Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹16.0 L+₹73,215 (4.80%)Rejected-Finance | L2 | Rejected-Finance Being Other Than L1 | |
| 3 | L3₹17.4 L+₹2.2 L (14.3%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L3 | Rejected-Finance Being Other Than L1 | |
| 4 | L4₹17.9 L+₹2.6 L (17.2%)Rejected-Finance MASTER BUILDING DALHOUSIE ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being Other Than L1 | |
| 5 | L5₹18.3 L+₹3.0 L (19.9%)Rejected-Finance | L5 | Rejected-Finance Being Other Than L1 |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
19 Mar 2020, 6:00 pmClosed
GE(AF) PATHANKOT
GE(AF) PATHANKOT-145001
REPAIR/ REPLACEMENT/ MAINT OF CHLORINATION PLANT, SUBMERSIBLE PUMP, MOTOR, PIPE LINES AND OTHER CONNECTED ITEMS AT AFS PTK
2020_MES_317809_2
GE/PAF-52/2019-20
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE(AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE(AF) PATHANKOT
₹43,000
Yes
27 Apr 2020
29 Feb 2020
21 Mar 2020
29 Feb 2020
19 Mar 2020
5 Mar 2020
Amount
Excavation in trenches for taking out/laying of pipe line not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in soft/ loose soil complete all as specified and directed by Engrs-In-Charge.
Returning filling including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each layer of soft/loose soil complete all as specified and directed by Engrs-In-Charge.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engrs-In-Charge.
Taking out unserviceable CI/DI water pipe line of any grade 150 mm bore including all clearing for re fixing or removal to store complete all as specified and directed by Engrs-In-Charge.
Taking out unserviceable CI/DI water pipe line of any grade 80 mm to 100 mm bore including all clearing for re fixing or removal to store complete all as specified and directed by Engrs-In-Charge.
Taking up or down unserviceable GI water pipe line of any grade 40 mm to 50 mm bore including all cleaning for re fixing or removal to store complete all as specified and directed by Engrs-In-Charge.
Taking up or down unserviceable GI water pipe line of any grade 15 mm to 25 mm bore including all cleaning for re fixing or removal to store complete all as specified and directed by Engrs-In-Charge.
Laying only CI pipe spigot & socket) of any grade 150 mm bore in trenches (Obtained from Srl item No 4) after cleaning complete all as specified and directed by Engrs-In-Charge.
Laying only CI pipe Spigot & Socketof any grade 100 mm bore in trenches (Obtained from Srl item No 5) after cleaning as complete all as specified and directed by Engrs-In-Charge.
Laying only CI Pipe Spigot & Socket of any grade 80 mm bore in trenches (Obtained from Srl item No 5) after cleaning as complete all as specified and directed by Engrs-In-Charge.
Laying only GI tubing of any grade 50 mm bore with all new fitting in trenches (Obtained from Srl item No 6) after cleaning complete all as specified and directed by Engrs-In-Charge.
Laying only GI tubing of any grade 40 mm bore with all new fitting in trenches (Obtained from Srl item No 6) after cleaning complete all as specified and directed by Engrs-In-Charge.
Laying only GI tubing of any grade 25 mm bore with all new fitting in trenches (Obtained from Srl item No 7) after cleaning complete all as specified and directed by Engrs-In-Charge.
Laying only GI tubing of any grade 20 mm bore with all new fitting in trenches (Obtained from Srl item No 7) after cleaning complete all as specified and directed by Engrs-In-Charge.
Laying only GI tubing of any grade 15 mm bore with all new fitting in trenches (Obtained from Srl item No 7) after cleaning complete all as specified and directed by Engrs-In-Charge.
Supply and fixing ductile iron pipe 150 mm bore of any type as per site requirement including joints at both ends K-7 in any length as per latest IS specification laid in trenches complete all as specified and directed by Engrs-In-Charge.
All as per Item No 16 above but size of 100 mm bore complete all as specified and directed by Engrs-In-Charge.
All as per Item No 16 above but size of 80 mm bore complete all as specified and directed by Engrs-In-Charge.
Supply and fixing in replacement MS pipe 150mm bore heavy grade with both side flanged end and having 3 metre length including S&F of suitable size nut, bolts and washers laid in trenches/vertical on wall including taking down existing complete all as specified and directed by Engrs-In-Charge.
50 mm bore Mild steel tube medium grade galvanised with all fitting laid in trenches complete all as specified and directed by Engrs-In-Charge.
40 mm bore Mild steel tube medium grade galvanised with all fitting laid in trenches complete all as specified and directed by Engrs-In-Charge.
25 mm bore Mild steel tube medium grade galvanised with all fitting laid in trenches complete all as specified and directed by Engrs-In-Charge.
20 mm bore Mild steel tube medium grade galvanised with all fitting laid in trenches complete all as specified and directed by Engrs-In-Charge.
15 mm bore Mild steel tube medium grade galvanized with all fitting laid in trenches walls and ceilings or laid in floors complete all as specified and directed by Engrs-In-Charge.
Cutting of cast iron pipe 80 mm dia to required length before laying pipe including insertion of TE/valve collar as required at site and making the joint unleakpoof complete all as specified and directed by Engrs-In-Charge.
Cutting of cast iron pipe 100 mm dia to required length before laying pipe including insertion of TE/valve collar as required at site and making the joint unleakpoof complete all as specified and directed by Engrs-In-Charge.
Cutting of cast iron pipe 150 mm dia to required length before laying pipe including insertion of TE/valve collar as required at site and making the joint unleakpoof complete all as specified and directed by Engrs-In-Charge.
Supply and fix in replacement of 50 mm bore gate valve Gun metal screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specified and directed by Engrs-In-Charge.
Supply and fix in replacement of 40 mm bore gate valve Gun metal alloy screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specified and directed by Engrs-In-Charge.
Supply and fix in replacement of 25 mm bore gate Gun metal alloy screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specified and directed by Engrs-In-Charge.
Supply and fix in replacement of 20 mm bore gate Gun metal alloy screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specified and directed by Engrs-In-Charge.
Supply and fix in replacement of 15 mm bore gate Gun metal alloy screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specified and directed by Engrs-In-Charge.
Construction of brick valve pit of size 60 x 60 x 60 cm internal dimensions with 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded broken stone aggregate sub base of floor, 50 mm PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregae) in floor finished even and fair without using extra cement one brick work in CM 1:4 rending 15 mm thick plaster in CM 1:4 including 3 mm thick MS sheet pit frame 40x40x6 mm thick complete with locking arrangement having provision of lifting handle including 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surface and excavation in soft/loose soil, returning filling and removal of surplus soil up to 500 mtr distance complete and all as specified shown in Drg No CEAF/TD-52/2002 Sheet 1/1 dated 07.12.2002 revised upto 01.12.2010.
All as per Srl item No 33 above but Valve pit of Size 90x90x90 cm complete all as specified and directed by Engrs-In-Charge.
Cast iron bends (any type radius and angle) taper any type (Straight) bend increasing Per decreasing or double socket etc Tee peces, single branch 'Y' junction double branch, coller, Kg capacity and plugs for 80 mm bore to 150 mm bore CI pipe conforming to IS-1538-1976 complete all as specified and directed by Engrs-In-Charge.
Replacement of 150 mm bore sluice valve type PN-1 double Flanged cost iron type with brass spindle and iron wheel and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete all as specified and directed by Engrs-In-Charge.
All as per Srl item No 36 above but of Size 100 mm bore complete all as specified and directed by Engrs-In-Charge.
All as per Srl item No 36 above but of Size 80 mm bore complete all as specified and directed by Engrs-In-Charge.
Run lead joint to 150 mm bore complete including all necessary packing materials and making the joint unleakproof and all as specified and directed by Engineer-in-Charge
Run lead joint to 100 mm bore complete including all necessary packing materials and making the joint unleakproof and all as specified and directed by Engineer-in-Charge.
Run lead joint to 80 mm bore complete including all necessary packing materials and making the joint unleakproof and all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of 150 mm bore Non returen valve double Flanged cost iron type and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete all as specified and directed by Engrs-In-Charge.
Taking out submersible pump set 20 HP to 40 HP from the bore well in any depth complete with column pipe and other connected part and lowering the same after repair of the pump complete all as specified and directed by Engrs-In-Charge.(Note: Required T&P for above work and transportation to workshop and taking back is deemed to be included in quoted rates)
Strip opening 3 phase 20 to 40 HP capacity AC submersible motor taking out burnt winding coils complete and rewinding with insulated water proof winding wire matching with existing size including seal PVC (water proof compound) reassembling the motor and testing at workshop complete all as specified and directed. (Note: Insulation to wires, windings, varnishing,and other items required for rewinding and making motor water proof not mentioned in description and T&P required for this job is deemed to be included in quoted rates.)
Supply and replacement thrust plate matching with existing size suitable for 20 to 40 HP electric Motor complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Stud with nuts including spring washer matching with existing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Water seal suitable for submersible motor matching with existing complete all as specified and directed by Engineer-in-Charge.
Strip opening of pump of any type of submersible/centrifugal motor 20 HP to 40 HP of any stage/ size/ make and re assembling including replacement of defective items and reassembling complete after repair including testing at workshop complete all as specified and directed by Engr-In-Charge. (Note major defective items replaced will be measured and paid seperately under respective item of schedule, cost of items not mentioned in schedule and to be replaced is deemed to be included in quoted rates.)
Supply only following item No 49 to 56 to be fixed under item No 48 above complete all as specified and directed by Engr-In-Charge. (a) Pump shaft stainless steel for 20 to 40 HP pump matching with existing size
(b) Impeller bronze/ Gun metal for 20 to 40 HP pump matching with existing size
(c ) CI neck ring for 20 to 40 HP pump matching with existing size.
(d) Gun metal intermediate bush for 20 to 40 HP pump matching with existing size
(e)Suction/Discharge Bush for 20 to 40 HP pump matching with existing size.
(f) CI bowl for pump for 20 to 40 HP pump matching with existing size.
(g) Middle distance bush of stain less steel for 20 to 40 HP pump matching with existing size.
(h) Shaft coupling stain less steel for 20 to 40 HP pump matching with existing size.
Supply and lower submersible copper cable 16 Sqmm, 1100 volts,3 Core complete all as specified and directed by Engineer-in-Charge.
Supply and lower submersible copper cable 25 Sqmm, 1100 volts,3 Core complete all as specified and directed by Engineer-in-Charge.
S&F FASD starter oil immersed of capacity 40 HP with over load relay, contactors, timers, single phase preventer of suitable capacity prewired incl taking down the existing unserviceable starter incuding oil complete all as specified by Engr-in-charge.
S&F FASD starter oil immersed of capacity 25 HP with over load relay, contactors, timers, single phase preventer of suitable capacity prewired, incl taking down the existing unserviceable starter incuding oil complete all as specified by Engr-in-charge
S&F FASD starter panel suitable for three phase 40 HP submersible pump with over load relay having range of 36 to 60 Amps, coil voltage 380 to 415 volts, including contactors, timers, single phase preventer, voltmeter/ammeter of suitable capacity prewired incl taking down the existing unserviceable starter complete all as specified by Engr-in-charge.
S&F FASD starter panel suitable for three phase 30 HP submersible pump with over load relay having range of 30 to 50 Amps, coil voltage 380 to 415 volts, including contactors, timers, single phase preventer, voltmeter/ammeter of suitable capacity prewired incl taking down the existing unserviceable starter complete all as specified by Engr-in-charge.
Supply and fixing in replacement thermal over load relay suitable for oil immersed star delta starter for submersible pumps of rating 15 to 25 HP matching with existing sample including connections with existing star delta starters complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement thermal over load relay suitable for oil immersed star delta starter for submersible pumps of rating 30 to 40 HP matching with existing sample including connection with existing star delta starter complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement single phase prevention relay suitable for star delta starters, of capacity upto 40 HP, with auto, mannual and bypass operation, with time delay setting including wiring and connection with existing star delta starter complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement electronic timer suitable for star delta starters, having coil voltage 380 to 415 volts, with time delay 3 to 30 seconds, complete including wiring and connections with existing star delta starter complete all as specified and directed by Engr-In-Charge
Supply and replacement of union nut PVC for chlorine dosing system matching with existing sample complete all as specified and directed by Engineer in Charge
Supply and replacement of reducer for dosing pump all as per existing sample complete all as specified and directed by Engineer –in-Charge.
S&F in replacement of PumpTube of Decrin Dosing Pump matching with existing sample complete all as directed and specified by Engr-in- Charge .
S&F in replacement of Motor Agitator including shaft blades etc for chlorine dosing system matching with existing sample complete all as directed and specified by Engineer-in-Charge
S & F in replacement high density polyethylene pipe (HDPE) having pressure rating 6kgf/cm2 fixed complete to walls, ceilings or in floors from dosing pump to chlorine feeding point matching with existing sample complete all as specified and directed by Engineer-in-Charge
S&F in replacement single phase dosing pump including motor for chlorination of water matching with existing complete all as specified and directed by Engr-In-Charge.
S&F in replacement non return valve suitable for dosing system matching with existing sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement water level indicator suitable for Over head tank reservoir of capacity 100000 gallon on staging of height upto 60 ft, including all connected accessories i.e, float valves, sensors, level display boards etc, including wiring complete upto nearest pump house building at a distance maximum upto 100 mtr for display of level, buzzer for tank full indication, including all items required for proper functioning of digital water level indicator complete all as specified and directed by Engr-In-Charge.
Preparaton of oldsurfaces for painting of existing water supply pipe lines having dia 100mm to 150mm on outside of pipe lijne and applying two coats of synthetic enamelled paint of color as decided over one coat of primer red oxide complete all as specifed and directed by Engrs-in-Charge
Repair/ replacement of CCR system comprising of CCR lights, joints, panels, cable ducts and other connected items including cleaning of equipments/ lights etc as required by CCR Section by providing 02 (pers) Nos of tradesmen complete all as specified and directed by Engineer-in-Charge Note : (i) The work will be executed in technical area. Contractor is adivsed to quote rate accordingly and furnished daitils of workers police verificaton and qualification to the Engrs-In-Charge.
Removal of vegetation/ undergrowth/ bushes in the premises of E/M installatins by using mechanical bust cutter where deemed necessary and cleaning the creepers growing on fencing of the installation once in a month and removal of waste vegetation to nearest dustbin or location as decided with periodicity of once in a month complete all as specified and directed by Engineer-in-Charge. Note:- Any T & P and transportation required for removal of vegetation from installation is deemed to be included in the quoted rates, contractor is advised to quote rate accordingly)
Cleaning of bar screen chamber, oil and grease trap, grit and clarifier, removal of vegetation, debris, sludge for hinderance free operation of sewage treatment plant at 1 Area including removal of waste to nearest dump site as decided with periodicity of once in a month complete all as specified and directed by Engr-In-Charge. (Note: Required T&P, safaiwala's etc required for cleaning and removal is deemed to be included in quoted rates)
M/S V K TRADERS
SATISH AND CO
INDIA ELECTRIC WORKS
JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED
KALSI CONSTRUCTION CO
Vijay Kumar Contractor and Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .