| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 CrAccepted-AOC | ₹8.4 Cr Quoted ₹8.5 Cr | L1 | Accepted-AOC Accepted being L1 bidder. |
| 2 | L2₹8.9 Cr+₹49.9 L (5.90%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹8.9 Cr+₹49.9 L (5.90%) | L2 | Rejected-Finance Rejected being higher than L1 bidder. |
| 3 | L3₹9.8 Cr+₹1.3 Cr (15.8%)Rejected-Finance | ₹9.8 Cr+₹1.3 Cr (15.8%) | L3 | Rejected-Finance Rejected being higher than L1 bidder. |
| 4 | L4₹10.0 Cr+₹1.5 Cr (18.1%)Rejected-Finance | ₹10.0 Cr+₹1.5 Cr (18.1%) | L4 | Rejected-Finance Rejected being higher than L1 bidder. |
| 5 | L5₹10.2 Cr+₹1.7 Cr (20.7%)Rejected-Finance 23 A H4 DAIMOND HARBOUR ROAD NEW ALIPORE KOLKATA 700 053 WB | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹10.2 Cr+₹1.7 Cr (20.7%) | L5 | Rejected-Finance Rejected being higher than L1 bidder. |
Tender Value
₹10.3 Cr
EMD Value
₹8.4 L
Closing Date
10 Nov 2021, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF SUN SHELTER PH I AT AF STN KALAIKUNDA
2021_MES_444006_2
88877/KKD/E8
Open Tender
Civil Works
Lump-sum
630 days
GE (P) (AF) Kalaikunda
As per tender documents
7 documents required · 7 mandatory
₹3,000
GE (P) (AF) Kalaikunda
₹8.4 L
Yes
1 Dec 2021
7 Oct 2021
12 Nov 2021
7 Oct 2021
10 Nov 2021
3 Nov 2021
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to VI are prepriced by MES under Ser Nos. 2.00 to 6.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
SCHEDULE "A" PART -I (BUILDING WORK/ SUN SHELTER) Design, Construction and Erection of Pre-Engineered Buildings (Six units in a series with a crumple junction after three units) steel structure of each size 32mx30mx8m (clear inner dimensions) with Alu-zinc colour coated profiled steel roofing sheets 0.55mm thick (TCT) and yield strength of 550 MPa in roofing and cladding in gable portion camouflage pattern including RCC foundation, anchor bolts, base plates and all structural steel items, bird proofing net, rain water eaves gutters and down take pipes etc complete all as specified and as shown on approved drawings. Note for item No 1.01 :- (i) PEB structure to be designed to withstand 180 Km/hr (both in line and cross winds) and based on soil parameters. (ii) The rate quoted shall deemed to include the cost of designing and vetting of design of PEB structures by IISC Bangalore/ IITs/ NITs. The design (showing full calculations and details) vetted by IISc Bangalore/ IITs/ NITs shall be submitted to the department as per time schedule. (iii) Suitable eves gutters and rainwater downtake pipes as required shall be provided to divert rain water from the roof to ground level . (iv) The rate quoted is deemed to include the cost for provision of necessary arrangement for fixing light fittings.
SCHEDULE "A" PART-II (SITE CLEARANCE, EARTH WORK AND EXCAVATION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-IV (ADDN/ ALTN TO RIGID PAVEMENT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (LIGHTNING PROTECTION) Details of prepriced Schedule is given in tender documents.
Note:- Schedule ‘A’ Part I & VII are not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' 6 ' signifies this fact only.
SCHEDULE "A" PART -VII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
Demollition of cement concrete (unreinforced) of any description and in any position complete all as directed.
INTERNAL ELECTRIFICATION. S&F LED high bay light (round) having high efficiency with pressure die-cast housing,having fin ventilation technology for better thermal management, having effiicacy of 130 Lm/ Watt, of capacity of 120 watt, IP 66, 240 Volt, 50 HZ, for installation in hanger roof by providing all necessary accessories, MS clamp for hanging and fixing of light fitting including making electrical connection by providing 1.5 Sqmm x 3 core sheathed flexible copper conductor cable from light fitting to source/ ceiling rose of supply complete all as specified and directed by Engineer in charge. Make:- Crompton Cat Part No. LHBII-120-CDL/60 HPM or equivalent as per list of make. Note : (i) All LED Highbay light fittings street lights shall be properly connected with earth dolly provided with fittings and earth conductor/ earth wire. (ii) All LED lights have replacement warranty of 3 years from the date of completion of the contract. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 3 year replacement warranty certificate. (iii) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact. (iv) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries. (v) All LED fitting shall be identified by printing or fixing stickers duly mentioned the C.A number and date of completion. (vi) For any change in product or change in catalogue No. etc due to technological upgradation, letter has to be obtained from the lighting company on their letter head signed by an offical of National level. (vii) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade 4.00 Sqmm (Nominal area) FRLSH PVC insulated and unsheathed copper conductor cable, having multi-stranded copper conductor drawn in but including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc as approved by EIC including PVC insulated unsheathed FRLSH cable 4.00 Sqmm cable with multistranded copper conductor green colour as contineous earth conductor cable connected to earth dolly complete all as specified and directed. Note: Two single core 4.00 Sqmm cable for phase and neutral and one single core 4.00 Sqmm cable as earth conductor including steel conduit shall be measured as one run.
ADDN ALTN TO RIGID PAVEMENT M & L for Dry clean sand passing through IS sieve 2.36mm and held in IS sieve 600 micron, spread and compacted to 10mm thickness complete all as specified and as directed.
M & L for Polythene film (transparent colour) in single layer of 400 micron thickness, virgin quality as per ASTM D2103 / IS 2508 laid over sand layer with side and end overlapping not less than 300 mm complete all as specified and as directed. Note:- (a) Measurement shall be taken for net area and unit rate quoted shall deemed to include for overlapping. (b) Sand layer will be measured and paid separately under relevant item of this Schedule.
M & L for Pavement Quality Cement Concrete (PQC) work in pavement of flexural strength 45 kg / sqcm (lower control limit - LCL) in field using minimum 400 kg of cement per cubic metre or as per design mix, mixed with and including triangular/ non circular synthetic polyster fibre reinforcement @ 0.25% by weight of cement, spread and compacted by using slip form paver, thickness of concrete 350mm all as specified including necessary form work, bull nosing / rounding off edges, finishing by mechanical brooming / belting, curing etc., complete all as specified and as directed. Note:- (a) Construction joints/ dummy (contraction joints) and expansion joints shall be measured and paid separately under respective items. (b) Deduction shall be made in computing concrete quantity for expansion joints. (c) No price adjustment shall be applicable if excess quantity of cement than the minimum is used / approved based on mix design in the execution of work under this item. (d) Cost of admixtures, fibres to maintain as required by design mix is deemed to be included in the rate quoted. (e) Maximum cement content shall be 425 kg / cum and design mix shall be based on the same.
Forming 25mm wide expansion joint, filled with compressible synthetic filler board, for complete depth of joint, i.e 300mm, provision of closed cell polyethylene backup rod 30mm dia, filled with polyurethane sealant (Minimum depth of sealant above polyethylene rod shall be of 15 mm) complying with BS-5212, BS-4254 and EN - 141875 - 2003 (for hydrolysis / water resistance test) priming the sides, with minimum MAF ±30 % (with ten years performance guarantee) and applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawing and all as specified and as directed. Note:- (a) The make of filler board shall be of brand "DURA board HD 100" manufactured by M/s Supreme Industries Ltd or equivalent of makes listed here-in-after. (b) The synthetic filler board shall be premoulded compressible black in colour having minimum density of 100(±)10%Kg/cum, water absorption less than 0.09Kg/sqm and compression recovery of 93%. (c) The make of polyethylene rod shall be of brand "DURA Rods" manufactured by M/s Supreme Industries Ltd or equivalent of makes listed here-in-after. (d) The polyethylene rod shall be of desired diameter having minimum density of 22Kg/cum and compression strength of 0.40Kg/sqm, 25% greater than the joint width, of white colour. (e) Primer to be used before filling sealant (f) Edges shall be bevelled and joints cut within 24 hours using diamond bit cutters of Bosch or equivalent used for cutting green concrete. (g) The exposed vertical faces of slab shall be applied with one coat of white wash.
Forming contraction (Dummy) joints, cutting 100mm deep with 3mm width as initial cutting and secondary cutting of 25mm deep from the top and 8mm wide using diamond cutter to accommodate polyethylene backup rod 10mm dia and sealed with polyurethane sealant (Minimum depth of sealant above polyethylene rod shall be of 15mm) complying with BS:5212, BS:4254 and EN-41875 -2003 (For hydrolysis / water resistance test), priming the sides, minimum movement accommodation factor (MAF)±30% with ten years performance guarantee) and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces to give neat finish to the sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawing and all as specified and as directed. Note:- (a) The make of polyethylene rod shall be of brand "DURA Rods" manufactured by M/s Supreme Industries Ltd or equivalent of makes listed here-in-after. (b) The polyethylene rod shall be of desired diameter having minimum density of 22Kg/cum and compression strength of 0.40Kg/sqm, 25% greater than the joint width, of white colour. (c) Primer to be used before filling sealant (d) Edges shall be bevelled and joints cut within 24 hours using diamond bit cutters of Bosch or equivalent used for cutting green concrete.
Forming construction joint, 24mm deep and 8mm wide (using diamond cutter), providing polyethylene backup rod 10mm dia and sealed with polyurethane sealant (Minimum depth of sealant above polyethylene rod shall be of 10mm) complying with BS:5212, BS:4254 and EN-41875 -2003 (For hydrolysis / water resistance test), priming the sides, minimum movement accommodation factor (MAF)±30% with ten years performance guarantee) and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces to give neat finish to the sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawing and all as specified and as directed. Note:- (a) The make of polyethylene rod shall be of brand "DURA Rods" manufactured by M/s Supreme Industries Ltd or equivalent of makes listed here-in-after. (b) The polyethylene rod shall be of desired diameter having minimum density of 22Kg/cum and compression strength of 0.40Kg/sqm, 25% greater than the joint width, of white colour. (c) Primer to be used before filling sealant (d) Edges shall be bevelled and joints cut within 24 hours using diamond bit cutters of Bosch or equivalent used for cutting green concrete.
M & L Painting lines, dashes, arrows, letters, etc., on roads, pavements and the like exceeding 10cm wide with aqua based road marking paint, two coats, white or golden yellow complete all as specified and as directed. .
Cutting circular hole of dia 200 mm and 50 mm deep of any grade of concrete, cut to shape using concrete cutter, drilling holes of 24 mm dia, 2 nos, to a depth of 200 mm, fixing 20mm dia round bars inverted "U" shape with minimum 200 mm anchorage projecting upto 50mm to be flush with cut concrete surface, exposed steel surface painted with two coats of synthetic enamel paint over a coat of Red oxide zinc chrome primer, grouting the drilled holes using solid grout with high flow non shrink cementious grout, after applying bonding coat leaving the 200mm dia circular hole open to 50mm depth as in mooring rings complete all as specified and as directed. Note:- (a) The concrete cutting shall be carried out by concrete cutter DCH 300 of DD 200 machine of HILTI, holes bored by TE 70 Combi -hammer of HILTI. (b) The grout shall be of Comextra brand and bonding agent of Nitobond EP of M/s Fosroc India or Equivalent of makes as listed hereinafter.
EXTERNAL ELECTRIC SUPPLY Supply and jointing straight through joint kit heat shrinkable suitable for XLPE LT UG cable of 240 Sqmm x 3.5 core , 1100 volts grade including all acessories and ferrules as per required size complete including testing of joint . Make:- M-Seal/ Denson/ Raychem
S & F cable route marker made up of cast iron (Round Dia ) of 100 mm round plate, 3 mm thick fixed on MS angle iron of size 25 x 25 x 5 mm, 800 height fixed in ground over the cable route with PCC 1:2:4 complete all as specified and directed by Engineer in charge.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine without distrubing the road surface / Pavment surface/ Hard standing /RCC surface for laying of GI pipe/ HDPE pipe of max size 150 mm bore for protection of LT cable layed in underground all as specified and directed by Engineer-in-Charge. Note : Cost of GI/ HDPE pipe for protection of cable will be paid sepeartly under relevant item.
(B)Outgoing (i) MCCB 63 Amps rating, 4 pole , 415 V, AC, 50 HZ, thermal Magnetic release type, having thermal release range 50-63 Amp with adjustable overload and short circuit setting, Ics=100 % Icu , Service breaking capacity 25 kA - 07 Nos with rotatary handle(06 x operational + 01 x standby). Make : L& T cat Part No. CM91712OOHOOG or equilvalent in Legrand / Siemens / Scheineder. (ii) MCB SPN, 240V , 40-63A, 50 HZ, "C "curve, 10 KA - 02 No.
(B) Outgoings : Following items to be fixed in outgoing in panel in compartments :- (i) Tempra Plug socket , industrial type, Three Pole & Neutral enclouser, As per IEC 61439-3, IK 08, suitable for flush / surface mounting, with neutral link, including 32 Amp FP MCB (3P+N+E - FP), 415 V , 10 kA , C-curve, including socket and plug, making all electrical connections, including providing of suit size copper lugs etc .- Qty - 02 Nos, Make- Legrand, Model Ekinox 3 P17, Cat Part No. 507862 or equivalent in Seimens/ Schinder/ L&T. (ii) Tempra Plug socket, industrial type, Single Pole & Neutral enclouser, As per IEC 61439-3, IK 08, suitable for flush / surface mounting, with neutral link, including 32 Amp DP MCB (2P + E - DP), 240 V , 10 kA , C-curve, including socket and plug, making all electrical connections, including providing of suit size copper lugs etc .- Qty - 02 Nos, Make- Legrand, Model Ekinox 3 P17, Cat Part No. 507863 or equivalent in Seimens/ Schinder/ L&T. (iii) Tempra Plug socket industrial type, Single Pole & Neutral enclouser, As per IEC 61439-3, IK 08, suitable for flush / surface mounting, with neutral link, including 16 Amp DP MCB (2P + E - DP), 240 V , 10 kA , C-curve, including socket and plug, making all electrical connections, including providing of suit size copper lugs etc .- Q ty - 02 Nos, Make- Legrand, Model Ekinox 3 P17, Cat Part No. 507860 or equivalent in Seimens/ Schinder/ L&T. (iv) MCB SPN 6-32 Amp , AC , 220 Volt , 10 kA , C-curve , ISI marked, as per IEC 60898-1 2002 - Qty -6 Nos (5 x operational + 1 x spare)
Note for item Sl No. 22 & 24: LT Panels (i) Contractor shall submit the general arrangement drawing of LT Panel and take prior approval of GE before placing the order for procurement. (ii) Contractor shall provider Phase barriers and spreader terminals with all MCCB`s. (iii) Contractor shall provide metal gland, suitable size aluminium lugs/ copper lugs as per cable size, steel nut bolts etc for connection of cable in Panel box. (iv) Make of MCCB`s and MCB`s shall be of Make : L&T/ Legrand/ Siemens/ Schinder. (v) Contractor shall submit the Purchase Voucher and Test certificate of Panel. (vi) Rotary handle to be provided for all MCCB for control and operation of MCCB. (vii) The copper bus bar of out going feeders (extesion link from bus bar to out going MCCB/ MCB`s) shall not be less than 1.5 times the rated current of individual out going feeders.
S&F for Test point junction box made of polycarbonate without terminal block 130x180x77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation.
M&L earthing complete with copper earth plate electrode 600mm x 600mm x 3 mm thick burried directly in ground (Earth pit not less than 3.0 m deep below ground level) with top edge of the plate not less than 2.25m below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation in any type of soil(except rock), filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from outside defence land, and to be mixed with and including bentonite - 03 bags of 25 KG each for each pit, construction of PCC earth pit chamber of size 900 x 900 x 450 mm , RCC chamber cover plate, wire mess, funnel, test point, 32 mm dia GI protection pipe light grade and 40 mm GI medium grade peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge Note : (i) Fresh agriculture soil will be used for filling the dug as required to achieve the desired resistance from out side (ii) Contractor has to provide bentonite -03 Bags ( each bags of 25 KG) to mix with fresh agriculture soil in each earth pit to achive desired resitance. (iii) Copper strip will be laid below 100mm from ground level and connected to test point through plinth protection. (iv) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor through double nut bolt and brazing of joints, argiculture soil to be bring from out side deemed to be included in the item rate. (v) Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately. (vi) Contractor has to clear the site and disposed of the excavated soil (obtained from the pit ) from the site at the location as directed by Engineer in charge. (vii) Earth test point to be made inside earth pit by providing joint between downward conductor/strip coming from ground to earth continuity strip going to LT Panel.
LIGHTNING PROTECTION S&F for thermo plastic(polycarbonate) junction box for test point without terminal box all dimensions 130x180x77mm IP 66 halogen free and weather proof including four hexagonal anti corrosive screws for outdoor installations.
M/S Janak Raj Gumber
R N INFRA PROJECTS
Saldar Infrastructure and contracts private limited
SETH GHANSHYAM DAS LAKHMAMI AND CO
Saraogi Infrastructure
M P KHAITAN
KAKALI ENTERPRISE
NARSINGH DEVELOPERS LLP
surendra infrastructure pvt ltd
MS SHRI B.C. DAS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_535979.xls
BOQ Document • 0.36 MB
84962869.pdf
Tender Document • 0.54 MB
Tender.pdf
Tender Document • 3.31 MB
84962871.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .