Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC L1 | |
| 2 | L2₹47.7 L+₹1.9 L (4.24%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹51.2 L+₹5.5 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹52.1 L+₹6.4 L (14.0%)Rejected-Finance OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹53.1 L+₹7.4 L (16.1%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
22 Jan 2024, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
SPECIAL REPAIR TO GUARD ROOM (BUILDING NO.P-301) AT INHS DHANVANTARI AND PROVISION OF PARKING SHED FOR VISITORS AT SHO UNDER GE MINNIEBAY PORT BLAIR
2024_MES_635318_1
8347/E8
Open Tender
Civil Works
Item Rate
180 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹86,000
Yes
12 Mar 2024
2 Jan 2024
24 Jan 2024
2 Jan 2024
22 Jan 2024
16 Jan 2024
Amount
Taking down existing roof treatment from roof and cleaning with wire brush to remove all loose particles and washing with water including removing the debris upto 100M distance complete all as specified and as directed by Engineer in Charge
M&L for plain cement concrete type B1 1:2:4 (using 20 mm graded stone aggregate) avg thickness 40mm in roof padding concrete,kerbs or mud stops, or rounded or chamfered on edge with WPC complete all as specified and as directed by Engineer in Charge
M&L for plastering in CM 1:3, 10 mm average thickness over the treated surface using water proofing compound as per manufacturers instructions including finished even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge Note: Water Proofing compound shall be measured and paid separately
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed by Engineer in Charge Note:Roof Treatment should be carried out by approved agency
Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and as directed by Engineer in Charge
M&L for formwork to sides of chajjas,chullah hoods and similar items incuding edges on rough finished square ,rectangular or polygonal surface complete all as specified and as directed by Engineer in Charge
M&L for RCC M-30 as in chajjas and similar items etc complete all as specified and as directed by Engineer in Charge
M&L for formwork to sides of beam , lintel beam , roof beam etc complete all as specified and as directed by Engineer in Charge
M&L for RCC M-30 as in beam , lintel , roof beam etc complete all as specified and as directed by Engineer in Charge
Demolition of precast concrete work/ precast concreteblock built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed by Engineer in Charge
M&L for precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and as directed by Engineer in Charge
Taking down cement plaster on walls any description incl racking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed by Engineer in Charge
M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 (river sand)and finished fair and even without using extra cement complete all as specified and as directed by Engineer in Charge
M&L for rendering 15mm thick cement plaster on fair faces of concrete block masnory in two layers, base layer 10mm thick in CM (1:6) and top layer 5mm thick in CM 1:4(with river sand) mixed with WPC as per manufacture' s instructions, finished even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge Note :- WPC shall be measured and paid seperately
M&L for rendering 15mm thick cement plaster on fair faces of concrete block masnory in two layers, base layer 10mm thick in CM (1:6) and top layer 5mm thick in CM 1:4(with river sand) mixed finished even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge
M&L for rendering 5mm thick in CM (1:3) on ceiling surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer in Charge
Supply only water proofing compound complete all as specified and as directed by Engineer in Charge
M&L for preparation of new surfaces on (G+3) bldgs providing necessary scaffolding & safety precautions and cleaning the surfaces free using wire brush and levelling the surface even and smooth using mechanical sander and finally applying water by pressure jet washer of max pressure of 170 bar with automatic pressure relief system. The following process shall be initiated only after the above surface preparations :- (a) Filling the surface cracks using crack seal compound on required consistency using electric mixer. (b) Filling the dents and holes using wall care putty in appropriate ratio using electric mixer.(c) Applying one or two coats of damp proof primer (primer coat) using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m.(d) Applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm Anti algal weather coat 100% acrylic smooth emulsion paint using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m.
Note : (i) Work shall be executed only through authorised applicator duly approved by Manufacturer of Paint and certificate in this connection shall be submitted by the Contractor. (ii) The affected area of the wall due to dampness shall be ascertained by moisture meter of power input 9v Display 60 LEDs using colour code scale and Moisture measurement of each location shall be submitted along with RAR. (iii) The contractor shall upload MOU letter with any one of Paint manufacturer within 28 days of receipt of acceptance copy failing which contract shall be liable for cancellation. Authorised applicator shall have valid authorisation letter from the manufacturer The authorisation letter needs to be valid for the complete period of execution of the painting work. (iv) After preparation of the surface, Engr-in-Charge shall inspect and approve the same before applying primer and finishing coats. (v) Building wise stage passing register shall be maintained & submitted alongwith RAR/FB duly signed by Engr-in-Charge and contractor. (vi) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into.The specification and details of the equipments and tools pertaining to this item is denoted on Particular Specification.Manual method of paint application is not allowed and also Penalty shall be levied if appropriate tools & equipments pertaining to smart periodicals not used. (viii) Proper masking arrangement shall be carried before the application of primer or paint. (ix) The other coat of Primer and Paint shall be applied only after the completion of drying time and comply with recoating period as per manufacturer instructions. (x) Cost of scaffolding upto (G+3) height of building shall be included in the quoted rate.
M&L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer and 2mm thick wall care putty complete all as specified and as directed by Engineer in Charge( Wall care putty shall be measured and paid separately)
M&L for preparation of newly plastered ceiling surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engineer in Charge
M & L for complete removal of existing treatment and treating with two coats of oil bound distemper over a coat of primer to wall surfaces including preparation of old surface of wall complete all as specified and as directed by Engineer in Charge
M&L for complete removal of old existing treatment/finishes on (G+3) bldgs providing necessary scaffolding & safety precautions and cleaning the surfaces free from any loose paint, dust,greases,growth of fungus,algae or moss using wire brush and levelling the surface even and smooth using mechanical sander and finally applying water by pressure jet washer of max pressure of 170 bar with automatic pressure relief system. The following process shall be initiated only after the above surface preparations :- (a) Filling the surface cracks using crack seal compound on required consistency using electric mixer. (b) Filling the dents and holes using wall care putty in appropriate ratio using electric mixer.(c) Applying one or two coats of damp proof primer (primer coat) using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m.(d) Applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm Anti algal weather coat 100% acrylic smooth emulsion paint using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m.
Note : (i) Work shall be executed only through authorised applicator duly approved by Manufacturer of Paint and certificate in this connection shall be submitted by the Contractor. (ii) The affected area of the wall due to dampness shall be ascertained by moisture meter of power input 9v Display 60 LEDs using colour code scale and Moisture measurement of each location shall be submitted along with RAR. (iii) The contractor shall upload MOU letter with any one of Paint manufacturer within 28 days of receipt of acceptance copy failing which contract shall be liable for cancellation. Authorised applicator shall have valid authorisation letter from the manufacturer The authorisation letter needs to be valid for the complete period of execution of the painting work. (iv) After preparation of the surface, Engr-in-Charge shall inspect and approve the same before applying primer and finishing coats. (v) Building wise stage passing register shall be maintained & submitted alongwith RAR/FB duly signed by Engr-in-Charge and contractor. (vi) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into.The specification and details of the equipments and tools pertaining to this item is denoted on Particular Specification.Manual method of paint application is not allowed and also Penalty shall be levied if appropriate tools & equipments pertaining to smart periodicals not used. (viii) Proper masking arrangement shall be carried before the application of primer or paint. (ix) The other coat of Primer and Paint shall be applied only after the completion of drying time and comply with recoating period as per manufacturer instructions. (x) Cost of scaffolding upto (G+3) height of building shall be included in the quoted rate.
M&L for applying 2 mm thick wall care putty over plastered surfaces wall/ ceiling to prepare the surface even and smooth complete all as specified and as directed by Engineer in Charge
M&L for preparing old steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer in Charge
Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and as directed by Engineer in Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding and rubbished off the premises complete all as specified and as directed by Engineer in Charge
M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate as in sub base for flooring/levelling coarse, sunken floor etc complete all as specified and as directed by Engineer in Charge
M & L for virified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors over 15 mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer in Charge
All as per item No.28.00 above but in vertical surface (dado/skirting) to match the shade of floor tiles laid over and including 10mm thick back coat in CM (1:4),complete all as specified and as directed by Engineer in Charge
M&L for glazed ceramic tiles 350 x 250x 7mm / 450x300x 7mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing in cement mortar (1:3) complete all as specified and as directed by Engineer in Charge
M&L for 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 20 mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer in Charge
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer in Charge
Taking down 15mm Steel /16mm CPVC tubing and connections complete all as specified and as directed by Engineer in Charge
Taking down 20mm Steel / CPVC tubing and connections complete all as specified and as directed by Engineer in Charge
Taking down 25mm Steel / CPVC tubing and connections complete all as specified and as directed by Engineer in Charge
Supply and laying of CPVC pipes 20 mm dia outer bore SDR 11 &plain CPVC SDR 11 fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in Charge
Supply and laying of CPVC pipes 25mm dia outer bore SDR 11 &plain CPVC SDR 11 fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in Charge
M&L for cutting chases in concrete block walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing etc., and making good, cutting not ecx 10 cm girth complete all as specified and as directed by Engineer in Charge
S&F 20 mm brass elbow complete all as specified and as directed by Engineer in Charge
S&F 20 mm brass elbow reducer(3/4 x1/2) complete all as specified and as directed by Engineer in Charge
S&F Male Brass Threaded Adaptor (MTA/MBTA) 20mm bore complete all as specified and as directed by Engineer in Charge
S&F Male Brass Threaded Adaptor (MTA/MBTA) 25mm bore complete all as specified and as directed by Engineer in Charge
S&F Female Brass Threaded Adaptor (FTA/FBTA) 20mm bore complete all as specified and as directed by Engineer in Charge
S&F Female Brass Threaded Adaptor (FTA/FBTA) 25mm bore complete all as specified and as directed by Engineer in Charge
Supply and fixing 20 mm outer dia Brass Tee complete all as specified and as directed by Engineer in Charge
Supply and fixing 25 mm outer dia tank Adaptor complete all as specified and as directed by Engineer in Charge
Supply and fixing 20mm outer dia union complete all as specified and as directed by Engineer in Charge
Supply and fixing 25mm outer dia union complete all as specified and as directed by Engineer in Charge
S&F in repair vitreous China wash down water closet pan (pedestal pattern) of size 380x610x805mm Rimless bowl with cistern for coupled, WC with UF soft close slim seat cover hinges, dual flush cistern fitting, conversion bend , fixing accessories and accessories set complete all as specified and as directed by Engineer in Charge
S&F in repair brass chromium plated Hand shower (Health Faucet)(ABS Body) with 1 Meter long Easy Flex Tube in Chrome Finish& wall Hook complete all as specified and as directed by Engineer in Charge
S&F in repair vitreous China urinals size 480x300x740mm with fixing accessories set complete all as specified and as directed by Engineer in Charge
S&F in repairs two way bib tap cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed by Engineer in Charge
S&F in repairs angular stop cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed by Engineer in Charge
S&F in repairs brass chromium plated shower rose with or without swivel joint 100mm size complete all as specified and as directed by Engineer in Charge
S&F in repair 15mm dia wall mixer cast copper alloy with capstan heads, chromium plated screwed down high, pressure with provn of overhead shower on upper side connecting legs and wall flanges high quality fancy type complete all as specified and as directed by Engineer in Charge
S&F in repair stainless steel towel ring square with round flange complete all as specified and as directed by Engineer in Charge
S&F in repair soap dish with screws complete all as specified and as directed by Engineer in Charge
S&F in repair waste coupling 32mm size half threaded with 80 mm height suitable for wash basins complete all as specified and as directed by Engineer in Charge
S & F in repair pillar Taps, chromium plated,15 mm dia quarter turn fixed to pipe complete all as specified and as directed by Engineer in Charge
S&F in repairs bib tap long body with flange chromium plated screwed for 15mm bore complete all as specified and as directed by Engineer in Charge
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915x460 mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed by Engineer in Charge
S&F in repair concealed stop cock with 15mm flange with seal(comatible with ALD-089)valves cast copper alloy chromium plated with long shank and cup (concealed type) fancy type screwed down high pressure screwed both ends for pipe complete all as specified and as directed by Engineer in Charge
S&F in repair CP Toilet paper holder fancy type high quality complete all as specified and as directed by Engineer in Charge
S&F in repair Corner glass shelf high quality of 300mm (With ABS Brackets) 300x600 complete all as specified and as directed by Engineer in Charge
S & F in repair PVC Body Cabinet Box Mirror of size 350mm X 450mm X 100mm in PTMT alloy of approved design and pattern complete all as specified and as directed by Engineer in Charge
S&F in repair towel Rail CP Brass complete all as specified and as directed by Engineer in Charge
Dismantling water tanks exc 500 Ltrs capacity & n exc 1000 Ltrs and removing from site complete all as specified and as directed by Engineer in Charge
Disconnecting existing tanks,Exc 500 & n.exc 1000Ltrs, setting aside (or lowering if required) for repairs,cleaning ,etc.and hoisting if required reconnecting and refixing in position and cleaning and removing scale and dirt,etc,from tanks and from mouths of circulating pipes etc complete all as specified and as directed by Engineer in Charge
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 ltrs capacity hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed by Engineer in Charge
S&F CPVC ball valve of 25 mm dia complete all as specified and as directed by Engineer in Charge
Demolition and breaking out drain pipes of dia up to 150 mm including necessary bend ,T and other accssories etc complete all as specified and as directed by Engineer in Charge
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls incuding necessary clamps and fittings etc to fixing on walls complete all as specified and as directed by Engineer in Charge
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer in Charge
S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid intrenches or in floors incuding necessary clamps complete all as specified and as directed by Engineer in Charge
S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls incuding necessary clamps etc complete all as specified and as directed by Engineer in Charge
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed by Engineer in Charge
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and as directed by Engineer in Charge
S & F 110 mm bore PVC (SWR) Vent Cowl complete all as specified and as directed by Engineer in Charge
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed by Engineer in Charge
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and as directed by Engineer in Charge
S & F 110 mm bore PVC (SWR) bends with access door complete all as specified and as directed by Engineer in Charge
S & F 75 mm bore PVC (SWR) branch piece,double(double Y) equal or unequal complete all as specified and as directed by Engineer in Charge
S&F PVC SWR reducers one end 110 another reduced 75mm complete all as specified and as directed by Engineer in Charge
S&F in repair PVC (SWR) floor trap diameter of out let 110 mm ,plain with grating including jointing with solvent cement fixed in cement concrete complete all as specified and as directed by Engineer in Charge,(cement concrete shall be measured and paid seperately.
Dismantling of wall and ceiling boards (fiber, pulp , insulation etc)or insulation boards /slabs /blankets any thickness including cover fillets, grid work any description and any position complete all as specified and as directed by Engineer in Charge
S & F False Ceiling Frame Work using Aluminium anodised snap grid of size 605 x 605 mm size of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 605 x 605mm suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab roof truss fixed with suitable size MS hook and fastening bolts etc fixed in ceiling with clips to aluminium snap grid for fixing 6mm thick non Asbestos cement building boards fixed to ceiling frame work complete all as specified and as directed by Engineer in Charge Note: Ceiling board shall be measured and paid seperately.
S &F 4 mm thick Non asbestos cement building boards of suitable size to fixed in aluminium /GI /wooden framework etc in ceiling with necessary screws complete all as specified and as directed by Engineer in Charge
Taking down chowkats or frames not exceeding 1.5 Sqm (with shutters & grill (if fixed) without taking off shutters from the frame) complete all as specified and as directed by Engineer in Charge
Taking down chowkats or frames exc 1.5 Sqm and not exceeding 4 Sqm (with shutters and grill (if fixed) without taking off shutters from the frame) complete all as specified and as directed by Engineer in Charge
S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed by Engineer in Charge
S&F Factory made solid panel PVC door shutter 30 mm thick consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stilesand plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
M&L for Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators and partition with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engineer in Charge
S&F Anodised aluminium powder coating of any colour (Thickness or powder coating not less than 50 micron) door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and as directed by Engineer in Charge
S & F Anodised aluminium powder coating of any colour (Thickness or powder coating not less than 50 micron).window and ventilator shutters (sliding type), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed by Engineer in Charge
S & F only 4 mm Plain sheet glass ordinary quality, in square not exc 0.5 sqm each complete all as specified and as directed by Engineer in Charge
S & F only 4 mm Plain sheet glass ordinary quality, in square exc 0.5 sqm each complete all as specified and as directed by Engineer in Charge
S&F in repair 12mm thick Prelaminated particle board, interior grade, prelaminated on both sides with decorative choice lamination fixed as in panels of Aluminium door shutters, partition etccomplete all as specified and as directed by Engineer in Charge
S&F in repair aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed by Engineer in Charge
S&F in repair butt hinges of stainless steel 100 mm long ISI marked fixed with brass screws complete all as specified and as directed by Engineer in Charge
S & F in repair 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engineer in Charge
M&L in repair 125mm butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and as directed by Engineer in Charge
S&F in repair 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed by Engineer in Charge
S & F in repair 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer in Charge
S & F in repair door stopper of size 150 mm of aluminium alloy body double leg with rubber bush complete all as specified and as directed by Engineer in Charge
S&F in repair stainless steel curtain rod of 20 mm dia fixed with necessary clamps and fixed on wall including necessary drilling and fixing complete all as specified and as directed by Engineer in Charge Note: Clamps shall be measured and paid separately
Supply only stainless steel clamps and doom for fixing of 20 mmdia curtain rails complete all as specified and as directed by Engineer in Charge
S&F in repairs 30mm width continuous (piano) hinges mild steel ,bright finish or electro galvanised complete all as specified and as directed by Engineer in Charge
S&F in repairs using MDF (medium density fiber) board 18/19 mm;fixed with necessary fittings , screws to timber frames as in cup board shutters,shelves and partition etc at any position complete including necessary beading complete all as specified and as directed by Engineer in Charge
S&F 100mm long aluminium anodised hasp and staples,safety type,with hinges including bolt to hingeplate and and fixed with screws complete all as specified and as directed by Engineer in Charge
S&F Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between61 to 80 kg and fixed complete all as specified and as directed by Engineer in Charge
Demolition of stone slabs and tiles of any description or thicness in floors laid bedded pointed in any cement mortor in any position not otherwise specifically provided for complete all as specified and as directed by Engineer in Charge
Excavation in post holes(or similar holes) each n. exc 0.5 Cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc exc 25 cm watering and removing surplus soil to a distance n exc 50 m and making good surface as in soft/loose soil complete all as specified and as directed by Engineer in Charge
M&L for cement concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by Engineer in Charge
S&F Mild Steel work in Tubular Trusses, Posts etc including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS - 1161-1979, Grade St - 240, Medium Grade of any dia complete all as specified and as directed by Engineer in Charge
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-410 W (Grade E-250) quality A complete all as specified and as directed by Engineer in Charge
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as manufacturers instruction complete all as specified and as directed by Engineer in Charge
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing complete all as specified and as directed by Engineer in Charge
S&F Aluminium flat 40 X 6mm size as wind tie fixed with 50mm/75mm aluminium self staging screws complete all as specified and as directed by Engineer in Charge
M&L for applying two coats of synthetic enamel paint over a coat of red oxide, zinc primer including preparation of new steel/iron surface of any description over 10 cm in width or girth complete all as specified and as directed by Engineer in Charge
M&L for hard core of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled / rammed to a true surface complete all as specified and as directed by Engineer in Charge
M&L for 100mm thick PCC (1:3:6) type C-2 (40 mm graded stone aggregate) as in sub-base complete all as specified and as directed by Engineer in Charge
M & L for heavy duty vitrified chequered cement concrete tiles 30cm x 30cm x 10 mm thick, set, jointed and pointed in near cement slurry in floors With grey cement and pigments and including screed bed 15mm thick CM 1:4 complete all as specified and as directed by Engineer in Charge
M&L for 100mm thick PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floor/hard-standing finished even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge
M&L for taking down carefully existing aluminium point wiring (light, fan , socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc to be measured separately)unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good disturbed surfaces of walls, floors etccomplete all as specified and as directed by Engineer in Charge
M&L for taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and as directed by Engineer in Charge
M&L for taking down unserviceable main switches ,DBs and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and as directed by Engineer in Charge
M&L for point wiring with two runs of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit medium duty/PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge.( In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.
One light point controlled by one one way switch complete all as specified and as directed by Engineer in Charge
One ceiling fan/exhaust fan point controlled by one switch complete all as specified and as directed by Engineer in Charge
One 3 pin socket outlet 5 Amps independent complete all as specified and as directed by Engineer in Charge
One 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed by Engineer in Charge
One bell/ buzzer point controlled by one push button independent complete all as specified and as directed by Engineer in Charge
All as per item No 128.00 above but cable with 2.5 sqmm for socket outlet 15 amps independent complete all as specified and as directed by Engineer in Charge
S&F Submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable four runs of 10 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall or fixed on wall/ceiling and one run of 10 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed. Note : (i) Four runs of single core cable with one run of earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Cutting chasis in wall/floor beam to be concealed conduit and make good the surface is deemed to be included in the above rates.
S&F Submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two runs of 6 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 20mm dia with conduit accessories and concealed in wall or fixed on wall/ceiling and one run of 6 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed.
All as per item No 136.00 above but with 4.0 sqmm cable complete all as specified and as directed by Engineer in Charge
All as per item No 136.00 above but with 1.5 sqmm cable complete all as specified and as directed by Engineer in Charge Notes for item Nos.136.00 to 138.00 : (i) Two runs of single core cable with one run of earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Cutting chasis in wall/floor beam to be concealed conduit and make good the surface is deemed to be included in the above rates.
S&F in repair switch piano, flush type single pole, one way 5 Amps complete all as specified and as directed by Engineer in Charge
S&F in repair switch socket combination 2 in 1, 5 Amps flush type complete all as specified and as directed by Engineer in Charge
S&F in repair switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and as directed by Engineer in Charge
S&F in repair bell push, flush type 5 amps complete all as specified and as directed by Engineer in Charge
S&F in repair buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and as directed by Engineer in Charge
S&F in repair ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed by Engineer in Charge
S&F in repair LED lights fitting 20W, 2200lm, CDL, surge protection of 2 KV, 4 feet 220V, AC, aluminium extrusion with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer in Charge
S&F in repair LED 18W inverter batten type fitting 4 feet long aluminium extruded housing, charging time 10-12 Hrs with 04 Hrs backup,IP-20 ,rated voltage 230 V, 50 hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 1200lm, CDL, 220 V AC, aluminium extrusion with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer in Charge
S&F in repair LED luminaire 600 mm x 600 mm 40 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer in Charge
S&F in repair LED bldg security light fitting 25 watt, 230V AC, 2500lm, outdoor type, pressure die cast housing with epoxy powder coated, dark graphite grey colour finish, poly carbonate cover with individual LED lenses with IP 65 protection with 10 KV SPD complete all as specified and as directed by Engineer in Charge
S&F in repair LED oval shape single head wall mount light 20 Watt, CDL, IP-20 complete all as specified and as directed by Engineer in Charge Note for item No 145.00 to 150.00 : LM 79 & LM 80 certificate to be submitted.
S&F in repair exhaust fan made of steel body complete with louvers, voltage 230V, 50 HZ, RPM 900, Copper winding of sweep 300mm and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan including taking down old unserviceable exhaust fan and deposited to MES store yard complete all as specified and as directed by Engineer in Charge
S&F in repair ceiling fan 1200mm sweep with blades, suitable BLDC electronic regulator/remote as per OEM design, down rods and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, 5 star rated, equipped with brushless direct current motor (BLDC) including provision of cable from ceiling rose/connector to fan including taking down old unserviceable exhaust fan and deposited to MES store yard complete all as specified and as directed by Engineer in Charge
S&F in repair electric water heater capacity 25 litre, storage type steel body with copper inner tank and heating element upto 2 KW, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece including stainless steel hot & cold water pipe including taking down old unserviceable geyser and deposited to MES store yard complete all as specified and as directed by Engineer in Charge
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp, 'C' curve, 10 KA complete all as specified and as directed by Engineer in Charge
S&F MCCB DB VTPN 4 way IP-54, IK-09 made of sheet steel phos phatised, powder painted with copper bus bar 250A, neutral link, earth bar and Din rail 415 Volts with double door, suitable for MCCB 4 Pole 63 Amps as incomer and MCB Single Pole as outgoing complete all as specified and as directed by Engineer in Charge
S&F MCB DB SPN 8 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 200 amps rated busbar including fixing of cable with appropriate size of lugs complete all as specified and as directed by Engineer in Charge Note for item No 155.00 &156.00: (i) MCCB and MCB shall be measured and paid separately. (ii) Cost for concealed the DBs on wall including making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate.
S&F MCCB 4 pole, 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and as directed by Engineer in Charge
S&F MCB SPN 40 to 63 Amps ,10 KA, C Curve, 230 Volts ,50 HZ complete all as specified and as directed by Engineer in Charge
S&F MCB SP 6-32 Amps ,10 KA, C Curve, 230 Volts ,50 HZ complete all as specified and as directed by Engineer in Charge
M&L for earthing to switch gear/MCB DB with GI earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of galvanised iron nuts, bolts and washer, earth lead connected to eqpt as directed, earth plate surrounded with adequate quantity of charcoal dust and common salt to a packed thickness alternate layer of 15 cm all around the plate including necessary earth work, PCC chamber and reinforced PCC cover made by PCC 1:3:6 type C-1 as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with 6mm dia MS bar at 150mm c/c both ways with 10mm dia MS round bar as handle, 20mm bore GI pipe medium grade for watering and 15mm dia GI pipe light grade for protection of earth lead upto 7.5 mtr with funnel, wire mesh etc with and including testing complete all as specified and as shown in electrical plate No 3 of MES sch Part I. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth wire upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing.
Usha Builders
Nirman Construction Company
DEEPAK AGENCIES
M/s K Moorthi
M/s Ramesh Lal
M/s Saina Enterprises
MAJUMDAR FURNITURE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .