| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 CrAccepted-AOC | ₹3.3 Cr | L1 | Accepted-AOC Being Lowest and reasonable tender |
| 2 | L2₹3.6 Cr+₹33.6 L (10.2%)Rejected-Finance | ₹3.6 Cr+₹33.6 L (10.2%) | L2 | Rejected-Finance Being not Lowest |
| 3 | L3₹3.8 Cr+₹49.1 L (14.9%)Rejected-Finance NO157 14 13TH B MAIN ROAD 1ST STAGE 1ST PHASE GOKULA BANGALORE 560054 | BENGALURU URBAN | KARNATAKA | 560054 | ₹3.8 Cr+₹49.1 L (14.9%) | L3 | Rejected-Finance Being not Lowest |
| 4 | L4₹3.8 Cr+₹52.0 L (15.8%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹3.8 Cr+₹52.0 L (15.8%) | L4 | Rejected-Finance Being not Lowest |
| 5 | L5₹3.9 Cr+₹58.8 L (17.8%)Rejected-Finance NO 28 4TH A CROSS 1ST MAIN ROAD ATTUR LAYOUT YELAHANKA NEW TOWN BANGALORE 560064 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560064 | ₹3.9 Cr+₹58.8 L (17.8%) | L5 | Rejected-Finance Being not Lowest |
Tender Value
₹4.0 Cr
EMD Value
₹4.8 L
Closing Date
18 Sept 2020, 6:00 pmClosed
Chief Engineer Chennai zone
Island Grounds Chennai 600 009
ADDN ALTN UPGRADATION TO CERTAIN MD ACCN OF OFFRS, JCO S AND ORs IN DOMLUR, VANNARPET AND KORAMANGALA AREA UNDER GE CENTRAL BANGALORE
2020_MES_368220_1
88525/E8
Open Tender
Civil Works
Item Rate
420 days
Bangalore
As per NIT
7 documents required · 7 mandatory
₹2,000
Yes
GE Central Bangalore
₹4.8 L
Yes
21 Oct 2020
11 Aug 2020
25 Sept 2020
11 Aug 2020
18 Sept 2020
6 Sept 2020
Amount
Taking down cement plaster on brick or stone wall or ceiling concrete etc. including racking out joints hacking for key scrubbing down with water etc., complete removal of debris outside MD land all as specified and directed.
Raking out joints / pointing built in cement mortar to squared rubble masonry wall, coursed or uncoursed all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing, rubbish off the premises all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thick, (below or above GL) as in plinth protection / Path/ hard standing / floor etc) complete removal of debris outside Md land all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for roof / chajja padding complete removal of debris outside Md land all as specified and directed.
Demolition of reinforced cement concrete of any description and size and in any position including cutting of reinforcement as required complete removal of debris outside MD land all as specified and directed.
Demolition of stone slab of any description and any thickness in floors / walls laid, bedded and pointed in any mortar complete removal of debris outside MD land all as specified and directed.
Demolition of brick work or PCC solid block masonry built in cement mortar pillars, etc. in any position below or above ground level all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping cleand and washing down with water to remove dust etc all as directed.
Taking down chowkhat with shutters (without taking off shutters from the frame) area not exc 1.5 Sqm each all as specified and directed.
Taking down chowkhat with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n exc 4 Sqm each all as specified and directed.
Taking down chowkhat with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n exc 4 Sqm each and refixing in the same opening all as specified and directed.
Taking down shutters of any description n exc 1 sqm each all as specified and directed.
Taking down shutters of any description area exc 1 sqm and n.exc 2 sqm each all as specified and directed.
Taking down shutters of any description area exc 1 sqm and n.exc 2 sqm each easying, adjusting and refixing in the same opening all as specified and directed.
M&L for post constructional ATT along the external wall / perimeter (below concrete) of building at the rate of 2.25 litre of emulsion per linear metre including drilling hole and plugging hole with cement mortar 1:2 complete all as specified and directed.
M&L for hard core with broken stone or boulders of gauge n.exc 63mm, deposited, spread, levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces all as specified and directed.
M&L for PCC 1:3:6 type C2, (using 40 mm graded aggregate) 75 mm thick as plinth protection, hard standing etc complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8, type D2, (using 40mm graded stone aggregate) as in sub floors, sub bases, floors & pavings, complete all as specified and as directed.
M&L for 20 mm thick PCC 1:2:4, type B0 (using 12.5 mm graded stone aggregate), as in RCC roof / Floor surface with mixing of water proofing compound 2% by the weight of cement to horizontal or vertical surfaces finished cement concrete surface even and smooth including necessary form work complete all as specified and directed. Note: supply only WPC shall be measured and paid separately
M&L for coloured non skid matt finished ceramic tiles, 8 to 10mm thick area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, in floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigments to match the shade of the tile laid over and including 20mm thick screed bed in cement mortar 1:4 all as specified and directed.
M&L for coloured non skid matt finished ceramic tiles, 7 to 8mm thick area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigments to match the shade of the tile laid over and including 10mm thick screed bed in cement mortar 1:3 all as specified and directed.
M&L for coloured non skid matt finished ceramic tiles, 7 to 8mm thick area of each tile exc 0.06 Sqm but not exc 0.11 Sqm, in floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigments to match the shade of the tile laid over and including 15mm thick screed bed in cement mortar 1:4 all as specified and directed.
M&L for coloured glazed ceramic tiles 300mm x 200mm x 7mm thick on vertical surfaces such as skirting, dados etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces with and including 10mm thick backing coat in CM 1:3 all as specified and directed.
M&L for double charged, Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry as specified and pointed in white or coloured pigment to match with the colour of the tile, laid over and including 20mm thick screed bed in cement mortar 1:4 all as specified and directed.
M&L for double charged, Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces such as skiring / dado etc etc. set and jointed in neat cement slurry as specified and pointed in white or coloured pigment to match with the colour of the tile, laid over and including 10mm thick screed bed in cement mortar 1:3 all as specified and directed.
M&L for 22-25mm thick Granite work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 20mm thick screed bed in cement mortar 1:3 all as specified and directed. Notes: 1. All exosed edges shall be provided half around edge. 2. Slab shall be in single piece
M&L for 18-20mm thick sadarhalli stone slab in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 20mm thick screed bed in cement mortar 1:3 all as specified and directed.
M&L for machine cut Kota stone slab, 20-25mm thick, as in flooring, laid and jointed with neat slurry and pointed with grey cement slurry mixed with pigment to match the shade of the slab including bull nosing the edges, rubbing and polishing complete with and including 20mm thick screed bed in cement mortar 1:3 all as specified and directed. Notes: 1. Slab shall be in single piece for treads and raisers
M&L for machine cut Kota stone slab, 20-25mm thick, as in risers of steps, skirting, dado, cladding to pillars, etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including bull nosing the edges, rubbing and polishing complete with and including 10mm thick backing coat in CM 1:3 all as specified and directed.
M&L for stone masonry walling of square rubble regular coursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 all as specified and as directed.
Material and Labour for precast cement concrete block masonry with solid blocks exceeding 10cm in width, of grade C5 all as per IS 2185 - 1979, having minimum average compressive strength 5 N/sqmm at 28 days and density not less than 1800 kg/cum, set in CM 1:6 all as specified and directed.
Material and Labour for precast cement concrete block masonry with solid blocks, 10cm in width, of grade C5 all as per IS 2185 - 1979, having minimum average compressive strength 5 N/sqmm at 28 days and density not less than 1800 kg/cum, set in CM 1:4 all as specified and directed.
M&L for rendering 5mm thick in cement mortar 1:3 on soffit of roof ceiling, finished fair and even without using extra cement complete all as directed.all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for Dubbing out average 20mm thick in CM 1:6 on irregular face of walls complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for keyed pointing to random or polygonal rubble masonry wall, uncoursed or brought up to course in CM1:3 all as specified
Cutting/chipping the spalling concrete surfaces of columns, beams, facias, slabs, Chajjas & cantilevers etc., and trimming, cleaning the surfaces of any thickness and Material and labour for applying epoxy treatment for bonding old demolished concrete surfaces including application of one coat of notozinc primer to the exposed reinforcement and over plastering in CM 1:4 average 20mm thick finishied even and smooth without using extra cement to level the surface etc including necessary scaffolding as required at site complete all as specified and directed
M&L for 2nd class hard wood chowkat or frames, plain, solid, wrought, framed and rebated on the solid rounded or chamfered, put together with glue pinned at joints, fixed in position all as specified and directed.
M&L for PCC 1:2:4 type B0, (using 12.5 mm graded aggregate) as in filling of pressed steel chowkats complete all as specified and directed.
M&L for plain cement concrete 1:5:10 type E2, (using 40mm graded stone aggregate) as in filling and mass concrete in sunken floors all as specified and directed.
M & L for pressed steel frames of size 125 x 60 mm, made out of 1.25mm mild steel sheets for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete, as specified, supplied and fixed all as directed.
Supply & fix pressed steel frames for doors with one or more rebates including necessary fitting lugs, hinges, lock strike plates etc completed size of frame 105x60mm made out of 1.25mm mild steel sheets complete all as specified & directed.
M&L for 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, decorative teak veneered facing on both sides with lipping/ framing to match, fitted to chowkats all as specified and as directed.
S&F Box type Steel Windows/Ventilators double side shutters (Windows side hung type, Ventilators top hung) pressed steel frames made out Cold rolled mild steel Sheet of 80x60x1.25mm double rebated, Shutters box type made out of Cold rolled mild steel Sheet of 40x20x1.0mm , windows & ventilator shutter fixed made of glass and gauge fixed with box type hinges, Aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, telescopic stays, etc complete all as specified incl 12mm square guard bars/grill welded with steel frame (100c/c horizontically) all as specified and directed by Engineer-in-Charge.
Notes :- (i) The contractor's quoted rate shall be deemed to the cost of combined for steel frames, steel shutters, grill / guard bars, beading, fittings suchs as handles, hinges, Telescopic stays, locking arrangements and fixing of glass and wiremesh etc.
(ii) Supply and fixing 4 mm thick sheet / pin head glass and stainless steel wire mesh shall be measured and paid separately.
(iii) All Windows/Ventilator design as per CECZ TD drg No 539 Sheet 1 / 3 to 3/ 3
S&F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe-290 Gde- E-165, fixed in repairs, all as specified and as directed.
M&L for solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelaminated PVC sheet on both sides reinforced with M.S. Square tube, supplying and fixing in opening as per specification and drawing all as specified and as directed.
M&L for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded prelaminated PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of prelaminated PVC sheets on both sides to be fitted in the M.S. frame welded / sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing all as specified and directed Note: The quoted rate shall be inclusive of all builder's hardware as per manufacturer's instructions.
M&L for pre-laminated particle board, exterior grade, 18/19mm thick, pre-laminated both side with decorative choice lamination and 6mm thick teak wood edging of all around all as specified and directed by Engr-in-charge.
supply and fixing 4mm thick sheet glass ordinary quality and glazing in square n. exc 0.5 sqm in each pane all as specified and as directed.
Supply and fixing 4mm thick figured glass pin head type ordinary quality and glazing in square n. exc 0.5 sqm in each pane all as specified and as directed.
Supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40mm fixed in panel of joinery with stainless steel wire staples all as specified and as directed.
S&F MS butt hinges 50mm in size, medium weight, cold rolled all as specified and directed.
S&F MS butt hinges 75mm in size, medium weight, cold rolled all as specified and directed.
S&F MS butt hinges 100mm in size, medium weight, cold rolled all as specified and directed.
S&F aluminium anodised barrel tower bolt 100mm long all as specified and directed.
S&F aluminium anodised barrel tower bolt 150mm long all as specified and directed.
S&F extruded aluminium alloy handles, 100mm in size, fabricated type, anodised all as specified and directed.
S&F aluminium handle, Cast type, anodised 150 mm in size all as specified and directed.
S&F 300mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts plate type with bright bolt not less than 12mm dia all as specified and directed.
S&F 100mm long mild steel hasp and staple, wire type, stove enamelled black including bolt to hinge plate fixed with screws complete all as specified and as directed.
S&F 40mm flaps width (when open) continuous (Piano) hinges mild steel bright finish or electro galvanised all as specified.
S&F Mortice lock, brass, vertical type, 4 levers, size 65mm, all as specified and directed.
S&F 15mm dia brass Magic Eye all as directed.
S&F "in repair" 25 mm dia aluminium anodised decorative type curtain rods all as specified and as directed.
S&F "in repair" decorative type curtain rod brackets suitable for 25mm dia aluminium anodised decorative type rod all as specified and as directed.
M&L for cutting holes with depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall exc. half brick but not exc. one brick in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required
M&L for mild steel works as in bands, straps, supports or stays for rainwater , ventilating pipes, including bolts, if required; hooks (stay), heavy for large gates, hook and pintle hinges; large hasps and staples; chains,hand made sliding bolts; clamps; hold fasts; wall ties, hooks for handing fans, plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar articles confirming to Fe-290 Gde-E-165, all as specified and as directed.
M&L for 1000 litres capacity rotational moulded polyethylene (HDPE) water storage tanks, 'ISI' marked, cylindrical, vertical with closed top conforming to IS 12701-1989 having two layers wall construction with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position including testing and dismantling of existing water tank , 25mm PVC ball valves, 25mm tank adopter, 25mm union, 25mm gate galves complete all as specified and directed.
All as per item No. 72 hereinbeofre but for 750 litres capacity rotational moulded polyethylene (HDPE) water storage tanks
Taking up or down existing unserviceable 20mm bore GI tubes of any grade all as specified and directed.
S&F 20mm (outer dia) CPVC pipes (ISI Marked) SDR 11 & CPVC SDR 11 fittings, fixed complete to walls, ceilings or laid in floors all as specified and directed.
S&F "in repair" 1mm thick stainless steel sink with drain board , overall size 940x460x203mm, bowl size 405x354x203mm, with plug, washers, waste pipe & waste coupling including bedding in cement mortar, fixing cantilever brackets & connecting union to pipe including waste fittings, brass, chromium plated 40mm fixed on brick / PCC block walling complete all as specified and as directed. Make: Prayag Cat No. 1240D or equivalent models in cera / Nirali / Bluestar
S&F "in repair" 1mm thick stainless steel sink, overall size 430x510x203mm, bowl size 430x380x203mm, with plug, washers, waste pipe & waste coupling including bedding in cement mortar, fixing cantilever brackets & connecting union to pipe including waste fittings, brass, chromium plated 40mm fixed on brick / PCC block walling complete all as specified and as directed. Make: Prayag Cat No. 1218D or equivalent models in cera / Nirali / Bluestar
S&F "in repairs" Stainless steel plate rack of size 787.40x914.40x254mm made out of 1mm thick steel sheet including fixing with rawl plug and screws on walls all as specified and as directed. Make: Prayag Cat No. P348 or equivalent models in cera / Nirali / Bluestar
S&F "in repairs" Stainless steel plate rack of size 787.40x762.00x254mm made out of 1mm thick steel sheet including fixing with rawl plug and screws on walls all as specified and as directed. Make: Prayag Cat No. P346 or equivalent models in cera / Nirali / Bluestar
S&F "in repairs" Vitreous China Wash Hand Basin, size 550 X 400 mm with pedestal Ivory or superior colour, 1105mm long, including 32mm dia Brass Chromium Plated Waste Fitting and PVC connection pipe of 15mm x 600mm long, including suitable fixing arrangement,cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed. Make: Cera Cat No. S2040103 for wash basin & S2090101 for pedastal or equivalent models in Parryware/ Hindware / Jaquar
S&F "in repairs" Vitreous China Wash Hand Basins, size 550 X 400 mm (Flat Back or Angle Back type) including Pillar Taps 15mm Bore Cast Copper Alloy with Capstan Heads, Chromium Plated, fancy type, 32mm dia Brass Chromium Plated Waste Fitting and PVC connection pipe of 15mm x 600mm long, a Pair of Angle iron Brackets duly Painted/Erecting Stand including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed Make: Cera Cat No. S2040103 for wash basin or equivalent models in Parryware/ Hindware / Jaquar / Prayag
S & F "in repairs" vitreous china wash down water closet (Padestal Pattern) ivory colour (excluding flushing cistern and flush pipe) including PVC seat cover white closed pattern with recessed bottom and connection to drain or out going pipe and flushing pipe all as specified and as directed. Make: Cera Cat No. S1050109 & B1520102 or equivalent models in Parryware/ Hindware / Jaquar / Prayag
S&F "in repair" Vitreous china squatting Pan 'Orrisa' Pattern size 580 x 440 mm white colour with integral foot rest , P or S Trap, and lime concrete bedding complete making good disturb ground all as specified and as directed. Make: Cera Cat No.S3010106 (clovis) or equivalent models in Parryware/ Hindware / Jaquar / Prayag
S&F "in repairs" syphonic action type low level PVC flushing cistern, 10 litres capacity, white colour, with inlet, ball valve, float, handle and flush pipe etc fixing in position with PVC connection pipe of 15mm x 600mm long etc complete all as specified and directed. Make: Cera Cat No.B1010102 (Ciena) or equivalent models in Parryware/ Hindware / Jaquar / Prayag
Taking down damaged bathroom cabinet of any type and S&F New PVC bathroom cabinet best quality of size 400x500mm all as directed. Note: Prayag Cat No. 554 or equivalent model in Parryware
S&F 15mm bore brass CP basin centre hole mixer with long bend for mixing hot and cold water screwed down for iron pipe all as specified and directed Make:- HT Cera Cat No. F3001461 or equivalent model in Parryware / Jaquar / Prayag
S&F 15mm bore brass CP wall mixer for mixing hot and cold water screwed down with provision of over lead shower and cock for iron pipe and fixed complete all as specified. Make:- Cera Cat No - HT F3001401 or equivalent model in Parryware / Jaquar / Prayag
S&F "in repairs" 15mm Bib taps chromium plated fancy type cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for union all as specified and as directed. Make: Cera Cat No - HT F3001152 or equivalent model in Parryware / Jaquar / Prayag
S&F 2 in 1 CP 15mm Bib taps Quarter turn fancy type with crutch or butterfly handle screwed down, screwed for iron pipe or for union all as specified and as directed. Make : Cera cat No. HT F 3001163 or equivalent model in Parryware / Johnson / Jaquar
S&F "in repairs" Stop valve/Angle stop valve, 15 mm bore, cast copper alloy chromium plated fancy type with long shank and cup concealed type complete all as specified and as directed. Make Cera cat No. HT F3001201 or equivalent models in Parryware / Johnson / Jaquar
S&F "in repairs" Brass chromiun plated tubular towel rail, 20mm dia ‘D’ type, 60cm long between flanges all as specified and as directed. Make : Cera cat No. F 5006103 or equivalent model in Parryware / Johnson / Jaquar
S&F "in repairs" Shower rose with brass chromium plated shower rose with or without swivel joints, 100mm size including fixing to steel pipe or union all as directed. Make: Cera Cat No-F7020304 or equivalent models in Parryware / Johnson / Jaquar
S&F Towel ring with chromium plated fancy type all as directed. Make: Cera Cat No- F5002105 or equivalent models in Parryware / Johnson / Jaquar
S&F Health faucet CP, with connecting PVC pipe 1 Meter long with stand all as directed. Make: Cera F8030103 or equivalent models in Parryware / Johnson / Jaquar
M&L for Treatment of soil and existing floors using emulsion @ 1 litre per hole, 300mm apart including drilling and plugging 12mm dia holes with CM1:2 to match with existing floors all as directed
S&F "in repairs" CP Soap dish 150mm, fixed to wall with chromium plated brass screws all as directed. Make: Parryware / Hindware / Johnson / Jaquar
S&F "in repairs" toilet paper holder chromium plated all as directed. Make: Cera Cat No. F5003110 or equivalent models in Parryware / Johnson / Jaquar / Hindware
M &L for providing PVC (SWR) floor trap , plain, 75mm dia outlet, with steel grating including jointing with solvent cement etc complete fixed in repairs
S&F "in repairs" 110mm bore UPVC (SWR) pipes, type B, single socketed, ISI marked, in any length with rubber ring joints fixed to walls all as specified and directed
S&F "in repairs" 75mm bore UPVC (SWR) pipes, type B, single socketed, ISI marked, in any length with rubber ring joints fixed to walls all as specified and directed
S&F 110mm bore UPVC (SWR) bends any radius with access door all as specified and directed.
S&F 75mm bore UPVC (SWR) bends any radius with access door all as specified and directed.
S&F UPVC (SWR) junction single,(Single T) 110mm dia equal or unequal with access door all as directed.
S&F UPVC (SWR) junction single,(Single T) 75mm dia equal or unequal with access door all as directed.
S&F UPVC (SWR) branch piece, (Single Y) 110mm dia equal or unequal with access door all as directed.
S&F UPVC (SWR) branch piece, (Single Y) 75mm dia equal or unequal with access door all as directed.
S&F 110mm bore UPVC (SWR) vent cowl all as specified and directed.
M&L for preparation of new surfaces of wall and applying two coats of oil bound distemper over a coat of chalk whiting priming coat over 3mm thick layer of birla wall care putty all as specified and as directed.
M&L for preparation of new surfaces of wall and applying two coats of oil bound distemper over a coat of chalk whiting priming coat all as specified and as directed.
M&L for preparation of new surfaces of ceiling and applying two coats of oil bound distemper over a coat of chalk whiting priming coat all as specified and as directed.
M&L for preparation of new surfaces of wall and applying two coats of cement based paint all as specified and as directed.
M&L for three coats of white wash on newly plastered surfaces of wall including necessary preparation of surfaces all as specified and as directed.
Complete removal of existing treatment and preparation of surface of wall, washing, rubbing down and stopping of distempered and painted surface, applying a coat Birla wall care putty of 3mm thick for smooth finished of the surface and applying two coat of oil bound distemper all as specified and directed.
Complete removal of existing treatment and preparation of surface of ceiling, washing, rubbing down and stopping of distempered and painted surface, applying two coat of oil bound distemper all as specified and directed
M&L for preparation of old decorated surface and applying two coat of white wash on Walls etc complete and as directed.
M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
M&L for one coat of synthetic enamel paint on old painted wooden surfaces of any description over 10cm width or girth including necessary preparation of surfaces all as specified and as directed.
M&L for one coat of synthetic enamel paint on old painted steel surfaces of any description over 10cm width or girth including necessary preparation of surfaces all as specified and as directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm grades stone aggregate) as in padding over roof / chajja 25mm thickness finished even and smooth without using extra cement all as directed.
M&L for rendering 10mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement including mixed with WPC complete all as directed. Note : Supply only WPC shall be measured and paid separately
M&L for applying oil bound bitumen primer of grade VG 10 @ 1.50 Kg/Sqm and providing 3 mm thick APP modified water proofing membrane weighing not less than 3.6 kg/sqm reinforced with non woven polyester matt weighing not less than 150 gm /sqm having softening point not less than 140 centigrate, having tensile strength of 650 N/sqm and 350 N/sqm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap, applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 Kg /Sqm top of membrane surface shall then be finished with solar reflective bituminious aluminium paint @ 0.10 Kg/Sqm complete all as specified and directed.
NOTE: (i) APP modified water proofing membrane shall be of any one of the approved makes as specified here-in-after and shall conform to specifications given IS 16540-2017/ IS 16532-2017. (ii) Contractor shall produce necessary test certificate of the manufacturer to the Engineer-in-charge before incorporation in the work. (iii) Necessary independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work. (iv) The work shall be executed through authorised applicators of original manufacuturer only.
M & L for Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry with grey cement and pigment in floors, cut and polished over and including 20 mm thick screed bed cement mortar (1:3) complete all as specified and directed.
Supply only approved integral water proofing compound all as specified and as directed.
M&L for mild steel TMT bars of 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia all as specified and directed.
M&L for mild steel TMT bars of 8mm dia cut to length bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia all as specified and directed.
M&L for providing RCC precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in cover slabs, etc. set in CM 1:6 all as specified and directed.
M&L for reinforced cement concrete 1:2:4, Type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves and the like all as specified and directed.
M&L for use of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200m thick (Horizontal or sloping), flat fair finished surfaces of concrete all as specified and directed.
M&L for use of form work to edges of concrete flats, treads, bands and similar works, for fair finished concrete surfaces, horizontal or sloping, exceeding 5cm but not exceeding 10cm wide all as specified and directed.
S & F PVC Cap Hand Rails of width 40mm complete all as specified and as directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m depth and getting out in hard/ dense soil for foundation of man holes / sewage lines / pipes, etc. all as specified and directed.
Demolition & breaking of salt glazed stone ware drain pipes including benching/ PCC of 100mm dia pipes complete all as specified.
M&L for plain cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as in foundation and mass concrete all as specified and directed.
M&L plain cement concrete 1:3:6, type C-1, (using 20mm graded stone aggregate) as in coping, bed blocks, eves filling between wall and tile/ sheet roofing including necessary form work all as specified and directed
M&L for bed concrete to 100mm bore pipes in Plain Cement Concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) including packing under and haunching against the sides of pipe after they are laid and tested all as specified and directed.
Material and labour for Reinforced concrete pipes dia 100mm, class NP3, laid and jointed complete with collars complete all as directed.
Returning filling in with approved excavated soil including spreading levelling, watering and well ramming in layers n. exc. 25 cm thick in hard / dense soil all as specified and directed.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point in any type of soil all as specified and directed.
S & F 300 mm ordinary rat tail rod pattern springs including roller and roller plate all as directed.
S&F "in repairs" syphonic action type high level PVC flushing cistern, 10 litres capacity, white colour, with inlet, ball valve, float, handle and flush pipe etc fixing in position with PVC connection pipe of 15mm x 600mm long etc complete all as specified and directed. Make: Cera / Parryware/ Hindware / Jaquar / Prayag
Supply & fix 150mm long stainless steel bright finish handle for cabinet shutter all as directed.
S&F locks, drawer grade I, 65 mm size, 4 lever, brass all as directed.
M&L ball catches with 8mm dia steel ball and brass body and striking plate including letting in, complete all as directed.
S&F "in repair" CP Roller to Sliding Glass all as directed.
S&F "in repair" 250mm long MS Hinges for Study table folding type approved make and design all as directed.
S&F 6mm thick MDF Board one side finished as in wardrobe no of compartments & Drawers all as specified and as directed by Engineer-in-Charge.
S&F 19mm thick MDF Board medium density with one side melamine and other balancing white as in wardrobe no of compartments & Drawers all as specified and as directed by Engineer-in-Charge.
M&L for 2nd class hard wood Plain fillets of size not exc 3 sq.cm, square, rectangular or triangular in section, clean sawn, secured with nails or brads all as directed.
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M &L Rendering 15mm thick on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing in CM 1:3 with mixing of water proofing compound and finished even and smooth without using extra cement all as directed. Note : Supply Water proofing compound measured seperately.
M&L Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat for sunken floor treatment all as specified and directed.
M&L for coloured glazed ceramic tiles 600x300x10mm thick on vertical surfaces such as skirting, dados etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces including 10mm thick backing coat in CM 1:3 all as specified and directed.
S&F "in repair" 20mm dia Gun Metal Gate valves with iron wheel head screwed both ends for iron pipes all as specified and as directed.
S&F "in repair" Bib Tap Sink Cock with flange 15 mm bore all as directed. Make:- Prayag Cat no 8316 or equivalent model in Parryware / Johnson / Hindware
S&F 40mm bore Galvanised steel spout, medium grade all as specified and directed.
S&F "in repair" Chromium Plated Steel Grating of 100mm size With or Without Waste Hole all as specified and as directed.
M & L for forming expansion joints (Grade 'A') 12mm wide 50mm deep joint with mastic filling of Bitumen and sand ratio of 1:2 complete all as specified and as directed.
Taking down carefully existing point wiring of light/ fan/ bell/ 5 Amps socket/ 15 Amps socket/ 2 way light point, etc. complete of any description including fittings and fixtures such as switches, sockets, call bells, ceiling roses, pendants, holders, regulators, call bells, light fittings, etc. and making good the disturbed surfaces of walls, floors, etc. all as specified and directed.
M&L for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) in and including Non metalic PVC rigid conduit medium grade with ISI mark of size 20mm dia with all accessories fixed on surface of the wall, including factory made galvanized steel pressed terminal boxes with 1.22mm thick suitable for fixing switches,sockets,fan regulators etc., alongwith earth wire to be connected to common earth dolly for one light, ceiling, exhaust, bell point controlled by one piano switch one way complete all as specified and directed.
All as described in item No. 162 but for one light point controlled by 2 two way switches
All as described in item No. 162 but for one three pin switch socket 5/6 Amps socket outlet on the same board with other switches.
All as described in item No. 162 but for one three pin switch socket 5/6 Amps outlet with indepenent board
M&L for point wiring complete all as specified with 1100 Volts grade 2.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) in and including Non metalic PVC rigid conduit medium grade with ISI mark of size 20mm dia with all accessories fixed on surface of the wall including factory made galvanized steel pressed terminal boxes with 1.22mm thick suitable for fixing 15 Amps switches,sockets and earth wire to be connected to common earth dolly all as specified and directed for 6-pin 15 Amps piano switch socket combination out let on independent board (both for power point & geyser)
M&L for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) making use of existing Non metalic PVC rigid conduit concealed in wall/ceiling /floor/roof etc, including factory made galvanized brand embosed steel pressed box not less than 1.0mm thick suitable for fixing modular switches,sockets,fan regulators etc., of suitable modules including cutting of wall and finishing the same with painting matching existing surface of wall and the earth wire to be connected to common earth dolly for one light, ceiling, / exhaust fan, bell point controlled by one switch all as specified and directed for the following:- NOTE :- The rate of Modular point is inclusive of modular metal flush box, modular white cover plate with its frame
All as described in item No. 167 but for one light point controlled by 2 two way switches
All as described in item No. 167 but for one three pin switch socket 5/6 Amps socket outlet on the same board with other switches.
All as described in item No. 167 but for one three pin switch socket 5/6 Amps outlet with indepenent board
M&L for point wiring complete all as specified with 1100 Volts grade 2.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) making use of existing Non metalic PVC rigid conduit concealed in wall/ceiling /floor/roof etc, including factory made galvanized brand embosed steel pressed box not less than 1.0mm thick suitable for fixing modular switches,sockets,fan regulators etc., of suitable modules including cutting of wall and finishing the same with painting matching existing surface of wall and the earth wire to be connected to common earth dolly all as specified and directed for both for power point & geyser NOTE : The rate of Modular point is inclusive of modular metal flush box, modular white cover plate with its frame
M&L for point wiring complete all as specified with 1100 Volts grade 4.0 Sqmm PVC insulated FRLS unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) in and including Non metalic PVC rigid conduit medium grade with ISI mark of size 20mm dia with all accessories concealed in wall/ceiling /floor/roof etc; including factory made galvanized brand embosed steel pressed box not less than 1.0mm thick suitable for fixing switches,sockets,fan regulators and earth wire to be connected to common earth dolly including cutting of wall and finishing the same with painting matching existing surface of wall all as specified and directed for AC unit
M&L for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) in and including PVC casing & caping with ISI mark of suitable size with all accessories fixed on surface of the wall including factory made galvanized steel pressed terminal boxes with 1.22mm thick suitable for fixing piano switches,sockets,fan regulators etc., alongwith earth wire to be connected to common earth dolly all as specified and directed for one light point, ceiling / exhaust fan, bell point controlled by one switch
All as described in item No. 173 but for one light point controlled by two way switches
All as described in item No. 173 but for one three pin switch socket 5/6 Amps socket outlet on the same board with other switches.
All as described in item No. 173 but for one three pin switch socket 5/6 Amps outlet with indepenent board
M&L for point wiring complete all as specified with 1100 Volts grade 2.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) in and including PVC casing & caping with ISI mark of suitable size with all accessories fixed on surface of the wall including factory made galvanized steel pressed terminal boxes with 1.22mm thick suitable for fixing switches,sockets,fan regulators and earth wire to be connected to common earth dolly all as specified and directed for 6-pin 15 Amps switch socket combination out let on independent board
M&L for point wiring complete all as specified with 1100 Volts grade 4.0 Sqmm PVC insulated FRLS unsheathed 1100 Volts with multistranded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) in and including PVC casing & caping with ISI mark of suitable size with all accessories fixed on surface of the wall including factory made galvanized steel pressed terminal boxes with 1.20mm thick suitable for fixing switches,sockets,fan regulators and earth wire to be connected to common earth dolly all as specified and directed for AC unit and geyser
S&F modular switch 1 way 6A, 1 module, 230 Volts with ISI mark all as specified and directed. Make for srl item No. 179 to 185 : Legrand / Schneider / C&S / Siemens
S&F modular switch 2 way 6A, 1 module, 230 Volts with ISI mark all as specified and directed.
S&F modular bell push 6A, 1 module, 230 Volts with ISI mark all as specified and directed.
S&F modular switch 1 way 16A, 1 module, 230 Volts with ISI mark all as specified and directed.
S&F modular socket 6 A- 2/3 pin combined, 230 Volts, 2 modules with ISI mark all as specified directed.
S&F modular socket 6/16 A- 5/6 pin combined, 230 Volts, 2 modules with ISI mark all as specified directed.
S&F modular fan regulator 5 step, high speed, 120W and above, 2 module, 230 Volts ergonomically designed directional knob with 360 degree rotation with ISI mark all as specified directed.
S&F ceiling rose surface bakelite 65 x 50mm with three terminals with ISI mark all as specified and directed.
S&F Bell ding-dong 230 V, single pole all as specified and directed.
Supply and fix Piano type 1- way switch 6 Amps 240 volts AC all as specified and directed.
Supply and fix Piano type 2- way switch 6 Amps 240 volts AC all as specified and directed.
Supply and fix Piano type Switch Socket combination,6 Amps 3- pin ,240 volts AC suitable for inserting 2 pin 6 A / 3 pin 6 Amps plug top all as specified.
Supply and fix Piano type Switch socket combination,16 Amps/5 Amps 240 volts suitable for inserting 3 pin 6 Amps / 3 pin 16 Amps plug top all as specified.
Supply and fix stepped-socket type 5 step electronic fan regulator 120 Watts 230 V. AC., 2 module, ergonomically designed directional knob with 360 degree rotation with ISI mark all as specified directed.
Supply and fix Piano type bell push switch 6 Amps 240 volts AC all as directed.
M&L for taking down the ceiling fan of any make/size/capacity installed, after neccessary electrical disconnection of single phase, 240 volts, and applying two coats of synthetic enamel painting over a coat of metallic red oxide primer & reconnecting with all fittings & accessories, testing on completion complete all as specified and directed.
Supply & fix exhaust fans heavy duty .metal body,AC single phase 230/ 240 V of size 300 mm sweep, 900 RPM with louvers and all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm , etc all as directed. Make :Havells/ Orient/Crompton Greeves Note- Quoted rate deemed to be include Opening of wall and making good the disturbed surface, colour washing matching with existing surface of wall with all neccessary fixing arrangement including nut,bolt and washers.
S&F Storage type water heater 25 Ltrs BEE 5 star rated connected with steel wired braided pipe of 15mm bore for hot/cold water including pressure release valve, safety valve etc,complete all as specified and directed Make: Racold / Venus / Havells
M&L for taking down the unserviceable storage type water heater (geyser) of any size / capacity installed whether in vertical / horizontal position, after neccessary electrical disconnection, single phase, 240 volts and replacement of ISI marked heating coil, thermo stat indicating lamps, and applying two coat of synthetic enameld painting & refixing of geyers with neccessary electrical / water connection & testing on completion complete all as specified and directed.
Supply and fix "in repairs" Hot & Cold high pressure premium heavy duty steel wired braided connection pipe of size 15mm with brass nuts and length of 600 mm with suitable of nuts& bolts making neccessary connection & testing for leakage of water complete all as specified.
Supply and fix LED batten luminaries surface mounted 4 feet system wattage of 20 Watts and not less than 2000lm with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature≥5700K, surge protection3KV in CM, IP-20 protected, meets LED IS specifications, , Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50DegreeC, system efficacy at luminarie level ≥ 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sq mm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. (Make-Philips, Wipro, Havells)
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 Watts and not less than 1000lm with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature ≥ 5700K, surge protection 2KV in CM, IP-20 protected, meets LED IS specifications, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire to fitting fixed complete all as specified and directed. (Make-Philips, Wipro, Havells)
Supply and Fix 25W High efficient LED Security light fitting around the building, Aluminium pressure Die cast housing with pure polyester powder coated for long life, High purity lenses for superior performance, IP65/66 protection, Suitable for external pipe dia Up to 50 mm, with Luminiare efficacy>100lm/W, driver Voltage range 150-270V AC, temperature range- 0 to 50DegC, Driver efficiency > 85%, Power factor > 0.95, THD<10%, CRI >70, Colour Temperature≥ 5700K, with Luminiare efficacy≥100lm/W, Surge protection from overvoltage- 2.5KV in CM, Safety Extra Low Voltage Safe level as per IEC standard, 50000 burning hours as per L70 Criteria, including provision of 40mm dia GI light grade pipe1.5 mtr length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed (Make: Wipro/Philips/ Havells)
Supply and fix MCB DB SPN 8 way, having degree of protection as per IP 43-IK 09 with metal door (double door), 240 Volts, complete with 200 Amps rated copper bus bar and neutral link with provision for MCB SPN as incomer and SP MCBs as outgoing and total number of modules equal to 8 with blanking plates etc, all as specified and directed. Make; Legrand/Havells/Siemens
S&F MCB DB SPN 12 way, having degree of protection as per IP 43-IK 09 with metal door (double door), 240 Volts, complete with 200 Amps rated copper bus bar and neutral link with provision for MCB SPN as incomer and SP MCBs as outgoing and total number of modules equal to 12 with blanking plates etc, all as specified and directed. Make; Legrand/Havells/Siemens
S&F metal plug and socket of capacity with 20 Amps SPN MCB and steel enclosure complete all as specified and as directed by Engr-inCharge. Make: Legrand/Havells/Siemens
Suppy and fix MCB SPN 63 Amps,240 Volts,10 KA, "C" series all as directed. Make: Legrand/Havells/Siemens
Suppy and fix MCB SPN 40 Amps,240 Volts,10 KA, "C" series all as directed. Make: Legrand/Havells/Siemens
S&F MCB single pole 6 Amp to 32 Amps, 240 Volt, 10 KA, 'C' series. Make; Legrand/Havells/Siemens :
M&L for sub main wiring with 2 runs of 2.5 sqmm, single core, FRLS insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in non metallic PVC grey surface conduit, medium grade, of suitable size fixed on surface of the wall with all accessories such as Tees, Elbows, junction box, reducers etc as required along with one run of 2.5 sqmm single core PVC insulated & unsheathed FRLS multi stranded copper conductor as continuous earth wire dolly and connecting to new / existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old sub main wiring and any type of conduit complete all as specified and directed..(For building security light) Note: 3 runs of 2.5sqmm single core copper cable and 1 run of non metalic PVC conduit shall be measured as single run/unit
M&L for sub main wiring with 2 runs of 4.0 sqmm, single core, FRLS insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in non metallic PVC grey surface conduit, medium grade, of suitable size fixed on surface of the wall with all accessories such as Tees, Elbows, junction box, reducers etc as required along with one run of 4.0 sqmm single core PVC insulated & unsheathed FRLS multi stranded copper conductor as continuous earth wire dolly and connecting to new / existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old sub main wiring and any type of conduit complete all as specified and directed.(For Power and Geyser) Note: 3 runs of 4.0sqmm single core copper cable and 1 run of non metalic PVC conduit shall be measured as single unit/ run.
M&L for sub main wiring with 2 runs of 10.0 sqmm, single core, FRLS insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in non metallic PVC grey surface conduit, medium grade, of suitable size fixed on surface of the wall with all accessories such as Tees, Elbows, junction box, reducers etc as required along with one run of 10.0 sqmm single core PVC insulated & unsheathed FRLS multi stranded copper conductor as continuous earth wire dolly and connecting to new / existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old sub main wiring and any type of conduit complete all as specified and directed. Note: 3 runs of 10.0sqmm single core copper cable and 1 run of non metalic PVC conduit shall be measured as single unit/run.
M&L for Sub main wiring with 2 runs of 16.0 sqmm, single core, FRLS insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing PVC / steel conduit laid in cable trench / cable alley along with one run of 16.0 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to new / existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old sub main wiring and any type of conduit complete all as specified and directed. Note: 3 runs of 16.0sqmm cable shall be measured as single run / unit
Dismantling and taking down old energy meter old from rusted / broken metering panel and Supply, Install, testing & commissioning Distribution cubical metering panel board of size 1.20x1.00x0.25metre compartment for 8-Nos single phase energy meter, indoor type vermin & rust proof, factory fabricated with CRCA sheet of 16 SWG, powder coated totally enclosed, with IP-43 Protection complete, 430 volt, 4 wire system as incoming, comprising following :- (a) 1 No MCCB 4-pole 63 Amps 50HZ 415V 25 KA, (b) LED indication lamps etc with individual compartments door with locking system, and (c) 8-No's MCB SPN 40Amps as out going from single Energy meters 230 volts,50 Hz (d) refixing of old energy meter 8 Nos complete with necessary opening for reading out meter covered with provision of PVC transparent sheet, concealed in wall with all neccessory accessories such as SS brackets, hinges for door,bolts and nuts & screws etc complete all as specified and directed.
All as per item No- 212 here-in-before but Distribution cubical metering panel board of size 1.0x1.0x0.25m, compartment for 6-no's single phase Energy meter with neccessary electrical connection & testing on completion complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6.0 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connecting with steel GI earth wire 4mm dia by means of bolt nut check nuts and washers including PCC pit with 1:2:4 type B-1 using 20mm graded stone aggregate and frame cover of angle iron 25x25x6mm, MS sheet 3mm thick, and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering common salt chorcoal funnel wiremesh, earthwork in any type of soil returning filling in and removal of soft/loose soil to a distance n. exc 5 mtr including earth test point and making connections, testing on completion all as per electric plate No 3 of SSR Part-I and directed by engr-in-charge at site including taking down of old U/S eartning materials,Note :The unit rate quoted shall be inclusive of 7.5 metre earth lead.
C R R CONSTRUCTIONS
N RAJEGOWDA and CO
Phoenix Infra
Gnani Builders
UNITED TECHNO PROJECTS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .