Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.4 Cr+₹4.7 L (3.45%)Rejected-AOC | ₹1.4 Cr+₹4.7 L (3.45%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.6 Cr+₹20.9 L (15.2%)Rejected-AOC | ₹1.6 Cr+₹20.9 L (15.2%) | L3 | Rejected-AOC Rejected |
| 4 | Not Admitted-Fee/PreQual/Technical VILLAGE PO RAJAIN TEHSIL BHATTIYAT DISTT CHAMBA HP | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.6 Cr
EMD Value
₹1.9 L
Closing Date
19 Mar 2020, 11:00 amClosed
Executive Engineer
IPH Division Rohru
SH C O Development of site for various structure C o of head work C o Anchor Block C o Pump house cum attanet quarter 1stage and 2nd stage C o septic tank stage I and II Prov saintary protecion C o Retaining wall C o tanks main storage
2020_HPIPH_35589_1
IPH-RD-AB-Tender 20-12226-48
Open Tender
Civil Works
Item Rate
180 days
Rohru Town
Tender document
8 documents required · 8 mandatory
₹1,500
Yes
EE Rohru
₹1.9 L
Yes
15 Jun 2020
26 Feb 2020
19 Mar 2020
26 Feb 2020
19 Mar 2020
26 Feb 2020
Amount
Cutting in earth work and disposal of excavated earth work upto a lead of 20mtr(twenty metres) within all leads and lifts and as directed by the Engineer-in-charge.
Excavation in foundation trenches(for pipes & pits) upto all depths in all class fication of earth work such as pick work, jumper work, saturated soil including bailling and pumping out water, blasting soft/hard rock or chieselling soft/hard rock where blasting is protibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring/strutting, planking,timbering & dewatering wherever required, stacking the useable & unuseable material/soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15cm. layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil/unuseable material as directed within all leads and lifts including restoration unmetalled surfaces to its original condit on & including cost of diversion for traffic, night signal, fixing caution boards crossing over trenches for access to houses, fencing etc. complete in all respects within all leads & lifts as per direction of Engineer-in-charge.
Providing and laying cement concrete work 1:3:6(1cement:3approved sand:6approved graded stone agg.20mm nominal size)& curing complete excluding cost of form work in foundation and plinth within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying cement concrete 1:6:12(1cement:1.approved sand:6approved graded stone agg. 20mm nominal size) & curing complete excluding cost of form work in foundation and plinth:
Providing and laying CC1:5:10 (1cement,5sand,10graded stone agg.40 mm n/s)with 15% plum and curing complete excluding the cost of form work in retaining walls.Breast walls,the size of plum shall usually be 150mm to 300mm as per HPPWD specification.
Foundation and plinth Bed and wall ncluding attached buttress, pillasters and their caps and string cources etc. upto floor two level within all leads and lifts and as directed by the Engineer-in-charge 1:1:5:3.
Foundation, footings basis of columns etc. and mass concrete within all leads and lifts and as directed by the Engineer-in-charge.
Column pillar & post upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Suspended floor roofs landing and shelves and their support balconies, beams, girders, bressumers and cantilever upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Stair cases (except spiral stair cases)excluding landing but including preparing of the surface and finishing of nosing upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Walls including attached buttress, pillasters and their caps and string courses etc. upto floor to level within all leads and lifts.
ii) Walls(any thickness but ot less than 0.1 mtr thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level.
Tank base
Tank wall
Providing mild steel/tor steel for RCC work including bending binding and placing in p[osition complete upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Providing form work with steel plate 3.15mm thick welded with angle iron frames 30x30x5mmso as give a fair finish i/c centring, shuttering, ¢ring below supporting floor to ceiling not exceeding 4mtrs. &removal of the same for in-situ reinforced concrete & plain concrete work in:
Foundation, footings basis of columns etc. and mass concrete within all leads and lifts and as directed by the Engineer-in-charge.
Column pillar & post upto floor two level square, rectangular & polygonal in plain within all leads and lifts and as directed by the Engineer-in-charge.
Beams, cantilever girders & lintals sides & soffits of beams, beams haunching cantilever girders not exceeding 1mtr. Depth within all leads and lifts and as directed by the Engineer-in-charge.
Vertical surface such as wall(any thickness) partitions and the likeincluding attached pillasters, buttresses, plinth and string cources and thelike within all leads and lifts.
Flat surface such as soffits of suspended floor, roofs, landing and the likefloor etc. upto 200mm in thickness within all leads and lifts.
Edges of slab and breaks in floors and walls under 20cm. Wide within all leads and lifts.
Slopping or battering surfaces including folded plastes:Where inclination to horizontal plane does not exceed 30degree within all leads and lifts and as directed by the Engineer-in-charge.
Stair cases with sloping or stepped soffits excluding landing beams, cantilever, girders and Lintels within all leads and lifts and as directed by the Engineer-in-charge.
Half brick masonry in common burnt clay building brick in cement mortar 1:4(1cement:4sand) 1st.class brick within all leads and lifts and as directed by the Engineer-in-charge.
Dry brick /boulder filling round soak pit 2nd class with in all leads and lifts as per the directions of the Engineer in charge.
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25mm thickness i/c hinges jump lock jamb, beed and if required angle threshold of mild steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by mechanical means, adjustable luge with split and tails to each jamb i/c steel but things 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of approved steel primer after pretreetment of the surface as directed by the Engineer-in-charge.
Profile-A.
Profile-B.
Profile-C.
Providing and fixing Pannelled and glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hinges with necessary screws 40mm thick: 2nd class deodar wood within all leads and lifts and as directed by the Engineer-in-charge.
P/F wire gause shutters using MS wire gause of IS gause designation 85 G for doors windows clerestorey windows I/c bright finished black enamelled iron hinges with necessary secrews 40 mm thick 2nd class deodar wood within all leads and lifts and as directed by the Engineer-in-charge.
10mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:3 (1cement:3sand)within all leads and lifts and as directed by the Engineer-in-charge.
15 mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)within all leads and lifts and as directed by the Engineer-in-charge.
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)within all leads and lifts and as directed by the Engineer-in-charge.
6 mm thick cement plaster in cement concrete 1:3( 1cement 3 sand in roof slabs within all leads and lifts and as directed by the Engineer-in-charge.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade i/c thoroughly brooming the surface to remove all dust dirt & other foreign matter within all leads and lifts and as directed by the Engineer-in-charge.
Distempering (two coats) with oil bond distemper of approved brand and manufacture and of required shade on undecorated wall surfaceto give an even shade over and including priming coat with distemper primer of approved brand and manufacture after throughly brushing the surface free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth. Priming coat with distemper primer within all leads and lifts and as directed by the Engineer-in-charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing 10mm thick antiskid water proof stain and impect resitent resistent heavy duty vetrified tiles Nitco or equivalent 600x600mmx10mm manufactured or approved shade and colour in flooring treads of steps and landings laid over (12mm thick cement mortar 1:3)(1Cement:3Sand)jointed with cement slurry mixed with pigment to match the shade of tiles as required complete within all leads and lifts and as directed by the Engineer-in- charge.
Providing and fixing 0.60mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating to back coat of polyster of 5microns over 5 micron premier coating including fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia mtr.with prepainted limpet and rubber washers complete with all accessories as required as per the direction of the Engineer-in-charge.
Providing and fixing ridges or hips 60cm over all with 0.60 thick prepainted steel sheet in roofing with bot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating to back coat of polyster of 5 microns over 5 miscron premier coating including fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia mtr.with prepainted limper and rubber washers complete with all accessories as required as per direction of Engineer-in-charge.
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter) sand papering and knotting:Readymixed paint brushing wood primer pink within all leads and lifts and as directed by the Engineer-in-charge.
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters white paint within all leads and lifts and as directed by the Engineer-in-charge.
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters readymixed paint other than white paint within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing of MS grill of required patttern in wooden frame of window etc. with MS rounded headed bolts and nuts or by screw: Plain Grill within all leads and lifts and as directed by the Engineer-in-charge.
Stone soling properly hand packed filling interstices with spalls and consolidating with power road roller to the required gradient and camber including spreading watering and rolling of binding materials moorum or earth etc. 100mm spread thickness (finished work including materials and labour) within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing anodized aluminium sliding door bolts withnuts and screws complete I) 250mmX16mm within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing anodized aiuminium. tower bolts barrel type with screws etc. complete within all leads and lifts and as directed by the Engineer-in-charge.
I) 200mmX10mm
ii) 100mmx10mm
Providing and fixing anodized aluminium .handles with screws etc. complete within all leads and lifts and as directed by the Engineer-in-charge.
I)125mm dia
ii) 100mm dia
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and as directed by the Engineer-in-charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Steel work welded in built up sections, trusses and framed work, including cutting, hoisting fixing in postion and applying a priming coat of red lead paint etc.
Wire crate mde of GI wire filled with boulders with square cut faces against the wire(Boulder filling to be measured and paid for separately)GI wire 5mm thick corresponding to SWG-6(15cmx15cm mesh) within all leads and lifts and as directed by the Engineer-in-charge.
Wire crate of GI wire filles with boulders with square cut faces against the wire(wire crates to be measured and paid for separately)within all leads and lifts and as directed by the Engineer-in-charge.
Boulder filling behind retaining wall & crate wall within all leads and lifts and as directed by the Engineer-in-charge.
Providing & Fixing of Finalax pipe 40mm dia. Under floor ( for connection cables) including all req. fitting i.e elbows, sockets etc.
Providing and placing horizontal layers filtering media duly graded screened washed and cleaned as specified by the Engineer Incharge with in all leads and lifts.
(i) Prov. Dry Bricks for filter bed/septic tanks
Coarse sand 3mm to 6mm
Providing and fixing vitreous China wash down water closet (European type. W.C. Pan) with integral 'P' or 'S' trap including jointing the trap with soil pipe in cement mortar 1:1 (1Cement : 1 Sand) (Seat and cover to be measured and paid for separately) Ordinary type.
Providing and fixing Stainless steel kitchen sink with drain board with in all leads and lifts as per the directions of the Engineer in charge. 470X 420X 178MM
Prorviding and fixing vitreous china wash basin with single hole for piller tap with C.I. or M.S. brackets painted white Flat back 630mmx450mm within all leads and lifts and as directed by the Engineer-in-charge.including cutting holes and making good the same but excluding fittings:-with in all leads and lifts as per the directions of the Engineer in charge.
Providing and fixing PTMT Coloured / white high density polyethlylene / poly propylene 10 liters cap. full flush European standard control low level flushing Cistern with fitting and within all leads and lifts and as directed by the Engineer in charge.
P/F C.P. brass waste for wash basin or sink (i)32mm diawith in all leads and lifts as per the directions of the Engineer in charge.
P/F C.P. soap dish with C.P. brass brackets fixed to wooden cleats With C.P. brass screws with in all leads and lifts as per the directions of the Engineer in charge.
P/F C.P. Brass Bib tap with capstan head(15mm dia) with in all leads and lifts as per the directions of the Engineer in charge.
P/F brass full wheel valve with capstan head(15mm dia)within all leads and lifts and as directed by the Engineer-in-charge,
P/F C.P. Angle cock 15mm dia within all leads and lifts as per the directions of the Engineer-in-charge,
P/F of GI Elbow 15mm with in all leads and lifts as per the directions of the Engineer in charge.
P/F of GI Tee15mm with in all leads and lifts as per the directions of the Engineer in charge.
P/F of GI Nipple 15mm with in all leads and lifts as per the directions of the Engineer in charge.
Laying galvanized mild steel tube (heavy class) in wall. Ceiling including with in all leads and lifts as per the directions of the Engineer in charge .15mm dia(fiifteen milimetres)nominal size.(H . C )
Providing and fixing 600mmx450mm bevelled edge miror of superior glass mounted on 6mm thick A.C. sheet or plywood sheet and fixed to wooden plugs with C.P. Brass screws and washers. within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing in trenches 10 Kg.f/cum2 working pressure unplasticized P.V.C. pipe (Conforming to IS: 4985-1968) complete fittings (earth work in trenches to be measured and paid for separately):-
110 mm out side diameter.
Elbow 100 mm dia.
Clamps 100mm dia.
. Door Bends
.Plain bends
Collar
.Floor Traps
Supplying and fixing galvanised steel barbed wire(IS: 278-1962 type-I)heighting 9.30 kg. per 100 mtrs. Straing and fixing to any type of standard rail, straining the belts, including, securing with and providing of GMS wire stapler etc.(past, of wood cement steel paid for separately).
Providing and laying cement concrete 1:2:4(1cement:2 approved sand:4approved graded stone agg. 20mm nominal size) & curing complete excluding cost of form work in foundation and plinth:
In suspended floor roofs landing shalves & their support balconies,beams, girders bressumers cantilevers upto floor two level
Supplying of various materials for pump house
Tool kit for pump house (24items ) with all accessory etc
Insulatiion mate ( 6x 4) Bearing puller insulation & gress gen 1 no each ofr pump houyse
poly chairs table & stool 1 no each for pump house
Welding set 1 no each for pump house
GNSS Model GEOMAX Zenith 40 (Brand GEOMAX)
Providing and laying cement concrete 1:4:8 (1 cement:4 sand :8graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation & plimnth.
P/F Main hole cover
Harsh Bhagta Govt. Contractor
CHATTER SINGH RATHORE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .