Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹19.5 L+₹13,576 (0.70%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹19.7 L+₹27,551 (1.42%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹20.4 L+₹97,614 (5.04%)Rejected-AOC 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC OK | |
| 5 | L5₹21.2 L+₹1.8 L (9.47%)Rejected-AOC | L5 | Rejected-AOC OK |
Tender Value
₹24.9 L
EMD Value
₹49,800
Closing Date
3 Mar 2020, 6:00 pmClosed
CWE PATHANKOT
HQ CWE PATHANKOT
SPL REPAIR TO BUILDING NO NP-12 (OTM ACCN) AT BHADURIYA COMPLEX UNDER GE (SOUTH) PATHANKOT
2020_MES_319225_1
CWE/P-49/2019-20
Open Tender
Civil Works
Item Rate
180 days
Pathankot
Class E category a i
9 documents required · 9 mandatory
₹500
Yes
GE (South) Pathankot
₹49,800
Yes
28 May 2020
28 Jan 2020
5 Mar 2020
28 Jan 2020
3 Mar 2020
11 Feb 2020
Amount
Dismantling of brick tile or terracing tiles, single layer on roof upto any height and removing all unserviceable materials outside the Cantt area complete all as specified.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and including taking out existing roof treatments, brushing neat cement slurry with 3.0 Kg of cement per sqm and including 10mm thick rendering in cement mortar 1:4 mixed with WPC 3% by wieght of cement on fair faces of concrrete roof surfaces, finsihsed even and fair to receive treament on roof etc complete all as specified. Note: WPC shall be measured and paid separately
Supply only Integral water proofing compound.
Providing and laying of water proofing treatment of roof APP (Atactic Polyproplyllen) modified prefabricated five layer 3mm thick water proofing membrane, super thermply non woven polyester mat reinforcement of 160 gsm, weight of membrane @ 3.6 Kg/Sqm over a solvent based bitumen primer @ 0.3 Ltr Sqm by the same manufacturer conforming to IS:3384-1986 , The membrane shall be laid using bitmun torch.The end lap should be 100 mm and the side lap must be minimum 75 mm the membrane shall be first laid up to the parapet wall junction and then shall be overlapped with another membrane (flashing) with an overlap covering up to a distance of 300mm. In case parapet height is less than/ up to 500 mm, membrane shall be terminated at the top of parapet.All rain water pipe opening shall be suitably sealed with the APP membrane all as specified and directed. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster)
M&L 40 mm thick brick tiles bedded in cement mortar (1:6), 15mm thick and joints grouted flush in cement mortar (1:3) mixed with 5% of cruded oil by weight of cement.
Taking down chowkats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5 Sqm each and removing from site complete all as specified.
As per Srl itme No 6 here-in-before, but exceeding 1.5 Sqm and n.exc. 4 Sqm each (without taking off sutters from the frames) complete all as specified and directed.
Taking down shutters of any description exceeding 1sqm and not exceeding 2 sqm each, complete all as specified and directed.
S&F for Steel windows with tubular frame factory made with double shutter (wire gauged shutter & glass glazed shutter, wire cloth and glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl projecting type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete, including two coats of synthetic enamel paint over one coat of red oxide primer all as specified & pattern shown in drg No CEPZ/ID-245/01 and 246/02 sheet ½ & 2/2.
S&F steel ventilator with tubular frame factory made of size 79mmx39mm, 16 gauge rectangular tubular frame with side hung shutter ,bottom portion glazed and top portion gauzed shutter with glazing bars 12x3mm flat iron including projecting type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills and frosted glass and wire cloth complete, including two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L 35mm thick 2nd class soft wood (kail) plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board with commercial face veneers fitted to chowkats of size as IS-1003 Part-01, complete all as specified and directed.
S&F for 35 mm thick shutter for door of 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc complete
M & L Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), solid core panal design with 5 mm thick 3D wood grain printed (multi colour) PVC Sheet Polyurethane printed on the front face and 5mm Prelam PVC sheet on back face, complete all as specified and directed
M & L factory made solid PVC puff door frame of size 90x55mm made out of 5mm thick plain colour PVC sheet with one or more rebate reinforced with MS square tube fixed in opening as per specification and drawings No CEPZ/TD-378 / 11 sheet No 1/1 etc complete all as specifed and directed.
M & L 1.25mm thick pressed steel frames with one coat of red oxide primer 105 x 60 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate, including cement concrete type C-1, 1:3:6 (using 20 mm graded crushed stone aggregate) as in filling hollow of frame with plain cement concrete and hold fast after taaring of hollow portion of frame complete all as specified and directed
M & L 1.25mm thick pressed steel frames with one coat of red oxide primer 125 x 60 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate, including cement concrete type C-1, 1:3:6 (using 20 mm graded crushed stone aggregate) as in filling hollow of frame with plain cement concrete and hold fast after taaring of hollow portion of frame complete all as specified and directed.
S&F Mild steel sliding door bolts, stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolts plate and two on staple plate, 300mm long, all as specified.
S&F Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised of size 150mm and fixed, complete all as specified and directed.
M&L of two coat of synthetic enamel paint over a coat of pink primer on new wooden surface of any description, not otherwise described over 10 cm width or girth, incliding preparation of surfaces complete, all as specified.
M & L Preparation new or previously untreated steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified.
S&F Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples or nut and bolts including MS flat strip as required at site , complete all as specified.
M & L 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified.
Taking down cement plaster or cement line plaster on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
Removing old lime wash (if any) hacking for key,raking out joints of old brick work or stone work built in cement mortar not previously plastered,and scrubbing down with water etc. to receive plaster complete all as specified.
M&L 15mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
M & L 15mm thick rendering in cement mortar 1:6 on fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
M&L for preparation of new plastered external surfaces of walls and applying two coats cement base paint of approved brand over a coat of primer all as specified and as directed .
M & L for complete removal/scrapping of existing treatment and applying one coat of cement base paint to old decorated surfaces of wall complete all as specified and as directed .
M&L for preparation of new plastered surface and applying two coats of oil bound distemper over and including approved primer, complete as specified and directed.
M&L preparation of old plastered or un plastered wall surfaces after complete removal/scrapping of existing treatment and applying two coats of oil bound distemper, complete all as specified
M& L Applying three coats of white wash including preparation of newly plastered surfaces of wall complete all as specified.
M& L Applying three coats of white wash including preparation of old plastered or un plastered wall surfaces after complete removal/scrapping of existing treatment of wall complete all as specified.
M& L Applying three coats of white wash including preparation of newly plastered surfaces of ceiling complete all as specified.
M& L Applying three coats of white wash including preparation preparation of old plastered or un plastered ceiling surfaces after complete removal/scrapping of existing treatment of ceiling complete all as specified.
Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, Complete all as specified and directed.
M & L Steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings fixed to walls and ceilings or laid in floors, complete all as specified.
M & L Steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings fixed to walls and ceilings or laid in floors, complete all as specified.
S & F 20mm bore gun metal globe or gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe fixed in repair, complete all as specified.
Demolition of old broken AC tanks and removing from site capacity exceeding 500 ltr and not exceeding 1000 ltr complete all as specified and directed.
Supply and fxing rotational moulded polythene water storage tank, white coloured, tripple layer cylindrical vertical with closed top 1000 litre capacity hoisted and fixed in position, including inlet and outlet pipe connections, 20mm dia and 15 mm dia GI pipes medium grade respectively, 20mm GI pipe medium grade over flow pipe 15 cm long wash out with plug complete all as specified and directed.
S & F Ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule, 20mm bore complete all as specified and directed.
S&F in repairs bib taps 15mm bore of cast copper alloy chromium plated fancy type with long shank with capstan head, screwed down, high presure , screwed both ends for iron pipe or for brass ferrule, fixed, complete all as specified and directed.
S & F in repairs brass chromium plated (ISI marked) shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed
S&F in repair 15mm bore Stop valve/angle valve cast copper alloy screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed, complete all as specified.
Supply & Fix in repair Vitreous china urinal half stall complete incl providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and incl 60mm long brass secrews, pointing around urinal in back in cement; fixing automatic cistern with brackts, flush pipe, grating and union for discharge pipe complete all as specified and directed.
Supply & Fix Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
M&L PVC connection 15mm size with PTMT nuts on both ends of length 450mm , complete all as specified.
S & F Tubular towel rail 60cm long between flanges , 20mm dia D type Brass , Chromium plated incl necessary brackets, fixed with chromium plated screws and wooden/plastic cleats complete all as specified and directed.
Supply and fixed in repairs shelf of PTMT fixed with and incl chromium plated brass screws and wooden/plastic cleats min weight 300 gms complete all as specified and directed.
S&F in repair Vitreous china Wash hand basin, white, flat back of size 550x400mm including brackets, brass chromium plated waste coupling, and waste pipe PVC 32mm dia including cutting for and pinning in ends of brackets or erecting stand etc, complete all as specified.
M&L 15 mnm Pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repair complete all as specified.
S & F soap dish of CP fixed with and including chromium plated brass screws and wooden/plastic plugs, all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fitting, head, shoes, bend, swan-nacks etc, including cleaning for refixing or removal to store .
S & F PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint laid in trenches/floor/walls as soil pipe(vent pipe)/weep holes, fixed, complete all as specified and directed.
PVC (SWR) shoe of 110mm bore, complete all as specified.
S & F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), including removing rubbish/debris outside defence land complete all as specified and directed.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), including removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base for receiving tiles , complete all as specified.
M & L Non-skid cermic coloured tiles 7 to 8 mm thick (square / rectagular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over screed bed 15 mm thick in cement mortar 1:4 complete all as specified.
M & L Joint free coloured/ printed glazed ceramic tiles (first quality) of size 300 x 450 x 7mm thick on vertical surfaces such as dado with highlighter etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over 10 mm thick rough cement plaster to recieve tiles in cement mortar 1:4 complete all as specified.
M& L Pre polished machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and (mirror) polishing complete & 20mm thick screed bed in cement mortar 1:4 and including demolition of existing floor topping complete all as specified.
M & L Pre polished Kota stone slab 18-20mm thick fixed in vertical surfaces such as skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and (mirror) polishing & 10mm thick cement plaster to recieve stone in cement mortar 1:4 including demolition of existing wall skirting etc complete all as specified & directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified & directed.
M&L rendering 10mm thick on concrete surface in CM 1:3 in facia or edging of chajjas, ceiling and roof projection etc incl taking out pealed off plaster/concrete and making good to cracked RCC surface in true line /shape by providing RCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate including all necessary form work to thickness at required at GF and FF finish even and smooth without using extra cement complete all as specified and as directed by eng-in charge. NOTE- the rate will be inclusive of scafolding for single or double storey including making hole in brick work and making good in cement mortar.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described including removing rubbish/debris outside defence land complete all as specified and directed.
M & L 75 mm thick cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in plinth protection etc and laid in alternate bays complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of 01 bitumen 85/25 grade and three part of sand by weight all as specified and directed
Supply and fxing , 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate (ISI marked) complete including all neccesary welding if required all as specified.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M & L walling of random rubble stone masonry uncoursed , well bonded, bedded and solidly hearted, built in cement mortar (1:4), complete all as specified.
M & L raking out joints / Pointing to random rubble or polygonal rubble uncoursed or brought up to course work built in cement mortar, complete all as specified.
M & L 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified.
M & L prelaminated particle, board 18/19mm thick , exterior grade,prelmainated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in cup board shutters and shelvs complete all as specified and directed
S & F Continuous (piano) hinges, ISI marked mild steel, bright finish or electrogalvanised with width of flap (when open) 30mm complete all as specified and directed
S & F Hasp and staple,100 mm long aluminium anodised ( ISI Marked), including bolt to hinge plate and fixed with screws complete all as specified.
M & L brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 using old size bricks complete all as specified and directed
M&L RCC nominal mix 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in slab supported on walls, columns in floors, roofs, landings, balconies and in shelves, complete all as specified.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs etc and similar works rough finished complete all as specified & directed
M & L TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
M & L Non-skid cermic coloured tiles 7 to 8 mm thick (square / rectagular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces like skirting/dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, including screed bed 10 mm thick in cement mortar 1:4 complete all as specified.
M & L 2nd class hardwood plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails, n exc 3 Sq.cm in sectional area, complete all as specified & directed.
Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M&L Point wiring for light/fan/bell point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and including 1.5sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) (b) On RCC roof ceiling PVC conduit shall be provided on surface for fan with proper fixing clips all as directed.
All as per above item no 86.00 here in before but for one 3 pin socket outlet 5 amp on same board all as specified and directed.
All as per above item no 86.00 here in before but for one 3 pin socket outlet 5 amp on independent board all as specified and directed.
All as per above item no 86.00 here in before but for one light controlled by two way switch all as specified and directed.
M&L Point wiring for 15 Amp socket point controlled by one switch with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L Switch piano flush type 5 Amp single pole one way, (ISI marked), complete all as specified.
M&L switch socket outlet 6 pin, 5 & 15 Amp multipurpose 2 in 1 flush type,complete all as specifed.
M&L switch socket outlet combination 2 in 1 , 3 pin 5 Amp flush type all as specified & directed.
M&L Switch piano flush type 5 Amp single pole two way, (ISI marked), complete all as specified.
M&L Switch piano flush type 15 Amp single pole one way, (ISI marked), complete all as specified.
Supply and Fix in replacement existing UNSV tube light fitting with LED 20W inverter batten type fitting 4 feet long aluminium extruded housing, charging time 10-12 hours and back up time 04 hours, IP-20 ,rated voltage 230 V, 50 hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed. Notes: (i) LM79 report from third party (instead of company in house lab) NABL/UL accredited lab (ii) LM 80 report from LED manufacturer (iii) Test certificates to be submitted before commencement of work/ claiming for payment . (iv) Warranty certificate for minimum 2 years to be submitted from OEM.
M&L Ceiling rose, 3 terminal of bakelite 65x50mm two or three therminals isolated body fixed on PVC round block complete all as specified.
M&L Lamp holder Polycarbonate type with back plate having matching colour to holder for angle/batten fittings complete all as specified and directed.
Supply and fixing in replacement existing unsv integrated LED bulk head light fitting 1X10 watts IP-65 protection connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
M&L Stepped type electronic fan regulator 0 to 4/5 step , flush type, heavy duty with hum free snubber circuit complete all as specified.
S&F in replacement sheet metal enclosure factory made (Double door) type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete, single pole and neutral, 240 volts, 50 Hz, 8 way with 200Amps rated copper bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, complete all as specified.
M&L MCB SP 6 to 32 Amp, 240V with 10KA breaking capacity of 'C' series 10 KA, including providing thimbles to outgoing cable all as specified and directed.
S&F MCB single pole & neutral 20 to 32 Amps, 240 Volts 'C' series, 10 KA, including providing thimbles to outgoing cable complete all as specified.
Supply and laying in replacement of existing unserviceable/ burnt submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 4 sqmm drawing into and including concealed PVC rigid non metallic conduit of 20mm dia , 1.8 mm wall thickness and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 4 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing complete all as specified & directed. Note: (i) Two runs of 4 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 4 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 20mm dia , 1.8 mm wall thickness wiil be measured as a one unit. (ii) Proper colour coding is to be followed as per IS Specification. (iii) Test certificates of cables to be submitted before commencement of work/ claiming for payment. (iv) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement. (v) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
Supply and laying in replacement of existing unserviceable/ burnt submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 6 sqmm drawing into and including concealed PVC rigid non metallic conduit of 20mm dia , 1.8 mm wall thickness and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 6 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing complete all as specified & directed. Note: (i) Two runs of 6 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 6 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 20mm dia , 1.8 mm wall thickness wiil be measured as a one unit. (ii) Proper colour coding is to be followed as per IS Specification. (iii) Test certificates of cables to be submitted before commencement of work/ claiming for payment. (iv) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement. (v) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3 of SSR Part I, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI medium grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame, necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified. Note: The rate quoted include cost of 7.5 metre earthing wire with protection pipe.
S&F Geyser 25 Ltrs capacity, 230 volts, vertical type with 5 stars rating suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc incl necessay drilling, provn of anchor bolts of suitable size and making electrical connections complete all as directed by Engr-in-charge.
Dismantling old unserviceable solar water heater depositing to MES storeyard and Supply, installation and testing of solar Water Heating system at 60 degree C (Avarage) temperature, comprising of : (a) Flat Plate collector(as per BIS 12933),01 No for each system of 100 LPD with heating electric backup (b) Stand for the collectors (c) Hot water tank (SS-304) TIG welded with PUF insulation & Stainless Steel Outer cladding (d) Stand for hot water Tank (e) Hydraulic steam hose pipe with with check nut (f) Air vent 1 No for each system Make: As per list approved by MNRE on their website Note: The angle iron supports for solar stand will be measured and paid separately under relevent schedule items.
S&F in repairs hot water pipe duly insulated with glass wool and aluminium cladding of 15 mm bore complete all as directed by Engr-in-charge.
S&F in repairs hot water pipe duly insulated with glass wool and aluminium cladding of 20 mm bore complete all as directed by Engr-in-charge.
S&F in repairs hot water pipe duly insulated with glass wool and aluminium cladding of 25 mm bore complete all as directed by Engr-in-charge.
Supply and fixed in repair 20mm bore gun metal gate valve (ISI marked) iron wheel head,screwed both ends for iron pipe complete all as specified.
Supply and fixed in repair 25mm bore gun metal gate valve (ISI marked) iron wheel head,screwed both ends for iron pipe complete all as specified.
Supply and fix in trenches/on roof/on wall steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings , complete all as specified..
Supply and fix in trenches/on roof/on wall steel water tubing of 25 mm bore ‘medium grade’ galvanized with all fittings , complete all as specified..
S & F ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule, 25mm bore, complete all as specified and directed .
M & L PCC 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate) for the bottom basement layer of the solar water heater stand/water tank including dismantling existing brokrn cement concrete , complete all as specified and directed.
Dismantling old rusted angle iron stand and M & L for repair of solar panel/Solar water tank stand made of fabricated MS steel (angular iron, channel, flat,nut & bolts etc) including welding, rivetting jointing and bending of any shape including two coat of enammel paint and one coat of red oxide paint as directed by Engineer-in Charge.
S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with including one single pole MCB 240V, 20Amp complete all as specified and directed
Supply and Fix in replacement existing unsv sleek LED mirror light fitting 2 feet long 1x10 W having bipin holder, connector block etc complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
Supply & Fix Ceiling fan AC single phase 230/240 volts of size 1200 mm sweep complete (BLDC) type BEE 5 star rated including blade ,down rod etc including connecting to ceiling rose all as required or directed. Note: Test report and Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment.
Supply & Fix Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvre including connecting to ceiling rose all as required or directed including connecting to ceiling rose all as required or directed.Note: Test report and Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment.
Supply & Ventilation fan AC sinlge phase 230/240 volts of size 200 mm sweep having plastic body with louvre including connecting to ceiling rose all as required or directed including connecting to ceiling rose all as required or directed.Note: Test report and Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment.
Supply laying jointing and testing LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35sqmm 3.5 core complete all as specified. Note : Earth work , sand cushioning, GI pipe , brick covering for mechanical protection will be measured and paid separately under respective item of Schedule.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation laying poles, stay assembly and laying of LT/HT cables in any type of soil and getting out, complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Removal of excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed
M & L Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be made and paid.
M & L Sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Supply,fixing, testing & commissioning of LED street light fitting 45 watt, fixed on Bldg comprising of epoxy powder coated housing, enclosed with glass cover in frame, for efficiency not less than 95 lumens/Watt, and minimum wattage capacity of 45 W with ingress protection IP 65/66 and external SPD of capacity 10 KV in addition to inbuilt with drive complete fixed to and including 25 mm dia medium grade GI pipe bracket of length not less than 1.20 m bend to 120 degree shape with necessary GI clamps 50mmx6mm MS strip bend to required shape, nut bolts etc and 1.5 Sqmm 3.5 core PVC flexible copper cable from junction box to fitting to be layed /drawn inside steel tubular pole complete and testing on completion all as specified and as directed. Note :(i) Minimum 2 years guarantee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iii) Power factor more than 0.9 (iv) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply and fix LED Lamp inverter type 12 watt 230 volts,50 Hz, ,lumen 1200 lm, rated current 60 mA, CRI less than 80, Charging time 8 to 10 Hours, operating temperature -10 to 50 degree celcius,back up time 04 Hours, complete all as specified and directed.
S & F in replacement existing unsv distribution board iron clad, double door with IP-54 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with including one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed.(Outgoing MCB will be measured separately). Make: L&T/Schneider/Hager/C&S.
Supply and fxing rotational moulded polythene water storage tank, white coloured, tripple layer cylindrical vertical with closed top 250 litre capacity hoisted and fixed in position, complete all as specified and directed.
Supply and fxing rotational moulded polythene water storage tank, white coloured, tripple layer cylindrical vertical with closed top 500 litre capacity hoisted and fixed in position, complete all as specified and directed.
S&F LED Lamp, inverter type 9 watt 230 volts,50 Hz, ,lumen 900 lm, rated current 35 mA, CRI less than 80, Charging time 8 to 10 Hours, operating temperature -10 to 50 degree celcius,back up time 04 Hours, complete all as specified and directed.
Supply, installation, testing and commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage Capacity of 80 Liter and nominal cooling capacity of 40 Liter per hour complete all as specified and directed.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
Abrol construction co
M/S Ajay Kumar Mahajan
satpal and brothers
VIKRAM SINGH MANHAS
M/S RUDHRAKSH TRADING CO
KULBHUSHAN AGGARWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .