GEMC-511687752495795
Awarded to Digilab India
₹2.1 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FLUKE-1732/INTL, THREE PHASE ELECTRICAL ENERGY LOGGER | FLUKE-1732/INTL, THREE PHASE ELECTRICAL ENERGY LOGGER | - | 1 NOS | ₹2.1 L | 209,930 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.1 LQualified Make: FLUKE
Model: FLUKE-1732/INTL, THREE PHASE ELECTRICAL ENERGY LOGGER 212 AGARAWAL CITY SQURE MANGALAM PALACE ROHINI SECTOR 3 NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Make: FLUKE
Model: FLUKE-1732/INTL, THREE PHASE ELECTRICAL ENERGY LOGGER | L1 | Qualified | |
| 2 | L2₹2.7 L+₹60,369 (28.8%)Qualified Make: FLUKE
Model: Fluke 1732/INTL 66 2ND CROSS STREET PALLAVAN NAGAR EXT MADURAVOYAL CHENNAI PORUR TIRUVALLUR TAMIL NADU 600095 | CHENNAI | TAMIL NADU | 600095 | Make: FLUKE
Model: Fluke 1732/INTL | L2 | Qualified | |
| 3 | Disqualified Make: Metrel
Model: Metrel MI 2883 Energy Master Class S FLAT NO 4 ANANDNIWAS APARTMENT I F PANCHSHIL APT SHREE SADGURU NAGAR MARG GOVIND NAGAR NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | Make: Metrel
Model: Metrel MI 2883 Energy Master Class S | - | Disqualified | |
| 4 | Disqualified Make: FLUKE
Model: FLUKE-1736/INTL, THREE PHASE POWER LOGGER 506 701 SIDDARTH BUILDING 96 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | Make: FLUKE
Model: FLUKE-1736/INTL, THREE PHASE POWER LOGGER | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
27 Aug 2018, 11:00 amClosed
power quality analyzers Power Quality Analyzers ( 1 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type of Power analyzer Three phase Single phase
Three phase Number of Current Channels (Nos.) 3 1
2
3
4 Number of Voltage Channels 4 1
4 Measurable voltage range 1000 600
1000 Measurable voltage accuracy 0.2 0.04
0.1
0.2
0.5
1 Measurable voltage resolution 0.1 1
0.1 Measurable current range (with clamp) 2000 5000
2000 Measurable current accuracy (%) ±1 ±0.04
±0.1
±0.2
±0.5
±1 Measurable current resolution 0.1 0.1
1
10 Maximum power that can be measured 400 4
40
400 1/5 (KW) Power Accuracy (%) ±1.5 ±1.5
±2
±2.5 Power resolution 1 1
5
50
500 MEASUREMENT FEATURES Facility to Measure Frequency Available * Frequency range that can be measured 40-65 Hz * Facility to Measure Inter harmonics Available * Order(n) to which Facility to Measure Harmonics available upto 50th * Facility to Measure Power Factor Available * Accuracy in measurement of Power Factor (%) 0.1 * Facility to Measure Distortion Factor Available * Accuracy in measurement of Distortion Factor (%) 2 * Facility to Measure Ripple Factor Not-Available * Accuracy in measurement of Ripple Factor (%) NA * Facility to Measure crest factor Not-Available * Measurable crest factor range NA * Measurable crest factor accuracy (%) NA * Measurable crest factor resolution NA * Facility to Measure sag(dips) and swell(surge) Not-Available * Pattern of measurement of sag(dips) and swell(surge) NA * Facility to Measure Total Harmonic distortion Available * Accuracy in measurement of Total 2 * 2/5 Harmonics distortion Facility to Measure voltage and current unbalance NA * Facility to Measure inrush current Not-Available * Facility to Measure flicker Not-Available * DISPLAY Display type LCD TOUCH * Display Mode Waveform
Meter Reading
Vector
digital reading * GENERAL FEATURES Facility to Measure RMS Voltage Available * Facility to Measure RMS Current Available * Facility to Measure Active
Reactive and Apparent Power Available * Facility to Measure Active
Reactive and Apparent Energy Available * GENERIC Data transfer software provided for analysis on PC Yes * Provision for external SD Card no * Interface USB * Internal Memory (GB) 1 * Weight of the analyser 1.5 * other features Three-Phase Electrical Energy loggers with Bright
color touch screen
* POWER SOURCE/BATTERY Power Supply Battery operated
230 V AC +/- 10%
50Hz * If battery operated
chemistry of the rechargeable battery lithium ion * Voltage of rechargeable Battery 3.7 * capacity of rechargeable battery (milli AH) 9.25 WH * Suitable charger adaptor provided yes * 3/5 Battery backup (hours) 6 * OPERATING CONDITION Minimum Operating Temperature -10 * Maximum Operating Temperature 45 * Operating Humidity (%) 90 * ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the Analyser Energy Logger
International version (includes current probes)
Power supply
Voltage test leads
Alligator clips (4x)
12 in 1
500A flexible current probe (3x)
Soft case
Energy Analyze Plus software
Line cords
Color coding set
Documentation on USB flash drive * SAFETY Compliance to IEC 61000-4-30 Yes * Category of safety rating Category IV 600 V of IEC 61010 * TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hours at a specified maximum temp in accordance with IS:9000/part-3/sec tion-5/1977 latest Yes * conformity to Cold Test for 4 hours at a specified minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest Yes * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH yes * Availability of Test Reports from Central Govt/NABL approved/ILAC accredited lab to prove conformity to the specification Yes * 4/5 Test Report Number and date FLUKE/2018/56236548 9 DTD. 01.04.2018 * Name and address of the Lab FLUKE TECHNOLOGIES PVT. LTD.
BHIWANDI
MAHARASHTRA * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ajit Kumar Alok 144602
Cheif Plant Engineer
Rail coach Factory
Kapurthala
1 15
499223
GEM/2018/B/70659
GeM Contract
power quality analyzers
GeM Contract
15 days
Punjab; Kapurthala
PRODUCT
Awarded to Digilab India
₹2.1 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FLUKE-1732/INTL, THREE PHASE ELECTRICAL ENERGY LOGGER | FLUKE-1732/INTL, THREE PHASE ELECTRICAL ENERGY LOGGER | - | 1 NOS | ₹2.1 L | 209,930 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| power quality analyzers Power Quality Analyzers ( 1 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type of Power analyzer Three phase Single phase | - | - | - |
| Three phase Number of Current Channels (Nos.) 3 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 Number of Voltage Channels 4 1 | - | - | - |
| 4 Measurable voltage range 1000 600 | - | - | - |
| 1000 Measurable voltage accuracy 0.2 0.04 | - | - | - |
| 0.1 | - | - | - |
| 0.2 | - | - | - |
| 0.5 | - | - | - |
| 1 Measurable voltage resolution 0.1 1 | - | - | - |
| 0.1 Measurable current range (with clamp) 2000 5000 | - | - | - |
| 2000 Measurable current accuracy (%) ±1 ±0.04 | - | - | - |
| ±0.1 | - | - | - |
| ±0.2 | - | - | - |
| ±0.5 | - | - | - |
| ±1 Measurable current resolution 0.1 0.1 | - | - | - |
| 1 | - | - | - |
| 10 Maximum power that can be measured 400 4 | - | - | - |
| 40 | - | - | - |
| 400 1/5 (KW) Power Accuracy (%) ±1.5 ±1.5 | - | - | - |
| ±2 | - | - | - |
| ±2.5 Power resolution 1 1 | - | - | - |
| 5 | - | - | - |
| 50 | - | - | - |
| 500 MEASUREMENT FEATURES Facility to Measure Frequency Available * Frequency range that can be measured 40-65 Hz * Facility to Measure Inter harmonics Available * Order(n) to which Facility to Measure Harmonics available upto 50th * Facility to Measure Power Factor Available * Accuracy in measurement of Power Factor (%) 0.1 * Facility to Measure Distortion Factor Available * Accuracy in measurement of Distortion Factor (%) 2 * Facility to Measure Ripple Factor Not-Available * Accuracy in measurement of Ripple Factor (%) NA * Facility to Measure crest factor Not-Available * Measurable crest factor range NA * Measurable crest factor accuracy (%) NA * Measurable crest factor resolution NA * Facility to Measure sag(dips) and swell(surge) Not-Available * Pattern of measurement of sag(dips) and swell(surge) NA * Facility to Measure Total Harmonic distortion Available * Accuracy in measurement of Total 2 * 2/5 Harmonics distortion Facility to Measure voltage and current unbalance NA * Facility to Measure inrush current Not-Available * Facility to Measure flicker Not-Available * DISPLAY Display type LCD TOUCH * Display Mode Waveform | - | - | - |
| Meter Reading | - | - | - |
| Vector | - | - | - |
| digital reading * GENERAL FEATURES Facility to Measure RMS Voltage Available * Facility to Measure RMS Current Available * Facility to Measure Active | - | - | - |
| Reactive and Apparent Power Available * Facility to Measure Active | - | - | - |
| Reactive and Apparent Energy Available * GENERIC Data transfer software provided for analysis on PC Yes * Provision for external SD Card no * Interface USB * Internal Memory (GB) 1 * Weight of the analyser 1.5 * other features Three-Phase Electrical Energy loggers with Bright | - | - | - |
| color touch screen | - | - | - |
| * POWER SOURCE/BATTERY Power Supply Battery operated | - | - | - |
| 230 V AC +/- 10% | - | - | - |
| 50Hz * If battery operated | - | - | - |
| chemistry of the rechargeable battery lithium ion * Voltage of rechargeable Battery 3.7 * capacity of rechargeable battery (milli AH) 9.25 WH * Suitable charger adaptor provided yes * 3/5 Battery backup (hours) 6 * OPERATING CONDITION Minimum Operating Temperature -10 * Maximum Operating Temperature 45 * Operating Humidity (%) 90 * ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the Analyser Energy Logger | - | - | - |
| International version (includes current probes) | - | - | - |
| Power supply | - | - | - |
| Voltage test leads | - | - | - |
| Alligator clips (4x) | - | - | - |
| 12 in 1 | - | - | - |
| 500A flexible current probe (3x) | - | - | - |
| Soft case | - | - | - |
| Energy Analyze Plus software | - | - | - |
| Line cords | - | - | - |
| Color coding set | - | - | - |
| Documentation on USB flash drive * SAFETY Compliance to IEC 61000-4-30 Yes * Category of safety rating Category IV 600 V of IEC 61010 * TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hours at a specified maximum temp in accordance with IS:9000/part-3/sec tion-5/1977 latest Yes * conformity to Cold Test for 4 hours at a specified minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest Yes * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH yes * Availability of Test Reports from Central Govt/NABL approved/ILAC accredited lab to prove conformity to the specification Yes * 4/5 Test Report Number and date FLUKE/2018/56236548 9 DTD. 01.04.2018 * Name and address of the Lab FLUKE TECHNOLOGIES PVT. LTD. | - | - | - |
| BHIWANDI | - | - | - |
| MAHARASHTRA * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ajit Kumar Alok 144602 | - | - | - |
| Cheif Plant Engineer | - | - | - |
| Rail coach Factory | - | - | - |
| Kapurthala | - | - | - |
| 1 15 | - | - | - |
Exempted
7 Sept 2018
21 Aug 2018
contract_GEMC-511687752495795.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_499223.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .