| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | ₹14.0 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹15.2 L+₹1.2 L (8.88%)Rejected-Finance | ₹15.2 L+₹1.2 L (8.88%) | L2 | Rejected-Finance BIDDER NOT LOWEST |
| 3 | L3₹15.5 L+₹1.5 L (10.8%)Rejected-Finance | ₹15.5 L+₹1.5 L (10.8%) | L3 | Rejected-Finance BIDDER NOT LOWEST |
| 4 | L4₹21 L+₹7.0 L (50.1%)Rejected-Finance | ₹21 L+₹7.0 L (50.1%) | L4 | Rejected-Finance BIDDER NOT LOWEST |
| 5 | L5₹23.1 L+₹9.1 L (65.0%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹23.1 L+₹9.1 L (65.0%) | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Sept 2022, 6:00 pmClosed
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
REPAIR REPLACEMENT OF LT UG LT PANEL FEEDER PILLAR BOX DBS AND STREET LIGHT FITTINGS LT UG CABLE AT SALARIA OFFICERS ENCLAVE AT DWARKA UNDER GE WEST DELHI CANTT 10
2022_MES_545594_1
GE/DW-70/2022-23
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹60,000
27 Oct 2022
23 Aug 2022
21 Sept 2022
24 Aug 2022
19 Sept 2022
6 Sept 2022
Amount
M & L for Servicing of DG sets 140 KVA Make: Greaves cotton installed at Salaria PH; including routine checking of all Engine and alternator parts for its servicing/durability complete all as per manufacturer recommendatations and including repair of followings parts :- (a) Drain out the lubricating oil from sump and refilling after proper cleaning. (b) Replace Engine Oil filter cartridge with New one. (c) Replace fuel filter cartridge with New one. (d) Replace coolant fine filter with new one. (e) Replace air filter with New one. (f) Check tightness of all nuts and bolts (g) Check adjustment of V belt, driving engine water pump and alternator. (h) Assembling complete old serviceable parts and repair of old unserviceable parts by new one as per direction of Engr-in-Charge. (j) Testing of DG set after servicing as per Engr –in Charge. (k) Cleaning of air filter, fuel tank and radiator (Radiator should be clean with commpressed air and commpressor should be arrange by Contractor itself) every month as per requirement as per manufactures manual. Note:- (i) Any minor parts such as screws, washers, split pin , circlip etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted. (ii) The servicing of DG Sets shall be carried out all as per direction of Enge-in-Charge and site requirements. (iii) Any parts required to be replaced during servicing of DG/engines shall be measured and paid for separately.
S & F Oil filter as per exsting make and size for DG Set of capacity 140 KVA as per sample complete all as specified and directed.
S & F diesel Fuel filter Primary and secondary as per exsting make and size for DG Set of capacity 140 KVA as per sample complete all as specified and directed. .
S & F Air filter as per exsting make and size for DG Set of capacity 140 KVA as per sample complete all as specified and directed.
Supply and Filing of coolant in 140 KVA DG set complete all as specified and directed.
Supply and Filling of lubricant oil (15-20)W-40 in replacemen in KVA DG complete all as specified and directed.
M & L for taking down repair and refixing of self starter of 140 KVA DG capacity including repair of burn field coil repair of armature and carbon bush holder and carbon bush point and solinoid coil, frywheel ring complete all as specified and directed.
M & L for Repair/servicing of radiator assembly of 140 KVA DG Set after dismanteling and removing cooling fans, guard plates and lowering the same from engine after draining out water from radiator and scrapping / removing sludge / scale inside tank with acid including repair MS tank (botom portion) at rusted portion by cutting/ welding / brazing with 2mm thick copper plate including painting. Remounting the same at its original position and filling of pre mixed coolent as per the ratio fixed by manufacturer measured seperately and testing complete all as specified and directed.
M & L for Repair of battery Charger of any make including taking out from site and transporting to the electrical repair shop and taking back after repair and fix to the site complete all as specified and directed.
M & L for Disconnecting, taking out carefully old unserviceable AVR unit, supply & fixing, connecting and testing new AVR unit as per existing make and model suitable for DG set of 140 KVA capacity complete all as specified and directed.
M&L in repair for Tubular Battery 12 Volt 180 AH, complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning LT, XLPE insulated armoured, heavy duty aluminium conductor electric cable 1100 Volts grade, cross sectional area 240 Sqmm, 3.5 core including taking out old existing cable in trench/wall/feeder connections complete all as specified and directed.
All as per item No 12 but 3.5 core 185 sqmm.
All as per item No 12 but 3.5 core 150 sqmm.
All as per item No 12 but 3.5 core 50 sqmm.
All as per item No 12 but 3.5 core 35 sqmm.
All as per item No 12 but 3.5 core 25 sqmm.
All as per item No 12 but 4 core 16 sqmm.
Taking out/down 80mm bore steel tubing with fittings and M&L 80mm bore steel tubing light grade, galvanized with all fitting laid in trenches/poles complete all as specified and directed.
All as per item 19 but 40 mm bore size.
S&F in repair MCCB 3 pole suitable for AC 3 phase 415 volt 50 HZ, 400 Amp, 35 KA, with thermal magnetic release fixed on existing LT panel complete all as specified and directed. ' Note: Rate quoted deemed to include taking down the existing MCCB from panel board and incoming / outgoing cable and fix the new MCCB in position at panel board / incoming / outgoing cable connections of any size/ rating.
All as per item 21 but 250 Amps, 25 KA.Make
All as per item 21 but 200 Amps, 25 KA.Make
All as per item 21 but 125 Amp, 25 KA.Make
All as per item 21 but 100 Amp, 25 KA.Make
S&F in repair MCB double pole, 63 Amp 415 volt 10 KA complete all as specified and directed.
M&L in repair LT 1100 volts straight through joints kit epoxy type of size 16 to 95 sqmm 3.5 core, jointing LT UG cable complete all as specified and directed.
M&L in repair LT 1100 volts straight through joints kit epoxy type of size 120 to 240 sqmm 3.5 core, jointing LT UG cable complete all as specified and directed.
M & L servicing of feeder pillar box, after dismantling the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified. Note: (i) Spare parts such as terminals, lugs, nut bolts, insulators etc will be measured and paid under respective item in the schedule, (ii) Fixing charge of the spare parts deem to include the rate quoted for the items.
Supply only aluminium lugs of any type / shape of capacity 240 Sqmm
Supply only aluminium lugs of any type / shape of capacity 150 Sqmm
Supply only aluminium lugs of any type / shape of capacity 120 Sqmm
Supply only aluminium lugs of any type / shape of capacity 95 Sqmm
Supply only aluminium lugs of any type / shape of capacity 70 Sqmm
Supply only aluminium lugs of any type / shape of capacity 50 Sqmm
Supply only aluminium lugs of any type / shape of capacity 35 Sqmm
Supply only aluminium lugs of any type / shape of capacity 25 Sqmm
Supply only aluminium lugs of any type / shape of capacity 16 Sqmm
Supply only GI Nuts, bolts, screws, washers of required sizes
Supply only bus bar Insulators Epoxy type as required at site min size 45mm x 50 mm dia
M&L in repair for earthling complete with GI earth plate electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 Mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 Mtrs below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI wire 4 mm by means of bolts, nuts, chuck nuts, and washers and protected by medium grade 50 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering , including funnel, wire mesh, RCC 75 mm thick pit cover 1:2:4 type B-1 using 20 mm graded stone aggregate with and including 8 mm dia TMT bars @ 100 mm centre to centre both ways ,PCC chamber pit with PCC 1:2:4 B-1 ( including necessary form work, excavation and earth work, disposal of surplus soil two a distance not exc. 50 Mtrs) complete all as specified and shown in SSR – Part I 2009.
M&L in repair for Earthing complete with copper plate electrode 600x600x3.15mm thick electrode burried directly in ground not less than 1.5 mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and including and 20x3 mm copper strip as earth lead by means of bolt ,nuts, check nuts, and washers of stainless steel and duly welded incl PCC pit in PCC 1:2:4 type B-I angle iron 40x40x3mm frame, pit in PCC 1:2:4 type B-I cover 40mm reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20mm bore with funnel and wire mashand medium grade GI protection pipe 40mm bore and earth wire up all as shown in electrical plate No 3 of MES SSR- Part-I all as directed and specified by Engineer-in-charge.
S&F in repair earth continuity conductor or main earthling lead of Galvanised iron strip of size 25 x 4 mm, fixed on floor/ wall with supporting insulators / laid in trench from existing earth test point including taking down old items complete all as specified.
Supply and fix in replacement junction box made from SMC/FRP sheet ready made of size 300 X 200 X 100 mm having 100 A capacity for RYB and neutral with aluminium bus bar including all necessary insulators fix to Box and MCB SP 6 Amp 10 KA 240V with aluminium lugs - 01 No with 4 way connector fixed to Pole /Wall with MS clamp 25 X 5 mm with the help of suitable nuts and bolts.
Supply and fix in replacement 3 Pole contactor MNX 18, including necessary connections for incoming and outgoing connections complete all as specified and directed.
Supply and fix in replacement Timer for 24 hrs including necessary wiring from contactor and supply connections complete all as specified and directed.
Supply and fixing in replacement MS kiosk box made out from 2 mm thick MS sheet including bus bar TPN 4 strip 63 A capacity and one MCB SP 6 Amp for street light fitting to be mounted on pole with 2 nos 25x3 mm flat iron clamps and shutter to be opened and closed vertically with ball locking system size of box 200x150x100 mm complete complete all as specified and directed.
Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M&L for scrapping/removing rusted partials on surface of existing single swan neck steel tubular electric street light pole including nut and bolts after cleaning Applying one coat of red oxide and two coats of aluminium paint including stranded size of numbering and alternate strip black and yellow synthetic enamelled painting from the coping of pole as directed and two coats of cement base paint on surface area of copping complete all as specified and directed.
Supply and fixing in repair,passing through cable 3 core PVC insulated unsheathed multistranded copper conductor of size 2.5 Sqmm from junction box to street light fitting all as directed.
M&L for PCC 1:4:8 type D-2 using 40 mm grade stone aggregate as in foundation concrete for pole including finishing the exposed surface using extra cement complete all as specified and directed
M&L for PCC 1:2:4 type C-1 using 20 mm grade stone aggregate as in foundation concrete for pole including finishing the exposed surface using extra cement complete all as specified and directed
M & L for Locating electrical faults and repair work in underground LT cable of size 150 to 240 Sqmm whenever any fault arises at Salaria officers Enclave area, making complete supply system functional dully rectifying and cable repair work complete all as specified and directed. Note: (a) Whenever any breakdown reported the Contractor will have to take immeadiate action and send skilled Technecian/Tools immediately on site failing which a recovery @ 500 Rs per Hours will be charge from the contractrors due. (b) Any parts required to be replaced during repair work shall be measured and paid for separately.
M & L for Locating electrical faults and repair work in underground LT cable of size 16 to 85 Sqmm whenever any fault arises at Salaria officers Enclave area, making complete supply system functional dully rectifying and repair work complete all as specified and directed. Note: (a) Whenever any breakdown reported the Contractor will have to take immeadiate action and send skilled Technecian/Tools immediately on site failing which a recovery @ 500 Rs per Hours will be charge from the contractrors due. (b) Any parts required to be replaced during repair work shall be measured and paid for separately.
M&L for excavation in trenches in soft soil n.exc 1.5 Mtr wide and n.exc 1.5 meter in depth for laying of cables/pole etc setting out trimming the site forming bottom surface to required level complete all as specified and directed by Engr-in-Charge.
M&L for returning filling in-trenches including spreading leveling watering and well ramming in layers with soft/loose/dense soil n.exc 25 cm thick in each layer of soil complete all as specified and directed by Engr-in-Charge.
M&L for removing/excavated soil to a distance n.exc 50 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-Charge.
M&L for sand cushioning with a layer of sand Jamuna 23 cm thick (8 cm under and 15 cm above the cable) in trenches complete all as specified and as directed by Engr-in-Charge
M&L for old serviciable un-reinforced precast concrete cable covers for cable protection of class LV type 1 flat of size 250 x150 x 40 mm.
Supply and laying un-reinforced precast concrete cable covers for cable protection of class LV type 1 flat of size 250 x150 x 40 mm.
S & F Earthing Display Board made of UV based fibreglass material dully mounted on MS rod stand with PCC near earth Pit as per IS standard complete all as specified and directed.
M & L for Preparing old white wash surface of wall and ceilling of panal room size not less than 5.0 M x 5.0 M x 3.10 M and applying two coats of white wash of existing colour complete all as specified and as directed.
M & L for Cutting wild grass, bushes, creaper, unwanted vegetation from inside/ surrounding of E/M installations, near sweage pump installations as when directed and removing of unwanted material from installation compound and depositing where directed.
M&L for scrapping/removing rusted partials on surface of existing Bldg LT panel including nut and bolts after cleaning Applying one coat of red oxide and two coats of aluminium paint complete all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 241195.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum.
M/s S.G. BUILDERS
NAVDURGA BUILDERS
J B Electricals
Shiv Enterprises
Ridhi engineers and builders
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .