Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC Bid awarded to lowest bidder | |
| 2 | L2₹5.3 L+₹44,650 (9.16%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹5.6 L+₹68,845 (14.1%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | Rejected-Technical 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | - | Rejected-Technical Not Beiing Eligile |
| Sl No | Description | Qty | Unit | ANAND REFRIGERATION L1 | JM Engineering L3 | PLATINUM CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for complete servicing after pumping down Indoor/outdoor units of window/split AC 1.5/2 TR capacity of any make from its existing position/location, shifting the same, by by cleaning condenser/ Evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, cleaning the air filter, connecting up all connections and testing after gas charging if required all as directed for Split type Air Conditioner up to 1.0 Ton. Note : (i)Replacement of spare parts will be measured and paid separately under relevant items of BOQ.(ii) In case of shutdown of AC,Complaints shall be attended by Mechanic with in four hrs .(iii) If Contractors fails to attend the complaints within 4 hrs ,shall be imposed panelty 100 Rs per 4 hrs . | 53 | Each Job | 750 ₹39,750 | 600 ₹31,800 Lowest | 1,000 ₹53,000 |
| 2.00 | Supply and fix Capacitor 40/50 mfd all as specified and directed . | 45 | Each | 550 ₹24,750 | 500 ₹22,500 Lowest | 500 ₹22,500 Lowest |
| 3.00 | Supply and fix Air Filter all as specified and directed . | 42 | Each | 275 ₹11,550 | 350 ₹14,700 | 200 ₹8,400 Lowest |
| 4.00 | Supply and fix Wiring kit complete set all as specified and dIrected . | 20 | Each | 700 ₹14,000 Lowest | 1,800 ₹36,000 | 1,000 ₹20,000 |
| 5.00 | Supplying and Fixing in repairs Copper tube 1/2 " with adapter/flair nuts ,insulation foam all as specified and directed . | 47 | RM | 650 ₹30,550 | 700 ₹32,900 | 600 ₹28,200 Lowest |
| 6.00 | Supplying and Fixing in repairs Copper tube 3/4 " with adapter/flair nuts,insulation foam all as specified and directed . | 47 | RM | 700 ₹32,900 | 750 ₹35,250 | 650 ₹30,550 Lowest |
| 7.00 | Supplying and Fixing in repairs PC unit/electronic circuit plate of appropriate make/model of 1.5/2 TR Acs all as specified and directed . | 15 | Each | 2,800 ₹42,000 Lowest | 3,200 ₹48,000 | 3,200 ₹48,000 |
| 8.00 | Supply and fix Remote control with batteries of appropriate make/model for Split type AC all as specified and directed . | 10 | Each | 950 ₹9,500 | 800 ₹8,000 Lowest | 1,000 ₹10,000 |
| 9.00 | M&L for gas charging charging withf refrigerant gas F-22 / R-22 /R-32 / R-134A same as existing gas to the split type Air conditioner, after vaccumising the complete system & pressure test with nitrogen to ensure complete system leak proof, testing of air conditioners, functioning & cooling effect as directed by Engineer in Charge | 35 | Each Job | 2,500 ₹87,500 Lowest | 3,500 ₹1,22,500 | 2,800 ₹98,000 |
| 10.00 | Supply and fixing in repair copper condensor coil unit suitable for AC 1. 5 TR | 5 | Each Job | 3,800 ₹19,000 Lowest | 4,000 ₹20,000 | 4,000 ₹20,000 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
17 Jul 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Shubham Yadav,AEE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
MAINTENANCE AND REPAIR TO SUMMER AND COOLING APPLIANCES AT NO 2AFSB MYSORE UNDER AGE I AF CHIMNEY HILLS
2025_MES_713858_1
8821/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
2AFSB MYSORE
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
AGE I (AF) Chimney Hills, Bangalore
₹10,000
Yes
24 Sept 2025
12 Jun 2025
19 Jul 2025
12 Jun 2025
17 Jul 2025
4 Jul 2025
12 Jun 2025 - 26 Jun 2025
Amount
M&L for complete servicing after pumping down Indoor/outdoor units of window/split AC 1.5/2 TR capacity of any make from its existing position/location, shifting the same, by by cleaning condenser/ Evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, cleaning the air filter, connecting up all connections and testing after gas charging if required all as directed for Split type Air Conditioner up to 1.0 Ton. Note : (i)Replacement of spare parts will be measured and paid separately under relevant items of BOQ.(ii) In case of shutdown of AC,Complaints shall be attended by Mechanic with in four hrs .(iii) If Contractors fails to attend the complaints within 4 hrs ,shall be imposed panelty 100 Rs per 4 hrs .
Supply and fix Capacitor 40/50 mfd all as specified and directed .
Supply and fix Air Filter all as specified and directed .
Supply and fix Wiring kit complete set all as specified and dIrected .
Supplying and Fixing in repairs Copper tube 1/2 " with adapter/flair nuts ,insulation foam all as specified and directed .
Supplying and Fixing in repairs Copper tube 3/4 " with adapter/flair nuts,insulation foam all as specified and directed .
Supplying and Fixing in repairs PC unit/electronic circuit plate of appropriate make/model of 1.5/2 TR Acs all as specified and directed .
Supply and fix Remote control with batteries of appropriate make/model for Split type AC all as specified and directed .
M&L for gas charging charging withf refrigerant gas F-22 / R-22 /R-32 / R-134A same as existing gas to the split type Air conditioner, after vaccumising the complete system & pressure test with nitrogen to ensure complete system leak proof, testing of air conditioners, functioning & cooling effect as directed by Engineer in Charge
Supply and fixing in repair copper condensor coil unit suitable for AC 1. 5 TR
M&L for gas charging with refrigerant gas F-22 / R-22 /R-32 / R-134A ( same as existing gas) Refrigerator, water cooler and deep freezer of capacity 200L to300L after vaccumising the complete system & pressure test with nitrogen to ensure complete system leak proof, testing of for proper functioning & cooling effectbas directed byEngineer in Charge
M& L for Removing the existing defective / unserviceable hermetically sealed compressor unit from Acs and replacement with the same Make factory sealed compressor unit, connecting refrigeration system after thorough flushing out the system with dry nitrogen, leak testing with nitrogen, vaccumising including neccessery brazing and welding arresting leakages and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit all as directed for Split ACs of appropiate make / model for 1.5 TR AC. Notes :– (i) Factory sealed compressor unit shall be of existing capacity and make. (ii) Gas Charging shall be measured and paid separately under relevant item of this schedule.
Supply and Fix in repair condensor fan motor suitable for out door unit of split type AC 1.5 TR
Replacement of Cable PVC insulated and sheathed 3 core 4 sqmm by removing burnt cable from Acs
Replacement of rusted outdoor mounting stand set with new one for outdoor unit of Split type AC including nuts, bolts & wahers etc.
Removing the outlived Insulating teflon sheets from the existing copper tubes of Split type Air conditioners, S&F the same on copper tubes from inner unit to outer unit complete all as specified and directed.
Servicing, maintenance and repairs to Refrigerator /wate rcooler/ Deep Freezer of capacity up to 286/310 Ltrs of any make and model including periodical cleaning to condenser coil and compresser, Replacement of defective spares will be measured and paid separately under relevant items as under complete all as specified and directed .
Replacements Starting Relay for Refrigerator/ water cooler all as specified and directed .
Supply and fix Ice cube Tray plastic set of two all as specified and directed .
Hard plastic Stand suitable for Refrigerator of any make / model up to 310 ltr.
Removing the existing defective / short circuited hermetically sealed compressor unit from the Refrigerator, Replacement of the same with company rewound sealed compressor unit of appropriate make / model for Refrigerator capacity upto 310 ltrs.
Supply and Fixing in repairs voltage stabilizer 5/4 KVA capacity Suitable for AC 1.5 TR
Supply and Fixing in repairs voltage stabilizer 3/2 KVA capacity Suitable for Refrigerator/deeepfreezer
Supply and fix sheet metal enclosures with socket plug top of capacity alongwith 20 Amps MCB SP all as specified and directed by engineer in charge .
Supply and fixing in replacement of plug top 15 Amps 3 pins connection complete all as specified and as directed by Engineer-in- Charge. ( MAKE : ANCHOR/KINJAL/KAY)
PLATINUM CONSTRUCTIONS (BID ID -3361722)
JM Engineering (BID ID -3360361)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .