| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹107.1 CrAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹110.9 Cr+₹3.9 Cr (3.62%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹112.7 Cr+₹5.7 Cr (5.28%)Admitted-Finance SURVEY NO 427P 3 4 431P 1 2 OPP NOVA PETROCHEMICALS SARKHEJ BAVLA HIGHWAY POST MORAIYA TALUKA SANAND AHMEDABAD 382210 | AHMEDABAD | SANAND | GUJARAT | 382210 | L3 | Admitted-Finance | |
| 4 | L4₹120.9 Cr+₹13.9 Cr (13.0%)Admitted-Finance 8TH FLOOR BRIGADE OPUS KODIGEHALLI MAIN ROAD BANGALORE KARNATAKA 560092 | BENGALURU URBAN | KARNATAKA | 560092 | L4 | Admitted-Finance | |
| 5 | L5₹135.9 Cr+₹28.9 Cr (27.0%)Admitted-Finance VITHAL UDYOGNAGAR ANAND GIDC ESTATE PLOT NO 1503 04 PHASE IV 388315 | ANAND | ANAND | GUJARAT | 388315 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bharat Bijlee.com L1 | ABB Power Products and Systems india Limited L4 | ATLANTA ELECTRICALS. PVT LTD L5 | Technical Associates Limited L2 | Transformers and Rectifiers India Ltd. L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00Electrical Items : | ||||||||
| 1.01 | 50MVA 132/33KV, Three phase ONAN/ ONAF cooled power transformer including unloading on plinth at site fitted with air cell, Transformer conservator isolation valve (TCIV) as described in cl.14.3 and all accessories/ fittings including OLTC as described under Annexure-II of Volume-II duly passed all routine additional routine and acceptance tests as per IS-2026 with one set of tools as per Annexure-X (Vol-II) but without first filling of oil and meeting all technical requirement as per specification. The transformers shall be supplied fitted with Impact Recorder (on returnable basis) during transportation of Transformers and Vehicle tracking system (GPRS/ GPS/ GSM based) to track the exact position of the vehicle during transportation of Transformers as per clause no. 38.0 of Volume-II | 40 | Nos | 2,67,62,400 ₹1,07,04,96,000 Lowest | 3,02,31,010 ₹1,20,92,40,400 | 3,39,84,010.62 ₹1,35,93,60,424.8 | 2,77,30,000 ₹1,10,92,00,000 | 2,81,78,400 ₹1,12,71,36,000 |
| 2.00Unit price of following items included in the Offered cost of transformer mentioned above shall be Offered separately. | ||||||||
| 2.01 | Transformer conservator isolation valve (TCIV) | 1 | Nos | 1,06,200 ₹1,06,200 | 1,17,410 ₹1,17,410 | 1,18,009.44 ₹1,18,009.44 | 1,18,000 ₹1,18,000 | 41,300 ₹41,300 Lowest |
| 3.00Charges for conducting Type test as per clause 29.3 of Volume-II | ||||||||
| 3.01 | Temperature rise test (Heat run test) | 1 | Nos | - | - | - | - | - |
| 3.02 | Vacuum and pressure test on tank | 1 | Nos | - | - | - | - | - |
| 4.00ii. Charges for conducting Special test as per clause 29.4 of Volume-II | ||||||||
| 4.01 | Measurement of zero seq. impedance as per cl.16.10 of IS-2026 Part I | 1 | Nos | - | - | - | - | - |
| 4.02 | Measurement of acoustic noise level as per cl.16.12 of IS:2026 part I | 1 | Nos | - | - | - | - | - |
Tender Value
₹107.6 Cr
EMD Value
₹2.2 Cr
Closing Date
14 Oct 2020, 3:30 pmClosed
O/o CE(Procurement) Jabalpur
Block no.3 MPPTCL Shakti Bhawan Rampur Jabalpur
PROCUREMENT OF 50MVA 132/33kV POWER TRANSFORMERS Against TR29/2020
2020_MPPTC_105451_1
TR-29/2020
Open Tender
Electrical Goods/Equipments
Item Wise
1290 days
MPPTCL sites
As per Tender Specification
3 documents required · 3 mandatory
₹56,000
Yes
Payable To RAO MPPTCL Jabalpur
₹2.2 Cr
Yes
13 Nov 2020
5 Sept 2020
15 Oct 2020
5 Sept 2020
14 Oct 2020
9 Oct 2020
Electrical Items :
50MVA 132/33KV, Three phase ONAN/ ONAF cooled power transformer including unloading on plinth at site fitted with air cell, Transformer conservator isolation valve (TCIV) as described in cl.14.3 and all accessories/ fittings including OLTC as described under Annexure-II of Volume-II duly passed all routine additional routine and acceptance tests as per IS-2026 with one set of tools as per Annexure-X (Vol-II) but without first filling of oil and meeting all technical requirement as per specification. The transformers shall be supplied fitted with Impact Recorder (on returnable basis) during transportation of Transformers and Vehicle tracking system (GPRS/ GPS/ GSM based) to track the exact position of the vehicle during transportation of Transformers as per clause no. 38.0 of Volume-II
Unit price of following items included in the Offered cost of transformer mentioned above shall be Offered separately.
Transformer conservator isolation valve (TCIV)
Charges for conducting Type test as per clause 29.3 of Volume-II
Temperature rise test (Heat run test)
Vacuum and pressure test on tank
ii. Charges for conducting Special test as per clause 29.4 of Volume-II
Measurement of zero seq. impedance as per cl.16.10 of IS-2026 Part I
Measurement of acoustic noise level as per cl.16.12 of IS:2026 part I
Measurement of power taken by fans as per clause 16.14 of IS-2026 Part I
Measurement of harmonic level of no load current as per clause 16.13 of IS 2026 Part I
IP:55 test on one cooler control cabinet & OLTC cabinet for transformer in accordance with IS : 2147
Test to prove over fluxing capability of transformer.
Technical Associates Limited
Transformers and Rectifiers India Ltd.
ABB Power Products and Systems india Limited
ATLANTA ELECTRICALS. PVT LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
VolumeIITR2920.pdf
Tender Documents • 1.09 MB
VolumeITR2920.pdf
Tender Documents • 2.21 MB
BOQ_123514.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .