wall of car.• Alarm button in car operating panel with battery back-up.
• Automatic operation for car fan.• Anti-nuisance (empty car)• Anti-nuisance (car call cancellation at direction reversal)
• Blower fan in car for ventilation• Braille on push buttons• Door open and door close buttons in car operating panel.
• Door closing retries• Door nudging• Emergency light
• Full load by-pass• Infra–red screen for car door
• Intercom Provision With Instrument• Motor overheat protection.
• Overload function with audio-visuals indication in car operating panel.• Phase failure and phase reversal protection.
• Automatic rescue device in case of power failure.
• Attendant control.Car arrival chime on car top/voice synthesizer.
• LCD dot matrix scrolling display in car operating panel.
• LCD matrix scrolling display in landing operating panel on all floors.
• Fireman control.
• Fireman emergency return.
The rates are inclusive of all minor adjustments that may be required in hoistway/pit for completion of the job
B) Suitable no. of earth stations/earthings as per OEM recommendations.
C) Providing & Laying integral Cement based water proofing (Injected type) treatment including preperation of surface and then applying and grouting a slurry coat of neat cement using 2.75kg/sqm of cement admixed with proprietary water proofing compound confirming to IS: 2645. After proper curing apply a second coat of cement slurry admixed with proprietry water proofing compound. The job includes finishing the surface with 20mm thick jointless cement morter of mix 1:4 | 28 | C.Job | 0.61 | ₹17.19 |
| 2 | Electric Works
Supply, installation, testing & commissioning of 3 Phase- 60 kVA servo-stabilizer including oil and all allied electrical acessories with earthing.
The stabiliser should have following specifications:
a) Capacity: 60 kVA, 3-phase unbalanced type
b) Input: (100-265) V AC P-N; (180 - 460) V AC P-P
c) Output: 415 V ± 1% - phase to phase
d) Supply: 3 phase, 4 wires, 50Hz
e) Operation: Automatic
f) Duty cycle: Continuous
g) Transformer windings: Copper wound on CRGO laminations as per IS specifications
h) Cooling: Oil cooled
i) Efficiency: Better than 98% at full load
j) Overload capacity: 15% for continuous 4 hours
k) Waveform distortions: Nil
l) High speed voltage correction: up to 8V to 20V per second
m) Protections: Under voltage, Over voltage and Overload with time delay
n) Other features: LED indicators, Digital AC ammeter, AC voltmeter, Frequency meters, Phase Sequence meters, Single phase preventer, Stabilizer by-pass arrangement. | 7 | Job | 0.29 | ₹2.03 |
| 3 | Supply, Installation and Testing & Commissioning of Control Panel enclosed in suitable sized CRC/weather proof Enclosure(SWG16, powder coated) with IP-Rating to prevent ingress of water and comprising of Bus bar MCCBs, single phase preventers, changeover switches, for lifts with following specifications with Earthing.
Incomer:
1. MCCB 200A 4P 01 No (36-50 kA)
2. Front Operated Manual Change Over (200A ) 01 No. (4P)
3. MCCB 160A TPN (36kA breaking capacity) of reputed make preferably L&T/ABB/Schneider.
4. 200A Aluminum 4 Pole Bus Bar –01 set
5. Digital Voltmeter with Selector Switch
6. Digital Ammeter with Selector Switch & CT’s
7. Phase Indicator Set
Outgoing feeders:
a) 40A Four Pole MCBs C type (10 kA breaking Capacity)- 04 No's of reputed make preferably L&T/ABB/Schneider. The job is inclusive of the cost on account of concrete foundation/footing for resting of the Control Panel. | 7 | Job | 0.29 | ₹2.03 |
| 4 | Providing / Fitting/Testing/Commissioning of 3.5 core, 95 sqmm XLPE, PVC sheathed, armoured Al cable from Distribution Transformer to Servo Stabilizer with other accessories of suitable rating to be laid underground (in HDPE pipes) as per requirement (to be paid as per actual). | 610 | Rm | - | - |
| 5 | Providing / Fitting/Testing/Commissioning of 3.5 core, 50 sqmm, XLPE, PVC sheathed, Al cable from Servo Stabilizer to Control Panel with other accessories of suitable rating to be laid underground (in HDPE pipes) as per requirement (to be paid as per actual). | 380 | Rm | - | - |
| 6 | Providing / Fitting/Testing/Commissioning of 3.5 core, 25 sqmm XLPE, PVC Sheathed, Al cable from Control Panel to individual lifts with other accessories of suitable rating to be laid underground (in HDPE pipes) or in conduits of suitable size as per requirement (to be paid as per actual). | 1,470 | Rm | - | - |
| 7 | Miscellaneous Jobs in the Lift Shaft (to be paid as per actual)
Providing and fixing of the suitable lifting/hoisting beam(ISMB-250) at the overhead of lift shaft. The job includes providing and fixing of base plates with the shaft walls by means of anchor fasteners and welding of the beam with the base plates after proper alignment. (to be paid as per actual). Job includes applying a priming coat of approved steel primer. | 4,000 | Kg | - | - |
| 8 | Supply,installation,and wiring of IP65-rated LED bulkhead lights in the lift shaft, including secure mounting, conduit wiring, connection, testing and commissioning as per approved specifications.(to be paid as per actual) | 196 | No | - | - |
| 9 | Providing and fixing of ladder fabricated out of structural steel of requisite sections at terrace for maintenance,inspection, emergency access to lift shaft etc. (to be paid as per actual). Job includes applying a priming coat of approved steel primer. | 2,800 | Kg | - | - |
| 10 | Brick work with common burnt clay F.P.S (non-modular) bricks of class designation 75 in super structure in cement mortar 1:6 (cement :6 Fine sand) including carriage of all materials involved with loading unloading and stacking complete. (to be paid as per actual) | 130 | Cum | - | - |
stage.html
html • 0.04 MB
technical_974317.pdf
techsummary_974317.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 1.62 MB
BOQ_974317.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .