| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.2 Cr+₹15.9 L (14.6%)Rejected-AOC | ₹1.2 Cr+₹15.9 L (14.6%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.4 Cr+₹31.4 L (28.9%)Rejected-AOC OPP SHRI NAVNIKETAN H S SCHOOL CHHOLA KANCHI BHOPAL M P | BHOPAL | MADHYA PRADESH | 462010 | ₹1.4 Cr+₹31.4 L (28.9%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹1.5 Cr+₹37.6 L (34.6%)Rejected-AOC | ₹1.5 Cr+₹37.6 L (34.6%) | L4 | Rejected-AOC Rejected |
Tender Value
₹96.9 L
EMD Value
₹1.7 L
Closing Date
27 Dec 2022, 6:00 pmClosed
CWE JHANSI
HQ CWE JHANSI
PROVN OF MORTUARY AND AUTOPSY ROOM, TECHNICAL TRAINING DEPARTMENT FOR MH JHANSI AND CERTAIN B/R AND E/M WORKS UNDER GE JHANSI
2022_MES_560994_1
CWE/JHA/J/TOKEN/50 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
JHANSI
As per tender documents
9 documents required · 9 mandatory
₹1,000
GE JHANSI
₹1.7 L
Yes
9 Feb 2023
2 Nov 2022
3 Jan 2023
2 Nov 2022
27 Dec 2022
14 Dec 2022
Amount
Demolition of Brickwork masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars and precast concrete articles complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame) complete all as specified and directed.
Taking down Chowkats or frames Not exceeding 1.5 Sqm each (Without taking off shutters from the frame) complete all as specified and directed.
Demolition of cement concrete un-reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Taking down steel tubing and connections including cleaning and re-fixing or removal to store 15mmm bore pipe complete all as specified and directed.
Taking down steel tubing and connections including cleaning and re-fixing or removal to store 20mmm bore pipe complete all as specified and directed.
Dismantling water tanks exc 500 but n.exc 1000 litres capacity complete all as specified and directed.
Taking down eaves gutter and rain water pipes including all fittings any size and pattern complete all as specified and directed.
Demolition existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime concrete etc, cleaning of all foreign material i.e. fungus mass dust etc, roughing surface of corner on roof by wire brush, complete all as specified and directed.
Demolition of RCC not exceeding 15cm thickness in roofs, floors (other than ground floors), beams staircases, landing, chajjas, Cover slab and similar suspended work, complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense of soil complete all as specified and directed.
Rough excavation not exceeding 1.5 m depth and getting out hard/dence soil complete all as specified and directed.
Excavation over area not exceeding 1.5 m depth and getting out hard/dence soil complete all as specified and directed.
Removing excavated material exc. 250m upto 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Forming embankments including raising or lowering earth to spreading, levelling, watering and well ramming with power roller 8 to 12 tonne in layers not exceeding 30cm and finishing to required size ,shape etc n.exc 1.5mtr height from base etc complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard & dense soil complete all as specified and directed.
Removing excavated material exc. 50m upto 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations fillings & mass concrete complete all as specified and directed.
M&L Cement concrete 1:3:6, type C-2 (Nominal mix) using 40 mm graded crushed stone aggregates in foundation filling and mass complete all as specified and directed.
M&L for 3D printed concrete wall panel comprising of 3 layer of overall thickness wall 300mm complete all as specified and directed.
M&L providing M25 Design mix (using 20 mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L providing M25 Design mix (using 20 mm graded aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L providing M25 Design mix (using 20 mm graeded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M/L providing M25 Design mix (using 20 mm graded aggregate as in Chajjas,shelf etc complete all as specified and directed.
M&L providing M25 Design mix (using 20 mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Cement concrete Type B1 1:2:4 (20 mm graded aggregate) in bed block for holdfast, band, stops, coping, benching and the like including weathering, slightly rounded or chamfered angles , padding/levelling course, roof kerb as directed including form work and finishing all exposed surfaces etc complete all as specified and directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed/consolidated including watering complete all as specified and directed.
M&L for sand filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggreagate as in sub base of flooring complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4 Type B1 as in damp proof course with WPC using 12.5 mm graded stone aggreagate complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for brick work with fly ash (old size) bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Brickwork with fly ash (old size) bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars (FE 500D), 6 to 8 mm dia and over in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed.
M&L 15mm thick rendering on fair faces of brick or concrete surfaces in CM 1:4 finished even and fair complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick surfaces in cement mortar (1:4) finished even and fair including mixing of integral water proofing admixture in the proportion as mentioned in manufacturer's instructions complete all as specified and directed. (Integral water proofing mixture shall be measured & paid for separately).
M&L 15mm thick rendering other than fair faces of brick or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L 5mm thick rendering in CM 1:3 on ceiling of concrete surface finished even and smooth etc. complete all as specified and directed
M&L 10mm thick rendering in CM 1:3 on fair faces of concrete surface finished even and fair with WPC 0.20 lts per bag of cement used on roof , chhjja complete all as specified and directed.
Liquid water proofing compound complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, of size 600x600x7 to 8 mm thick (square/rectangular) , in floors etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed by the Engineer -in-charge.
All as per item No 52 but as in skirting and set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM (1:6) complete all as specified and directed.
M&L for non skid ceramic color tiles of size300x300x7 to 8 mm thick ( square / rectangular) as in flooring etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed/ bedding layer in CM (1:6) complete all as specified and directed.
M&L for glazed ceramic coloured tilesof size 300x 450x 7 to 8 mm thick on vertical surface such as in dado over 10 mm thick rendering in CM (1:4) complete all as specified and directed.
S&F vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including brackets including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S & F viterous china Pedestral type pattern EWC white with 'P' or 'S' trap front or back inlet ( excluding flushing cistern and flush pipe) including PVC Sheet cover and provision of cement concrete bedding and making good surfaces complete all as specified and directed.
S & F in repair viterous china Pedestral type pattern EWC white with 'P' or 'S' trap front or back inlet ( excluding flushing cistern and flush pipe) including PVC Sheet cover and provision of cement concrete bedding and making good surfaces complete all as specified and directed.
Supply & Fix in repairs Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests complete all as specified and directed.
Supply & Fix for Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests on floor fixed with using PCC filling and trap etc complete all as specified and directed.
S&F in repair for PVC low level flushing cistern 10 lts capacity with ball valve float and handle ,syphonic action type including brackets and flush pipe of polythelene of low or high density or PVC 32 mm dia low level flushing cistern fixed in repairs all as specified and directed.
S&F for PVC low level flushing cistern 10 lts capacity with ball valve float and handle ,syphonic action type including brackets and flush pipe of polythelene of low or high density or PVC 32 mm dia low level flushing cistern all as specified and directed.
S&F in repair for vitreous china wash hand basin ,white, flat back, size 550x400 mm including chain and plug and porcelain stopper, brackets including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F for vitreous china wash hand basin ,white, flat back, size 550x400 mm including chain and plug and porcelain stopper, brackets including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F in repair for PVC connection 15mm bore with PTMT nuts and 600 mm long complete all as specified and directed.
S&F for PVC connection 15mm bore with PTMT nuts and 600 mm long complete all as specified and directed.
S&F for CP Brass connection 15mm bore with PTMT nuts and 600 mm long complete all as specified and directed.
S&F In repair for tubular towel rail 20 mm dia 600 mm long brass CP including brackets fixed complete all as specified and directed.
S&F for tubular towel rail 20 mm dia 600 mm long brass CP including brackets fixed complete all as specified and directed.
S&F for spreader for urinal , 15 mm dia chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair for bib taps, 15 mm dia chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F for bib taps, 15 mm dia chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F 15 mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair for brass chromium plated shower rose 125mm size complete all as specified and directed.
S&F for brass chromium plated shower rose 125mm size complete all as specified and directed.
S&F in repair for 15 mm concealed stop cock of chromium plated fancy type copper alloy screwed down high pressure for iron pipe or for unions fixed complete all as specified and directed.
S&F for 15 mm concealed stop cock of chromium plated fancy type copper alloy screwed down high pressure for iron pipe or for unions fixed complete all as specified and directed.
S&F in repair for 15 mm stop/angle cock of chromium plated fancy type copper alloy screwed down high pressure for iron pipe or for unions fixed complete all as specified and directed.
S&F for 15 mm stop/angle cock of chromium plated fancy type copper alloy screwed down high pressure for iron pipe or for unions fixed complete all as specified and directed.
S&F in repair for chromium plated grating doom 100 mm dia complete all as specified and directed.
S&F for chromium plated grating doom 100 mm dia complete all as specified and directed.
S&F PVC nahani trap 75 mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and directed.
S&F rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered white colour 500ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foudation and making GI tubing inlet or outlet connection complete all as specified and directed.
S&F rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered white colour 1000 ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foudation and making GI tubing inlet or outlet connection complete all as specified and directed.
M&L for cutting chases/pinning in brick wall for concealed water tubing n.exc 10cm girth and making good facing where required and pointing in CM 1:3 complete all as specified and directed.
S&F tubes `medium grade' galvanised with all fittings and fixed complete to walls and ceiling or laid in floors 20mm bore complete all as specified and directed.
S&F tubes `medium grade' galvanised with all fittings and fixed complete to walls and ceiling or laid in floors 15mm bore complete all as specified and directed.
S&F 20 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
S&F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for waste pipe complete all as specified and directed.
S&F 75 mm PVC SWR pipe single socketed in any length with rubber ring joints laid in walls complete all as specified and directed.
S&F 75 mm PVC SWR pipe single socketed in any length laid in trenches or in floors complete all as specified and directed.
S&F 110 mm PVC SWR pipe single socketed in any length with rubber ring joints laid in walls complete all as specified and directed.
S&F 110 mm PVC SWR pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F 75 mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F 75 mm dia PVC (SWR) Tee any radius complete all as specified and directed.
S&F 110 mm dia PVC (SWR) Tee any radius complete all as specified and directed.
S&F 110 mm dia PVC (SWR) Cowl complete all as specified and directed.
S&F125/110 mm PVC (SWR) gully trap, setting and jointing with solvent cement complete all as specified and directed.
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F for Box type steel Ventilator with 80x40x1.25mm MS Rectangular hollow section with side hung shutters (single shutters for glass ) with out sash bars jointed together with and including grills using 12mm square bars @ 10cm C/C Ref TD No CEBZ/TD/14/ 2011 including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 150 mm aluminium handle cast type anodized complete all as specified and directed.
S&F Aluminium anodised, barrel tower bolts of extruded section of length 150 mm and fixed with cadimium plated wood series, complete all as specified and directed.
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S&F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1no.) complete all as specified and directed.
S&F 6.3 mm thick coloured sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 4mm thick pin headed glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F Stainless steel wire cloth.0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed.
M&L for mild steel section as in frame for shed(truss) and steel gate including all necessary machine wks i.e. cutting, welding, grinding etc, complete all as specified and directed.
M&L for 12mm prelaminated particle board, exterior grade, prelaminated both side balancing white lamination, fixed with screws to Aluminium frame work complete all as specified and directed.
M&L for preparing new plastered surface of wall and applying two coats of weather proof exterior grade emulsion paint over and including a coat of cement based primer, complete all as specified and directed.
M&L for preparing new plastered surface of wall and applying two coats of cement base paint complete all as specified and directed.
M&L for preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer including 2mm thick putty to make the surface to be plain and smooth complete all as specified and directed
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for complete removal existing plastered surfaces of wall and applying two coats of weather proof exterior grade emulsion paint over and including a coat of cement based primer, complete all as specified and directed.
M&L for complete removal existing surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for complete removal existing surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L water proofing treatment to roof slab with APP based modified polymeric membrane centre core 100mm microne HMHDPE outer flim 20 micron each having thickness 3 mm weight not less than 3kg/Sqm with 100mm overlap laid as per manuacturer's instructions and complete all as specified and directed with following course of description below:- (a) 1st coat applying bitumen primer confirming to IS-3384-1965 @ 0.40 Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated. (b) 2nd coat of bonding material using blown type bitumen conforming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm. (c) 3rd course ie. laying of APP Based modified membrane described herein before with 100mm overlap in longitudinal direction and 150mm in transverse direction, all joints and changes in all direction should be covered covered with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane. (d) Applying one coat of bituminious aluminium paint @ 0.20 Kg Per Sqm over APP membrane,
M&L for rendering 15mm thick fair finished using cement mortar (1:4) with WPC on flat roof slab complete all as specified and directed.
M&L 75mm thick for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection and path laid in alternate panels not more than 3 mtr in length, laid to slope 1:30 including forming joints 10 mm wide and upto full depth of PCC and filled with bitumen mastic (1:3) 1 part bitumen 85/25 and 3 parts of sand complete all as specified and directed. {Note:-Rate is deemed to be inclusive of materials against forming & filling of joints}.
M&L for Green marble 18/20 mm thick in steps, pillars, wndow cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide complete all as specified and directed.
M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 (Nominal mix) using 20 mm graded crushed stone aggregate for 150 mm bore pipes complete all as specified and directed.
M&L Salt glazed stoneware (SGSW) drain pipes 150 mm bore laid and jointed on concrete bed, complete including testing etc complete all as specified and directed. (Concrete bed shall be measured and paid for separately).
M&L for Precast cement concrete type B-1, 1:2:4 (Nominal mix) using 20 mm grade crushed stone aggregate, as in cover slabs (for manhole etc.) casted at site and setting in cement mortar 1:4 complete all as specified and directed.
Construction of Soakage wells exc,in ordinary soil,foundation in PCC 1:3:6 ,wells of honey combed and solid in M-25 concrete,including intercepting chamber,screen chamber Brick work in CM,RCC cover slab in M-25/ Brick masonary/Filling with brick bats ,complete of size (1.2 m dia x 3.0 M deep) for 25 users complete all as specified and directed as per TD Drg No CEJZ/TD/58 Sheet No 1/1.
Cutting into existing manhole for connecting new drain pipe of internal dia pipe of150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel(1/2 round) in cement concrete 1:2:4 type B1 smooth finished and reforming benching complete all as specified and directed.
Construction of Septic Tank of 25 Users with provn of excavation, in any type of soil, foundation in PCC 1:4:8, walls of fly ash brick masonry with top cover of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCI complete as per TD drawing complete all as specified and directed as per TD Drg No CEJZ/TD/57 Sheet No 1/4.
M&L for 75mm PVC Pipe heavy duty as weep hole complete all as specified and directed.
Rolling and consolidating path formation with hand roller 0.2 to 0.5 tone including, filling in, hollows and depression which occur during the process of rolling complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block rubberised any shape and size with white cement cement and pigment comfirming to IS 658-2006 of 60mm thick M-35 grade complete all as specified and directed.
M&L for 50mm thick sand filling as cushioning to interlocking including watering and consolidation complete all as specified and directed.
M&L for laying precast kerb stones of size 450x150x300mm in PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate finished fair and even and jointed in CM 1:4 complete all as specified and directed.
Rolling and consolidating road formation in cutting only with power roller 8-10 tone including, filling in , hollows and depression which occur during the process of rolling complete all as specified and directed.
M&L for laying kerb stone of sand stone , size 450x150x300mm in all surface hammer dressed so that the maxium depression from a straight edge held against the dressed surface shall not exeed 20mm jointed in CM 1:4 and struck flush complete all as specified and directed.
150mm thick ( spread thickness) soling with broken boulders or quarried stone 80mm to 40mm size intersticks filled, surface formed, rolled & consolidated with 8 to 10 tone power roller to required gradient & camber complete all as specified and directed.
150mm thick ( compacted thickness) water bound macadam complete laid in two separate layer each layer of 75mm compacted thickness with coarse aggregate of grading 2 ( 63 to 40mm size ) for 1st layer and of grading 3( 50 to 20 mm size) for second layer,( surfaces of each layer will be blinded with screening and moorum ,watered consolidated and compacted separately), spread rolled and consolidated to required gradient and camber using granite trap or basalt stone with 8 to 10 tone power roller complete all as specified and directed
M&L for laying premix bituminous, macadam with paving bitumen VG 30,as 4% of total mix laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less) complete all as specified and directed.
M&L preparing surfaces ( unsurfaced water bound macadam) by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surfaces with gunny gags to remove all loose dirt etc and applying evenly a priming/tack coat with bituminous primer at 10 kg per 10 sqm using paving bitumen VG 10 complete all as specified and directed.
M&L for Bituminous premix asphaltic semi dense concrete 40mm consolidated thickness with 5.5% binder content by weight of total mix, using paving bitumen VG30 of any penetration laid/spread uniformly by means of mechanical pavers over primed WBM surfaces rolled and compacted to required camber and gradient, complete 10 to 12 ton power roller complete all as specified and directed.
M & L thermo plastic center or edge line, marking (reflective type) of 2.5 mm thickness of uniform finishing with machine conforming to BS 3262 (Part-I) 1989 read with most specification of 803 clause 4.2.1 and 4.2.2 on bituminious surface in white / yellow/ red colour and super imposed with glass slam beats conforming to BS 6088 and most specification 803 clause 4.3.3 including cleaning of surface by removing all dust dirt oil grease etc including removing of existing marking with spirit / kerosene / gas burner or mechanically on bituminious surface complete all as specified and directed.
Repair to pot holes any depth, not exc 1.0 sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads , paths etc. cutting around edges to at least 25mm in deth making good by applying tack coat at 5 kg per 10 sqmwith using VG 10, laying 30 mm thick consolidated thickness,Bitumineous pre mixes semi dense Asphalticconcrete with 5.5 precentage of binder conndent VG 30 by weight of total mix and by using hot mix process and laid by by Mechanical paver Roller and compacted with 8 to 10 power roller to required camber and Gradient for uniform smooth surface complete all as specified and directed.
M&L preparing black top surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surfaces with gunny gags to remove all loose dirt etc and applying evenly a priming/tack coat with bituminous primer at 5 kg per 10 sqm using paving bitumen VG 10 complete all as specified and directed.
M&L for providing bituminous premixed asphaltic semi dense concrete (design mix) 30mm consolidated thickness with 5.5% binder content by weight of total mix, using paving bitumen VG30 of any penetration laid/spread uniformly by means of mechanical pavers over primed black top surfaces rolled and compacted to required camber and gradient, complete 10 to 12 ton power roller, complete all as specified and directed.
S&F in repair for CAT Eyes (Road Stud), of size (90mm x 110mm x 17mm Approx) ,made of polycarbonate with electronically welded prismatic retro-reflective lens on both side for maximum retro-reflection in wet and dry conditions, non breakable, dustproof type, fixed with epoxy chemical, cement and hardner, complete all as specified and directed.
S&F of Solar road Stud of size 125x125x25 mm, made out of toughened aluminium alloy body with polycarbonate top cover, IP 65 protection against water ingress, having 03 No super bright LEDs on each side, coloured reflective LED cover, inbuilt rechargeable battery, solar panel, visibility up to 800 mtr, automatically turns on at night and turns off at dawn, flashing for min 3 days once fully charged, suitable for night & adverse weather condition and fixed with epoxy chemical, cement and hardener complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass /GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed for the following points:-
One light point controlled by one switch.
One Exhaust fan point controlled by one switch.
One ceiling fan controlled by one switch and one regulator.
One 6A socket point controlled by one switch on independent board.
One 6A socket point controlled by one switch on same board.
All as per Ser item no. 155 here-in-before but with 2.5 sq mm FRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 4 sqmm + 1 run x 4 sqmm with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
Notes for item No. 155 to 157 (a) Quoted rate shall deemed to incude the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (b) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & caping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (c) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing caping may be used in that portion.
S&F, Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed.
S&F, Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed.
S&F, Socket, 6 pin, 6/16 Amp, multipurpose 240 volts, complete all as specified and directed.
S&F, Socket, two-in-one, 5 pin, 6 Amp, universal type, 240 volts, complete all as specified and directed.
S&F, angle holder, metal cased, bakelite body, 240 volts, complete all as specified and directed.
Supply and fix electronic fan regulator in 5 steps, 240V, 50Hz complete all as specified and directed.
S&F, Ceiling rose, three terminals, bakelite body, 240 volts, complete all as specified and directed.
S & F 7W White LED retrofit lamp suitable for B-22 holder base with polycarbonate diffuser and aluminium heat sink complete all as specified and directed.
Supply and fix LED batten box type with CRCA sheet steel body pre-wired suitable for and including provision of 1x20/22Watt (4 feet) retrofit LED tube with PC body and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix LED building security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP 65degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and directed.
Supply and fix in replacement of LED bulkhead luminaire in die-cast aluminium alloy body heat resistant prismatic glass cover, with specially designed gasket for minimum IP 55 degree of protection suitable for and including provision of 7W retrofit LED bulb, full white with B22 lamp holder complete all as specified and directed.
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed.
Supply and fix in replacement of ventilating fan with plastic body with louvers, 250mm sweep, single phase, 230 volts, 50 Hz. complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply, installation & testing of Electric Water Heater storage type, vertical, 25 Liters capacity, minimum 3 Star rated, with heating element upto 2 KW, PUF insulation, multifunction safety valve, adjustable knob for temparature setting and mild steel inner tank and outer body suitable for operating on 230V, 50 Hz, single phase AC supply including hot & cold water PVC connections and mounting on wall with suitable size & No. of anchor bolts complete all as specified and directed.
Supply and fix MCB distribution board, TPN, 4 way 415 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply and fix MCB distribution board, SPN, 8 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separetely.
Supply and fix MCB distribution board, SPN, 4 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separetely.
S& F MCB TPN 63 Amp, 10 KA, 'C' curve, 415 V, 50 Hz complete all as specified and directed.
S& F MCB SPN 40 Amp, 10 KA, 'C' curve, 230 V, 50 Hz complete all as specified and directed.
S& F MCB SP 6 to 32 Amp, 230 V complete all as specified and directed.
Supply, laying, testing & commissioning of Power Cables, Aluminum Stranded Conductor 25 sqmm, 4.0 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V grade as per IS 7098 (Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / OH line / transformer bushings and testing on completion all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing unserviceable service cable of any description complete all as specified and directed.
Supply, laying, testing & commissioning of Power Cables, Aluminum Stranded Conductor 16 sqmm, 2.0 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V grade as per IS 7098 (Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / OH line / transformer bushings and testing on completion all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 10 sq. mm nominal cross section, 2 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing unserviceable service cable of any description complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Material and labour for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply and fix exhaust fan, 300mm sweep with 04 Nos of blade leafs, 70 W power consumption, 1300 to1400 RPM, 100 % copper winding heavy duty motor with double ball bearings including supply and fixining of metallic louvers and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable from ceiling rose to connector of fan complete all as specified and directed.
Supply and erection of Hot dip galvanized tapered octagonal pole of height 7.0 mtrs in single or double section having top dia 70mm and bottom dia 130mm made up of 3mm thick sheet and welded with a base plate of size 200mm x 200mm x 12mm thick and provided with 1000mm long single arm bracket with 15 degree of angle for mounting street light fitting complete with provision of 04 Nos of ‘J’ type foundation bolts of size not less than 20mm dia, 600mm long embedded in RCC foundation concrete as per manufacturer’s recommendation including necessary earth work, RFR etc complete. A door should be provided at a height of 500mm from the base plate for accommodating and including provision of TPN aluminium bus bar system suitable for connecting up to 4 core, 16 sqmm aluminium cable and 01 No. of 6A SP MCB for street light protection inside the pole shaft including provision of 3 core, 1.50 sqmm PVC insulated PVC sheathed copper conductor cable 1100 volts grade confirming to IS:694 from pole junction box to street light fitting drawn through inside of pole . Radium reflector band / strips of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from base plate. Numbering of pole shall be done in black colour on yellow background at suitable place on the pole complete as specified and directed. Note: The quoted rate shall deemed to be inclusive of RCC foundation concrete, necessary excavation, erth work & RFR etc complete as per manufacturer's recommendation. Contractor shall submit the pole drawing and foundation drawing as per manufacturer's recommendation for approval of GE before procurement.
Supply and connect of 1100 volts grade heavy duty cable PVC insulated stranded copper conductor PVC round sheathed (flexible) industrial cable of size 1.5 sqmm, 3 core complete all as specified and directed.
Supply and fixing of 70 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying complete all as specified and directed.
Supply, install, commissioning and testing Mortuary cabinet suitable for single phase, 230 V, 50 Hz, with 0.55 mm thick exterior & interior finish pre painted GI sheet, 0.5 mm thick front finish in stainless, including vapour proof incandescent lamp, electric temperature indicator cum controller, 3 phase carriage assembly, one piece stainless steel tray, inbuilt power panel etc. suitable for unitary type refrigeration system and temperature range of 4-6ºC of capacity 02 Body complete all as specified and drected.
Supply, install, testing and commissioning of air cooled split type air conditioners with invertor technology electric driven (250 Volts, single phase, 50 HZ supply) with energy efficient rotary compressor, working on R-134 or superior enviornment-friendly refrigerant, codless remote operated, comprising of indoor unit,wall mounted, material of construction of indoor unit ABS, Nominal cooling capacity 6000 KCal/Hr, Minimum Power consumption, Minimum room discharge airflow 700 CuM /Hr Guranteed cooling capacity(Min) 5700 KCal/Hr, outdoor unit, Material of Cabinet GI Sheet 1.0 mm thick powder coated, Copper tubing, electric connection (Between indoor and outdoor unit located upto a maximum distance of 10 Meters) and condensate water drainage arrangement, etc complete with min 3 star rating of capacity 2.0 Ton complete all as specified and directed at site. Note :- The outdoor unit shall be fixed on wall with standard bracket or fixed on roof /floor with proper MS angle iron stand. The cost is deemed to be included in the quoted rates.
M&L for GI water tubing, medium grade, ISI marked of size 25 mm dia with and including all fittings i.e. sockets, bend, tee, elbow, reducer, union, nipple etc as per site requirement laid in trenches/floor or on wall, complete all as specified and directed. Note : 1. The excavation & earthwork shall be measured & paid for separately. 2. The cost of all type of GI fitting i.e. bend, tee, elbow, reducer, union, nipple etc is deemed to be included in quoted rates.
M&L for GI water tubing, medium grade, ISI marked of size 20 mm dia with and including all fittings i.e. sockets, bend, tee, elbow, reducer, union, nipple etc as per site requirement laid in trenches/floor or on wall, complete all as specified and directed. Note : 1. The excavation & earthwork shall be measured & paid for separately. 2. The cost of all type of GI fitting i.e. bend, tee, elbow, reducer, union, nipple etc is deemed to be included in quoted rates.
Supply and fix in replacement of Gun-metal, gate valves, with iron wheel head, screwed both ends for iron pipe of size 25 mm and fixed complete all as specified and directed.
Supply and fix in replacement of Gun-metal, gate valves, with iron wheel head, screwed both ends for iron pipe of size 20 mm and fixed complete all as specified and directed.
Cutting and screwing of existing steel tubing for alterations or additions of size 40 or 50 mm done in position without taking down and inserting tee branch connection complete all specified and directed.
Raja enterprises
NIHAL ENTERPRISES
SHIV SHANKAR MISHRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .