Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.3 Cr
EMD Value
₹3.0 L
Closing Date
1 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone, PIN-900386, C/O 56 APO
PROVN OF SECURITY WALL, SENTRY POST ALONGWITH ALLIED INFRASTRUCTURE UNDER GE 881 EWS
2025_MES_726213_1
87969-A/E8
Open Tender
Civil Works
Lump-sum
455 days
Poonch
As per NIT
8 documents required · 8 mandatory
₹2,000
GE 881 EWS
₹3.0 L
Yes
HQ Chief Engineer Udhampur Zone
14 Aug 2025
14 Aug 2025
3 Dec 2025
14 Aug 2025
1 Dec 2025
7 Nov 2025
15 Aug 2025 - 10 Sept 2025
22 Aug 2025
Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Construction of Block of Elevated Guard Post including steel ladder complete all as shown on drawings and as specified.
Total Amount of Sch 'A' Part - II (Site Clearance & Development)
Total Amount of Sch 'A' Part - III (Internal Electric Supply Work)
Total Amount of Sch 'A' Part - IV (Protective Work)
Total Amount of Sch 'A' Part -V (Road, Path and Hard Standing Work)
Total Amount of Sch 'A' Part - VI (External Electric Supply Work)
Total Amount of Sch 'A' Part - VII (Security Wall, Fencing and Gate Work)
Sch 'A' Part - VIII (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Prime Mover : Prime mover suitable for driving alternator 25 KVA Capacity having the suitable BHP at 1500 RPM for rated output for alternator in accordance with latest BS/IS Specification with electric starting device with all standard fittings and suitable capacity of lead acid maintenance free battery of 12 Volts as per manufracturer -01 No with Battery and Charger Engine over speed safety mechanism shall be incorporated. The engine shall be equipped with standard fittings as per manufacture's recommendations.
Engine Control Panel : (a) All relevant parameters shall be conventionally displayed on complete panel thereby providing easy monitoring of lubricant oil, pressure, Coolant temperature, battery charging, ammeter, RPM, hour meter and starting switch etc. (b) AMF Panel with Bye Pass arrangement for Main and DG, both supply, internal wiring and power contactors suitable for 25 KVA generator set, all as per manufacturer's recommendation. Bye Pass arrangement Main & DG set Supply along with all the parameters and accessories as per manufacturer recommendation and CPRI Approved & as per relevant IS. Fuel Tank : Fuel Tank of 12 hours capacity will be installed as per the manufacturer's requirement including all necessary pipe connections from fuel tank to engine and over flow from engine to tank.
Engine Alternator Engine Alternator of capacity 25 KVA output 3 Phase 50 HZ 415 Volts 4 wire AC supply 0.8 Power Factor at 1500 RPM self regulated self excised screen protected and drip type, insulation class 'H' continously rated brush less type conforming to relevant BS/ IS code as per current manufacturing shedule of standard manufacturer. Engine Alternator shall be mounted on specially designed base plate of rigid welded constructions with anti vibraton pads. The DG Set shall be placed on foundation including necessary civil works as per the manufacturer's recommendations/site requirement. The output of alternator not less than 25 KVA in all adverse conditiones, as the DG set to be installed at HAA 950 m above MSL. Note:- (a) The unit rate shall deemed to include the cost of Diesel and lubrication required for testing and commissioning of DG Set as per department procedure and shall be arranged by contractor. (b) Extenssion of exhaust pipe for DG set along with standerd accessories like flange, nut bolts , asbestous rope etc. shall be provided by the contractor and the cost of the same shall be included in the unit rate quoted by contractor. (c) Cost of PCC foundation and necessary civil works as per the manufacturer's recommendations/site requirement shall be incuded in the unit rate quoted by the contractor.
PVC insulated PVC sheathed multi core flexible cable copper conductor 1100 volts grade conforming to IS-694/2010 of size 1.5 Sqmm 3 core including 25mm PVC conduit (heavy duty) from junction box to light fitting connecting up complete all as specified and directed.
DWC HDPE pipe for protection of power cable (orage in colour) of size 50 mm dia complete with fittings and including cutting, jointing and clamping complete all as specified and directed .
Punched tape concertina coil as per latest IS 6745-1972 with galvanised coating and punched type material as per IS deep drawn quality with galvanised coating having medium barbs fixed in position and secured to fence posts/straining Y- arm stretched to a length so as to achieve 600mm dia as in fencing including fixing with special galvanised fasteners such as J clips, C clips, U clips fixed at any height of security fence including necessary scaffolding complete all as directed. Size of Coil: 600mm dia and 2.5mm core wire thick. Type of strip: Heavy galvanised conforming to IS 1730 (1989). Type of core wire: Heavy galvanised conforming to IS 280-2006. Zinc coating to strip : 200GSM/Sqmm Zinc coating to line wire: 275 GSM/Sqmm (IS 6745- 1972 Reprint 2006) Tensile strength of wire: 1400-1500 N/Sqmm. Weight: 13.50 Kg/per coil (± 5% tolerance). Blade: 22mm Barb, profile: Medium blade (MBBT). Distance between barb: 35mm, Stretchable length of each coil: 10m. Type of clip: Hard and galvanised steel.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDER_compressed.pdf
Tender Documents • 0.97 MB
DRG1_compressed.pdf
Additional Documents • 2.89 MB
DRG2_compressed.pdf
Additional Documents • 0.85 MB
DRG3_compressed.pdf
Additional Documents • 0.59 MB
BOQ_812919.xls
BOQ • 2.46 MB
CorrNo06.pdf
PDF • 0.32 MB
CorrNo05.pdf
PDF • 0.32 MB
CorrNo04.pdf
PDF • 0.32 MB
CorrNo03.pdf
PDF • 0.32 MB
CorrNo02.pdf
PDF • 0.32 MB
CorrNo01.pdf
PDF • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .