Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC 06 GOVIND NAGAR PANCHAYAT USR TRANSPORT CAMPBELL BAY OLD FISHERMAN COLONY CAMPBELL BAY GREAT NICOBAR ISLANDS | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.2 L+₹40,910.66 (2.77%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹15.5 L+₹70,416.74 (4.77%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹15.6 L+₹81,676.56 (5.53%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹15.9 L+₹1.1 L (7.72%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹28,500
Closing Date
17 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) Campbell Bay
Garrison Engineer (I), Military Engineer Services, Army Land, Great Nicobar Islands, Campbell Bay, Pin 744 302
PROVN OF BRIEFING ROOM AT INS BAAZ CAMPBELL BAY
2021_MES_425174_1
8731/E8
Open Tender
Civil Works
Item Rate
180 days
Campbell Bay
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) Campbell Bay
₹28,500
Yes
22 Apr 2021
24 Feb 2021
19 Mar 2021
3 Mar 2021
17 Mar 2021
3 Mar 2021
60 days
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil all as specified and directed.
Ditto all as per item No 2 but depth exceeding 1.5 m and not exceeding 3 m all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation, filling and mass concrete all as specified and directed.
M & L for Use and waste of formwork to sides of concrete foundations, footings, bases of columns raft and raft beams sides and soffits of foundation and plinth beam and similar work vertical or to batter all as specified and directed.
M & L for Use and waste of formwork to sides of pillars, posts, struts, piers, column and stanchions for rough finished surfaces of concrete square, Circular rectangular on plan or polygonal all as specified and directed.
M & L for Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete flat all as specified and directed.
M & L for Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete all as specified and directed.
M & L for Use and waste of formwork to chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat all as specified and directed.
M&L for Reinforced cement concrete M30 (Design Mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete all as specified and directed.
M&L for Reinforced cement concrete M30 (Design Mix) using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed.
M&L for Reinforced cement concrete M30 (Design Mix) using 20 mm graded stone aggregate as in beams, bands, cantilevers, bressummers, lintels over 1.5m span, all as specified and directed.
M&L for Reinforced cement concrete M30 (Design Mix) using 20 mm graded stone aggregate as Chajjas all as specified and directed.
M&L for Mild steel TMT reinforcement Bars of 10 mm dia and over, cut to length, bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clip all as specified and directed.
M&L for Mild steel TMT reinforcement bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securing with clip all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed..
M&L for Antetermite treatment, treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) all as specified and directed.
M&L for Antetermite treatment, treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as specified and directed.
M & L for Antetermite treatment., treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and directed.
M&L for Antetermite treatment, treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks of PCC 1:3:6 type C-1 using 20 mm graded aggregate , exc. 10 cm in width and setting in mortar 1:6, complete all as specified and directed.
S&F Roof truss framed, trussed purlins vranes, gantries, rails and fastenings with brackets framing ( Beam, Tee , Angle, Channel and Flat Section) incl distance piece,cleats etc confirming to FE 410 complete all as specified and directed.
M&L for Rolled mild steel sections conforming to Fe 410 -W (Gde E- 250) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates all as specified and directed.
S&F of Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F of Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
M&L for Hard core of gauge n.exc 63 mm , with broken stone or boulders , deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8 type D-2, (using 40 mm graded aggregate) as sub base complete all as specified and directed.
M&L for Rendering 10 mm thick in cement plaster 1:6 on fair faces of concrete surfaces finished even and smooth without using extra cement all as specified and directed.
M&L for Rendering 15 mm thick in cement plaster 1:4 on fair faces of concrete surfaces surface finished fair and even mixed with WPC as per manufacturer's instructions complete all as specified and directed. (Supply only of WPC shall be measured and paid separately).
Supply only of Integral waterproofing compound of approved make all as specified and directed.
M&L for nonskid coloured Ceramic joint free tiles (Matt finish) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed in cement mortar 1:6 over 25 mm thick PCC screed 1:2:4 type B-0 using 12.5 mm graded stone aggregate all as specified and directed.
All as per item No 32 above but on vertical surfaces as in skirtings over 10 mm thick rendering in cement mortar 1:4 all as specified and directed.
M&L for 75m mm thick plain cement concrete type C-1, 1:3:6 mix using 20mm graded stone aggregate as in plinth protection, pavings, path etc. surface finished even and smooth without using extra cement including making 6 mm wide grooves to full depth at 2 to 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ration of 1:3 by weight complete as specified and directed.
S&F of 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Aluminium framework in ceilings including Anodised aluminium snap grid frame work of size 605 x 605mm for false ceiling and applying three coats of white wash over ceiling boards all as specified and directed.
M&L for Preparation of new or previously un treated surfaces of steel and iron surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome paint all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coat of distemper oil emulsion white tinted over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coat of cement base paint over a priming coat complete all as specified and directed.
M&L for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc., complete all as specified and directed.
S&F of Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S&F of Anodised aluminium window and ventilator shutters glazed and gauged, side hung type without sash bars for aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays, hinges, suitable handles etc., complete all as specified and directed.
S&F of 5.5 mm thick Sheet Glass, ordinary quality and glazing with aluminum doors / partitions all as specified and directed.
S&F of 4 mm thick Sheet Glass, ordinary quality and glazing with aluminum windows all as specified and directed.
M&L for 12 mm thick Prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations fixed to aluminum doors / partitions all as specified and directed.
M & L for point wiring (concealed) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic heavy grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes,modular switch plates and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed by EIC. (a) One light point controlled by one modular switch
(b) One fan point controlled by one modular switch
(c) One switch socket outlet modular type 3 pin 6 amp on same board.
All as per item No 45 above but 1.5 sq mm cable size and 1.5 sq mm earth continuity wire for one 3 pin socket outlet, 6 amps on Independent board.
All as per item No 45 above but 2.5 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board.
S & F 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 3600 total lumen.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection 2KV ,ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz ,The system efficacy must be between80-100 lumen /watt ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than 0.95 , THD < 10% . Indivisual LED's should not be visible for glare free output ,colour temperature 6500k all as directed. Make : CG , Phillips, Bajaj.
S & F 0-4 step, one module, modular type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 100 Watts humfree single pole, all as specified and as directed by EIC.Make:- Anchor/Legrand/Havells
S & F Switch modular type, single pole one way 6 Amps, 250 volts Ac suitable for modular switch boxes without indicator, all as specified and as directed by EIC.Make:- Anchor/Legrand/Havells
S & F socket modular type single pole one way 6 Amps 2/3 pin 250 volts including taking down the old modular socket.
M & L for ceiling rose, surface bakelite, 65 x 50 mm, two to three terminals all as specified and as directed by EIC.Make:- Anchor
S & F socket modular type 16 Amps, 3 pin combine, 2 module,240 volts all as specified and as directed by EIC.Make:- Anchor/Legrand/Havells
S & F switch modular type 16 Amps, 1 module,240 volts all as specified and as directed by EIC. Make:- Anchor/Legrand/Havells
S & F sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amps , 240 Volts, Make :- Legrand Cat No 507811, L & T, Havells.
S & F sheet metal enclosures for DB's for incorporating MCBs, TPN, 4 way, IP-43 double door with 200 amps rated busbar, 415 volts, as per IS-8623 including taking down the old unserviceable TPN DB, all as specified and as directed. Make : Legrand, Havells, L & T
S & F MCB Four pole 63amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. Make : Legrand Cat No. 408702 or equivalent in Havells, L&T.
S & F MCB SP, 10 Amps to 32 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. Make : Legrand or equivalent in Havells, L&T.
M & L for Earthing complete with galvanised steel plate electrode, 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in para No. 4 to the earthing test point all as specified and as directed. Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing all as specified and as directed by EIC.
S & F Energy saving ceiling fan 1200 mm sweep ,BEE 5 star rated complete including provision of three core copper wire of suitable size, connected from ceiling rose to fan complete all as specified and as directed. Make : Crompton Greaves, Havells, Usha.Bajaj
S & L XLPE, insulated, armoured, heavy duty, electric cable with stranded aluminium conductors, 1100 volts grade, laid in tranches/fixing on wall/poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, including taking down existing unserviceable cable with GI protections pipes, complete all as specified and as directed by Engineer-in-Charge of cross sectional area 10 Sqmm 4 core.Make:- Havells/Gloster/ Polycab
S&F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.Make:- Telerex/ Gemini or Equivalant
M/s K Moorthi
RS ENGINEERING WORK
M/s Bismi Builders & Enterprises
B.R. ENTERPRISES
Y Abulu
SKV Engineering
CHANDER SEKER ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .