Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹5.9 Cr
EMD Value
₹11.7 L
Closing Date
2 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
+ Capital Works)
Above/Below/Par
SIG WORKS
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less, where: V= Advertised value of the tenderin crores of Rupees N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractualturnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the auditedbalance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourthprevious year shall be considered for calculating average annualcontractual turnover. The tenderers shall submit requisite information asper Annexure VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from CharteredAccountant duly supported by Audited Balance Sheet As per Clause No. 10.2 of Tender Form (second Sheet) of Annex. I of Part-I of GCC-2022,with up to date correction slip.
The tenderer must have successfully completed or substantially completed any of the following categories of work(s) during last 07(seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than theamount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of theadvertised value of the tender, or (iii) One similar work each costing not less than the amount equal to 60% of the advertised value of the tenderWork experience certificate from private individual shall not be considered. However, in addition to work experience certificates issuedby any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore andabove in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay StockExchange,incorporated/registered at least 5 years prior to the date of closing of tender,shall also be considered provided the work experiencecertificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits workexperience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy ofwork order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all paymentsreceived and copy of final/last bill paid by company in support of above work experience certificate. As per Clause No. 10.1 of Tender Formsecond Sheet of Annex. I of Part-I of GCC 2022, with up-to-date correction slip.
Definition of similar work: "Any Signalling Work "
62 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer should note that tender will be dealt as per GCC 2022 and latest amendments to it.
Rates in the schedule items of work are inclusive of all taxes as per clause 37 of GCC-2022
Wherever there is any ambiguity in SOR Item Description, that particular item description in latest RDSO Specification to be considered as FINAL.
Telecom Circular No. 09/2023 (copy attached) shall be religiously followed for undertaking digging work in the vicinity of Signalling, Electrical and Telecommunication Cables. ZonalRailways issued local instructions/JPO for protection of cables while undertaking works in the vicinity of Railway Tracks in line with Telecom Circular 09/2023.
Signalling work in Connection with Provision of TWS-290 sets in Passenger running loop lines over Rewari-Madar Section of Jaipur Division.
SNT-JP-28-2026-27~NWR
SNT-JP-28-2026-27
Open
Works - General
24 Months
Jaipur, Rajasthan
₹0
₹11.7 L
8 Oct 2026
8 Oct 2026
19 Oct 2026
89 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 5,49,18,268.45 | ||
| — | 25.00 | — | — | ||
| Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABDEG".Inspection: - RDSOInspection charges: - Borne by RailwaysPayment Terms: - 100% after supply. | — | — | — | 1,71,542.5 | |
| — | 25.00 | — | — | ||
| Contactor Unit (QBCA1 Type), 24 V DC, 2HF/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS:S-34 & S- 23 or latest. The interlocking code for this unit shall be "BCEJK".Inspection: - RDSOInspection charges: - Borne by RailwaysPayment Terms: - 100% after supply. | — | — | — | 2,13,019.5 | |
| — | 25.00 | — | — | ||
| Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDE".Inspection: - RDSOInspection charges: - Borne by RailwaysPayment Terms: - 100% after supply. | — | — | — | 1,18,651.75 | |
| — | 25.00 | — | — | ||
| Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDF".Inspection: - RDSOInspection charges: - Borne by RailwaysPayment Terms: - 100% after supply. | — | — | — | 1,14,012.75 | |
| — | 40.00 | — | — | ||
| Q-Series Twin Neutral Line Relay (QNN1 Type), 6F/2B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ACDEK".Inspection: - RDSOInspection charges: - Borne by RailwaysPayment Terms: - 100% after supply. | — | — | — | 2,39,994 | |
| — | 2000.00 | — | — | ||
| Supply of ARA Terminal Block (M-6) made of PBT/Poly Carbonate as per RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest and RDSO Drg. No. SA-23741A (Alt. 4) or latest.Inspection: RDSO.Inspection Charges: Borne by Railways.Payment Terms: 100% on supply. | — | — | — | 2,10,400 | |
| — | 2000.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after execution | — | — | — | 20,360 | |
| — | 290.00 | — | — | ||
| Supply of Electric Point Machine, Non Trailable, Internal Locking, 220Mm Throw with IP 67 Motor, Minimum AC Immunity 400V AC With Tools and Complete Accessories Including Complete Ground Connection and all Insulation, Crank Handle and Along with Clamp Point Lock 60Kg, TWS As Per Drg.No. RDSO/S/11000 As Per RDSO Spn. IRS:S-24/2002 With Amd.01 Or Latest. IRS Type.Inspection: RDSOInspection Charges: Borne by RailwaysPayment Terms: 100% after Supply. | — | — | — | 3,49,53,262.1 | |
| — | 290.00 | — | — | ||
| Fixing of Electrical high thrust (220mm) point machine on the extended sleepers at thick web point as per standard railway practice as per RDSO Drg. No. S 3454 Alt 'A' or latest as per section of rails used. Item included fixing of switch extension bracket, fixing of switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting of the point machine with crank handle. The item also includes (i) Complete material for installation of point machine and fixing of ground connection/ switches extension bracket like point insulator materials, S pipe, wiring materials various fixing nuts & bolts including casting nuts, spring washers, etc. (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate. (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes/ location box /cable hut as per extent practice on NWR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine.Note: Electrical Point Machine and M-6/ Screw less terminals will be supplied by Railways /covered in Schedule separately.Inspection: ConsigneeInspection charges: Borne by RailwaysPayment terms: 90% after Installation & 10% after commissioning. | — | — | — | 57,16,645.3 | |
| — | 100.00 | — | — | ||
| Supply of Track Lead Junction Box (TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows:(a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc.(b) Each TLJB shall have two Bakelite terminal block fitted horizontally: each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB, nickel chrome plated brass links (two nos.0f adequate strength for vertical linking of the terminals to be supplied.(c) HDPE pipe of size 32/35mm, 380 mm long alongwith two nuts for fixing on the TLJB hole.(d) The FRP stump for mounting the TLJB to be made of one-meter long 30mm X30mmX 4mm angle (2 nos.) and 300mm long 30mm X30mmX 4mm angle (1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509.Inspection: (i) RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board.Inspection Charges: (i)Borne by Railways (ii) NonePayment Terms: 100% on Supply | — | — | — | 2,14,030 | |
| — | 100.00 | — | — | ||
| Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (FRP stumps) with contractor's fixing material. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after execution. | — | — | — | 1,58,337 | |
| — | 1000.00 | — | — | ||
| Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after Supply. | — | — | — | 6,850 | |
| — | 200.00 | — | — | ||
| Supply of GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding. Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after Supply. | — | — | — | 15,888 | |
| — | 20.00 | — | — | ||
| Supply of Apparatus Case Single (Large) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500.Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys.Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board.(ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board.Inspection Charges:(i) Borne by Railways (ii) NonePayment Terms: 100% after Supply. | — | — | — | 3,59,738.8 | |
| — | 20.00 | — | — | ||
| Installation of Apparatus Cases Single (Large) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. | — | — | — | 25,010.8 | |
| — | 10.00 | — | — | ||
| Supply of Apparatus Case half (Medium) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11507.Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board.(ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board.Inspection Charges:(i) Borne by Railways (ii) NonePayment Terms: 100% after Supply. | — | — | — | 1,13,603.2 | |
| — | 10.00 | — | — | ||
| Installation of Apparatus Cases Half (Medium) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of Location lamp holder, switch and lamp etc.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. | — | — | — | 7,615.6 | |
| — | 20.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. Single (Large) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | — | — | — | 1,65,816.2 | |
| — | 10.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. Half (Medium) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | — | — | — | 63,294 | |
| — | 15.00 | — | — | ||
| Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 12 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied.Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee Inspection Charges:(i) Borne by Railways (ii) NonePayment Terms: 100% after Supply. | — | — | — | 87,647.25 | |
| — | 20.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. Single Case (Large Case) | — | — | — | 56,431.8 | |
| — | 10.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. Half Case (Medium Case) | — | — | — | 8,231.9 | |
| — | 2000.00 | — | — | ||
| Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. (Supply of all above terminals have been covered separately in Chapter 4 of SOR)Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. | — | — | — | 30,140 | |
| — | 1500.00 | — | — | ||
| Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine) or by Closed trench Method. The bore shall be upto 200 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different Dia DWC-HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note: - Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution | — | — | — | 21,71,655 | |
| — | 20000.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. (cum is Cubic Meter)Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution | — | — | — | 66,02,000 | |
| — | 75000.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution | — | — | — | 8,21,250 | |
| — | 75000.00 | — | — | ||
| Supplying and placing of one layer of standard size of 'B' grade quality bricks of the local make spreading on cables laid. (minimum size of brick 200mm X 100mm X 70mm)Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Installation. Length wise (up to 2 cables). | — | — | — | 13,35,750 | |
| — | 20.00 | — | — | ||
| Supply of hand operated track drilling machine for bonding hole.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after supply. | — | — | — | 1,93,791 | |
| — | 25.00 | — | — | ||
| Supply of Ground connection insulations for thick web switch layout facing point (BG) for 52kg/60kg rail fitted with high thrust point machine comprising of the following:1. Bush as per DRG. No. S 3463-1no.and Washer as per DRG. No.S8640-2no.for drive (throw) rod2. Bush as per DRG. No. S 23199-1no and Washer as per DRG. No. S 8640-2no for short detector rod.3. Bush as per DRG. No. S 23199-1no and Washer as per DRG. No. S 8640-2no for long detector rod.4. Bush as per DRG. No. S 22179-1no and Washer as per DRG. No. S 8640-2no for short lock rod.5. Bush as per DRG. No. S 22179-1no and Washer as per DRG. No. S 8640-2no for long lock rod.6. Bush 'B' as per DRG. No. S 8912 for LH lock slide-1 no.7. Bush 'B' as per DRG. No. S 8912 for LH lock arm-2 no.8. Bush 'B' as per DRG. No. S 8912 for RH lock arm -2 no.9. Bush 'B' as per DRG. No. S 8912 for RH lock slide-1no.10. Bush as per DRG. No. S 23199 -4no and washer as per DRG. No. S 8640-4no for LH lock slide.11. Insulating Plate LH as per DRG. No. S 3404 RDSO/S 3593-1no.12. Insulating Plate RH as per DRG. No. S 3404 RDSO/S 3592-1no.13. Bush as per DRG. No. S 23199-4no and washer as per DRG. No. S 8640-4no for RH lock slide.Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board.Inspection Charges: (i)Borne by Railways (ii) NonePayment Terms: 100% after Supply | — | — | — | 26,850 | |
| — | 5.00 | — | — | ||
| Supply of complete set of ground connections for high thrust 220 mm stroke point machine along with insulation as per Drg. No RDSO/S3454 Alt.B dt 25-01-2023 or latest along with insulation.Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board.Inspection Charges: (i)Borne by Railways (ii) NonePayment Terms: 100% on Supply | — | — | — | 2,92,050 | |
| — | 600.00 | Man-Days | — | ||
| Providing Services of helping hand man power to carry out miscellaneous/sundry works in the office/field between 08.00 hrs and 20.00 hrs of the day and accompanying Railway staff with all expenses of transportation, accommodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fess, duties, with contractors tools and plants, materials, consumables, labour, crew, machineries with all lead and lift etc., complete as per special conditions, specification, regulation and as directed by Railway Engineer-in-charge. | — | — | — | 4,04,400 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocumentofTenderNoSNT-JP-28-2026-27.pdf
ATTACHMENT
MakeInIndiaPolicy2017.pdf
ATTACHMENT
TelecomCircularNo.09_1.pdf
ATTACHMENT
GCC202210NosCorrectionSlipsofGCC_compressed.pdf GCC and 10 Nos Correction Slip
ATTACHMENT
GCCACS-11dated13.03.26_compressed.pdf
ATTACHMENT
GCC Corection Slip No 12
ATTACHMENT
GCC202210NosCorrectionSlipsofGCC_compressed.pdf
ATTACHMENT
ACSNo12ofIndianRailwayStandardGCCApril-2022issuedon12-08-2026.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .