Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹35.1 L+₹9.1 L (35.0%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹37.5 L+₹11.5 L (44.2%)Rejected-AOC RATHER HOUSE SRINAGAR ALLOCHA BAGH SRINAGAR JAMMU KASHMIR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹37.7 L+₹11.7 L (45.0%)Rejected-AOC | L4 | Rejected-AOC L4 Bidder | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Recent ITR not uploaded by the bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
4 Jul 2023, 2:00 pmClosed
Chief Engineer, Srinagar Smart City Ltd
1st Floor Budshah Building Lal Chowk Srinagar
Upgradation, Illumination and other electrical works for Lal Chowk, Sri Nagar
2023_SSC_217568_1
E-N.I.T NO. 10-SSCL OF 06,2023-24. Dt-19-06-2023
Open Tender
Electrical Works
Item Rate
30 days
Lal Chowk Srinagar
Refer to SBD
3 documents required · 3 mandatory
₹1,000
Yes
CEO Srinagar Smart City Ltd
₹76,000
Yes
12 Sept 2023
20 Jun 2023
4 Jul 2023
20 Jun 2023
4 Jul 2023
20 Jun 2023
Amount
LAL CHOWK
Termination Junction box : Supply, installation, testing and commissioning of the PC (Polycarbonate) Termination junction box (IP67), terminal with 2 clamping units per pole 5-pole per pole, 4 x 4 mm² r / f, included cable entry: 3 x ESM 40, sealing range Ø 17-30 mm with one cable entries M 32 from the rear side lid fasteners sealable without accessories external brackets for wall fixing included colour: grey, RAL 7035, rated insulation voltage Ui = 690 V a.c./d.c., in accordance with IEC 60670-22, Incoming - 1 no. 4 core 4.0/2.5 sq mm copper armoured cable Outgoing - 2 nos. 3 core 2.5/1.5 sq mm copper armoured cable. Built in dimensions W 210 x H 155 x D 92 (Tolerance ± 10%) material: PC (polycarbonate), impact strength IK 09 (10 Joule), in accordance with IEC 62208:2011
Empty encloser for led driver : Supply installation testing & commisioning of Empty box (IP67) with installation equipment on DIN rails or mounting plates (order separately) with opaque lid fastener for tool operation sealable box walls without knockouts external brackets for wall fixing included, colour: grey, RAL 7035, material: PC (polycarbonate) mounting plate, glands and complete with all required accessories and hardware to complete the job in all resepcts. Built in dimensions W 170 x H 220 x D 96 (Tolerance ± 10%) material: PC (polycarbonate), impact strength IK 09 (10 Joule), in accordance with IEC 62208:2011
Cable : Supplying, erecting & terminating XLPE armoured cable 1100 V. 4 core 16 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe
Supplying, erecting & terminating XLPE armoured cable 1100 V. 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe
Supplying, erecting & terminating XLPE armoured cable 1100 V. 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe
GI Conduit : Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. Erected for enclosing XLPE armoured cable on wall/pole
Earthing System : Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete.
Supply installation testing & commissioning of exterior-rated architectural surface mounted IP67, neon flex in alluminum profile with mounting brackets/clamps (as per application). The power consumption should not be more than 5 watts per meter, System lumen output should not be less than 300 lumens per meter (Tolerance ±15%), diffused, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP67 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware, equiepment/controller, software etc. for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supply installation testing & commissioning of exterior rated floor recessed marker light IP68, (as per application). System lumen output should not be less than 50 lumens (Tolerance ±15%), The power consumption should not be more than 1 watts, diffused , CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be anthracite gray where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP68 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supply installation testing & commissioning of exterior rated 1000mm long floor recessed marker light IP68, (as per application). System lumen output should not be less than 250 lumens (Tolerance ±15%), The power consumption should not be more than 20 watts, diffused , CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be anthracite gray where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP68 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supply installation testing & commissioning of exterior-rated architectural surface mounted 450mm high bollard IP67, bollard fixture with brackets/clamps (as per application). The power consumption should not be more than 10 watts, System lumen output should not be less than 600 lumens (Tolerances +- 15%) floor washer optics, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the grey color with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be integrated non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP67 connectors are inclusive. Minimum IK07. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware, equiepment/controller, software etc. for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supply installation testing & commissioning of exterior-rated architectural wall mounted IP67, led up & down light fixture with brackets/clamps (as per application). The power consumption should not be more than 2 x 5 watts, System lumen output should not be less than 2 x 300 lumens (Tolerance ±15%), up & down 30 degree beam angle, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP67 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware, equiepment/controller, software etc. for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer
Supply installation testing & commissioning of exterior rated pole mounted flood light IP67, (as per application). System lumen output should not be less than 1800 lumen with snoot (Tolerance ±15%), The power consumption should not be more than 30 watts, 30°/10° beam angle with tolerance of ±15%, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be anthracite gray where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be included non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP67 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supply and erection of 10 meter high pole made out MS Pipe Ø76.1mm confirming to YSt 210 and facilitating the luminaire mounting at the top. The pole shall be surface mounted on a concrete foundation. The base plate of the of the pole shall be E 250 grade MS 200 mm x 200mm, 12mm thick confirming to IS2062:2011 shall be facilitated with elongated slots to suit the 300mm, J-type, M16 bolts, Grade 4.6 that shall be provided with suitable nuts and plain washers. The structurally sound pole emerging out of the base plate shall be architecturally designed with a decorative cast aluminium causeway base cover minimum Ø330mm x 500mm (H), above which the leaf decoration cast aluminium structure Ø 150mm is aesthetically positioned. Mounted flower pot. The grade of pressure diecast material shall be ADC12. A GDC embellishment is provided at appropriate height enhancing the decorative outlook of the pole. The grade of gravity die cast material shall be LM6. The Pole welding shall be done with certified welders using a V groove technique with a high end MIG welding process. A base compartment with a die cast aluminium door contoured to the poles's shape housing the gear tray, prewired with 2 way connector. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thoroughremoval of impuritise like, rust, oxides and other unwanted particles from the suface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating or epoxy zinc phosphate primer followed by the environmentally stable Polyurethane based paint. Pole must be connected to earthing. (All the technical parameters of luminaire need approval from lighting designer)
Supplying, installing, testing & commissioning of Ceiling fan of 900 mm sweep with all accessories including Electronic Regulator for completing installation
Supply installation testing & commissioning of interior rated ceiling surface mounted led light IP54, (as per application). System lumen output should not be less than 1500 lumens (Tolerance ±15%), The power consumption should not be more than 18 watts, diffused, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be anthracite gray where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, and SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, connectors are inclusive. Minimum IK06. The operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting designer)
Supply installation testing & commissioning of interior rated wall mounted led linear light IP54, (as per application). System lumen output should not be less than 1500 lumens (Tolerance ±15%), The power consumption should not be more than 18 watts, diffused, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be anthracite gray where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, and SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, connectors are inclusive. Minimum IK06. The operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting designer)
Supply installation testing & commissioning of exterior rated architectural floor/wall mounted IP66, 1000mm long linear light complete with visor and adjustable mounting brackets/clamps (as per application). The power consumption should not be more than 18 watts, System lumen output should not be less than 1500 lumen (Tolerance ±15%), 10°x25° beam angle with tolerance of ±15%, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP66 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware, equiepment/controller, software etc. for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer
Supplying and fixing factory fabricated hot dip galvanized switch box for normal flush type accessories of minimum 1.2 mm (18 SWG gauge) thickness with earth terminal stud with nut and washer, with 3 mm thick synthetic phenollic resin bonded laminated sheet conforming to grade P-I of IS:2036-1974 on surface / concealed including painting etc. as required as per specification:
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI marked modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as Required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Siingle pole)
Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 63A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Group B
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
2 pairs
Cat-6 cable
Supply installation testing & commissioning of 90 Watts 1400 Rpm 12 Inch ( 300 Mm ) Heavy Duty Exhaust Fans
ASHIQ HUSSAIN BHAT
M/S SARIM ELECTRICAL SOLUTION
M/s NORTHERN ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .