Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹34.0 L+₹5,740.31 (0.17%)Rejected-Finance | L2 | Rejected-Finance Not Lowest. | |
| 3 | L3₹37.5 L+₹3.5 L (10.3%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L3 | Rejected-Finance Not Lowest. |
Tender Value
Refer Docs
EMD Value
₹63,600
Closing Date
21 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kamptee
Military Engineer Services Garrison Engineer Cantt Area Kamptee 441001
PROVN OF TOILET BLOCK FOR MI ROOM, NEAR BLDG NO P-5 AND ADDL TOILETS FOR JCO / OR AT FORT AREA NAGPUR UNDER GE KAMPTEE.
2020_MES_341162_3
8168/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee
Class D, Cat a (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹63,600
Yes
10 Oct 2020
25 Aug 2020
23 Sept 2020
26 Aug 2020
21 Sept 2020
9 Sept 2020
26 Aug 2020 - 8 Sept 2020
60 days
Amount
M&L for cutting openings through cement mortar walls for door, window and other openings or enlarging existing openings, etc or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises complete all as specified and directed.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc not exc 10 sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Excavating over areas, not exc 1.5m deep and getting out hard/dense soil complete all as specified and directed.
Excavating over areas, add each additional 1.5m or part of thereof in depth beyond the first 1.5m in hard/dense soil complete all as specified and directed.
Excavating over areas, not exc1.5m deep and getting out in hard rock by chiseling complete all as specified and directed.
M&L for providing cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, mass concrete and fillings complete all as specified and directed.
M&L for form work to sides of concrete in foundations, footing base, base of columns, sides and soffits of plinth beam and similar work complete all as specified and directed.
M&L for providing reinforcement cement concrete M-25 (Design Mix) as in footing, foundation, beams, plinth beams, base for columns and mass concrete etc complete all as specified and directed.
M&L for form work to sides of columns and similar work complete all as specified and directed.
M&L for form work to sides and soffits of floor and roof beam, beam haunching, lintels and similar work complete all as specified and directed.
M&L for providing reinforcement cement concrete M-25 (Design Mix) as in columns and pillars etc complete all as specified and directed.
M&L for providing reinforcement cement concrete M-25 (Design Mix) as in beams, cantilevers, bressummers, lintels over 1.5m span concrete etc complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for formwork to edges of concrete flat, breaks in floors and sides of RCC/PCC bends in wall and similar works not exceeding 200mm thick complete all as specified and directed.
M&L for providing reinforcement cement concrete M-25 (Design Mix) as in slabs supported on walls, beams and columns etc complete all as specified and directed.
M&L for providing reinforcement cement concrete M-25 (Design Mix) as in chajjas etc complete all as specified and directed.
M&L for use & waste of form work to sides, lintels, cantilevers etc complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape as required, including cranking, bending and binding with mild steel (annealed) wire not less than 0.90mm dia complete all as specified and directed.
All as per item No 19 above but 6 to 8mm dia for hooping for columns, hooking ends complete all as specified and directed.
All as per item No 19 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for brick with fly ash brick, old size, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
M&L for brick with fly ash brick, old size, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and as directed.
All as per item No 23 above but half brick thick wall in CM 1:4 complete all as specified and directed.
M&L for brick work with fly ash bricks in one brick thick honey comb walling, built in CM 1:6 complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick on concrete surfaces in CM 1:3, finished even and smooth without using extra cement on ceiling complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4, mixed with WPC, finished even and smooth without using extra cement complete all as specified and directed. Note:- WPC will be measured & paid separately.
Supply only liquid water proofing compound of approved quality complete all as specified and directed.
M&L for preparation surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparing newly plastered walls surfaces and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation of new surfaces of wall and applying two coats of oil bound distemper over a coat of birla white wall care putty complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7-8mm thick, area of each tiles exc 0.11 sqm but not exc 0.18sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick sceed bed in CM 1:6 complete all as specified and directed.
M&L for 20mm polished Granite (of any type) work (table rubbed and polished) in steps, jams, pillars; cooking platforms and likes in cement mortar (1:4) including pointing in white cement (1:2) using marble dust admixture of pigment to match with shade of granite including necessary notching, chamfering the edges complete all as specified and directed.
M&L for colored glazed ceramic tiles in vertical surface 350x 250x 7mm / 450X 350X 7mm /300x 450x 7mm thick, set and jointed in neat cement slurry and pointed in white or colored cement to match the shade of tiles over and including rendering 10mm thick in cement mortar 1:4 complete all as specified and directed.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base, etc complete all as specified and directed.
M&L for hardcore of gauge not exc 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface for plinth protection/path complete all as specified and directed.
M&L for providing 25mm thick cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate), as in sub base in floor/ paving etc complete all as specified and directed.
M&L for 75mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers not exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for loose filling with aggregate of gauge 80 to 150mm of broken bricks complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, mangers, shelves and similar articles with plain faces and set in CM 1:6 (reinforcement measured and paid separately) complete all as specified and directed.
M&L for 100mm thick cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base etc complete all as specified and directed.
M&L for sand filling under floor or in foundation including watering and consolidation etc complete all as specified and directed.
M&L for pre-polished machine pressed precast conctete interlocking paver block, any shape and size confirming to IS 15658-2006 of 80mm thickness, M-35 Grade with grey cement and no pigment etc complete all as specified and directed.
M&L for PCC (1:2:4) type B0 (using 12.50mm graded stone aggregate) as in copings, cills,steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, water troughs and the likes including weathering, slightly rounded for chamfered angles and throating complete all as specified and directed.
S&F pressed steel frame of size 125 x 60mm for door/ window with one or more rebated including necessary lugs, hinges lock strike plate complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay without glazing bar complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay with glazing bar complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate), for filling PS frame etc complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in fixing of hold fast, bed blocks etc including necessary form work as required complete all as specified and directed.
S&F mild steel framed work such as purlin, truss, square tube, MS pole, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, welded wire mesh and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
S&F 3mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.45mm nominal dia of wire and average width of aperature 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F 30mm thick flush shutter solid core construction with block board and plywood face, commercial type complete all as specified and directed.
S&F 35mm thick IInd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, guage etc, without sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, guage etc, size of members of shutters as specified in MES SSR Part-I, Section 8, Clause 8.24 (a) complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, in opening etc complete all as specified and directed.
S&F factory made soild panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails, MS frames shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strips of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rails, lock rails on other side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles and rails with sitable PVC sheet beading and joined together with sovent cement complete all as specified and directed.
S&F 100mm long medium weight, cold rolled, mild steel butt hinges complete all as specified and directed.
S&F 125mm long extruded aluminium alloy handles, fabricated type, anodised of complete all as specified and directed.
S&F 150mm long aluminum tower bolt complete all as specified and directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
M&L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation new steel and iron surfaces not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation new steel and iron surfaces not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment etc complete all as specified and directed.
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F mild steel screw bolt, 5 to 10mm dia, machine made with hexagonal head at one and screwed the other or screwed bolts each screwed end to be fitted with washer and one hexagonal or square nut not exc 5cm long complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tube conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 15mm bore steel water tubing, medium grade galvanized with all fittings & fixture complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore steel water tubing, medium grade, galvanized with all fittings & fixture complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting exc 10cm but not exc 20cm girth complete all as specified and directed.
M&L for 15mm dia gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for 20mm dia gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for 25mm dia gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F vitreous china wash down water closet (pedestal pattern) 'P' or 'S' trap including jointing, including plastic water closet seat, closed pattern with flat bottom and cover and mild steel CP or aluminimised hinging device complete all as specified and directed.
S&F vitreous china wash basin, white, flat back, size 550 x 400mm including bracket, fixed to wall complete all as specified and directed.
M&L for waste fittings, brass, 32/40mm, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F 15mm bore pillar tap, brass, CP, fancy type for WHB complete all as specified and directed.
S&F 15mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F 15mm dia stop valves, brass, CP, fancy type complete all as specified and directed.
S&F PVC connections of 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F 10 ltr capacity PVC low level flushing cistern, with its complete accessories, fixed including connection to water pipe and seat complete all as specified and directed.
M&L for laying 150mm dia salt glazed stone ware drain pipes of grade ‘A’ and jointed in cement mortar and tested on completion complete all as specified and directed.
M&L concrete bed to drain pipe including packing under and haunching against the side of pipe after they are laid and tested of 150mm bore complete all as specified and directed.
S&F GI framework for seamless ceiling of size 600mm x 600mm comprising of hot deep galvanized powder coated perimeter angle 0.30mm thick of size 24x24mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre, main runner Tee section 0.30mm thick with height 38mm and cross Tee 0.3mm thick with height 28mm suspended from soffit at approx 1200mm centre to centre with GI cleat and steel expansion fasteners, including drilling holes for 4mm dia GI wire suspender and clips etc complete as per manufacturer's recommendations complete all as specified and directed. Note:- (i) Ceiling boards shall be measured separately. (ii) The grid system shall be as per specifications of make as specified and directed.
M&L for 4mm thick non-asbestos designer fiber cement building boards of size 595x595x6mm fixed or laid/inserted to GI frame work with screws/ clips as in ceiling, laid flat or sloping complete all as specified and directed. Note:- GI frame work will be measured and paid for separately.
S&F cast iron floor trap 75mm dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F grating doom100mm dia of PTMT (Min weight 25 gms) complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl of 110mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl of 75mm bore complete all as specified and directed.
S&F PVC (SWR) 'S/P' trap 110mm bore complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed in floor/wall complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls/floor complete all as specified and directed.
M&L for 40mm dia low density poly ethylene pipes (LDPE) of pressure rating 6 kg/cm, laid in trenches complete all as specified and directed.
S&F bottle trap 7''/12'' as required complete all as specified and directed. Make:- Prayag Cat No. BEA-21or equivalent.
M&L for 32mm dia low density poly ethylene pipes (LDPE) of pressure rating 6 kg/cm, laid in trenches complete all as specified and directed.
S&F overhead shower with 150mm long arm (with flange) complete all as specified and directed. Make:- Prayag cat No. BOS-11, BOS 48(Arm) or equivalent.
S&F bib cock 2-way, double handle with flange complete all as specified and directed. Make:- Prayag cat No.: 8312 or equivalent.
S&F wall mixer with bend (for overhead shower) for mixing hot & cold water, screwed down for iron pipe and fixed complete all as specified and directed. Make:- Prayag cat No.: 7375 or equivalent.
S&F health faucet with 1 mtr tube and hook complete all as specified and directed. Make:- Prayag cat No.: BEA-81 or equivalent.
S&F towel rail 600mm long complete all as specified and directed. Make:- Prayag cat No.: BA-20 or equivalent.
S&F towel ring complete all as specified and directed. Make:- Prayag cat No.: BA-21 or equivalent.
S&F toilet paper holder complete all as specified and directed. Make:- Prayag cat No.: BA-08 or equivalent.
S&F glass shelf 500x125mm (with brass brackets) complete all as specified and directed. Make:- Prayag cat No.: BEA-45 or equivalent.
S&F corner glass shelf (with brass brackets) of size 300x600mm complete all as specified and directed. Make:- Prayag cat No.: BEA-44 or equivalent.
S&F wall mixer with bend (for overhead shower) for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. Make:- Essco by Jaquar, Cat No.: APR-101273 or equivalent.
S&F 125mm dia overhead shower, round shape, single flow (ABS Body, chromium plated with grey face plate) with rubit cleaning system with arm (or with flange) complete all as specified and directed. Make:- Essco by Jaquar, Cat No.: EOS-542A or equivalent.
S&F pillar cock with extension body complete all as specified and directed. Make:- Essco by Jaquar, Cat No.: APR-101021 or equivalent.
S&F two way bib cock, wall flange complete all as specified and directed. Make:- Essco by Jaquar, Cat No.: DLX-512ANKN or equivalent.
S&F angle cock complete all as specified and directed. Make:- Essco by Jaquar, Cat No.: MQT-526KN or equivalent.
S&F hand shower (health faucet) (ABS Body) with 1 mtr long easy flex tube in chrome finish and wall hook complete all as specified and directed. Make:- Essco by Jaquar, Cat No.: ALE-ESS-585 or equivalent.
S&F toilet paper holder complete all as specified and directed. Make:- Essco by Jaquar, Cat No.: AEC-1151 or equivalent.
S&F vitrous china wash basin, of size 475x360x130mm, table top type, fixed in granite or table complete all as specified and directed. Make:- Essco by Jaquar, Cat No.: AIS-WHT-101901 or equivalent.
S&F 32mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in any position complete all as specified and directed.
S&F rotational moulded polyethlene water storage tanks of 2000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F 20mm dia ball brass valve, high pressure with polythene float and fly nut, screwed for iron pipe complete all as specified and directed.
S&F vitreous china urinals, half stall type, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed.
S&F 15mm bore urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Minimum weight 60gms) complete all as specified and directed.
S&F tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specidfied and directed.
S&F towel ring of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleats (Minimum weight 90gms) complete all as specified and directed.
M&L for 35mm thick providing precast cement concrete 1:2:4 type B-0, (using 12.50mm graded stone aggregate) as in louvers and jallis including all mouldings complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channels 30cm inner girth in cement concrete using extra cement including forms, moulds mitred/ stopped ends etc complete all as specified and directed.
M&L for provision of water proofing treatment by using APP torch on fibre glass base finished membreance over roof and vertical surfaces including preparation of surfaces and applying oil based bituminous primer coat @0.30 ltr per sqm on clean and dry surface with 3 mm thick and weight not less than 3.00 Kg/Sqm and finished on top with mineral / slate finished torch on system laid with 100 mm and 150 mm over lap on side and end laps respectively all as per manufacturers instructions over and including rendering 10mm thick in cement mortar 1:4 with water proofing compound on concrete surfaces complete all as specified and directed.
S&F 100mm bore cast iron pipe (sand cast) as in soil, waste and vent pipe, in any length with or without ears, with cement joints fixed to walls with mild steel work as in small articles such as stack clamps, flat iron, stays, including bolts and nuts and securing ends of stays to wall complete all as specified and directed.
S&F 75mm bore cast iron pipe (sand cast) as in soil waste and vent pipe, in any length with or without, with cement joints, fixed to wall with mild steel work as in small articles such as stack clamps, flat iron, stays, including bolts and nuts and securing ends of stays to wall complete all as specified and directed.
S&F 100mm dia cast iron bend (any radius) diminishing pieces or tapers and match with existing surfaces complete all as specified and directed.
S&F 75mm dia cast iron bend (any radius) diminishing pieces or tapers and match with existing surfaces complete all as specified and directed.
S&F CI branch pieces, single (equal or unequal) ordinary or inverted (Spigot or socket tyes) or with parellel branches, 100mm bore fitted with oval access door including taking down existing & making good to match with existing surfaces complete all as specified and directed.
M&L for 100mm CI sanitary short connection pipe of length upto 300mm complete all as specified and directed.
S&F vitreous china squatting pan "Orrissa pattern" of size 580 x 440mm, white, with intregal foot rests, with & including P or S trap (excluding material & labour for flushing cistern and flush pipe) including connection to trap and to flush pipe etc including making good to floor complete all as specified and directed.
S&F vitreous china urinal plate partition of size 310 x 770mm complete with fixing arrangements complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/ loose soil complete all as specified and directed.
Removing excavated material (soil) not exc 50m and deposited where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for point wiring 1100 volt grade single core FRLSH PVC insulated & unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marking medium grade concealed in wall/ceilling including FRLSH PVC insulated unsheathed earth wire with copper conductor of size 1.50 sqmm pressed steel terminal modular boxes sunk on wall for mounting of switches switch sockets fan regulator etc including modular white cover plate suitable for mounting modular switches, sockets, fan regulator etc complete all as specified and making good to distrubed surfaces for one light point controlled by one, one way switch. Note: Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, cieling roses and holders shall be connected to common earth dolly.
All as per item No 142 above but one ceiling /exhaust/ wall mounted fan point controlled by one switch and regulator complete all as specified and directed.
All as per item No 142 above but one 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
All as per item No 142 above but one 3 pin 5 amp socket out point on independent board complete all as specified and directed.
All as per item No 142 above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and directed.
M&L for sub main wiring with 1100 volt grade two single core FRLSH PVC insulated unsheathed stranded copper conductor cable 2x4 sqmm with and inculding 1x4 sqmm copper conductor earth continuity wire drawing in and including electrical grade non metallic rigid PVC conduit with IS-9537 (Part-III) 1983 marked of suitable size, conealed in wall / ceiling as per site rquirement complete all as specified and directed.
S&F switch, modular type, single pole, one way, 6 amp, 1 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F switch, modular type, single pole, one way, 16 amp,1 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F socket, modular type, single pole, one way, 6 amp, 2 module, 2/3 pin, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F socket, modular type, single pole, one way, 6/16 amp, 2/3 pin, 3 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F ceiling rose, surface type, 2/3 terminal, 5 amps complete all as specified and directed.
S&F highly durable surface mounted 9/10 watts LED batten/ surface constructed of fire retardant engineering grade extruded plastic and decorative end cap complete with tube rod,driver including 3 core 1.0 sqmm copper conductor cable for connection and accessories complete all as specified and directed. Make:- Philips Cat part No Slim line 9W / CG Cat part No LCTLN-09-CDL / Surya Cat part No SLW BT 10W.
S&F highly durable surface mounted 18/20 watts LED batten/ surface constructed of fire retardant engineering grade extruded plastic and decorative end cap complete with tube rod, driver including 3 core 1.0 sqmm copper conductor cable for connection and accessories complete all as specified and directed.
S&F 18-22 Watt LED tube light fittings with aluminium body complete including rod with not less than 2000 Lumen output and input rated voltage 240V connecting with 2 core 1 sqmm copper conductor cable complete all as specified and directed. Make:- Philips Astra Line 20W / CG LCTLN-18-CDL / BAJAJ - BCLSB-18 WH
S&F building security light LED 20-30W with lumen output 2000 with driver with rated voltage 240V, 50Hz including mounting GI, made out of 25mm dia light grade pipe 1.2m bent to shape including FI clamps nut bolts etc complete all as specified and directed. Make:- Philips BRP020, Luker LST24 WH, CG LSTS-25-CDL
S&F sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
S&F MCB single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240V, rupturing capacity 10 KA, series 'C' complete all as specified and directed.
S&F MCB single pole 240 volt, 6 to 40 amps, 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F MCB single pole and neutral 240 volt, 6 to 40 amps, 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F isolator / MCB, single pole & neutral, 240 volts, 6 to 40 amps, 10 KA complete all as specified and directed.
S&F exhaust fan, single phase, 200/230/300mm sweep, PVC body with shutters, bolts, nuts, washers and connected electrically complete all as specified and as directed.
M&L for earthing complete with galvanised steet earth plate electrode 600 x 600 x 6mm thick burried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr below the normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts nuts check nuts & washer of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for:- (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm. (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminium lugs etc all as specified. (e) 15mm nominal bore meduim grade GI protection pipe upto 7.50 metre long for protection of earthing lead. (f) Reguisite quantity of charcoal and common salt. (g) Connection to earthing test point and testing on completion.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying of cable, poles and stay foundation and getting out in any type of soil complete all as specified and directed.
S&F double wall corrugated high dencity polymer ethyl (HDEP) pipe for laying of electric cable of size 50mm outer dia and 38mm inner dia with IS-14930 (Part 2) 2001 and 6mm thickness, laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
S&F double wall corrugated high dencity polymer ethyl (HDEP) pipe for laying of electric cable of size 63mm outer dia and 50mm inner dia with IS-14930 (Part 2) 2001 and 6mm thickness, laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade, laid in trenches, passing through pipes/ducts including testing of cross sectional area 2 core 10 sqmm complete all as specified and directed.
Supply and laid in trenches 20mm bore GI tubing, medium grade with all fittings and accessories complete all as specified and directed.
Supply and laid in trenches 25mm bore GI tubing, medium grade with all fittings and accessories complete all as specified and directed.
M&L for cutting existing steel tubing for alteration or addition of 25mm dia with tee complete all as specified and directed.
khushal constructions
Rajapriyaconstruction
Bidder Name
khushal constructions
M/s Rahul Traders
Rajapriyaconstruction
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .