Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹18.9 L+₹50,200 (2.73%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹21.6 L+₹3.2 L (17.5%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹23.3 L+₹5.0 L (27.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹23.6 L+₹5.3 L (28.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
11 Jul 2024, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR MAINTENANCE OF DG SETS CONTROLLING PANELS ALONG WITH CONNECTED ITEMS UNDER GE NAGROTA
2024_MES_659738_1
CA NO GEN-36/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAGROTA
class d Category b i
8 documents required · 8 mandatory
₹500
Yes
GE NAGROTA
₹56,000
Yes
25 Sept 2024
14 Jun 2024
13 Jul 2024
14 Jun 2024
11 Jul 2024
29 Jun 2024
Amount
Schedule A Part -I Dismantaling /Opening of upper portion of Disel Engine 320 KVA to 125 KVA (Make : Greaves/ Kirloskar/ Cummins or any other make) air cooled,turbo charged ,Vertical type for top over hauling, repair/ servicing of engine including taking out rediator /fuel pump,water Pump,Turbo charger etc (Egnine oil and coolent reaquired for this job is deemed to be included in the quoted rate complete all as specified and directed (a) Dismantaling/Opening of complete cyllinder head assebly rockers arms assemblypiston head assembly ,sleeves by removing nuts & bolts for repair complete. (b) Servicing & washing of complete engine partswith kerosine oil ( c) Re- assembling of engine after replacementof UNSV/defective parts with new parts as listed in given below per Job shall be deemed to be included in this rates and testing of engine as per company recommendation after reassembling all parts as directed to the satifaction of the Engr-in -Charge Note : Repair and Transportation (BY JCB / HYDRA OR ANY OTHER MEANS) charge for carrying out repair & reinstall on same installation back shall be deemed to be included in this rates
Supply & fix in replacement of following parts given below , The quoted rates shall be deemed to be above job included .
i) Valve Exhaust
ii)Valve inlet
iii)insert Valve Seat
iv)Guide Valve
v)Cup Injector
vi) Fip Element
vii) Gasket Set
viii) Hose Pipe
ix) Fuel Filter
x) Lubrication Oil Filter
xi) Super By Pass Fillter
xii) Hose Clip Set
xiii) Piston set Complete
xiv Ring Set Complete
xv) Cyllinder Linner
xvi) Connecting Rod Bearing
xvii) Gasket Set Cyllinder Head
xvii) Callibration of Fuel Pump
xix )Head Repair Work
xx ) Callibration of injectors of Nozzels
xxi ) Lubrication Oil Pump
xxii ) O ' Ring Set Complete
xxiii) Set of Fuel Flexible Pipe
xxiv) Stem Seal
Dismantaling /Opening of upper portion of Disel Engine 125 KVA to 62.5 KVA (Make : Greaves/ Kirloskar/ Cummins or any other make) air cooled,turbo charged ,Vertical type for top over hauling, repair/ servicing of engine including taking out rediator /fuel pump,water Pump,Turbo charger etc (Egnine oil and coolent reaquired for this job is deemed to be included in the quoted rate. (a) Dismantaling/Opening of complete cyllinder head assebly rockers arms assemblypiston head assembly ,sleeves by removing nuts &bolts for repair complete. (b) Servicing & washing of complete engine partswith kerosine oil ( c) Re- assembling of engine after replacementof UNSV/defective parts with new parts as listed in given below per job shall be deemed to be included in this rates and testing of engine as per company recommendation after reassembling all parts as directed to the satifaction of the Engr-in -Charge Note : Repair and Transportation (BY JCB / HYDRA OR ANY OTHER MEANS) charge for carrying out repair & reinstall on same installation back shall be deemed to be included in this rates
Supply in replacement of following parts given below rates shall be deemed to be above job included .
Valve Exhaust
Valve inlet
insert Valve Seat
iv)Guide Valve
v)Cup Injector
vi) Fip Element
vii) Gasket Set
viii) Hose Pipe
ix) Fuel Filter
x) Lubrication Oil Filter
xi) Super By Pass Fillter
xii) Hose Clip Set
xiii) Piston set Complete
xiv Ring Set Complete
xv) Cyllinder Linner
xvi) Connecting Rod Bearing
xvii) Gasket Set Cyllinder Head
xvii) Callibration of Fuel Pump
xix )Head Repair Work
xx ) Callibration of injectors of Nozzels
xxi ) Lubrication Oil Pump
xxii ) O ' Ring Set Complete
xxiii) Set of Fuel Flexible Pipe
xxiv) Stem Seal
Dismantaling /Opening of upper portion of Disel Engine 62.5 KVA to 20 KVA (Make : Greaves/ Kirloskar/ Cumiuns or any other make) air cooled,turbo charged ,Vertical type for top over hauling, repair/ servicing of engine including taking out rediator /fuel pump,water Pump,Turbo charger etc (Egnine oil and coolent reaquired for this job is deemed to be included in the quoted rate. (a) Dismantaling/Opening of complete cyllinder head assebly rockers arms assemblypiston head assembly ,sleeves byremoving nuts &bolts for repair complete. (b) Servicing & washing of complete engine partswith kerosine oil ( c) Re- assembling of engine after replacementof UNSV/defective parts with new parts as listed in given below Per job shall be deemed to be included in this rates and testing of engineas per company recommendation after reassembling all parts as directed to the satifaction of the Engr-in -Charge Note : Repair and Transportation (BY JCB / HYDRA OR ANY OTHER MEANS) charge for carrying out repair & reinstall on same installation back shall be deemed to be included in this rates
Supply in replacement of following parts given below rates rates shall be deemed to be above job included .
i) Valve Exhaust
ii)Valve inlet
iii)insert Valve Seat
iv)Guide Valve
v)Cup Injector
vi) Fip Element
vii) Gasket Set
viii) Hose Pipe
ix) Fuel Filter
x) Lubrication Oil Filter
xi) Super By Pass Fillter
xii) Hose Clip Set
xiii) Piston set Complete
xiv Ring Set Complete
xv) Cyllinder Linner
xvi) Connecting Rod Bearing
xvii) Gasket Set Cyllinder Head
xvii) Callibration of Fuel Pump
xix )Head Repair Work
xx ) Callibration of injectors of Nozzels
xxi ) Lubrication Oil Pump
xxii ) O ' Ring Set Complete
xxiii) Set of Fuel Flexible Pipe
xxiv) Stem Seal
M& L for Servicing of DG Sets of capacity 250 KVA /320 KVA of make (Make : Greaves/ Kirloskar/ Cummins or any other make) by the authorised Engineer of respective manufacturer of DG Set continous operational condition including the following checkings all as specified and directed by Engr-in -charge (Egnine oil and coolent reaquired for this job is deemed to be included in the quoted rate.
(i) Removing the existing engine oil, clean the oil sump and refilling with required quantity of new engine oil 20W40 & coolant upto top.
(ii) Checking of fan motor hub
(iii) Checking exhaust and inlet manifold belt and cap screw
(iv)Cleaning of radiator inside and out side thoroughly with solution (caustic soda) to the entire satisfaction of Eng-in-charge by removing and re-fixing in original position after cleaning.
(v) Checking and adjusting injector and valves, tappet and replace the gasket including cost of gasket.
(vi) Cleaning fuel inlet connections and screw,
(vii) Checking of vibration damper and rectified.
(viii) Servicing of turbocharger by checking, leakage tightening of mounting screws & nuts and replace oil.
(ix) Checking water temperature safety control
(x) Checking and correcting up impeller of water pump for excess play.
(xi) Servicing of governer and Changing of governor oil.
(xii) Checking and adjusting all fan belt.
(xiii) Any other check as per manufacturer`s instructions
Note:- Necessary spare parts required if any will be measured and paid under relevant items
(a) S & F in repairs Kit, fuel filter and ring
(b) S & F in repairs Element for Lubrication oil filter.
(c)S & F in repairs Kit, Element of super bypass filter.
(d) S & F in repairs Seal, O Ring and Air cleaner.
(e ) S & F in repairs Kit Conversion
(f )S & F in repairs Gasket, Rocker lever cover
All as per item no.4 above but for DG Sets of Capacity 180 KVA DG set,
(a) S & F in repairs Kit, fuel filter and ring
(b) S & F in repairs Element for Lubrication oil filter.
(c)S & F in repairs Kit, Element of super bypass filter.
(d) S & F in repairs Seal, O Ring and Air cleaner.
(e ) S & F in repairs Kit Conversion
(f )S & F in repairs Gasket, Rocker lever cover
All as per item no.4 above but for DG Sets of Capacity 100 KVA DG set
(a) S & F in repairs Kit, fuel filter and ring
(b) S & F in repairs Element for Lubrication oil filter.
(c)S & F in repairs Kit, Element of super bypass filter.
(d) S & F in repairs Seal, O Ring and Air cleaner.
(e ) S & F in repairs Kit Conversion
(f )S & F in repairs Gasket, Rocker lever cover
All as per item no.4 above but Diesl Engine of 62.5/ 63/50 KVA DG set
(a) S & F in repairs Kit, fuel filter and ring
(b) S & F in repairs Element for Lubrication oil filter.
(c)S & F in repairs Kit, Element of super bypass filter.
(d) S & F in repairs Seal, O Ring and Air cleaner.
(e ) S & F in repairs Kit Conversion
(f )S & F in repairs Gasket, Rocker lever cover
All as per item no.4 above but DG Sets of Capacity 40/30 KVA DG set
(a) S & F in repairs Kit, fuel filter and ring
(b) S & F in repairs Element for Lubrication oil filter.
(c)S & F in repairs Kit, Element of super bypass filter.
(e ) S & F in repairs Kit Conversion
(f )S & F in repairs Gasket, Rocker lever cover
All as per item no.4 above but DG Sets of Capacity 25/20/15 KVA DG set
(a) S & F in repairs Kit, fuel filter and ring
(b) S & F in repairs Element for Lubrication oil filter.
(c)S & F in repairs Kit, Element of super bypass filter.
(d) S & F in repairs Seal, O Ring and Air cleaner.
(e ) S & F in repairs Kit Conversion
(f )S & F in repairs Gasket, Rocker lever cover
M&L for Rewinding of armature of Dynamo/alternators 12V/24V volts with `F' class copper wire to match existing gauge including dismantling of old coil , cleaning thoroughly winding with super enameled copper wire of existing size and gauge,varnishing, drying etc and fixed with dynamo/alternator properly tesing and commissioning all as specified all and directed by Engr-in-Charge.
S & F repair radiator hoses of size 40mm dia or as per existing dia and 60 cm length for any capacity of DG set including jublee clip, clamp nuts etc are properly fixed and connected.as directed to the satifaction of the Engr-in -Charge
S & F in replacement of flexible pressure pipe for lubricant size of 60 cm length for oil and fuel connection for complete suitable for 180/100/82.5 KVA/63 KVA Engineas directed to the satifaction of the Engr-in -Charge
Supply and filling Engine oil 20W/40f complete all as directed by Engineer-in-Charge.
S& Fill distilled water packed in sealed gallan of 5 Ltrs complete all as directed by Engineer-in-Charge.
Supply and filling water coolant(diluted)in radiator (make volve line or equivalent) including removal of old water/coolant, complete all as directed by Engineer-in-Charge.
Dismantling and removing of water pump assembly of any capacity any type of DG Set complete from the engine,repair/overhauling the same by replacing tornout components like bearing,impeller,bushes, oil seal,water seal,gaskets etc. reassembling,refixing and testing complete as directed to the satifaction of the Engr-in -Charge
Repair/overhauling of self starter 12V/24V including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch,carbon brushes,brush spring etc.as directed to the satifaction of the Engr-in -Charge for the 250 KVA DG Set
Repair/overhauling of self starter 12V/24V including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch,carbon brushes,brush spring etc.as directed to the satifaction of the Engr-in -Charge for the 180/125 KVA DG Set complete all as directed by Engineer-in-Charge.
Repair/overhauling of self starter 12V/24V including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch,carbon brushes,brush spring etc.as directed to the satifaction of the Engr-in -Charge for the 100 KVA to 63 KVA DG Set complete all as directed by Engineer-in-Charge.
Repair/overhauling of self starter 12V/24V including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch,carbon brushes,brush spring etc.as directed to the satifaction of the Engr-in -Charge for the 20/25/40 KVA DG Set complete all as directed by Engineer-in-Charge.
M & L for replacement of totally damaged self starter 12V/24V complete assembly suitable for any capacity of DG Set complete all as directed by Engineer-in-Charge.
Repair/overhauling of dynamo including replacement carbon, brushes holder, spring, commutator /slipring assembly bearing, regulator etc. of any make, type and capacity.complete all as directed by Engineer-in-Charge.
Supply in replacement of electrically operated fuel shut down valve assembly complete testing and commissioning as specified and directed by Engr.in-charge including dismantling and removal of old U/S valves of any capacity DG set.complete all as directed by Engineer-in-Charge.
Servicing/repairs of AMF panel complete including cleaning resetting/adjustment of relays,calibration of time delay relays, checking and replcement of diods, if required ,resistors contactor etc. complete for any make/type and capacity of DG sets. complete all as directed by Engineer-in-Charge.
Disconnecting and dismantling the alternator unit of 250 KVA DG Set from the base plate of the DG set and transporting to workshop for repair, dismantling the unit, further separating the armature from the startor carefully, cutting and taking out the burnt windings of the alternator carefully, cleaning the slots and , duly applying the insulation and assembling the stampings inserting in position in the startor including applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of same gauge and same number of turns as that of existing one including replacement of carbon brushes tapping the windings and bringing out the coil conections for production of 3 phase 415 volt 50 HZ AC supply and preheating the windings and applying insulating varnish and drying the windings in oven and assembling the unit and transporting back to installation and fixing on base plate and coupling with the DG set and testing complete all as specified and directed.
Disconnecting and dismantling the alternator unit of 180/125/100 KVA DG Set from the base plate of the DG set and transporting to workshop for repair, dismantling the unit, further separating the armature from the startor carefully, cutting and taking out the burnt windings of the alternator carefully, cleaning the slots and , duly applying the insulation and assembling the stampings inserting in position in the startor including applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of same gauge and same number of turns as that of existing one including replacement of carbon brushes tapping the windings and bringing out the coil conections for production of 3 phase 415 volt 50 HZ AC supply and preheating the windings and applying insulating varnish and drying the windings in oven and assembling the unit and transporting back to installation and fixing on base plate and coupling with the DG set and testing complete all as specified and directed.
Disconnecting and dismantling the alternator unit of 63 KVA DG Set from the base plate of the DG set and transporting to workshop for repair, dismantling the unit, further separating the armature from the startor carefully, cutting and taking out the burnt windings of the alternator carefully, cleaning the slots and , duly applying the insulation and assembling the stampings inserting in position in the startor including applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of same gauge and same number of turns as that of existing one including replacement of carbon brushes tapping the windings and bringing out the coil conections for production of 3 phase 415 volt 50 HZ AC supply and preheating the windings and applying insulating varnish and drying the windings in oven and assembling the unit and transporting back to installation and fixing on base plate and coupling with the DG set and testing complete all as specified and directed.
Disconnecting and dismantling the alternator unit of 50/25 KVA DG Set from the base plate of the DG set and transporting to workshop for repair, dismantling the unit, further separating the armature from the startor carefully, cutting and taking out the burnt windings of the alternator carefully, cleaning the slots and , duly applying the insulation and assembling the stampings inserting in position in the startor including applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of same gauge and same number of turns as that of existing one including replacement of carbon brushes tapping the windings and bringing out the coil conections for production of 3 phase 415 volt 50 HZ AC supply and preheating the windings and applying insulating varnish and drying the windings in oven and assembling the unit and transporting back to installation and fixing on base plate and coupling with the DG set and testing complete all as specified and directed.
Disconnecting and dismantling the alternator unit of 20/10 KVA DG Set from the base plate of the DG set and transporting to workshop for repair, dismantling the unit, further separating the armature from the startor carefully, cutting and taking out the burnt windings of the alternator carefully, cleaning the slots and , duly applying the insulation and assembling the stampings inserting in position in the startor including applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of same gauge and same number of turns as that of existing one including replacement of carbon brushes tapping the windings and bringing out the coil conections for production of 3 phase 415 volt 50 HZ AC supply and preheating the windings and applying insulating varnish and drying the windings in oven and assembling the unit and transporting back to installation and fixing on base plate and coupling with the DG set and testing complete all as specified and directed.
Supply in replacement of diode assembly complete suitable to match the existing one of 250 KVA alternator excitor unit.
Supply in replacement of diode assembly complete suitable to match the existing one of 180/125/100KVA alternator excitor unit. complete all as directed by Engineer-in-Charge.
Supply in replacement of diode assembly complete suitable to match the existing one of 63/50/40/30 KVA alternator excitor unit. complete all as directed by Engineer-in-Charge.
Supply in replacement of diode assembly complete suitable to match the existing one of 12.5/20/25 KVA alternator excitor unit. complete all as directed by Engineer-in-Charge.
Supply in replacement of PVC insulated battery lead with 16 Sq.mm copper conductor cable of length 2 mtr with copper/brass clamps and lugs for fixing on battery terminals and self starter complete as specified and as directed.
Supply in replacement of rectifiers for alternators suitable for Gensets upto 40/63/82.5/100/110KVA capacity complete as specified and as directed.
Supply and fixing carbon brushes suitable for alternators upto 250 KVA gensets. complete as specified and as directed.
Supply in replacement of RPM meter complete with cable and accessories at the last range 0 to 2500 complete as specified and as directed.
Supply in replacement of water temperature gauge complete with cable and accessories at the last range 0 to 150 degree centigrate complete as specified and as directed.
Supply in replacement of oil temp gauge as per existing site requirement complete as specified and as directed.
Supply in replacement of oil pressue gauge as per existing site requirement complete as specified and as directed.
Dismantling the defective Fuel Injector Assembly of any capacity from the existing foundation and engine including taking down all electrical connections transporting to approved authorised workshop, after setting up opening the complete, connector plate, gasket & complete overhauling re- assembling the Fuel Injector after transporting back to site re-installing carrying out alignment of complete DG set reconnecting up all electrical connections testing and commissioning complete the following capacity of DG set (Note:- (a) Rate quoted shall be deemed to be inclusive making good the distrubed surfaces (b) The DG set shall be tested for the satisfaction of Engr -in -charge to achive designed parameters.
(a)180 KVA capacity DG Set
(b) 100/62.5/50 KVA DG
(c) 40/30/25/20 KVA DG
S & F in repair battery terminal brass superior quality suitable for 180 AH 12 Volts Battery complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement of ignition switch and key of 110/100/ 82.5 KVA DG Set complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement of ignition switch and key of 63/40 KVA DG Set complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement of AVR unit of 250 KVA to 100 KVA for matching the existing AVR unit, complete all as specified and directed by Eng-in charge.
Supply and fixing in replacement of AVR unit of 63 KVA to 40 KVA for matching the existing AVR unit, complete all as specified and directed by Eng-in charge.
Supply and fixing in replacement of AVR unit of 25/20/10 KVA for matching the existing AVR unit, complete all as specified and directed by Eng-in charge.
S&F in replacement of contactor suitable for AMF panel contactor MNX 32 3pole 240V as per existing contactor of site complete all as directed by Engineer-in-Charge.
S&F in replacement of contactor suitable for AMF panel contactor MNX 25 3pole 240V as per existing contactor of site complete all as directed by Engineer-in-Charge.
S&F in replacement of contactor suitable for AMF panel contactor MNX 16 3pole 240V as per existing contactor of site complete all as directed by Engineer-in-Charge.
S&F free lead acid battery 12 volts 180 AH complete all as specified and as directed by Engr-In-Charge.
M&L for servicing/ cleaning of MS diesel tank of DG set 180/160/100 KVA by draining out the diesel from tank, cleaning the tank with soap water/ suitable solution and painting the external surface with one coat of synthetic enamel paint of existing colour including repalcement of drain valve, outlet pipe complete all as specified and as directed.
M&L for servicing/ cleaning of MS diesel tank of DG set 62.5/40/50/25 KVA by draining out the diesel from tank, cleaning the tank with soap water/ suitable solution and painting the external surface with one coat of synthetic enamel paint of existing colour including repalcement of drain valve, outlet pipe complete all as specified and as directed.
S&F in replacement of MCCB, three pole, 160 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed
S&F in replacement of MCCB, three pole, 125 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed
S&F in replacement of MCCB, three pole, 100 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed(Make: Legrand/ABB/Siemens).
S&F in replacement, fan belt suitable for 12.5 KVA DG set complete all as specified and as directed.
S&F in replacement, fan belt suitable for 20/25//30 KVA DG set complete all as specified and as directed.
S&F in replacement, fan belt suitable for 40/50 KVA DG set complete all as specified and as directed.
S&F in replacement, fan belt suitable for 62.5/63 KVA DG set complete all as specified and as directed.
S&F in replacement, fan belt suitable for 100 KVA DG set complete all as specified and as directed.
S&F in replacement, fan belt suitable for 180 KVA DG set complete all as specified and as directed.
S&F in replacement, fan belt suitable for 250 KVA DG set complete all as specified and as directed.
Dismentling/ taking down complete radiator assembly of DG set 180 KVA and transporation to market for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete
Dismentling/ taking down complete radiator assembly of DG set 100 KVA and transporation to market for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete
Dismentling/ taking down complete radiator assembly of DG set 62.5 KVA and transporation to market for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete
Dismentling/ taking down complete radiator assembly of DG set 20/25/40 KVA and transporation to market for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete
Supply , laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavu duty aluminium conductor LT 1100 V grade cross sectional area 50 sq 3.5 core, complete all as specified and directed by Engineer-in-Charge
Supply , laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavu duty aluminium conductor LT 1100 V grade cross sectional area 70 sq 3.5 core, complete all as specified and directed by Engineer-in-Charge
Supply , laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavu duty aluminium conductor LT 1100 V grade cross sectional area 35 sq 3.5 core, complete all as specified and directed by Engineer-in-Charge
Supply , laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavu duty aluminium conductor LT 1100 V grade cross sectional area 25 sq 4 core, complete all as specified and directed by Engineer-in-Charge
S&F in replacement of Change over switch off load type with enclosure, conforming IS 13947 part I & III 415V, 4 pole of rating 100 amps, including taking out unservicable one complete all as specified and directed by Engineer-in -Charge.
S&F in replacement of Change over switch off load type with enclosure, conforming IS 13947 part I & III 415V, 4 pole of rating 200 amps, including taking out unservicable one complete all as specified and directed by Engineer-in -Charge.
S&F in change over switch on load type with enclosure, conforming IS 13947 part I & III 415V, 4 pole of rating 100 amps, including taking out unservicable one complete all as specified and directed by Engineer-in -Charge.
S&F commissioning and testing of CPRI approved outdoor cubical type LT panel IP-54 Protection for outdoor shell and IP- 42 for inner shall,suitable for 415V, 3 phase, 4 wire 50Hz, AC supply system fabricated fromstainless steel totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell and 2mm thick for inner shell having MS section not less then 50x50x6 mm thick having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with glands including control wiring with minimum 1.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, painting with two coat of smoke grey synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed by Engrineer-in-Charge. Note:- LT panel shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM1:6 and two coates of cement base paint and the rates shall be inclusive in the quoted rate. (Minimum size: 1.5*2.5*4.5 in Feet )
Incoming:
(a) MCCB 315 Amp 4 pole 38 KA Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 01 Nos
(b) Alum bus bar 400 Amp TPN - 01 Set
(e) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set
Outgoing
(a) MCCB 3 Pole, 100 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu- 02 Nos
(b) MCCB 3 Pole, 63 Amp, 20 KA, Adjustable Thermal* & Fixed Magnetic setting , Ics = 100% of Icu- 02 Nos
(c) On Load change over switch front operated suitable for 4 pole 415V of capacity 315 Amp
Supply in replacement of 24 Volt Relay ,taking down and reconnecting up all electrical connections testing and commissioning complete as directed to the satifaction of the Engr-in -Charge
Supply in replacement of 12 Volt Relay ,taking down and reconnecting up all electrical connections testing and commissioning complete as directed to the satifaction of the Engr-in -Charge
Supply and fixing in replacement of Didital volt meter as per existing size complete all as specified and directed.
Supply and fixing in replacement of Digital Amp meter as per existing size complete all as specified and directed.
Supply and fixing in replacement of Digital Frequency meter as per existing size complete all as specified and directed.
Supply and fixing in replacement of indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete all as specified and directed.
M/S Darshan Kumar
TARA ENTERPRISES
M/S KALSI ENGINEERS AND CONTRACTORS
M/S PRAJAPATI ENGINEERS
M/S SOHUM ENGINEERS
M/S J S ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .